HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
Business & Professional Regulation
BCIS Hone Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FSC Staff DCIS Site Map Links Search
s
db
r
�Product Approval
,. asst:Public user
Product Approval Menu>Pradutt or Application Search>Apolirathon list>Application Detail
FL* FL18355-114
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer TAMKO Building Products,Inc.
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri—eden@tamko.com
C� Authorized Signature Kerri Eden
Q kern eden@tamko.com
� F
Qc' Technical Representative Kern Eden
Address/Phone/Email PO Box 1404
�. Joplin,MO 64802
o (417)624-6644 Ext 2305
�z kerri_eden@tamko.com
V
v Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R.Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 01/07/2019
Validated By Locke Bowden
--I Validation Checklist-Hardcopy Received
Certificate of Independence FL18355 R4 COl TBP15001 4 2017 FBC Eval Report Shingles final.Ddf
0 Referenced Standard and Year(of Standard) Standard Yes[
ASTM D 3161 2016
ASTM D 3462 2010
ASTMD D 7158 2011
TAS 100 1995
UjEquivalence of Product Standards
J Certified By Approved Testing Lab
FL18355 R4 Euuiv UL letter for standards for FBC 2017.odf
U. Sections from the Code
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquvosrHazGXQ... 1/3/2018
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated 09/27/2017
Date Pending FBC Approval 10/08/2017
Date Approved 12/12/2017
Summary of Products
FL 8 Model,Number or Name Description
18355.1 Glass-Seal,Elite Glass-Seal, ASTM D 3462 asphalt shingles and hip and ridge shingles
Heritage,Heritage Premium,
Heritage Woodgate,Heritage
Vintage,Hip and Ridge,and
Vintage Hip and Ridge Shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL18355 R4 11 TBP15001.4 2017 FBC Eval Report Shingles
Approved for use outside HVHZ:Yes final.pdf
Impact Resistant:N/A Verified By:Zachary R.Priest PE-74021
Design Pressure:N/A Created by Independent Third Party:Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL18355 R4 AE TBPI5001.4 2017 FBC Eva[Report
Shingles final.pdf
Created by Independent Third Party:Yes
Back Nert
Contact Us.:2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The state of Flonda.s an WEED employer.Copvrwht 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,ema-1 addresses are public records.If you do not want your e-mail address released.n response to a public-records request,do not send
electrons mad to this en:.ty.Instead,contact the office by phone or by traditional mad.if you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an ema i address.f
they have one.The emads provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine.f you are a licensee under
Chapter 4S5.F.S.,please click here.
Product Approval Accepts:
Credit Card
Safe
https://www.floridabuilding.org/pr/pr app_dd.aspx?param=wGEVXQwtDquvosrHazGXQ... 1/3/2018
No.
CREEKCertificate of Authorization inb 2gh Dr
17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017)
Manufacturer: TAMKO BUILDING PRODUCTS Issued September 25. 2017
220 West 4" Street
Joplin, MO 64801
(417)624-6644
Manufacturing Plants: Joplin, MO
Phillipsburg, KS
Frederick, MD
Dallas. TX
Tuscaloosa, AL
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1504.1.1. 1507.2 5. 1507.2.7.1. 1523.6.5.1
Properties: Physical properties,Wind Resistance.Wind Driven Rain
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies(TST5878) TAP-043-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-051-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-054-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-114-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-117-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-130-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-131-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-165-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-280-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-303-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-307-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-314-02-01 Rev 2 TAS 100 1995
PRI Construction Materials Technologies(TST5878) TAP-315-02-01 ASTM D 6381 2008(2013)e1
PRI Construction Materials Technologies(TST5878) TAP-317-02-01 TAS 100 1995
UL LLC(TST9628) 02NK9507 ASTM D 3161 2016
UL LLC(TST9628) 04NK24366 ASTM D 3462 2010A
UL LLC(TST9628) 05NK28006 ASTM D 6381 2008(2013)e1
UL 2390
ASTM D 7158 2011
UL LLC(TST9628) 06NK03898 ASTM D 3161 2016
ASTM D 3462 2010A
UL LLC(TST9628) 08CA59132 ASTM D 3161 2016
UL LLC(TST9628) 09NK07896 ASTM D 3161 2016
ASTM D 3462 2010A
UL LLC(TST9628) 1 OCA50498 ASTM D 3462 2010A
UL LLC(TST9628) 1 OCA64882 ASTM D 3161 2016
UL LLC(TST9628) 11NK14014 ASTM D 3161 2016
ASTM D 3462 2010A
UL LLC(TST9628) 12CA24551 ASTM D 3161 2016
UL LLC(TST9628) 4786110543 ASTM D 6381 2008(2013)e1
UL LLC(TST9628) 4787043752 ASTM D 3161 2016
UL LLC(TST9628) 4787148748 ASTM D 7158 2011
ASTM D 3161 2016
ASTM D 3462 2010A
CREEK Technical Services LLC(ANE 11669) TBP15001 3 Calculations 2017
TBP 15001.4 FL18355-R4 Page 1 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid
This evaluation report does not express nor imply warranty. installation. recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite Glass-Seal(R) 12-1/4" x 36". ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick,Joplin& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462,
Glass-Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing. 3-tab
(Frederick& asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462,
Glass-Seal 12-1/4" x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass
(Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462 Shingles shall be used in the non-HVHZ only.
Heritage® 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin, Phillipsburg& complying with ASTM D 3462
Tuscaloosa)
Heritage®Premium 13-1/4" x 39-3/8", ASTM D 3161. Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick, reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg& complying with ASTM D 3462.
Tuscaloosa)
Heritage®Premium 12- x 36", ASTM D 3161, Class F and ASTM D 7158. Class H fiberglass reinforced.
(Frederick) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462
Heritage®Vintage® 17-1/2" x 40".ASTM D 3161, Class F and ASTM D 7158. Class H fiberglass reinforced.
(Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462
Heritage®Woodgate 13-1/4" x 39-3/8", ASTM D 3161. Class F and ASTM D 7158, Class H fiberglass
(Dallas&Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritage®Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161. Class F fiberglass reinforced. hip and ridge asphalt
(Frederick&Joplin) shingle surfaced with mineral granules complying with ASTM D 3462
Vintage®Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced. hip and ridge asphalt shingle
(Phillipsburg) surfaced with mineral granules complying with ASTM D 3462,
TBP15001 4 FL18355-R4 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
INSTALLATION
Elite Glass-Seal® Basic Wind Speed(V,,,,) Max 194 mph
(Frederick, Joplin& Basic Wind Speed (Vasd) Max 150 mph
Tuscaloosa) Deck (HVHZ): In accordance with FBC requirements,
& Solidly sheathed min. 19/32 in. plywood or wood plank for
Glass-Seal new construction, Min. 15/32 in. plywood existing
(Frederick, Joplin (Non- construction
HVHZ)&Tuscaloosa) Deck(Non-HVHZ) In accordance with FBC requirements:
Solidly sheathed min 15/32 in. plywood or wood plank for
new construction, Min 7/16 in. OSB existing construction.
Underlayment In accordance with FBC requirements.
Min. slope 2 12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation (HVHZ) Installed with 5-1/8 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below
Installation (Non-HVHZ): Installed with 5-1/8-inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either'4 Nail
Pattern'or"6 Nail Pattern"detailed below.
NAILS
Nailing ........--. . 6-7/8
_
n
A(Area -.. ............... _..__T.....
- �5-118..
136t Edge
Figure 1. Elite Glass-Seal &Glass-Seal
4 Nail Pattern (Non-HVHZ only)
NAILS
L
Nailing L :. - - .._.
---... ---------- .. ............. ..... _. 6-718"
Area ;I � ------------------ --- --- _ -----...-._..----�_.-....---...----------•----
5-1,'8"
Butt Edge
Figure 2. Elite Glass-Seal &Glass-Seal
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3 The manufacturer shall notify CREEK
Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty. installation, recommended use, or other product attributes that are not
specifically addressed herein
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES. LLC
Heritage® Basic Wind Speed (V,,,;): Max. 194 mph
(Dallas. Frederick. Joplin, Basic Wind Speed(Va,c): Max. 150 mph
Phillipsburg&Tuscaloosa) Deck(HVHZ): In accordance with FBC requirements.
& Solidly sheathed min 19/32 in. plywood or wood plank for
Heritage®Premium new construction; Min 15/32 in. plywood existing
(Dallas, Frederick construction.
Phillipsburg &Tuscaloosa) Deck(Non-HVHZ): In accordance with FBC requirements,
& Solidly sheathed min. 15/32 in. plywood or wood plank for
Heritage®Woodgate new construction, Min 7/16 in. OSB existing construction.
(Dallas&Frederick) Underlayment: In accordance with FBC requirements
Min. slope: 2 12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5-5/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ) Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either''4 Nail
Pattern"or`6 Nail Pattern" detailed below.
FASTENERS NAIL ZONE
COMMON
BOND
EXPOSURE 5-6/8"
1 12-1/2"- -- 12-3/8" - - 12-1/2` �1"
Figure 3. Heritage®, Heritage®Premium, and Heritage®Woodgate (Dallas)
4 Nail Pattern (non-HVHZ only)
FASTENERS NAIL ZONE
COMMON
11111117-1/BOND
6-1/8" EXPOSURE 5-5/8"
1'—►I ��-112"- r-i 12" 3l8"-►�-
1-1/2
Figure 4. Heritage®& Heritage®Premium
6 Nail Pattern
TBP15001 A FL18355-R4 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services.LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty. installation. recommended use, or other product attributes that are not
specifically addressed herein.
PRODUCTS
TAMKO BUILDINGAsphalt Shingles
TECHNICAL SERVICES. LLC
NAIL ZONE/
ASTENERS.7 COMMON BOND
6-1/8" FPOSURE 5 5!8"
I
�7-1/2+7-1/2'+7-3/8+7-1/2+1-1 i2;"I
Figure 5. Heritage®Woodgate
6 Nail Pattern
Id I
El Common Bond
FASTENERS
7
C.3
7 + ro t
1 Ln0
Ln 0
L6 7
CL (0
X
UJ
E
Figure 6. Heritage®, Heritage®Premium, & Heritage®Woodgate
Alternate 6 Nail Pattern
PAINT
LINE
7-7/8" ----------- -------------------- ---—----- NAI L ZON E
6-1/8" ----EDGE OF
COMMON
BOND
EXPOSURE
ACCEPTABLE
FASTENER LOCATION
DO NOT FASTEN
ALONG EDGE OF
----------------- ---------- COMMON BOND
PREFERRED
FASTENER
LOCATION
Figure 7. Heritage®(Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above
TBP15001.4 FL18355-R4 Page 5 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES. LLC
Heritage(R)Premium Basic Wind Speed (V,„) Max. 194 mph
(Frederick) Basic Wind Speed(Va,o) Max. 150 mph
Deck(HVHZ). In accordance with FBC requirements,
Solidly sheathed min 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ) In accordance with FBC requirements,
Solidly sheathed min 15/32 in. plywood or wood plank for
new construction, Min 7/16 in. OSB existing construction.
Underlayment In accordance with FBC requirements
Min. slope- 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ) Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using '6 Nail Pattern' detailed
below
Installation (Non-HVHZ). Installed with 5 in exposure in accordance with FBC
requirements and manufacturers published installation
instructions. Shingles shall be attached using either A Nall
Pattern"or"6 Nail Pattern"detailed below.
NAIL ZONE/
FASTENERS /COMMON BOND
51/1 EXPOSURE 5"
12" —►�— iv--— { �-1"
Figure 8. Heritage®Premium (Frederick)
4 Nail Pattern (non-HVHZ only)
NAILZONE.!
FASTENERS COMMON BOND
51/2" EXPQSURE 5"
Figure 9. Heritage®Premium (Frederick)
6 Nail Pattern
TBP15001 A FL18355-R4 Page 6 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
R, CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES. LLC
Heritage(H)Woodgate Basic Wind Speed (V,,,,): Max. 194 mph
,Frederick) Basic Wind Speed (V„,,,) Max. 150 mph
Deck(Non-HVHZ) In accordance with FBC requirements.
Solidly sheathed min 15/32 in. plywood or wood plank for
new construction, Min. 7/16 in. OSB existing construction
Underlayment In accordance with FBC requirements
Min. slope 2 12 and in accordance with FBC requirements Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21 12.
Installation (Non-HVHZ): Installed with 5 in exposure in accordance with FBC
requirements and manufacturers published installation
instructions. Shingles shall be attached using either'4 Nail
Pattern”or"6 Nail Pattern"detailed below.
NAIL ZONE/
FASTENERS COMMON BOND
5-112" EXPOSURE 5"
11" —►�-12-318"— - 11" —� [0-1"
Figure 10. Heritage®Woodgate (Frederick)
4 Nail Pattern (non-HVHZ only)
NA IL 20N E'
COMFAON BONG
FASTENERS
T T
5-117' EXPOSURE 5'
1"--►I � 9-1/2"�3'�►�-9�/8"�3�9-112"—� �1"
Figure 11. Heritage®Woodgate (Frederick)
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 7 of 11
This evaluation report is provided for State of Florida product approval under Rule 61620-3. The manufacturer shall notify CREEK
Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein
CREEK TAMKO BUILDING PRODUCTS
Asphalt shingles
TECHNICAL SERVICES. LLC
Heritage®Vintage® Basic Wind Speed(V Aj): Max. 194 mph
(Phillipsburg) Basic Wind Speed(Va,d): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in.OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min.slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation(HVHZ): Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either"5 Nail
Pattem"or"6 Nail Pattern"detailed below.
40' �J7II
Y A/pwt I Ft po
MOmr 2 Notchsh
Fwftms Nad
ore
- - - -
n-ln°
s-
,P
M Fa
?IRS avt• 9•lIC oln• ;
V 1
Figure 12. Heritage®Vintage®
5 Nail Pattern (non-HVHZ only)
4r raw
TT_ �
Ann'" � �
was r1tt
Z"
LJ LJ Ll
r
i
} T71r T.TIr-�-7�R��-T•K
Figure 7113. Heritage®Vintage®
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
i' Asphalt Shingles
TECHNICAL SERVICES. LLC
Hip&Ridge Basic Wind Speed (V,;,,) Max 194 mph
(Frederick&Joplin) Basic Wind Speed (V.,,): Max. 150 mph
Deck(HVHZ): In accordance with FBC requirements,
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction: Min. 15/32 in. plywood existing
construction.
Deck(Non-HVHZ) In accordance with FBC requirements:
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction, Min 7/16 in. OSB existing construction.
Underlayment In accordance with FBC requirements.
Min slope: 2 12 and in accordance with FBC requirements
Installation Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
PStart 5-1/8" exposure
•re—
I II
Start
Figure 1 here 5-1/8" exposure
" Fastener
Fastener
5-5/8" S-51A
Figure 21/4 Figure 3
n
Figure 14. Hip & Ridge (Frederick &Joplin)
TBP15001 A FL18355-R4 Page 9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
`ethnical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation. recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES. LLC
Vintage®Hip&Ridge Basic Wind Speed (V A,) Max. 194 mph
(Phillipsburg) Basic Wind Speed(V�Id) Max. 150 mph
Deck(HVHZ) In accordance with FBC requirements,
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction, Min 15/32 in. plywood existing
construction
Deck(Non-HVHZ) In accordance with FBC requirements,
Solidly sheathed min 15/32 in. plywood or wood plank for
new construction. Min. 7/16 in. OSB existing construction.
Underlayment In accordance with FBC requirements.
Min slope 2 12 and in accordance with FBC requirements.
Installation Installed with 5 inch exposure in accordance with the FBC
and manufacturer's published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind
Direction of prevailing wind
Start 5" exposure
here—
Fn-]
II
<here
Figure 1 5" exposure
" y 2,11Fastener
5-Fastener r'`5.1/2"
Figure 2
g 1/4" Figure 3
Figure 15. Vintage®Hip & Ridge (Phillipsburg)
TBP15001A FI-18355-R4 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61620-3. The manufacturer shall notify CREEK
Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid
This evaluation report does not express nor imply warranty, installation. recommended use. or other product attributes that are not
specifically addressed herein.
r
P CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES. LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B&C with a building mean roof height of 60-ft or less
5) Deck substrates shall be clean, dry, and free from any irregularities and debris All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturers
published application instructions Where discrepancies exist between these sources. the more restrictive
and code compliant detail shall prevail
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 611320-3
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R Priest, P.E. have demonstrated compliance with the Florida Building
Code,6`"Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
'��
�% RY R.
E 2017.09.25
�Q,•..��C• NSF•��$,'�
No 74021 1 1 :31 :41
� STATE OF .QJ —04'001
-
O <v
O? Zachary R. Priest. P E.
�' �S• ' O R 1• � Florida Registration No. 74021
0NA�� � Organization No. ANE11669
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services. LLC does not have. nor will it acquire. a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services.LLC is not owned,operated,or controlled by any company manufacturing or distnbuting products under
this evaluation
Zachary R. Priest. P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have.nor will acquire.a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBP15001.4 FL18355-R4 Page 11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid
This evaluation report does not express nor imply warranty, installation, recommended use. or other product attributes that are not
specifically addressed herein