• FL# FL11480-R11
Application Type Revision RECEIVED
Code Version 2017
Application Status Approved
MAY 1 1 ?1318
Comments
Archived ❑ ST. Lucie County, Permitting
Product Manufacturer Solatube International,Inc
Address/Phone/Email 2210 Oak Ridge Way
Vista,CA 92081
(760)597-4427
tnderson@soiatube.com
Authorized Signature Todd Anderson
tanderson@solatube.com
Technical Representative Todd Anderson
Address/Phone/Email 2210 Oak Ridge Wa
Vista,CA 92081
(760)597-4427
tnderson@solatube m
IL' COP
Quality Assurance Representative
Add ress/Phone/Ema II
Category Sky Lights
Subcategory Skylight
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.Amoruso,P.E.
the Evaluation Report
Florida License PE-49752
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/25/2022
Validated By Steven M.Urich,PE
2 Validation Checklist-Hardcopy Received
Certificate of Independence FL11480 RS1 COI CI 417-0905 SolatubeSkvllahts ss.odf
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA 101/I.S.2/A440 2011
ASTM E1886 2005
ASTM E1996-2012a 2012
ASTM E283 2004
ASTM E330 2002
ASTM E331-00(2009) 2009
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL11480 R11 Eouiv EER 1971 Rev5 417 0905 SOLA0004-
SOLA0013 ss.odf
FL11480 R11 Eguiv EER 1973 Rev4 SOLA0005 ss.odf
FL11480 R11 Eauiv EER 2167 Rev4 SOLA0008 ss,odf
FL11480 R11 Equly EER 2396 Rev2 M74 DS Curb Mount Ooen
Ceiling ss.gdf
FL11480 R11 Eauiv EER 2397 Rev2 M74 DS Curb Mount with
Ampllfier ss.odf
FL11$Q R31Eauly EER 2399 Rev2_Solatube 160 290 DS TDD ss.odf
FL11480 R1I Eauiv EER 2400 Rev2 Solatube 330DS 750 DS
TDD ss.odf
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 02/07/2018
Date Validated 02/07/2018
Date Pending FBC Approval 02/15/2018
Date Approved 04/10/2018
Summary of Products
FL# Model,Number or Name Description
11480.1 160 DS TDD Impact 160 DS(10")Tubular Daylight Device-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 R11 II SOLA0004 RevE 160DS-290 DS ss odf
Approved for use outside HVHZ:Yes Verified By: Robert 3.Amoruso,P.E. FL License No.49752
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: +70/-70 Evaluation Reports
Other: FL11480 R11 AE PER 1971 Rev5 417-0905 SOLA0004-
SOLA0013 ss.odf
Created by Independent Third Party: Yes
11480.2 16C DS TDD Non-Impact 160 DS(10")Tubular Daylight Device-Non-
HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11480 R11 I] Model 160 DS TDD-Product Drawing
Approved for use outside HVHZ:Yes Packaae.odf
Impact Resistant: No Verified By: Robert 3.Amoruso,PE FL PE No.49752
Design Pressure: +70/-/0 Created by Independent Third Party:Yes
Other: Evaluation Reports
FL11480 R11 AE PER 2399 Rev2 Solatube 160 DS-290
DS TDD ss.odf
Created by Independent Third Party: Yes
11480.3 �290DSTDD Non-Impact 290 DS(14") tubular Daylight Device-Non-
HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11480 R11 11 Model 290 DS TDD-Product Drawing
Approved for use outside HVHZ:Yes Package.gdf
Impact Resistant:No Verified By: Robert 3.Amoruso,PE FL PE No.49752
Design Pressure: +70/-70 Created by Independent Third Party: Yes
Other: Evaluation Reports
FL11480 R11 AE PER 2399 Rev2 Solatube 160 DS-290
DS TDD ss.odf
Created by Independent Third Party: Yes
11480.4 290 DS TDD Impact 290 DS(14")Tubular Daylight Device-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 R11 II SOLA0004 RevE 160DS-29ODS ss.odf
Approved for use outside HVHZ:Yes Verified By: Robert J.Amoruso,P.E. FL License No.49752
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: +70/-70 Evaluation Reports
Other: FL11480 R11 AE PER 1971 RevS 417-0905 SOLA0004-
SOL-A0013 ss.odf
Created by Independent Third Party: Yes
11480.5 300 DS I DD Impact 300 DS(14")Tubular Daylight Device-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 R11 II 300 DS SKYQIGHT M1 FACTURER_a
Approved for use outside HVHZ:Yes INSTALLATION DETAIL PACKAGE.pdf
Impact Resistant:Yes FI 11480 R11 II SOLA0013 RevO 30ODS ss.odf
Design Pressure: i 70/ 70 Verified By: Robert J.Amoruso,PE FL PE No.49752
Other: Created by Independent Third Party: Yes
Evaluation Reports
FL1148Q R11 AE PER 1971 Rev5 417-0905 5OLA0004-
SOLA0013 ss.pdf
Created by Independent Third Parry:Yes
11480.6 330 DS TDD Non-Impact 330 DS(21 )Tubular Daylight Device-Non-
HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ: No 1`11_1148Q R11 11 Model 330 DS TDD-Product Drawing
Approved for use outside HVHZ:Yes Package.pdf
Impact Resistant: No Verified By: Robert J.Amoruso,PE FL PE No.49752
Design Pressure: +70/-10 Created by Independent Third Party: Yes
Other: Evaluation Reports
FL11480 RI AE PER 2400 Rev2 SQlatube 33OD5 750 DS
TDD ss.pdf
Created by Independent Third Party: Yes
11480.7 750 DS TDD Non-Impact 750 DS(21")Tubular Daylight Device-Non-
HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:No FLIA480 R11 II Model 750 DS TDD-Product Drawing
Approved for use outside HVHZ:Yes Packaae.pdf
Impact Resistant:No Verified By: Robert J.Amoruso, PE FL PE No.49752
Design Pressure: +70/-70 Created by Independent Third Party: Yes
Other: Evaluation Reports
FL11480 R11 AE PER 2400 Rev2 Solatube 33005 750 DS
TDD ss.pdf
Created by Independent Third Party:Yes
11480.8 750 DS TDD Impact 750 DS(21')Tubular Daylight Device-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 R11 II SOLA0005 RevD 750D5 5s odf
Approved for use outside HVHZ:Yes Verified By: Robert J.Amoruso,P.E. FL License No.49752
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: +70/-70 Evaluation Reports
Other: FL11480 RIJ AE PER 1973 Rev4 SOLA0005 ss.Ddf
Created by Independent Third Party: Yes
11480.9 Smart LED Smart LED 10"Tubular Daylight Device-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 R11 II SOLA0008 RQvC ss.Ddf
Approved for use outside HVHZ:Yes Verified By: Robert J.Amoruso,P.E.49752
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: +70/ 70 Evaluation Reports
Other: FL11480 R11 AE PER 2167 Rev4 SOLA0008 ss odf
Created by Independent Third Party:Yes
11480.10 Solatube M74 DS Curb Mount Open Solatube M74 DS Curb Mount Open Ceiling TDD- Dual
Ceiling TDD Glazed-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 R11 II M74 DS-O-DPP-FC-B-L2-REG FBC-
Approved for use outside HVHZ:Yes PFR2396 ss odf
Impact Resistant:Yes Verified By: Robert].Amoruso,P.E. FL License No.49752
Design Pressure: 1-80/-80 Created by Independent Third Party: Yes
Other: Evaluation Reports
FLi 1450 RIS AE PER 2396 Rev2 M74 DS Curb Mount
Open Ceiling ss.odf
Created by Independent Third Party:Yes
11480.11 Solatube M74 DS Curb Mount Open Solatube M74 DS Curb Mount Open Ceiling TDD-Single
Ceiling TDD Glazed -HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 R11 II M74 DS-O-DP-FC-B-L2-REG FBC
Approved for use outside HVHZ:Yes PER2396 ss.odf
Impact Resistant:Yes Verified By: Roberti.Amoruso,P.E. FL License No.49752
Design Pressure: +-80/-80 Created by Independent Third Party:Yes
Other: Evaluation Reports
F1 11480 R11 AE PER 2396 Rev2 M74 DS Curb Mount
Open Ceiling ssydf
Created by Independent Third Party: Yes
r1l80.12
Solatube M74 DS Curb Mount Open Solatube M74 DS Curb Mount Open Ceiling TDD with
Ceiling TDD with Amplifier Amplifier-Dual Glazed-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 R11 11 M74 DS-O-DPP-FC-A-L2-REG FBC-
Approved for use outside HVHZ:Yes PER2397 ss.odf
Impact Resistant:Yes Verified By: Robert J.Amoruso,P.E.FL PE No.49752
Design Pressure: +80/-80 Created by Independent Third Party: Yes
Other: Evaluation Reports
FL11480 R11 AE PER 2397 Rev2 M74 DS Curb Mount
with Amplifier ss.odf
Created by Independent Third Party: Yes
11480.13 Solatube M74 DS Curb Mount Open Solatube M74 DS Curb Mount Open Ceiling TDD with
Ceiling TDD with Amplifier Amplifier-Single Glazed-HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL11480 R11 II M74 DS-0-DP-FC-A-L2-REG FBC-
Approved for use outside HVHZ:Yes PER2397 ss.Ddf
Impact Resistant:Yes Verified By: Robert].Amoruso,P.E. FL PE No.49752
Design Pressure: 1-80/ 80 Created by Independent Third Party:Yes
Other: Evaluation Reports
FL11480 R11 AE PER 2397 Rev2 M74 DS Curb Mount
with Amplifier ss.odf
Created by Independent Third Party:Yes
Badee
Contact Us;:2601 Blair Stone Road Tallahassee FL 32344 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Couyriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses arc public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The
emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an.email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
Credit Card
Safe
g :• � a tr v N �
a� HMO i IM ,g x,191 iMM
y
o �
o V
xr n
pil im i si 1
P ie _ a mWj = S yy
11111 MIT!
° n �
tT gig
om
11M.u
� �g�g
oFa w;oIA. 3 uR o
F o
> b
°
o>� SOLATUBE INTERNATIONAL 617-0603
2210 OAK RIDGE FAY c NM a ROR O roe +0/17/17 tw
111, CA 82081-11341 r o UM TO sot
s/tt/ty JN
,o
ddo f"tiz
IMPACT 160 OS (10 & 2110 DS (14") ne�sm nrv�nows
F t=r?s.�1 TUBULAR OOAAYL GHT DEVICE c oyo/1y,yw
g Q 99Y R--HORS"
g 4 1'0\wf.:: ��—'�_'`SMC d�10 08 Ofi B 4/14/14 RA%
I^ =ewe N.T.S. �wSOLA0004 rac 12/13/11 Tim
E 1 OF 6
A g s
-
71 NOM ` \
-._.._... 75 76 1. SMUMMEIEM905OLTNOOD.tYR6 DRYWAUFFC.)
fFSTENERS RT O,NERt6 SNOWN/OR EOBMICE ONl11 n n
23 7. ALLIDM X)MSR SEAMS SeMefrINTrOILTAK(MCYSNOWN) f
l SE!PAGE{FOR ANSMAIE DAHEI COMSWGigNSi�
4. IIBA az MC7ANCAgM FOM ON MONT MAD
FLASHING SHOWN WITH OPTIONAL E
748'TALL TURRET EXTENSION
0
0
1 .0 17 16 70
10 DETAIL B
t� Olp U Vi
TUBE w 1 W ga mp 41� s� z
E- R m o {
Y ��+ � RR{jt+j+
26st
w 13 41.1 a
L 19 s EO-
6
S
S ,S�LLRa��
w _
-�wt��rrsnnuaDrast+a:xr 6
.ate
---
/,.
ue
/' Robert J.Amonna,P.E.
FIL PAL No.49 152
6C-NhIFA - FMGII�—"' �'
DETAIL C
Digitally signed by
r �rAtwe. —se
Robert J Amoruso
Date:2017.10.19
16:04:36-04'00'
290 DS (14") FLASHING OPTIONS
o a a
b
015.9 TOP OF FLASHING
R
15.9 23.3
61 TOP OF FLASHING 8.7 g
- 6.1
18.0 �
9.2 6.0 18.0 d
o ' b
z og� o
E+ a
1-y v F b
g�
23.3 8.7 O .C4
zLi
Li
e m
FLAT 6"
PITCHED E-'
z U !!
1
8X FLASHING FA51131ER5 ,D r 3
FLASHING FASTENER SPACING E Pa
Z �d�
FLAT ,FLAT 6-i PIPCHED I �p
1 TOPFLAor,
NG o
0 5.9
015.9 TOP OF
[FLASHING
BX FLASHING FASTENERS, 6.1
ZX FASTENERS PER SIDE
6.2 2.0 40
180
18.0 N"hen J.Mbnna.P.E.
FL P.E.N�ow499752
Digitally signed by
FLAT 4" CURB Robert J Amoruso
Date:2017.10.19
16:04:24-04'00'
160 DS (1(Y") FLASHING OPTIONS o a n a a
O
011.9 ,! b o
011.9 TOP Of FLASHING n
roP of FLASHING E�a g�
5.0 -
5.0 t
6.0 SX FLASHING FASTENERS §
4 16.6
20A Q $
z
0 0� o
8.1 a oy0 v
FE- I
'
FLAT 6' Z m $E�
HO U n
.00
W
PITCHED 20.0 e I O Z < �I
�e
MN s f"3
t0 j
1LD
FLASHING FASTENER SPACING A�
FLAT C,FLAT 6-&PITCHED O `e E
M
011.9-7roP OF HASHING
TOP OF FLASHING
50 4.02A 4.0
14.8 16.6
Robert J.Amd 'P.E.
FL P .No.IM2
�ti Ems
RXFLLSRINGFASTENERS,
FLAT 4" 2X FASTENERS PER SIDE Digitally signed by
CURB Robert J Amoruso
Date:2017.10.19
16:04:09-04'00'
160 DS (10") AND 290 DS (14") 290 DS (14") DECORATIVE a s
DECORATIVE FIXTURE OPTIONS FIXTURE OPTIONS R
e
'JUST FROST'DECORATIVE p g g
FIXTURE ASSEMBLY
'AURORA GLO'DECORATIVE
FIXTURE ASSEMBLY t.4
o�._a
z m `
N 41
W
E-
Z �
TIER DROPDECORATIVE ( OPTIVEW DECORATIVE
FIXTURE ASSEMBLY 1 FIXTURE ASSEMBLY H
.un l.m.a.wa,imar m.o.wrs E''
mt w]. tm oawmr p wmw a
.wnx toa I
tai t'p1Pa }LM8}nm 414
2 (D— O
I
\� Ylalt p0 MLLfm•ibiltr t%rnOYO/6
p�
]
I
1 4 1 D Robed I A--,P.
R P.E No.49752
+u trer Aiwa Amir tarnans 4n.v wnev.tmnr aoraaa Y�..h1.
nd b tm. acunw �two}w � tm. uvns ria ��"�
peC 1D6 t na11F 11tr 1tn IOOC a—
] 1 •OIeC lAt ew KMNK } t E]il®I nu¢ }C 1§�,�� �t
J 1 McIG aY RK AaMG }� J 106 n tYot 1<m j`�fy�l.4.`'�'0't�
Digitally signed by
Robert J Amoruso
Date:2017.10.19
16:03:40-04'00'