Loading...
HomeMy WebLinkAboutProduct Approval I15I201>;' Florida Building Code Online r OP Sisiness & Professional Regulation SCIS Home log In User Registration Hot Topic Submit Surcharge Stats 8 Facts Publications FBC Staff - SCIS Site Map Emits Search ~OtiCa r 'Product Approval I {" USER:Public User Product Approval Menu>Product or Application Search>Ay_plicalion List>Application Detail FL It FL21414-R3 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer CertainTeed Corporation-Roofing Address/Phone/Email 20 Moores Road Malvern, PA 19355 (610)893-5400 mark.d.harner@saint-gobain.com Authorized Signature Mark Harper mark.d.harner@saint-gobain.com Technical Representative Mark D.Hamer Address/Phone/Email 18 Moores Road Malvern,PA 19355 (610)651-5847 Mark.D.Harner@saint-gobain.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Certification Mark or Listing Certification Agency Miami-Dade BCCO-CER Validated By Robert J.M.Nieminen Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year ASTM D1929 2012 ASTM D2843 2010 ASTM D635 2010 ASTM D638 2003 ASTM G155 2005 TAS 100(A) 1995 Equivalence of Product Standards Certified By https:/tfloridabuilding.org/pr/pr_app_dtl.aspxlparam--wGEVXQwtDgtgHSolOoKvoelJYzjWepAOV4NO2njloStMs6ZdxSpCVQ%3d%3d 1/3 5/15/2018 Florida Building Code Online Product Approval Method Method 1 Option A Date Submitted 03/19/2018 Date Validated 03/19/2018 Date Pending FBC Approval Date Approved 03/22/2018 Summary of Products �FL j Nodal,Number or Name I Description ^� 21414.1 CertainTeed Ridge Vent-12" Polypropylene plastic low profile ridge vent with an integral Unfiltered end plug for installation In asphaltic shingle roof systems. Limits of Use I Certification Agency Certificate l Approved for use in HVHZ:Yes FL21414 R3 C CAC 15-0831.06 CT Ridge Vent 12-in i Approved for use outside HVHZ:Yes Unfiltered (-Qxp 09-23-19)_pdf Impact Resistant: N/A I Quality Assurance Contract Expiration Date 1 Design Pressure: N/A 1 09/23/2019 Other: Refer to NOA for Limits of Use. Installation Instructions FL21414 R3 II 15-0831.06 CT Ridge Vent 12-in Unfiltered fexp-09-23-19)Pcf Verified By: Miami-Dade BCCO-CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 21414.2 CertainTeed Ridge Vent 12"Filtered High density polypropylene low profile attic ridge vent for and CertainTeed Ridge Vent 9" I installation in shingle roof systems. Filtered Limits of Use Certification Agency Certificate j Approved for use in HVHZ:Yes FL21414 R3 C CAC NOA 17021307 CORRECTED RIDGE Approved for use outside HVHZ: Yes VENT 12-IN FILTERED 9-IN FILTERED.pdf Impact Resistant: N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 06/14/2022 I Other:Refer to NOA for Limits of Use. Installation Instructions FL21414 R3 II NOA 17021307 CORRECTED RIDGE VENT I 12-IN FILTERED 9-IN FILTERED.pd ff Verified By: Miami-Dade BCCO-CER Created by Independent Third Party: ' Evaluation Reports Created by Independent Third Party: 21414.3 CertainTeed Static Vent-Aluminum Embossed aluminum static louvered roof ventilation system Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL21414 R3 C CAC NOA 17100316 STATIC VENT- Approved for use outside HVHZ:Yes ALUMINIUM.pdf Impact Resistant: N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 03/13/2023 Other: Refer to NOA for Limits of Use. Installation Instructions I FL21414 R3 II NOA 17100316 STATIC VENT- ` ALUMINIUM.pdf I Verified By: Miami-Dade BCCO-CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.QLrlght 2007-2013 State of Florida.::PrivacyStatement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: ®Z:J c T; M Credit Card Safe https://fioridabuilding.org/pr/pr_app_dtl.aspx?param-wGFVXQwtDglgHSolOoKvoelJYzjWepAOV4NO2njioStMs6ZdxSpCVQ"/o3d%3d 2/3 MIAMI-DADE COUNTY 1 IAM PRODUCT CONTROL SECTION "a 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315=2599 NOTICE OF ACCEPTANCE (NOA) vmw.miamidade.eov/economy CertainTeed Corporation 20 Moores Road Malvern,PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade-County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:CertainTeed Ridge Vent-12"Unfiltered LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 4. The submitted documentation was reviewed by Gaspar J Rodriguez. NOA No.: 15-0831.06 MIAMMADE COUNTY Expiration Date: 09/23/19 LdRAWALTA Approval Date: 06/02/16 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Ventilation Material: Plastic Minimum Slope: 3:12 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Product Product Dimensions Specifications Description CertainTeed Ridge Length. 48" TAS 100(A) Polypropylene plastic low profile ridge vent with an Vent-12" Unfiltered Width: 13.8" integral end plug for installation in asphaltic shingle Height: 1/8" roof systems. MANUFACTURING LOCATION 1. Orrick,MO EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Architectural Testing 65457.01-109-18 TAS 100 07/26/06 D8316.01-801-18 TAS 100(A) 09/16/14 D8316.02-801-18 TAS 100(A)Calibration 12/02/14 Hurricane Engineering&Testing, HETI-09-17400 ASTM D 1929 07/01/09 Inc. HETI-09-T102 ASTM D 638 01/30/09 HETI-02-A001 ASTM G 155 09/13/02 PRI Construction Materials AVIG-010-02-01 ASTM D 635 12/02/14 Technologies ASTM D 1929 12/02/14 ASTM D 2843 12/02/14 AVIG-010-02-02 ASTM G 155 06/09/15 NOA No.: 15-0831.06 rluu�l�o Courinr Expiration Date: 09/23/19 Approval Date: 06/02/16 Page 2 of 4 APPROVED APPLICATION Trade name: CertainTeed Ridge Vent- 12"Unfiltered System Type A: Mechanical attachment of ridge vent over composite shingles. Cutout: Cut a 1 %Z"slot along the apex of the roof by cutting'/,"on each side of the ridge.The slot shall terminate approximately 6"from each take edge. Installation: Center the vent over the slot.Install ridge vent using corrosion resistant roofing nails of 0.120"shaft diameter x 0.320"head diameter x 3" long and of sufficient length to penetrate through the wood sheathing a minimum'/16".Place the nails in each preformed nail boss,two at each end, 15" from each end,and the center of each vent section. Install pre-manufactured or field cut ridge shingles over the ridge vent in compliance with the shingle manufacturer's current approved Notice of Acceptance,and the shingle and ridge vent's installation instructions.Nails shall be of sufficient length to penetrate through the sheathing a minimum'/16". Ventilation Calculations: Refer to manufacturer's published literature Minimum Slope: 3:12 LIMITATIONS: 1. Refer to applicable building codes for required ventilation. 2. CertainTeed Ridge Vent shall not be installed on roof mean heights greater than 33 feet. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 4. All plastic ridge vent manufacturers shall have an unannounced follow-up quality control program from an approved listing agency.Follow-up test results shall be made available to the Miami-Dade Product Control Office upon request. 5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo,city and state of manufacturing facility,and following statement: "Miami-Dade County Product Control Approved"or the Miami-Dade County Product Control Seal as shown below. JAPPRMIAMFQADE COUNTY • MIAMFDADE COUNTY NOA No.: 15-0831.06 ••a l p Expiration Date: 09/23/19 Approval Date: 06/02/16 Page 3 of 4 DETAIL DRAWINGS CERTAINTEED RIDGE VENT- 12" UNFILTERED 11.0 K4.4 (k 25 -- 4.G 6.4 13.8 - I 48..0 END OF THIS ACCEPTANCE NOA No.: I5-0831.06 �ED�►DeCOUH Expiration Date: 09/23/19 • • Approval Date: 06/02/16 Page 4 of 4