Loading...
HomeMy WebLinkAboutProduct Approval GET THE MOST OUT OF YOUR - 0 POOL HEATING INVESTMENT! RECEIVE M KY 17 X018 • High performance titanium heat exchanger (Patented ThermoLinlF'i T90, T115and T135 - p ittiltg • Microprocessor controlled defrost cycle allows operation down toimldgfi • Lockable, flip-out control panel protected against sun and weather • Built-in drain pan for condensate management • Impact resistant, rust and fade proof cabinet • Quieter than conventional heat pumps BTUs 80/80/80 51,000 72,000 96,000 112,000 132,000 relati water teumiambien,air' 80/80/63 hu vemidity] 47,000 67,000 90,000 106,000 125,000 80/50/63 30,000 46,000 65,000 74,000 84,000 C.O.P. 80/80/80 5.6 5.4 6.0 5.6 5.7 Coefficient of Performance 80/80/63 5.5 5.3 5.8 5.4 5.6 (water temp/ambient air/ relative humidity) 80/50/63 4.0 4.0 4.2 4.0 4.0 Refrigerant R410A R410A R410A R410A R410A Heat Exchanger Tube in Tube Tube in Tube Thermot-inko Thermol-ine T ermoLink® Electrical kW Input 2.7 3.9 4.7 5.9 6.8 Voltage/Hz/Phase 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 2 8-230/60/1 Min.Circuit Ampacity 19.1 26.8 40.2 38.2 43.3 Max.Fuse Size 30 45 60 60 60 Water Flow Min./Max.(gpm) 20/45 20/45 30/70 30/70 30/70 A Heater Bypass Kit is required when flow rates exceed the maximum Physical Weight(Ibs) 180 200 255 259 287 Length x Width x Height(in) 34"x 34"x 28" 34"x 34"x 28" 34"x 34"x 39" 34"x 34"x 39" 34"x 34"x 39" Shipping Weight(Ibs) 220 240 305 309 337 Length x Width x Height(in) 38"x 36"x 33" 38"x 36"x 33" 38"x 36"x 43" 8"x 36"x 43' 38"x 36"x 43" Rated in accordance with ARI standard 1160 water temp/ambient air/relativ humidity Specifications subject to change AquaCal" Qpreducing quality heat pumps since 198 AOCAL -MADE IN USA .. - AquaCal AutoPilot, Inc. 2737 24th Street North St. Petersburg, FL 33 Document LTPOO98 rev 1a Page Location: :Ionic > Installatioi> > PlumbML, > Clearances CLEARANCES • Proper air circulation is required for the heat pump to operate efficiently.Avoid placing objects near or on top of the heat pump.This includes shrubbery and lawn furniture.These objects will also hinder maintenance access. • Avoid storing chemical containers near the heat pump.The chemicals can cause equipment damage. Overhead Clearance Overhang wM gutter =RECE1 OVERHEAD 5 feet Ram run-off and 1152 cm] sprinklers should be directed away from heater HeatWave SuperQuiety and Tro iCal*(Top View) BACK 6lnches [15 cm) SIDES SIDES 1 toot 1 fool 130 cm) 130 cm) FRONT 3 feet (9 t cm)