Loading...
HomeMy WebLinkAboutProduct Approval Business s. ProfessionalRegulation BCIS Home s Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications { FBC Staff SCIS Site Map } Links j Search Product Approval 4USER: Public User - -- RECEIVED ? 7r�'rrEinHrt." i Product Approval Menu > Product or Application Search > Application List> Application Detail 1 12018 P, FL # FL10674-R13 ntv, Permittinq Application Type Revision Code Version 2017 Application Status Approved FILE CO'rl Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Summary of Products FL # W Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge shingles Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674_R13_II_2017_10_FINAL_ER_OC_ASPHALT Approved for use outside HVHZ: Yes SHINGLES_FL10674-R13.pdf Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE - 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. I Evaluation Reports # FL10674_R13_AE_2017_10_FINAL_ER_OC_ASPHALT I SHINGLES_FL10674-R13.pdf `L Created by Independent Third Party. Yes Contact Us :: 2601 Blair Stone Road,Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: rivacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead,contact the office by phone or by traditional mail. If you have any questions,please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes,effective October 1, 2012, licensees licensed under Chapter 455,F.S. must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455, F.S., please click here. Product Approval Accepts: ® Cl ® Ed M Credit Card Safe EXTERIOR RESEARCH&DESIGN, LLC. wL Certificate of Authorization 119503 JTRINITY r ERD 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 (203)262-9245 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-118 One Owens Corning Parkway F1.10674-1113 Toledo, OH 43659 Date of Issuance:02/06/2012 (740)404-7829 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: @P�c"se's";:•'<�•; :b L The le l appearing horized Robert J.M.Nieminen,P.E. y Robert ;r j;; v��PNleminen,1P.Es oan 10/09/2017aThis tdoes nobserve as an Florida Registration No.59166,Florida DCA ANE1983 electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD 5.4 Wind Classification: S.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to V,,d = 150 mph (V„i, = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to V,,d= 150 mph (V,,,,= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category 8 or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: Berkshire.shingles require minimum five(5) nails per shingle. WeatherGuarda HP shingles require minimum six(6)nails per shingle. Devonshire'TM shingles require minimum six(6)nails per shingle. Starter Strip Shingle and Starter Strip Plus require minimum five(S)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.S Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Feitundedayment Desk Fskundedavmern Deck .rod .•>. Setf•srNsernl ' Wwwarlaym�ent _ Weatherl.ock' 1 'underlayment Drip edge Drip_ ',.. Drip edge Drip— edge edge _ ab located Nails!orated 2"a"from eave 2"-3"from eave Install first Selfisealin adhesive Selbaasling ednasive Starter Stri .• oaitioneda lon eave lnn+g tint Starter Sxip Plus -'' positioned along save p P g with 6"removed _. - ' '' shingle with \ 6"removed ` Starter Strip shingle overhangs eaves and rakes t�" 1' Starter Strip Plus overhangs eaves and rakes 1l�'-7!4' Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6TM EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 •--J TRINITY ERIC 6.2.8 Minimum Nailing—Devonshire'"": 7' 7„ I 8„ F 8„ I 8" I 7" I �„ Gems Naks 5^5/8'exposure Sealant location E2posici6n de 5.518 pulp Sealant del seliador Ten 1"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration°, TruDefinition® Duration, Duration® Premium Cool & TruDefinition" Durations Designer Color Collection: 4-Nail Fastening Pattern _ 6-Nall Fastening Pattern I—sure"M rasanNp ens wiWN r sur*Na W fnt."n W&to NYI,>m NW,,Typtcw t 12 I 12" '11' 1' 12^ 12 1' e-vr� I 4 6-its^ Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 N 11,Typigl 1 12" ijj(j 12 5- -t e.ve-s.vs^ fou 1-S00%of AxpWl eoen„g C-t Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof shingles Revision 8:10/09/2017 Page 5 of 8 .� TRINITY ERD 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuardm HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidgel Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.t ---------_�--- FID,2 --- -----� Top View StleVlew A Has N>tlh \ '�- I I 1° T Top LattvulYd A I 1 Wr>:e �► A I I 1 1 1 I I 1 A I I 1 1 I A t WI 1 1 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig.A vrovs� WIIM — 44 TopVbw A` I A i I Willis iWY I 3" A I I I b V, EYpOSUfe 12' ----� Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8