HomeMy WebLinkAboutProduct Approval M1 A N,1 1'DAt1,E MIAMI-DADS COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DMSION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidadLZ2LleconomY
Raynor Garage Doors
1101 East River Road,P.O.Box 448
Dixon,IL 61021
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In
Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined
by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION:Showcase/Masterpiece/TC200 Steel Sectional Garage Doors up to 9'-0"Nide
APPROVAL DOCUMENT:Drawing No.P-3305,titled"Spec. Wind Load Showcase/Masterpiece/
TC200",sheets 1 through 3 of 3,dated 07/31/2007,with last revision B dated 08/29/2008,.prepared by
Raynor Garage Doors,signed and sealed by Richard A.Baumann,P.E.,bearing the Miami-Dade County
Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami-
Dade County Product Control Section.
AIMSILE IMPACT RATING:Large and Small Missile Impact Resistant
LABELING-A permanent label with the manufacturer's name or logo,manufacturing address,model
number,the positive and negative design pressure rating,indicate impact rated if applicable,installation
instruction drawing reference number,approval number(NOA),the applicable test standards,and the
statement reading`Miami-Dade County Product Control Approved'is to be located on the door's side track,
bottom angle, or inner surface of a panel.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal ofNOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#15-0714.09 and consists of this page 1 and evidence pages E-1 and E-2,as well as
approval document mentioned above.
The submitted documentation was reviewed by Helmy A.Makar,P.E.,M.S.
r�jfNOA No.17-1026.12
MIAMI-DA a COUNTY Expiration Date:12/11/2018
Approval Date:12/14/2017
1 Z�141_ J 7 Page 1
Raynor Garage Doors
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. P-3305,titled"Spec. Wind Load Showcase/Masterpiece/TC200",
sheets 1 through 3 of 3, dated 07/31/2007,with last revision B dated 08/29/2008,
prepared by Raynor Garage Doors, signed and sealed by Richard A.Baumann,P.E.
B. TESTS "Submitted under NOA #10-0420.03"
1. Test report on Forced Entry Resistance Test,per FBC 24113.2.1, TAS 202-94 of two
16'x 7' Sectional Garage Doors,prepared by Hurricane Test Laboratory,LLC,Test
Report No. G493-0706-10,dated 08/10/2010, signed&sealed by Vinu Abraham,P.E.
"Submitted under NOA #08-0709.12"
2. Test reports on 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC,TAS 201-94
3) Cyclic Wind Pressure Loading per FBC,TAS 203-94
Along with marked-up drawings and installation diagram of a 9'x Showcase/
Masterpiece/TC200 Sectional Steel Garage Door,prepared by Hurricane Test
Laboratory, LLC, Test Report No. G493-0205-08,dated 03/12/2008, signed and
sealed by V-inu J. Abraham,P.E.
3. Test report on Tensile Test per ASTM E8,of steel sheet, prepared by Certified Testing
Lab.,Test Report No. 0156Q, dated 04/01/08, signed.&sealed by Ramesh Patel,P.E.
4. Test report on Salt Spray per ASTM B 117 of painted G40 galvanized painted steel,
prepared by Wendler Engineering Services,Inc., dated 09/25/2008,signed and sealed
by Richard A_Baumann,P.E.
C. CALCULATIONS "Submitted under NOA #08-0709.12"
1. Jamb attachment verification calculations,prepared by Wendler Engineering Services,
Inc.,dated 05/16/2008, signed and sealed by Richard A.Baumann,RE_
D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources(RER)
E. MATERIAL CERTIFICATIONS
1. Test report on Surface Bening Characteristics,per ASTM E84 of Type IX
EPS,Report No.3147467SAT-001,prepared by Intertek Testing Services,NA,Inc.,
dated 04/10/2008, signed by Chris Bowness,P.E.
2. Test report on Self-Ignition Temperature per ASTM D1929 of Type IX EPS,prepared
by Intertek Testing Services,NA,Test Report No. 3147467SAT-002,dated
05/26/2006, signed by Chris Bowness,P.E.
3. Notice of Acceptance No. 11-0926.07,issued to Dyplast Products LLC.,for their
EPS Block Type Insulation,approved on 11/10/2011,and expiring on 01/11/2017.
my A Makar,P.E.,M.S.
Produ Control Section Supervisor
NOA No.17-1026.12
Expiration Date:12/11/2018
Approval Date:12/14/2017
E-1
Raynor Garage Doors
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
F. STATEMENTS
I. Statement letter of code conformance to the 51'edition(2014)FBC and of no financial
interest issued by Wendler Engineering Services,Inc.,dated 09/09/2015,signed and
sealed by Richard A.Baumann,P.E.
"Submitted under NOA #13-0829.15"
2. Statement letter of code conformance to 2010 FBC,issued by Wendler Engineering
Services,Inc.,dated 0,8/26/2013,signed and sealed by Richard A_Baumann,P.E.
"Submitted under NOA #08-0709.12"
3. Statement letter of no financial interest issued by Wendler Engineering Services,Inc.,
dated 05/19/2008, signed and sealed by Richard A.Baumann,P.E.
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. . None.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami-Dade County Department of Regulatory and Economic Resources(RER).
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. ,Statement letter of code conformance to the 61'edition(2017)FBC issued by Wendler
Engineering Services,Inc.,dated 1012412017, signed and sealed by Richard A.Baumann, P.E.
dp!bmy A.Makar,P.E.,M.S.
Product Control Section Supervisor
NOA No.17-1026.12
Expiration Date: 12/11/2018
Approval Date:12/14/2017