HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
Business & Professional Regulation
r� r
BCIS Home Log In User Registration Hot Topics Submit Surcharge stats&Fads Publications FBC Staff SCIS Site Map Links Search
dba �.���..��'��.
r Product Approval
q USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL5444-R13 RECEIVED
Application Type Revision
Code Version 2017 p
Application Status Approved MAY 0 4 '01$
Comments ST. Lucie County, Permittin
Archived
Product Manufacturer CertainTeed Corporation-Roofing
Address/Phone/Email 20 Moores Road
Malvern,PA 19355
(610)893-5400
mark.d.harner@saint-gobain.com
Authorized Signature Mark Harper
mark.d.harner@saint-gobain.com
Technical Representative Mark D. Harrier
Address/Phone/Email 18 Moores Road
Malvern,PA 19355
(610)651-5847
Mark.D.Harner@saint-gobain.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
` Quality Assurance Contract Expiration Date 03/09/2020
Validated By John W. Knezevich,PE
V Validation Checklist-Hardcopy Received
Certificate of Independence FL5444 R13 COI 2018 01 COI NIEMINEN Ddf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By
USections from the Code
https:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtahl g07CSsoycOr128... 5/4/2018
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 01/24/2018
Date Validated 01/29/2018
Date Pending FBC Approval 01/30/2018
Date Approved 04/10/2018
Surnmary of Products
FL# Model,Number or Name Description
5444.1 CertainTeed Asphalt Roof Shingles 3-tab,4-tab,strip(no-cut-outs),laminated and architectural
asphalt roof shingles
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL5444 R13 II 2018 01 FINAL ER CERTAINTEED ASPHALT
Approved for use outside HVHZ: Yes SHINGLES FL5444-R13.Ddf
Impact Resistant: N/A Verified By: Robert Nieminen,PE PE-59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other: Refer to ER Section 5 for Limits of Use Evaluation Reports
FL5444 R13 AE 2018 01 FINAL ER CERTAINTEED ASPHALT
SHINGLES FL5444-R13.Ddf
Created by Independent Third Party: Yes
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Coovrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
® 0—i " �k�
Credit Card
Safe
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQ WtDotah 1 g07CSsoycOrl28... 5/4/2018
NEMO I etc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION REPORT
CertainTeed Corporation Evaluation Report 3532.09.05-1114
20 Moores Road FL5444-1113
Malvern, PA 19355 Date of Issuance:09/22/2005
(610)651-5847 Revision 14:01/24/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein.
DESCRIPTION: CertainTeed Asphalt Roof Shingles.
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein
and FBC 1507.2.7.1/R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMOJetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 13.
Prepared by:
Robert J.M.Nieminen,P.E.
Florida Registration No.59166,Florida DG4 ANE1983
Oc.•�'.^e cTf �: The facsimile seal appearing was authorized by Robert
% F •. _ ,.
Nieminen,P.E.on 01/24/2018. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMOIetc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMOIetc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEMO I etc.
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: CertainTeed Asphalt Roof Shingles, as produced by CertainTeed Corporation, have
demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and 6th Edition
(2017) Florida Building Code, Residential Volume through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Enti Examination Reference Date
UL(TST 1740) ASTM D3161 94NK9632 05/15/1998
UL(TST 1740) ASTM D3161 99NK26506 11/23/1999
UL(TST 1740) ASTM D3161 03CA12702 05/27/2003
UL(TST 1740) ASTM D3161 03CA12702 06/16/2003
UL(TST 1740) ASTM D3161 03NK29847 10/03/2003
UL(TST 1740) ASTM D3161 04CA11329 05/24/2004
UL(TST 1740) ASTM D3161 04CA32986 12/03/2004
UL(TST 1740) ASTM D3161 05NK07049 04/15/2005
UL(TST 1740) ASTM D3161 05NK16778 05/12/2005
UL(TST 1740) ASTM D3161 05CA16778 05/12/2005
UL(TST 1740) ASTM D3161 05NK14836 05/22/2005
UL(TST 1740) ASTM D3161 05NK22800 06/22/2005
UL(TST 1740) ASTM D3462 R684 09/21/2005
UL(TST 1740) ASTM D7158 05NK08037 06/28/2006
UL(TST 1740) ASTM D3161&D3462 09CA28873 07/23/2009
UL(TST 1740) ASTM D3462 10CA41303 10/07/2010
UL(TST 1740) ASTM D3161 10CA41303 10/08/2010
UL(TST 1740) ASTM D7158 IOCA41303 10/27/2010
UL(TST 1740) ASTM D3161&D3462 10CA44960 11/11/2010
UL LLC(TST 9628) ASTM D3161,D3462&D7158 13CA32897 11/21/2013
UL LLC(TST 9628) ASTM D3161,D3462 TFWZ.R684 04/22/2014
UL LLC(TST 9628) ASTM D7158 TGAH.R684 04/22/2014
ULLLC(TST 9628) ASTM D3161&D3462 4786334434 09/16/2014
ULLLC(TST 9628) ASTM D3161&D3462 4786570826 02/12/2015
ULLLC(TST 9628) ASTM D3161,D3462&D7158 4786570717 12/16/2015
ULLLC(TST 9628) ASTM D3161&D3462 4787195678 02/09/2016
ULLLC(TST 9628) ASTM D3161,D3462&D7158 4787380356 10/26/2016
ULLLC(TST 9628) ASTM D3462 4787380357 10/13/2016
ULLLC(TST 9628) ASTM D7158 4787380357 11/08/2016
ULLLC(TST 9628) ASTM D3161 4787380357 11/09/2016
UL LLC(TST 9628) ASTM D3161,D3462&D7158 4787586427 01/25/2017
ULLLC(TST 9628) ASTM D3161&D3462 4788042412 11/15/2017
UL LLC(QUA 9625) Quality Control Service Confirmation Exp.03/09/2020
NEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1113
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 2 of 13
ONEMOletc.
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 CT20TM,XTT"25,XTr""30 and XTTm 30 IR are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Arcadia TM, Belmont®, Belmont® IR, Carriage House Shangle®, Grand Manor Shangle®, Landmark"",
Landmark TM IR, Landmark TM Pro, Landmark TM Premium, LandmarkT"" TL, LandmarkT"" Solaris and
Landmarklm Solaris IR are fiberglass reinforced,laminated asphalt roof shingles.
4.1.3 NorthGate T1 is a fiberglass reinforced, laminated,SBS modified bitumen roof shingle.
4.1.4 Presidential Shaker"", Presidential Shaker" IR, Presidential Shake TL` and Presidential SolariST"" are
fiberglass reinforced,architectural asphalt roof shingles.
4.1.5 HatteraST"", Highland SlateT"and Highland Slate TM IR are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.6 Patriot' is a fiberglass reinforced asphalt roof strip-shingle (with no cut-outs) providing a laminated
appearance through an intermittent shadow line with contrasting blend drops for color definition.
4.2 Hip&Ridge Shingles:
4.2.1 Presidential Accessory, Accessory for Hatteras, Shangle RidgeT", Shadow Ridge TM, Cedar CrestTM, Cedar
CrestT" IR, NorthGate Ridge and NorthGate Accessory are fiberglass reinforced accessory shingles for hip
and ridge installation.
4.3 Accessory Starter Strips:
4.3.1 SwiftStart® Starter Shingle is a starter strip for asphalt roof shingles. Its overall size of 15-1/4" x 38-3/4"
yields two(2)7-5/8"x 38-3/4"starter pieces per shingle.
4.4 Any of the above listed shingles may be produced in AR(algae resistant)versions.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMOJetc. nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use within FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.4 Wind Classification:
5.4.1 All shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM
D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for us in all wind zones
UP to Vasd = 150 mph (V,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind
rating.
5.4.2 Presidential Accessory, Accessory for Hatteras, Shangle Ridge, Shadow Ridge, Cedar Crest, NorthGate
Ridge and NorthGate Accessory hip & ridge shingles have been evaluated in accordance with ASTM
D3161,Class F. All except NorthGate Ridge and NorthGate Accessory require use of BASF Sonolastic NP 1
adhesive or Henkel PL® Polyurethane Roof & Flashing Sealant, applied as specified in manufacturer's
application instructions, for use in wind zones up to Vasd= 150 mph (Vu,,= 194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 SwiftStart®Starter Shingle has been evaluated in accordance with ASTM D3161,Class F. Refer to Section 6
for installation requirements to meet this wind rating.
5.4.4 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations.
Contact the shingle manufacturer for data specific to each shingle.
NEMO ETC,LLC Evaluation Report 3532.09.05-1114
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1113
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 3 of 13
ONEMOletc.
5.4.4.1 Analysis in accordance with ASTM D7158 indicates the measured uplift resistance(RT)for the CertainTeed
asphalt Roof shingles listed in Section 4.1 through 4.6(except Presidential Solaris'") exceeds the calculated
uplift force (FT) at a maximum design wind speed of Vaed = 150 mph (V„It = 194 mph) for residential
buildings located in Exposure D conditions with no topographical variations (flat terrain) having a mean
roof height less than or equal to 60 feet. The shingles are permissible under Code for installation in these
conditions using the installation procedures detailed in this Evaluation Report and CertainTeed minimum
requirements, subject to minimum codified fastening requirements established within any local
jurisdiction,which shall take precedence.
5.5 All products in the roof assembly shall have quality assurance audits in accordance with FAC Rule 61G20-3.
6. INSTALLATION:
6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.1 Underlayment shall be acceptable to CertainTeed Corporation and shall hold current Florida Statewide
Product Approval, or be Locally Approved per Rule 611320-3, per FBC Sections 1507.2.3, 1507.2.4 or
R905.2.3.
6.2 Installation of asphalt shingles shall comply with the CertainTeed Corporation current published
instructions, using minimum four(4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6
and the minimum requirements herein.
6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal,use the"Steep Slope"directions.
6.3 CertainTeed asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the
limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions.
6.4 SWIFTSTART"'STARTER SHINGLE:
Fastening: Use four nails, located as shown below
38-3/4" (984 mm)
t
1' (25 mm)from edge 1'(25 mm)from edge —►I 7-5/8"
Max 3"
• • • • (194 mm)
(76 mm)I L
1 The inner two fasteners must be placed such that they fall at least 3"(76 mm)from
the end joints of the shingle in the succeeding course.
NEMO ETC,LLC Evaluation Report 3532.09.05-R34
Certificate ojAuthorizotion#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1113
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 4 of 13
NNEMO I etc.
LOW AND STANDARD SLOPE STEEP SLOPE
ENGLISH 12" 12" 12" Use four nails and six spots of asphalt roofing cement*for every full
x+(305 mm)----(305 mm) (305 mm) shingle(Figure 11-4).Asphalt roofing cement meeting ASTM D4586
(-1"(25 mm) _Sealant_ 1"(25m Type 11 is suggested.
5 5/e"(145 mm) 1
5112"fotAbtwnodPlant
METRK
13 —
131/13" 131/13" 1/13"
Roofing Cement
1"(25 mm) Sealant 1"(25 mm) Apply 1"(25 mm)spots of asphalt roofing cement
under each tab corner.
6 1/8- Figure 114-Use four nails and six spots ofrupbalt csmart on steep&biW
*CAUTION:Excessive use of roofing cement can cause shingles
to blister,
Figure 113:Use four nails for every jW sbingle.
6.5.1 Hip&Ridge for CT20T".XT•"25,XTT"30,XT'"30 IR: Cut Shingles
(251mm)II� 2"(50 mm) rRenovey
l ( I I 5„ 12°(305 mm)l—� F�d�
�(— — — i� — — l�_ _ _ tl
(125 011)
_ 12" N,`,5m
Cap Cap Cap 305 mm) •�► �istnas
Shingle Shingle Shingle 6518 shov+n\ao`l
Figure I1-24:Cut tabs,then trim back to make cap sbingles
(Engtisb dimensions sbown).
Figure 11-25:Installation of caps along the bips and ridges.
6.5.1.1 For ASTM D3161, Class F performance use BASF "Sonolastic® NP111" adhesive or Henkel "PL®
Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements.
6.6 ARCADIA TI:
LOW AND STANDARD SLOPE STEEP SLOPE
L se SIX nails for even full shingle located as shown below. Use SIX nails and FOUR spots of asphalt roofing cement for every full
shingle as shown below.Apply asphalt roofing cement 1"(25 mm)
from edge of shingle.Asphalt roofing cement meeting ASTM D 4586
Type Il is suggested.
f 1'(25 mn) 1"(25 mm) y
Nail Line
Nail
Nail Line f 1'(25 nm) 1'(25 mm)— �--
Figure 2:Use skr nails for etwn-full sbingle.
Figure 3:V;e sir nails and four spots of asphalt
roofrrrg cement on steep slopes.
NEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/Z018
Page 5 of 13
ONEMOletc.
6.6.1 Hip&Ridge for Arcadia'": Cedar Crest'",Cedar Crest'"IR
Use two (2), minimum 1%-inch long fasteners per shingle. For the starter shingle, place fastener 1-inch
from each side edge and about 2-inch up from the starter shingle's exposed butt edge,ensuring minimum
%-inch embedment into the deck,or full penetration through the deck. For each full Cedar Crest shingle,
place fasteners 8-5/8-inch up from its exposed butt edge and 1-inch from each side edge.
For ASTM D3161,Class F performance use BASF"Sonolastic®NP11"adhesive or Henkel "PL®
Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements,to hand-seal
Cedar Crest shingles. Apply NP 1 or PL adhesive from the middle of the shingle's raised overlay on the
top piece and extending approximately 4-inch along the sides of the headlap along a line%to 1-inch from
each side of the shingle's headlap. Immediately align and apply the overlying shingle,gently pressing tab
sides into the adhesive,and install nails. To secure the other side,apply a 1-inch diameter spot of NP 1 or
PL adhesive between the shingle layers.
Hand-sealing adhesive
8. 12 1/4" 4„
I�ExP"'" •����`'mR` 3/4" If-
e�
1"
Dab of asphalt
cement between 1"
shingle layers
6.7 • OR BELMONT
Low and Standard Slope Steep Slope(greater than 21:12):
(2:12 to 21:12): Use SEVEN nails and EIGHT spots of
Use FIVE nails for every full Belmont shingle, asphalt roofing cement"for every full
located as shown below. Belmont shingle.Apply asphalt roofing
cement 1"(25mm)from edge of shingle-
11 or See below.Asphalt roofing cement meeting
ASTM D4586 Type II is suggested.
51°'(16 mm)Li °Y8 t,n(38mn)
WD mm)
«lea t U
o Addtionl nib d**xW. —' V(25 mm) t'(25 mm)—H +—
SI°'(16mm)
+ (220 mm)
t'(25 mm RoaliW Cement
NEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization#32455 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1113
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 6 of 13
ONEMOjetc.
6.7.1 Hip&Ridge for Belmont®or Belmont®IR:
6.7.1.1 Option 1: For Belmont®, refer to instructions herein for Cedar Crest•"or Cedar Crest'"IR hip and ridge
shingles. For Belmont® IR,refer to instructions herein for Cedar CreStTM IR hip and ridge shingles.
6.7.1.2 Option 2: For Belmont®: Shangle®Ridge
Remove tape
12" t$ Exposure from the right side
and fasten
r SECOND
Fasten the .�
Remove left side 85/8 / RIGHT
This Tape FIRST
LEFT
Figure 17-19:Installation of Shangle®Ridge shingles
Figure 17-18.'Shangle"Ridge. on hips and ridges.
6.7.1.3 For ASTM D3161,Class F performance use BASF"Sonolastico NP111"adhesive or Henkel "PL®
Polyurethane Roof&Flashing Sealant", in accordance with CertainTeed requirements.
6.8 CARRIAGE HOUSE SHANGLE"AND GRAND MANOR o
LOW AND STEEP SLOPE
STANDARD SLOPE ('se seven nails and three spots of asphalt roofing cement for every
Use five nails for revery hull Shangle, fidl Grand Manor Shangle.lyse five nails and three spots of asphalt
roofing cement for every full Carriage(louse Shangle and Centennial
Slate.Apply asphalt roofing cement 1"(25 mm)from edge of shingle
(Figure 17-5).Asphalt roofing cement nimling ASTM D4580 T1pe II
is suggested.
(25 mm) (25 mm)
112"
5/6' 8 518" (38 mm)
(16 mm) (220 mm) 1" or lass 1..
I«(25 mm) (25 mm)
Figure 17--fuse fete nails for earl'full Grand Alanor,Shangle. 5� 58 '
Carriage House Shangle.or!.enlennial Slate. (16 mall i (220 mm)
(25 nm) Rooting Cement
Figure 17-5:When installing Grand.11anor Sbangles on sleep slopes.
trse sererr nails and three slaws)j aspNill roofing cement.
6.8.1 Hip&Ridge for Carriage House Shangle®and Grand Manor Shangle:Refer to instructions herein for
Shangle®Ridge hip and ridge shingles
NEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization#32455 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 7 of 13
ONEMO I etc.
6.9 LANDMARK", LANDMARK" IR, LANDMARKT" PRO, LANDMARK'" PREMIUM, LANDMARK'" TL, LANDMARK'" SOLARIS,
LANDMARK'"SOLARIS IR,NORTHGATE:
LOW AND STANDARD SLOPE LANDMARK Tl
131/7' 13" 131/7'
METRIC DIMENSIONS 1—(343 mm)—f-(330 mm)—j—(343 mm)-►i
12" 143/4" 12" f-1"(25 mm) 1"(25 mm)-
�--(305 mm)—I—(375 mm)—I—(305 mm) ►�
--'-..:..t.hv-.v_._.[.• i:
1"(25mm) Release Tape 1"(25mm)�I f
11/2'
Nailable� .
Area Figure 13-4:tse four nails for eirrr frdl shingle.
NorthGate:
WIDE
WAING 12• 143r4• IT
AREA 305 mm) w�(375 mm) — + (305 mm) ►I
Nein#Umfa
T(25 mm) Uw nal lm r(25 mm)- •-
owr nai lnr
Naft arm for low and sbndard dqw(from 2:12 b 21:12)
Nal ortwrrn oppar 8 brwr F+rs as shown abM.
STEEP SLOPE
['se six nails and four spots of asphalt roofing cement for every full LANDMARK TL
laminated shingle.see below.Asphalt roofing cement should meet
ASTM D4586 1`yT1e II.Apply 1"spots of asphalt roofing cement uncle
each corner and at about 12"to 13"in from each edge. 131/2" 13" 131/2"—�
(343 mm) (330 mm) (343 mm)
METRIC DIMENSIONS 1"(25 mm) 1"(25 mm)
I
+—12' �-143/4143/4--12"
(305 mm) (375 mm) (305w r
(25 mm) (25 mm)
::- .: ::. , . r,-� •� Rooting Cement
�+
1'(25 mm) Release Tape 1"(25 mm)—
Nail Area
For Steep T Figure 133.'Use sur nails and four spots of
1" ►�I� �-1" aspbalt roofing cement on steep slopes.
(25 mm) ---- (25 mm;
Roofing Cement
NEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certificote of Authorirotion#31455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 8 of 13
NNEW10jetc.
NorthGate:
STEEP 12" 14-3/4" 12•
SLOPE 1—(305 mm)- --(375 mnrr� —(305 mm)- i
NAILING Nailin imits
��1 1"(25 mm t>etwee l.�?Wer 1"(25 mm-
( ) nal Ines.71.1
( )
t
��—
Roo mg ement
Nailing areas for steep slopes(greater than 21:12)
and"Storrt}Nailing"
Na I be'Aeen Ic,,wr 2 nail lines as shown above.
6.9.1 Hip&Ridge for Landmark*"", Landmark-IR, Landmark`""Pro,Landmark- Premium, Landmark-TL,
Landmark-Solaris, Landmark-Solaris IR,NorthGate:
6.9.1.1 Option 1: Shadow Ridge- or NothGate Accessory
12" �, 97/8'
(305mm)— (250mm)
,.--415/16 415/16'
6 6(150mm) (150mm) (125mm) (125mm)
Notch for Notch for
Centering Centering
12" f 131/4"
(305mm) Notches for Alignment to (337 m) Notches for Alignment to
the Top Edge of the Previous (180 m) the Top Edge ot the Previous (19755
/8"
Cap for 5"(1 25mm)Exposure Capfor55/8"(141mm)Exposure
English Dimension Metric Dimension
Shadow Ridge- Shadow Ridge'"
9 27/32'
(250 mm)
415/15(125 mm)
13 1/8"
—(333 mm)�
Centering Nath -"5/8'�I"5/8,i
(168 mm) 168 mnn
13 1/4'
(337 mm) ` Migo these T ? Centering
notches to top 13 1/4" Notch
edgeOf 7 5 8 (337 mm)
(194 r^m) Align these 1-41
ptewoui COur30 I notches to top (194 mm)
jl edge of
previous course.
NorthGate Ridge NorthGate Accessory
NEW ETC,LLC Evaluation Report 3532.09.05-R14
Certificate ofAuthorizotion#32455 6'EDITION(2017)FBC NON-HVH7 EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 9 of 13
ONEMOletc.
12• J
(305m0` I
Laying Notch
I
5•15urme)
I � I
I
Figure 13-20•Use laying nokbm to center shingles on hips and
ridges,and to locate the correct exposure.
6.9.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic® NPi'"" adhesive or Henkel "PL®
Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements.
6.9.1.3 Option 2: Refer to instructions herein for Cedar Crest'",Cedar CrestTM IR hip and ridge shingles.
6.10 PRESIDENTIAL SHAKE—,PRESIDENTIAL SHAKE'"IR,PRESIDENTIAL SHAKE TU",PRESIDENTIAL SOLARIST":
LOW AND STANDARD SLOPE: STEEP SLOPE:
For low and standard slopes,use five nails for each full Presidential For steep slopes,use tine nails for each full Presidential shingle and
shingle as shown below, apply 1'diameter spots of asphalt roofing cement under each shingle tab.
After applying 5 nails in between the walling guide lines,apply 4 mails I'
Nailing ;. 40° above tab cutouts rnaldng certain tabs of overlying shingle cover nails,
Guide Lines (1016 mm)
5 114'
(133 mm)
• • 14 1/4"
1 1/2' 38 mm) (36 2 mm) • •—
—r-- •- - - - - - - + 1„
NOTE:Apply nails on painted guideline.
Figure 16-6.•FasteningFresidenAW and Presidential TZ Shake 1'diameter asphalt roofing cement
sbingles on low and standard slope..
Figure 16-7.•Fastening Presidential and Presidential M Sbake
sbingles on steep slopes.
6.10.1 Hip&Ridge for Presidential Shake'",Presidential Shake'""IR,Presidential Shake TL'" Presidential
Solaris—:
6.10.1.1 Option 1:Presidential Accessory
PRESIDENTIAL ACCESSORY
Presidential accessory shingles can be used for covering hips and
ridges.Apply shingles up to the ridge (expose no more than 7"from
the bottom edge of the"tooth."Fasten each accessory with two fas-
teners.The fasteners must be 13/4'long or longer, so they penetrate
either 3/4' into the deck or completely through the deck. Presidential
accessory comes in two different sizes:Accessory produced in
Birmingham,AL Is 12"x 12";Portland,OR produces 97/8"x 131/4'
accessory.
6.10.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic® NP1' " adhesive or Henkel "PL®
Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements.
NEMO ETC,LLC Evaluation Report 3532.09.05-R34
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1113
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 10 of 13
ONEMO etc.
6.10.1.3 Option 2: Refer to instructions herein for Cedar Crest`",Cedar Crest'"IR hip and ridge shingles.
LOW,STANDARD AND STEEP SLOPE: --9 _y _g _� ►{
� (230 mm) (230 mm) (230 mm) (230 mm) I
I (230 mm) (230,.-),r(24 mm) (230 mm) I I
x(25 mm)L_ _25 mm) -
9 318'
I-x-(25 mm)__ __25 mm)-1 (240 mm)
93181, --Roolinp Cemenl
(240 mm)
Figrnr 15.is Fastening llaaems.s'hMies on.Vmp.Vopes
ILI I
For steep slopes.a e Ore nails and eight spots of asphalt roofing
Figure 15-3:Fuslening llalreras.Shingles on cement for each full Itatirms shingle as shown abosr.Apply I-
loirand Slandard.Voprs (25mm)diameter spots of roofing cement(A%TM D 4586 Ape II
For ba and standard slopes,use fne nails for each full suggested)ander cacti tab corner.Press shingle into place;do not
Hatteras shingle as shown abot-e. espose cement.
CAUTION:Too much roofing cen>rm can cause shingles to blister.
6.11.1 Hip&Ridge for Hatteras'":
6.11.1.1 Option 1: Accessory for Hatteras
Fasten both sides
I
t
I `
I
I
1 2 3
Figure 15-14:18 three piece units separate to make
54 HatterasAo every shingles.
6.11.1.2 Option 2: Cut Hatteras Shingles
9,
(230 mm) I
I I
Fa ea
8' 18"(462
- -- --1---I--- 18" (203 mm)
-- I
460 mm)Cap Cap Cap CapShinglShingle Shingle `C`24Omml
Figure 15-20.•Cut Hatteras shingles to make cover cap. Figure 15-21:Install tion of caps along hips and ridges.
6.11.1.3 For ASTM D3161,Class F performance use BASF "Sonolastice NP111" adhesive or Henkel "PL® Polyurethane
Roof&Flashing Sealant",in accordance with CertainTeed requirements.
NEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization x32455 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)6S3-5847 Revision 14:01/24/2018
Page 11 of 13
NEMO I etc.
6.12 HIGHLAND SLATE'",HIGHLAND SLATE'"IR:
LOW AND STANDARD SLOPE: STEEP SLOPE:
T r s• Use FINE nails and BIGHT spots of asphalt roofing cement*for each
00
adOeM+
Mo—) (zJemn) MO—) full Highland Slate shingle.For Miami-Dade,SIX(nils are required.
Apply t'diameter spots of asphalt roofing cement under each tab
t' corner.Asphalt roofing cement meeting AS7M D4586 Type 0 is suggested.
(240 mmj
r
Rs mm( a5 mm)
Namo-Derle reouires
SIX nails(two nags t'(25 mm) ——
inslelled over cenler
anout as shown). _ Moni-Daft requires
SIX Mills(eru Mile 1 - :•�
ifMeBkA oVar Gnlpl
neae M.tK Roofing Cement
Figure 11-3:Use FIVE milt for every Migbland 57ate sbingle.
Figure 11-3A-Use FIVE nails and eigbt spols ofaspbalt
roofing cement under each tab corner.
'CAUTION:Excessive use of roofing cement can cause shingles
to blister.
6.12.1 Hip&Ridge for Highland Slate'",Highland Slate'""IR: Refer to instructions herein for Cedar Crest'",Cedar
Crest"IR or Shangle Ridge'"hip and ridge shingles.
6.13 PATRIOT":
LOW AND STANDARD SLOPE STEEP SLOPE
Use FOUR nails for every full shingle located as shown below. Use FOUR nails and four spots of asphalt roofing cement for every full
shingle as shown below.Asphalt roofing cement meeting ASTM D4586
Type 11 is suggested Apply 1'(25 mm)spots of asphalt roofmg
Sealant cement as shown.
1-275
(5--;�7 CAUTION:Excessive use of roofing cement can cruse shingles to blister.
lfl/d'
p56 mm)
4i15'I�1'RS win) 1'(2S ems
nwmlu t• _ e e
T Heeling Cement
f~ ) tmi A x
6.13.1 Hip & Ridge for Patriot": Refer to instructions herein for Cedar Crest^", Cedar Crest"" IR, Shadow Ridgem,
NorthGate or Shangle Ridge'"hip and ridge shingles.
7. LABELING:
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1/R905.2.6.1.
NEMO ETC,LLC Evaluation Report 3532.09.05-R34
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 12 of 13
ONEMOjetc.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this
product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409;karen.buchmann@us.ul.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization#32455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FLS444-1113
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 13 of 13