HomeMy WebLinkAboutProduct Approval Understanding Thermal Properties
Qn Glass Performance
Solar Heat Gain Coefficient(SHGC)
measures how much heat from the sun is blocked.
The Lower the SHGC,the more the skylight is,
blocking heat entering the living space.
U-Factor
INS, • 0>SHGC>1'
measures how
9� 0 we IL your • lower is better
✓ skylight prevents heat from
escaping a living space.
- 0.15>U factor>1.20
- tower is better
Visible Transmittance(VT) Ultraviolet Light(UV)
measures how much Light comes considered the energy that accounts
/-V through the skylight. for the majority of fading of materials
r 0>VT>100% and furnishings.
• Personal Preference 0>UV>1
• lower is better
rf
Insulated Glass Thermal Properties Comparison
rr-;-7--_ ,7-` --7, —
Y-FiC
or SHGC' SVT p UV
Single Pane, Clear, 1.04 .86 90% .73
L,ko I Q t�Te
Low-e/CLrTemp w/Argon .30 .72 76% .50
L6E 2 240%ClrTem0,:w/'A-rgpn
39 /a
U11 =424
1
9/
W
.4oe��,'340/Cir-Temp,-vu/Argon-,,' 04
Condensation
w. Condensation in your home is caused by excess humidity or invisible water vapor in
the air.The warm air in your home can hold large amounts of this water vapor(much
more than cold air).When the moisture-laden warm air comes in contact with a cool
surface,the vapor condenses to form actual water droplets.This is the cause of the
condensation you see on the inside of your skylights or windows.The Lower the
U-Factor&SHGC thermal numbers,the better result reducing condensation.
1-800-33, -5854 ,
NmNm� Lough�
An ,
wh@T@ @—U
O .
Wan� Ugh V -. . .....w
�x
You won't believe the
difference skylights make. in
our home.
, �.� -
For more than 35 years our All American Table ofContents,
WhySun-Tek? .............................................. �y
Made skylights have been making
Understanding Glass Performance............4 R
homes look brighter and more cheerful '
r How Do I Measure?.......................................6
and even bigger.You ,
s = How Do I Choose ? ..........7
get more than your:`- "'.
Self Flashing Glass
money's worth
' Curb Mount Glass .. 10
r .........................................
Sun-Tek Glass,
Self Flashing Polycarbonate........................ 12
Polydome, Extreme Curb Mount Polycarbonate.......................... 14
Weather and
' . �' � Skylight Accessories................. . - ....-16
Sun-Tek's Tubular
Vented Accessories................................... 17
F
Skylights really look
Sun-Tek Tube°................................................. 18
great and add value Spyder' Multi-Tube Systems..................... 20
to your home. Commercial Skylights................................... 22
liq� K�4 7+1 Ata •® O O
www.Sun-Tek.com 3
Our Promises Hold Water
Sun-Tek makes you a promise- to be water tight!We select the best materials available.We ',
study structure and design.We commit to ease of installation,-durability of.materials,maximized
energy conservation and no water. Very simply, NO WATER.
Concerned about more then roin drops? {
Our Glass Skylights are available in various . ,
ro�
combinations of LoE3„340 over Clear
i Tempered, Laminated or impact.
* Our Polycorbonote Skylights are produced
from high impact resin that is 30 times
stronger than acrylic. '
• Our Extreme Weather Skylights have the
widest and most complete range of hurricane e
& high velocity impact units of any skylight } !
manufacturer to date! - 6
Ease of Installation
k^J
With the rough opening prepared,an experienced .
roofer can install a Sun-Tek skylight- start to finish -in 15-minutes.Labor
savings are multiplied with each installation. a �
Uk
i
)” 1
That`s Whyl
From the Sun-Tek Tube... to insulated Glass... to Polycarbonate e
Sun-Tek can offer the right application for any wind zone or ;AP
environmental requirement.
Install Sun-Tek Skylights.Then relax. Let it rain...or snow...or hail.. or',! .m
blow.You are safe under a canopy of sky. y o a -o
21 1;-800-334-5854
I'll-I I- L
S K Y L I HTS R
AU
a. {
E ; 1
} a
key `�,Y•..v 4%d
f �t p
r
t 5'
t
Skglghts &
Tube Skylight
.J Stems
r
ria;`
h ,
MIAMDADE MIAMI-DADS COUNTY
• PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami,Florida 33175-2474
NOTICE OF ACCEPTANCE (NOA) T(786)315-2590 F(786)315-2599
Sun-Tek Manufacturing,Inc.
10303 General Drive.
Orlando,FL 32824
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
I
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have
this product or material tested for quality assurance purposes. If this product or material fails to perform in the
accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,
modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke
this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material
fails to meet the requirements of the applicable building code.
1
This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane
Zone of the Florida Building Code.
DESCRIPTION: ICMG Skylight System
APPROVAL DOCUMENT:Drawing No. STI-00000290,titled"ICMG", sheet 1 &2 of 2,prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007,with last revision"A", signed and sealed by James D. Wells, Jr.,P.E.,
on October 06, 2017, bearing the Miami-Dade County Product Control Revision stamp with the Notice of
Acceptance number and the.expiration date by the Miami-Dade County Product Control Section.
MISSILE I1vIPACT RATING: Large and Small Missile Impact Resistant
LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state;model/series
and the following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall
be done in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and 1
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#15-0513.09 and consists of this page 1, evidence submitted pages E-1,E-2,E-3 &E-4 as
well as approval document mentioned above.
The submitted documentation was reviewed by Helmy A.Makar,P.E.,M.S.
MIAMI•DADE UNTY ! �Q
NOA No. 17-1023.21
CO
� o Expiration Date: 10/10/2018
o Z/ ? -L/Z o Approval Date: 02/22/2018
8 Page 1
I
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#07-0425.05
A. DRAWINGS
1. Drawing No. S7I-00000290-SHTIISHT2, titled "ICMG", sheet 1 & 2 of 2,prepared by Sun-
Tek Manufacturing, Inc, dated 06104107, with last revision dated 08107107, signed and sealed
by James D. Wells,Jr., P.E.
B.. TESTS (submitted under NOA#02-0729.07)
1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per
PA 203 and Uniform Static Air Pressure Test per PA 202 of "Model ICMG 4949
Insulated Glass Skylight with Polycarbonate Inner Liner" prepared by National
Certified Testing Laboratories, Report No. 210-2789-1, 2 & 3,. dated 03118102, signed
and sealed by B. Portnoy, PE
C. CALCULATIONS
1. Anchor Calculations for attachment of skylight to cubing and curbing to decking, dated
08113107, signed and sealed by James D. Wells, Jr., P.E.
D. MATERIAL CERTIFICATIONS (submitted under NOA-#02-0729.07)
1. Die drawings No. STI-214 of Deco Ring, prepared by Sun-Tek Manufacturing, Inc. on
6119195.
2. Die drawing No. STI-205 of Curb Frame prepared by Sun-Tek Manufacturing, Inc. on
12126196.
E. STATEMENTS (submitted under NOA#02-0729.07)
1. Code compliance and No-Interest letter issued by Product Technology Corporation on
08/27102, signed and sealed by R. J Quiroga PE
F. OTHER
1. NO.4 renewal request letter issued by Sun-Tek Manufacturing, Inc., dated 08116/07, i
signed by James Feudner.
1
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL# 1170601.03 i
A. DRAWINGS
1. Drawing No. STI-00000290-SHTIISHT2, titled `ICMG", sheet I &2 of 2, prepared by
Sun-Tek Manufacturing, Inc., dated August 07, 2007, with last revision "A" dated
October 14, 2011, signed and sealed by James D. Wells, Jr., P.E.
elmy A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No. 17-1023.21
Expiration Date: 10/10/2018
Approval Date: 02/22/2018
E-1
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS
1. Test Addendum for Test Report NCTL 210-2760-1, prepared by national Certified
Testing Laboratories, dated October 17, 2011, certifying the interlayer thickness,
signed by Mark Bennett, Manager of Testing Services (see NOA#11-0601.02).
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Permitting, Environment, and Regulatory
Affairs(PERA).
E. MATERIAL CERTIFICATIONS
1. None.
3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL# 12-1011.16
A. DRAWINGS
1. Drawing No. STI-00000290, titled "ICMG", sheet I & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007, with last revision "A" dated May 03,
2012, signed and sealed by James D. Wells, Jr., P.E.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. OTHERS j
1. A compliance letter, prepared by J & L Wells Consulting LLC, dated April 25, 2012,
certifying compliance with FBC 2010 edition, sign and sealed by James D. Wells, Jr.,
P.E.
2. Verification testing to be performed per letter from National Certified Testing
Laboratories, dated September 18, 2012, signed by Christopher Bennett.
9
ClI
elmy A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No. 17-1023.21
Expiration Date: 10/10/2018
Approval Date: 02/22/2018
E-2
1
t
l'
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
4. EVIDENCE SUBMITTED,UNDER PREVIOUS APPROVAL# 13-1010.09
A. DRAWINGS
1. Drawing No. STI-00000290, titled "ICMG", sheet 1 & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007, with last revision "A" dated May 03,
2012, signed and sealed by James D. Wells, Jr., P.E.
B. TESTS
1. Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure Test per
PA 203 and Uniform Static Air Pressure Test per PA 202 of "Model ICMG 4949
Insulated Glass Skylight with Polycarbonate Inner Liner" prepared by National
Certified Testing Laboratories, Report No. 210-3915-02, dated 09/13113, signed and
sealed by Gerard J. Ferrara, P.E., on 09/24/13.
2. Revised Test Report on Large Missile Impact Test per PA 201, Cyclic Wind Pressure
Test per PA 203 and Uniform Static Air Pressure Test per PA 202 of "Model ICMG
4949 Insulated Glass Skylight with Polycarbonate Inner Liner"prepared by National
Certified Testing Laboratories, Report No. 210-3915-02, dated 09/13/13, revised on
02/26/14, signed and sealed by Gerard J. Ferrara, P.E., on 02/28/14.
C. CALCULATIONS
1. Anchor Calculations for attachment of skylight to cubing and curbing to decking, dated
10/03/13, signed and sealed by James D. Wells, Jr., P.E., on 10/03/13.
i
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
5. , EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL#15-0513.09
A. DRAWINGS
1. Drawing No. STI-00000290, titled "ICMG", sheet 1 & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007, with last revision "A" dated May 04,
2015, signed and sealed by James D. Wells, Jr., P.E., on May 04, 2015.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
14.dzzz�,
CI- Helm'y A.Maliar,P.E.,M.S.
Product Control Section Supervisor
NOA No. 17-1023.21
Expiration Date: 10/10/2018
Approval Date: 02/22/2018
E-3
I
I
Sun-Tek Manufacturing,Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
6. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. STI-00000290, titled ".ICMG", sheet 1 & 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated August 07, 2007, with last revision "A", signed and sealed
by James D. Wells, Jr., P.E., on October 06, 2017.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
i
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. - None.
i
i
F. OTHERS
1. A compliance letter,prepared by J&L Wells Consulting LLC, dated October 06, 2017,
certifying compliance with FBC 2017 edition, sign and sealed by James D. Wells, Jr.,
P.E. #
1
i
Helmy A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No. 17-1023.21
Expiration Date: 10/10/2018
Approval Date: 02/22/2018
E-4
PRCIDUCTREVISED
xn compl)ving:cath tbo.Flopida
B�.Itfdhlg OcRic
axDiaztion 01fic
PART NAME:ICMG SKYLIGHT PLAN VIEW I FILEN E:H:1DWGVV4ACAD2000DRAWNGS\DADE COUNTY ICMGSTI-00000290-SHT2 I SHEET 2 OF 2 1 DWG.NO.STI-00000290-SHT2
By
51,375 '14i DESIGN PRESSURE RATING 180 PS SILICONE BEDDING(CONrINUOS) DECO RING 0.050 SUST-45ALUMN"M
Max. V ACT RESISTANCE DECOCUPO.075 MR BRED AND WRAP AROUND
L
F RSONAT
SILICONE POLYCARBONATE BOTTOM OUTBOARD GLASS
OSS TZAPERED(Ira!)
O
(CONWNUDS)
10.84375-1 M3 1 1 5.
P�Xj bCA Wd
4.00— Engineer of Record da
400 4,00
�7113.84375 T 10-84375 10.8431 James D.Wells,Jr.,P.E. 0.j25X2'ALUMNIUMFLXrBAR
Professional Engineer No.53616 --e—EDCORNERS INBOARD DSB
GASKET STRIMASS IrEMPEREDI!IX)
STI-206(oZINTERE
J&L-Wells Consulting LLC ANDWELDEDCORNERS WOOD LINER
(CMG 4949 1 7.23 1453 Arbitus Circle 012 X r P ILUPS FAN
- ___1
HEAD SCREW
#l2X2PHILLIP$P HD SCREW Y Oviedo,Ft.32765
(407)496-5489 V2 X:1 112 d—d�ed PVC
7,23 FLASRWGBYOTHFRSN I—lap.
FASTENED SKYLIGHT TO CURB VM t A u t h o r i z a tio n ACCORDANCEWTHNR
CA
010X2.92-DECK SCREW
;'0! 48)PER SIDE
4"mn er OTHERS(APPROVi5l)
LIGHT TUNUEL E..1
(5)PER SIDE
98-32 x 314 BOLT W1 NUT ATTACHES BY OADE COUNI
FRAME TO ALUMINUM aAR
61.375 (7)PER SIDE roof surface to lip ROOFIMPSIFELT,�'
No. 53616max
SHINGLES(1)
7-2=—'V- 11 I%= "—2X CURB HEIGKTTO BE SUFFICIENT TO
iju LIAINTAN 4'FANMU%I CLEARANCE
DAYLIGHT OPENING 2 BETWEEN ROOF SURFACE AND
LOWEST UP OF FRAME CURB
45.5-(MAX)X 45.6'(MAX) Iq j. ont SUPPLIED BY OTHERS(APPROVED BY
31 VN STATE OF
CURB TO DECK FASTENERS
#10 X 2,5" '40MIDt- 11"I""'I"' SEALhNr mm
I/., -_ protrusion
447
9 9
"2'2 PHILUPSP -OSC'
FASTENED SKYLIGHT T_'LZ
f'3 PER S'e
K
344 BOLT I NUT ATTACHEI
To ALUMIZ'A MR
No -5-
Al
7.123
AU � 9R SCHEDULE SKYLIGHY_j�0 OUREI FASTENER SCHEDULE CURB FASTENER SCHEDULE
#12X2'PHILLIPS PAN HEAD ATO DECK SUB-FRAMETOFRAME
SCREWS alo X 2-117,DECK SCREWS 11832 BOLT%Y/NUT
TIP TO MODEL PER PER PER PER PER
TIP LONG SIDE SHORT SIDE LCINGSIDE I SHORT SIDE LONG SIDE SHORT SIDE
5.93 6.0- 4. 51.375 x 51,375 4940 5 5 8 a 7 7
48.375 x 48.375 4645 5 5 8 8 7 7
4.00 .376 x 51375 3349 5 4 a 6 T 5
N Of J 4.00 35.375%35.375 3333 —4 4 6 6
(1)ALL ROOFING DETAILS SHALL COMPLY V%fiTH 32.375x 48.375 3046 5 4 8 5 7 5
CHAPTER 15 OF THE 2017 FLORIDA BUILDING CODE 32.375 x 32.375 3034 4 4 5 5 5
(2)4'MINIMUM DISTANCE FROM ANGLE LIP TO ROOF 27.375 x Si 375 2549 6— 3 8 —6 -7 4
27.375 x 35.375 2533 4 P_ 6 5 5 4
SURFACE IS FOR SHINGLE OR B.U.R.WITHOUT 27.375 x 27,375 2525 3 3 5 5 4 4
—i—5 —3 —5
INSULATION.FOR INSULATION AND TILE ROOF ADD 24.375 x 48.375 2246 5 3 8 3 7 4
TILE HEIGHT AND INSULATION THICKNESS TO 4'. 24.375 x 32.375 4 3 5 3 5 4
(3)ANCHORS TO BE MADE FROM NON-CORROSIVE MATERIAL 24 375 x 24.375 2222 3 3 3 3 4 4
COMPATIBLE WITH ALUMINUM. tt_is x 51.375 1749 5 3 a 3 —7 3
(4)NO ONE-THIRD INCREASE IN THE DESIGN PRESSURE WAS USED. 19-375 x 35.375 1733 1 3 6 3 5 3
16.375 x 48,3 8 3 7
Y75 1 46 2
1376x32 2 —I
REVISPOK REVISION: RODUCTNAME: 1CMG I SUN-TEK MANUFACTURING, INC.
BY: DAY E: WY—. DATE: DRAWN BY: JVVF I DATE: 08105120111 DWG NO. STI-00000290-SHT2 REV. A_ j 10303 GENERAL DRIVE ORLANDO.FL 32824