HomeMy WebLinkAboutProduct Approval (2) 511512018 ' Florida Building Code Online
MZCL
Business &
Professional 1 ! t r�
SaS Home ^Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff SCIS Site Map Unks Search
bo
Product Approval r k
091
USER:Public User
Product Approval Menu>Product or Application Search>A�ylication list>Application Detail
,urs s
NN '-
' ` FL# FL5444-1113
. 3s. - Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer CertainTeed Corporation-Roofing
Address/Phone/Email 20 Moores Road
Malvern,PA 19355
(610)893-5400
mark.d.harner@saint-gobain.com
Authorized Signature Mark Harper
mark.d.hamer@saint-gobain.com
Technical Representative Mark D. Hamer
Address/Phone/Email 18 Moores Road
Malvern,PA 19355
(610)651-5847
Mark.D.Hamer@saint-gobain.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 03/09/2020
Validated By John W. Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL5444 R13 COI 2018 01 COI NIEMINEN.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2016
ASTM D3462 2010
ASTM D7158 2011
Equivalence of Product Standards
Certified By
Sections from the Code
https://floridabuilding.org/pr/pr_app_oti.aspx?param=wGEVXQwtDgtahl g07CSsoycOrl28CcpCHZie8gwTPdZ3U0%2fWg2NQoQl/o3d%3d 1/2
5/15/2018 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 01/24/2018
Date Validated 01/29/2018
Date Pending FBC Approval 01/30/2018
Date Approved 04/10/2018
Summa of Products
�--rte---
FL# Nodel,Number or Name Description
544 1 CertainTeed Asphalt Roof Shingles t 3-tab,4-tab,strip(no-cut-outs),laminated and architectural
1 asphalt roof shingles
Limits of Use Installation Instructions
Approved for use in HVHZ: No (5444 R13 II 2018 01 FINAL ER CERTAINTEED ASPHALT
Approved for use outside HVHZ: Yes I SHINGLES FL5444-R13.pdf
Impact Resistant: N/A Verified By: Robert Nieminen, PE PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use Evaluation Reports
FL5444 R13 AE 2018 01 FINAL ER CERTAINTEED ASPHALT
SHINGLES FL5444-1113.12df
Created by Independent Third Party:Yes
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.jQgQyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.'Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please click here_.
Product Approval Accepts:
W] R-91 ��®
Crt=rii!Card
Safe
https://flo6dabuilding.org/pr/pr_app_dtl.aspx?pararn=wGFVXQvADgtahlg07CSsoycOrl28CcpCHZie8gwTPdZ3U0%2fWg2NQoQ%3d%3d 2/2
NEMO I etc.
Certificate of Authorization#32455
353 Christian Street, Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION REPORT
CertainTeed Corporation Evaluation Report 3532.09.05-R14
20 Moores Road FL5444-R13
Malvern,PA 19355 Date of Issuance:09/22/2005
(610)651-5847 Revision 14:01/24/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein.
DESCRIPnON: CertainTeed Asphalt Roof Shingles.
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein
and FBC 1507.2.7.1/R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMOJetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 13.
Prepared by:
�� --`Q.zio-471'!5 %•
Robert J.M.Nieminen,P.E. ,Or
Florida Registration No.59166,Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert
,,,Sgrvv�`g•�* Nieminen,P.E.on 01/24/2018.This does not serve as an
�•••��.�"``•• electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEW Ietc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEW I etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEW I etc. nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
NNEMOJetc.
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: CertainTeed Asphalt Roof Shingles, as produced by CertainTeed Corporation, have
demonstrated compliance with the following sections of the 6`h Edition (2017) Florida Building Code and 6`h Edition
(2017) Florida Building Code, Residential Volume through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
Entity Examination Reference Date
UL(TST 1740) ASTM D3161 94NK9632 05/15/1998
UL(TST 1740) ASTM D3161 99NK26SO6 11/23/1999
UI(T5T1740) ASTM D3161 03CA12702 05/27/2003
UL(TST 1740) ASTM D3161 03CA12702 06/16/2003
UL(TST 1740) ASTM D3161 03NK29847 10/03/2003
UL(TST 1740) ASTM D3161 04CA11329 05/24/2004
UL(TST 1740) ASTM D3161 04CA32986 12/03/2004
UL(TST 1740) ASTM D3161 05NK07049 04/15/2005
UL(TST 1740) ASTM D3161 05NK16778 05/12/2005
UL(TST 1740) ASTM D3161 05CA16778 05/12/2005
UL(TST 1740) ASTM D3161 05NK14836 05/22/2005
UL(TST 1740) ASTM D3161 05NK22800 06/22/2005
UL(TST 1740) ASTM D3462 R684 09/21/2005
UL(TST 1740) ASTM D7158 05NK08037 06/28/2006
UL(TST 1740) ASTM D3161&D3462 09CA28873 07/23/2009
UL(TST 1740) ASTM D3462 10CA41303 10/07/2010
UL(TST 1740) ASTM D3161 10CA41303 10/08/2010
UL(TST 1740) ASTM D7158 10CA41303 10/27/2010
UL(TST 1740) ASTM D3161&D3462 10CA44960 11/11/2010
ULLLC(TST 9628) ASTM D3161,D3462&D7158 13CA32897 11/21/2013
UL LLC(TST 9628) ASTM D3161,D3462 TFWZ.R684 04/22/2014
UL LLC(TST 9628) ASTM D7158 TGAH.R684 04/22/2014
ULLLC(TST 9628) ASTM D3161&D3462 4786334434 09/16/2014
ULLLC(TST 9628) ASTM D3161&D3462 4786570826 02/12/2015
UL LLC(TST 9628) ASTM D3161,D3462&D7158 4786570717 12/16/2015
ULLLC(TST 9628) ASTM D3161&D3462 4787195678 02/09/2016
ULLLC(TST 9628) ASTM D3161,D3462&D71SB 4787380356 10/26/2016
ULLLC(TST 9628) ASTM D3462 4787380357 10/13/2016
ULLLC(TST 9628) ASTM D7158 4787380357 11/08/2016
ULLLC(TST 9628) ASTM D3161 4787380357 11/09/2016
ULLLC(TST 9628) ASTM D3161,D3462&D7158 4787586427 01/25/2017
ULLLC(TST 962 8) ASTM D3161&D3462 4788042412 11/15/2017
UL LLC(QUA 9625) Quality Control Service Confirmation Exp.03/09/2020
NEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certificate oJAuthorization#31455 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)6S1-5847 Revision 14:01/24/2018
Page 2 of 13
NNEMO I etc.
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 CT20'",XT'"25,XT'"30 and XT'"30 IR are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Arcadia'", Belmont®, Belmont® IR, Carriage House Shangle°, Grand Manor Shangle", Landmark'"',
Landmark'" IR, Landmark'" Pro, Landmark'" Premium, Landmark" TL, Landmark'" Solaris and
Landmark'"Solaris IR are fiberglass reinforced, laminated asphalt roof shingles.
4.1.3 NorthGate'"is a fiberglass reinforced, laminated,SBS modified bitumen roof shingle.
4.1.4 Presidential Shake", Presidential Shake" IR, Presidential Shake TLU' and Presidential SolariST' are
fiberglass reinforced,architectural asphalt roof shingles.
4.1.5 Hatteras'",Highland Slate'"and Highland Slate'"IR are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.6 Patriot'" is a fiberglass reinforced asphalt roof strip-shingle (with no cut-outs) providing a laminated
appearance through an intermittent shadow line with contrasting blend drops for color definition.
4.2 Hip&Ridge Shingles:
4.2.1 Presidential Accessory, Accessory for Hatteras, Shangle Ridge'", Shadow Ridge'", Cedar Crest'", Cedar
Crest'" IR, NorthGate Ridge and NorthGate Accessory are fiberglass reinforced accessory shingles for hip
and ridge installation.
4.3 Accessory Starter Strips:
4.3.1 SwiftStarts Starter Shingle is a starter strip for asphalt roof shingles. Its overall size of 15-1/4" x 38-3/4"
yields two(2)7-5/8"x 38-3/4"starter pieces per shingle.
4.4 Any of the above listed shingles may be produced in AR(algae resistant)versions.
5. LIMITATIONS:
S.1 This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use within FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.4 Wind Classification:
5.4.1 All shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM
D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for us in all wind zones
UP to Vasd = 150 mph (V,,,t = 194 mph). Refer to Section 6 for installation requirements to meet this wind
rating.
5.4.2 Presidential Accessory, Accessory for Hatteras, Shangle Ridge, Shadow Ridge, Cedar Crest, NorthGate
Ridge and NorthGate Accessory hip & ridge shingles have been evaluated in accordance with ASTM
D3161,Class F. All except NorthGate Ridge and NorthGate Accessory require use of BASF Sonolastic NP 1
adhesive or Henkel PLI Polyurethane Roof & Flashing Sealant, applied as specified in manufacturer's
application instructions, for use in wind zones up to Vasd= 150 mph (V,,,t= 194 mph). Refer to Section 6 for
installation requirements to meet this wind rating.
5.4.3 SwiftStart"Starter Shingle has been evaluated in accordance with ASTM D3161,Class F. Refer to Section 6
for installation requirements to meet this wind rating.
5.4.4 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations.
Contact the shingle manufacturer for data specific to each shingle.
NEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certificate of Authori2ation#32455 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 3 of 13
ONEMOletc.
5.4.4.1 Analysis in accordance with ASTM D7158 indicates the measured uplift resistance(RT)for the CertainTeed
asphalt Roof shingles listed in Section 4.1 through 4.6(except Presidential Salads'")exceeds the calculated
uplift force (FT) at a maximum design wind speed Of V,sd = 150 mph (VaK = 194 mph) for residential
buildings located in Exposure D conditions with no topographical variations (flat terrain) having a mean
roof height less than or equal to 60 feet. The shingles are permissible under Code for installation in these
conditions using the installation procedures detailed in this Evaluation Report and CertainTeed minimum
requirements, subject to minimum codified fastening requirements established within any local
jurisdiction,which shall take precedence.
5.5 All products in the roof assembly shall have quality assurance audits in accordance with FAC Rule 614320-3.
6. INSTALLATION:
6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.1 Underlayment shall be acceptable to CertainTeed Corporation and shall hold current Florida Statewide
Product Approval, or be Locally Approved per Rule 611320-3, per FBC Sections 1507.2.3, 1507.2.4 or
R905.2.3.
6.2 Installation of asphalt shingles shall comply with the CertainTeed Corporation current published
instructions, using minimum four(4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6
and the minimum requirements herein.
6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal,use the"Steep Slope"directions.
6.3 CertainTeed asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the
limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions.
6.4 SWIFTSTART"'STARTER SHINGLE:
Fastening: Use four nails, located as shown below
38-3/4"(984 mm) —
t
1'(25 mm)from edge 1"(25 mm)from edge —�I 7-5/8'
(194 mm)
(76 m
Max 3')
MITI)
1 The inner two fasteners must be placed such that they fall at least 3'(76 mm)from
the end joints of the shingle in the succeeding course.
NEMO ETC,LLC Evaluation Report 3532.09.05-R34
Ceittficate of Authonzation#32455 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2019
Page 4 of 13
NNEM10jetc.
LOW AND STANDARD SLOPE STEEP SLOPE
ENGLISH 12" 12" 12" Use four nails and six spots of asphalt roofing cement*for every full
(305 mm) (305 mm) (305 mm)�j shingle(Figure 11-4).Asphalt roofing cement meeting ASTM D4586
(25 grim) Sealant 1"(25 mm)+ Type Il is suggested.
5 5/e'(145 trim)
5 r/1"PianNorrrrtod 460dlin-
1"
—— ————
METRK 13t/e" 13t/a" -�f 13n1e"(25 grim) Sealant .(25 mm) Apply 1"(25 nm)spots of asphalt roofing cement
——— — —— ——— under each tab corner.
6 118" Figure 11-4:tkw fo r nails mid su spots ofasplxdl wmea,t on skip stopec
'CAUTION:Excessive use of roofing cement can cause shingles
to blister.
Ftgare 113:Qsslbwnaitc�tr�'��+�
6.5.1 Hip&Ridge for CT201,XT""25,XT""30,XTTM'30 IR: Cut Shingles
1 .)I Imo- l�2"(50 mm)
(25 rim)r III I 5 12' (305 mm) Ease
(125 mm) '%\
12" S��S ml
d �> N,\25m
Cap _ Cap _ _ Cap — 305 mm) �� as -
Shingly Shingle shingle 5sle shcfN�
Figure 11-24 GYrt tabs,then trim back to make cap sbingfes �1�0.b m ow r1° ��a pal
(Engbsb drmensioas sboum). l5�12
Figure 11-25:Installation of caps along the bips mid ridges.
6.5.1.1 For ASTM D3161, Class F performance use BASF "Sonolastic® NP11" adhesive or Henkel "PL*
Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements.
6.6 ARCADIA
LOW AND STANDARD SLOPE STEEP SLOPE
Use SIX nail.for even full shingle located as shown belowv. Use SIX nails and FOUR 3p)ts of asphalt rooling cement for e%en hill
shingle as shown belie.Appll asphalt roofing cement 1"(25 mm)
from edge of shingle Asphalt roofing cement nxrUng ASTN D 451tb
TITx 11 is suwg steel.
�t'f25 rWR1 1't25 am1—�.
Nva Lire
Nal LineIr LL +t't75 nm) t'�ram1� I�
Lt]
Figure 2:Ise sir uailc for erred'f ilf sbingle.
Figure 3:l sc six nails and four s/rots of a3pbdt
mofrng cement on steel,.lopes.
NEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certificate o/Authorization#31455 Gtr{EDITION(2017)FBC NON-HVHZ EVALUATION F1.5444-1113
CertainTeed Asphaft Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 5 of 13
NNEMOletc.
6.6.1 Hip&Ridge for Arcadia': Cedar Crest'",Cedar CrestTM IR
Use two (2), minimum 1%-inch long fasteners per shingle. For the starter shingle, place fastener 1-inch
from each side edge and about 2-inch up from the starter shingle's exposed butt edge,ensuring minimum
Y.-inch embedment into the deck,or full penetration through the deck. For each full Cedar Crest shingle,
place fasteners 8-5/8-inch up from its exposed butt edge and 1-inch from each side edge.
For ASTM D3161,Class F performance use BASF"Sonolastic®NP1 "adhesive or Henkel"PLO
Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements,to hand-seal
Cedar Crest shingles. Apply NP 1 or PL adhesive from the middle of the shingle's raised overlay on the
top piece and extending approximately 4-inch along the sides of the headlap along a line%to 1-inch from
each side of the shingle's headlap. Immediately align and apply the overlying shingle,gently pressing tab
sides into the adhesive,and install nails. To secure the other side,apply a 1-inch diameter spot of NP 1 or
PL adhesive between the shingle layers.
Hand-sealing adhesive
t/4" 14-
a2" -- �
B' 305 mm)
3 0M) { � \ —
f CjSmK 3/4" I+—
\ Dab of asphalt
cement between
shingle layers V,
6.7 BELMONV4 OR •
Low and Standard Slope Steep Slope(greater than 21:12):
(2:12 to 21:12): Use SEVEN nails and EIGHT spots of
Use FIVE nails for every full Belmont shingle, asphalt roofing cement"for every full
located as shown below. Belmont shingle.Apply asphalt roofing
cement 1"(25mm)from edge of shingle.
See below-Asphalt roofing cement meeting
ASTM D4586 Type 11 is n suggested_
S'd'i 16 an; 8 1 1.`!'t33 rrrr_-i
i22rS r1:
i f
o Add,.l ma,rods,'7gr re.i. 1—' �" t25 nm! I'(25 ivr• -�
S6':16'mr) 6516'
r 2nren'
t
NEMO ETC,LLC Evaluation Report 3532.09.05-R34
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page k of 13
NMEMO I etc.
6.7.1 Hip&Ridge for Belmont®or BelmontO IR:
6.7.1.1 Option 1: For Belmont',refer to instructions herein for Cedar Crest"or Cedar Crest'"IR hip and ridge
shingles. For Belmont®IR, refer to instructions herein for Cedar Crest"IR hip and ridge shingles.
6.7.1.2 Option 2: For Belmont®: Shangle®Ridge
t
?• Exoosure Remove tape
from the right side
\ g and fasten
SECOND
rasten the "
Remove
left �;r . RIGHT
This Tape FIRST
ST
Figure 17-19.'Installation of SbangleO Ridge sbingles
Figure 17-18.•Sbangk-Ridge. on bips and ridges.
6.7.1.3 For ASTM D3161,Class F performance use BASF"Sonolastic®NPl—"adhesive or Henkel "PLQ
Polyurethane Roof&Flashing Sealant",in accordance with Certain-Feed requirements.
6.8 CARRIAGE HOUSE SHANG1.00 AND GRAND MANOR SHANGLE'r:
LOW AND STEEP SLOPE
STANDARD SLOPE fse seven nails and ihrve dots of asphalt noting cement for even
I se Ore nails for every full Shangle. full Grand Manor Shaaglc.Use line nail.and thrve slxNs of asphalt
nwling cemem hn•every full l:arnage Hoot,Shangle and(emennial
Slaic..4pplr asphah roofing cemem 1-(25 mm)from edge of Jungle
(Figure 174).Asphalt roofing control mce ing ALUM D-6M 71pe If
LS sllggesl(d.
mm1
(— —{ 1,n„
518, 85M" 136 rem)
(16mm) (220mn) �• o,kas
Figure 17•n:l se f iv nails fore eVy fidl Gnind l ianor Shangle. 5
Crnriage/louse Sbangle.ar Ceulenuial.l'kne. (16mm� (220 mm
r r- I j — L
----
2
Q5mn)' Rooting Cement
Figure 17-5---Who+insialling Urmul.Ikmor Shangfes on sleep slnptr.
uw seren nails and lbiv spins ol'as*1l nxting a nand.
6.8.1 Hip&Ridge for Carriage House Shangle'and Grand Manor Shangle:Refer to instructions herein for
Shangle'Ridge hip and ridge shingles
NEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization#32455 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2C18
Page 7 of 13
NMEMO I etc.
16.9 LANDMARK", LANDMARK" IR, LANDMARKT11 PRO, LANDMARK'" PREMIum, LANDMARK T" TL, LANDMARK'" SOLARIS,
LANDMARK`SOLARIS IR,NORTHGATE:
LOW AND STANDARD SLOPE LANDMARK TL
131/2" 13" 13'12"
METRIC DIMENSIONS --(343 mm)-++(330 mm) --(343 mm)-- l
12" 143/4' 12' I+I"(25 mm) 1"(25 mm)—�(
1--(305 mm) -(375 mm)----(305 mm)--]
172-
L I--1"(25mm) Release Tape i"(25 mm)�I
NailableJ
Area Figure/3-1:l se foto•oath for crrh fall sNgf.
NorthGate:
Aix
r+49NG t2 IL 3W Y
^ If (305 wit ;375 mmi —1 tar.^7% +I
Kairg�r"b
Lope,nal 1 w ( t =
/I mww,11;14 Ire
{
777 7,11 t---I
Nailing areas for low and standard sbpas If-on 2:12 to 21:12)
Nal tetseen uppw R/caw Fas as shown above.
STEEP SLOPE
Use six nails and four spots of asphalt roofing cement for every full LANDMARK TL
laminated shingle.Sce below.Asphalt roofing cement should meet
A%7M D4596 T)pe 11. ipply 1"spas of asphalt roofing cement unde 131/2" 13" 1311/2,L--
each corner and at about 12"to 13"in horn each edge. (343 mm) (330 mm) (343 mm)
METRIC DIMENSIONS I 6--1"(25 MM) HV(25
I(305 nm) (375 mm) (305 mm) (25mm) ---- (25mm)
Rooling Ceme
�- l'i25 nxn) Relea+Tape 1"(25 mm)
Nail Area
Por Steep Figure 13-5:Use six nails and four spots of
1" aspbalt roofing cement on steep slopes
(25 mm) (25 team;
Roofing Cement
NEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certificate olAuthorization#32455 6T"EDITION(2017)F13C NON-HVH2 EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 8 of 13
NNEMOjetc.
NorthGate:
STEEP 12' 14-ai4" 12"
SLOPE 1----{305 mmy--- —(375 mrrrr--1—(305 mml-I
NAILING
AREA I Nailing L`mds
�. t1"25 mm betwee .JO2ver 1" 25 mm,—
{ (
i
Roofing Cernwt
Nailing areas for sWp dopes(greater than 21,12)
and"Storon-Nailing"
Nail between lower 2 rail lines as snixvn above.
6.9.1 Hip&Ridge for Landmark TM Landmark'"IR Landmark'Pro Landmark'"Premium Landmark'"TL
Landmark'"Solaris,Landmark'"Solaris IR NorthGate:
6.9.1.1 Option 1: Shadow Ridge TI or NothGate Accessory
12' 97A r
(306nm) (250mm)
415/1G415/1C
050mta) (150M ) I (125mm) I (125mm}
Notch for Notch for
Centering i Centering
12 � � —_I 131/4' � i --T
(305mm) (337mm)
Notches for Alignment to Notches for Alignment to
the Top Edge of the Previous 18m the Top Edge of the Previous 75/8
Cap for�r125rtwn)Exposure I Capfur55/8(141mm)Expusure {19fimm}
L L 1
English Dimension Metric Dimension
Shadow Ridge' Shadow Ridge'"
9 27rr
(2S0 mr:
5F1 6-;lzrrer}
13118"
t .0 -(333 mm)--r
C-cruir Ncich 6518'
- (6 6578' ►
_ (168 mm)
m)� 168 mm)
13114' 1 1
(337 tro) ` p 111954 I 1 Centering
rKtfdres tc top 7 5f1r 131/4'gn
Notch
edge of (194 r»m) (337 i) 41 A
prt V K CD1.rsi 'Align these 7 5/8"
notches to top (194 mm)
edge of
T previous course.
NorthGate Ridge NorthGate Accessory
NEN10 ETC,LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization#32455 6"'EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 9 of 13
ONEMOjetc.
Laying Notch
E(1>�nl)
I I
I I
I
lC
Figure 13-20:Use 14)mg notches to center shingles on bips and
ridges,mut to locate the correct exposure.
6.9.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic• NP1TM" adhesive or Henkel "PLO
Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements.
6.9.1.3 Option 2: Refer to instructions herein for Cedar Crest',Cedar Crest'IR hip and ridge shingles.
e PRESIDENTIAL SHAKE'",PRESIDENTIAL SHAKE—I R,PRESIDENTIAL SHAKE TL T1,PRESIDENTIAL SOLARIS":
Militia
LOW AND STANDARD SLOPE: STEEP SLOPE:
For low and standard slopes,use nye nails for each full Presidential For step slopes,use nine nails for each full Presidential shingle and
shingle as shown below. apply i'diameter spots of asphalt roofing cement under each shingle tab.
After applying 5 nails in between the nailing guide lines,apply 4 nails L'
Nailing 40'-^; above tab cutouts making certain tabs of overlying shingle cover nails
Guide Lines (1016 mm)
5 1/4'
�—
(133 mm) . • • .
141(4" 1
1 112' 38 mm) (362 mm) • • • • _ i
NOTE:Apply nails on painted guideline.
Figure 164.FasteningPreddmrhW and Phesidmlial rL Stoke 1'diameter asphalt roofing cement
sbingles on low and standard slopes
Figure 16-7.•FasFenfngPrasfdentid tmd Pratfdentla!TiZ Sbake
sboigim on steep slopes.
6.10.1 Hip&Ridge for Presidential Shake',Presidential ShakeTM IR Presidential Shake TLTM,Presidential
Solaris":6.10.1.1 Option 1:Presidential Accessory
PRESIDENTIAL ACCESSORY
Presidential accessory shingles can be used for covering hips and
ridges.Apply shingles up to the ridge (expose no more than 7'from
the bottom edge of the"tooth."Fasten each accessory with two fas-
teners.The fasteners must be 13/4'long or longer,so they penetrate
either 3/4' into the deck or completely through the deck.Presidential
accessory comes in two different sizes:Accessory produced in
Birmingham,AL is 12'x 12%Portland,OR produces 97/8'x 131/4'
accessory.
6.10.1.2 For ASTM D3161, Class F performance use BASF "Sonolastics NP1` adhesive or Henkel "PLO
Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements.
NEMO ETC,LLC Evaluation Report 3532.09.05-R34
Certificate of Authorization#324SS 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphak Roof Shingles;(610)651-5847 Revision 14:01/24/2018
Page 10 of 13
ONEMO etc.
6.10.1.3 Option 2:Refer to instructions herein for Cedar Crest'",Cedar Crest'IR hip and ridge shingles.
6.11 HATrERAS":
LOW,STANDARD AND STEEP SLOPE: y.""-"
(230 rm) ;7y7 mm) (230 mm) (230 mm)
I (230 mm) f.230 mm) (230 mm) (230 frm) I lit c
25mm)��
L
(25 mm) mm)= 9 3/A"
_ _�_ _I I ('r40lm�r.)
249 318"0mm) ` "-� -- 1.1'e,Cement, - �—
_I F{Qum li,.kNeu"rp/kuferas.cbiuQin w�.W,r.lh Jx+
t FUr SIICh hw nm6 met 1'1,,W qxx,of asfd;all radmq
Figlae 15'.3:Fusleniug 1/a11ems,Cbiug4,ou csm(ml for each lull II.mlcim%hin;)e as shlmn alwn.:yydc I'
low undMaNdard.4opes (?5mm)dimuclet mous of roofing cement l.WM o ii861)pc II
For Ww amt sundanl,lopes,use lire(nils for each full sugg l"l)under Bach tab corner Precc shiugb•rout phcri d.um
IWi ms shingle us>Ixmil alwce, mpnse ce.uml
CAtfrION:Ton much Iwlmg central rm cause shut-d"In hliskm
6.11.1 Hip&Ridge for Hatteras"":
6.11.1.1 Option 1: Accessory for Hatteras
Fasten beth sides
1
vlki
1
I
1
1 2 3
Figure 1544:18 tbrw puce uW0 stparalle to make
54 Hatteras Axessory sbfng(el&
6.11.1.2 Option 2: Cut Hatteras Shingles
9„ �
(230 mm)
I I
I I
Fad
8^ 18,1(46
0
—— ———— LS�
3 m460mm)
Cag Caa Cap Shingle Shirgle Shingle 9 m\
Figure 15-20.Cut Hatteras sbingfm to make corner cap. Figure 15-21:Installation of caps along baps and ridges.
6.11.1.3 For ASTM D3161,Class F performance use BASF "Sonolastic® NP31”"adhesive or Henkel "PLO Polyurethane
Roof&Flashing Sealant",in accordance with CertainTeed requirements.
NEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certykate of Authorization#32455 6'EDITION(2017)FBC NON-HVH2 EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)6S1-5847 Revision 14:01/24/2018
Page 11 of 13
NEMO j etc.
6.12 HIGHLAND q SLATE"IR:
LOW AND STANDARD SLOPE STEEP SLOPE:
Use FIVE nails and EIGHT spots of asphalt roofing cement'for each
rx i 12M i viii frill Highland Slate shingle.For Miami-Dade,S01 nails are required.
Apply V diameter spots of asphalt roofing cement under each lab
r r cornet Asphalt roofing cement meeting ASTM D4586 Type If is suggested.
V5 11�
r—
v�emm)
ps:q :7s',m+I
PA+ -Datlerequm
SIX wstt*nails 'Rs�) _•— --
nAo:Am alae+� Mem�Dece roq�rea t'�i5 mr.) r4
0-14
slx,xsireone�s = it
i galbG cnrrr cwtle,
Ai ea pant Rooting cmxrd—L--
n+!!-i 1,:wFliFnailsjnrrrr�-IhgblmldSkdesbtng.�r.
Figure I-jA.•Use WE rails and e#I spots of aspba'l
rooJing cmnelt under nwh lab i wrner
•CAtrrM:Ecce.%Iveuse of roofing cement can cause shingles
to blister.
6.12.1 Hip&Ridge for Highland Slate",Highland Slate'"IR:Refer to instructions herein for Cedar Crest',Cedar
Crest—IR or Shangle Ridge'"hip and ridge shingles.
6.13 PATRIOT":
LOW AND STANDARD SLOPE STEEP SLOPE
Cse FOUR nails for cwty full shingle k)atled:vc sho%vo below l-sc FOUR nails and four spas of asphalt roofing cement for cern lull
shingle as shorn below:Acph:dl roof m cemen(muting ASTM 1Nitg(l
TY7x 11 is suM-sled.Apply I"I 2i mm)spots of aspisdl roofing
cancut as shown.
_ 1_ CAUTION.E%cessive use ,I looting aver#can clusc shingka to bfister.
—
la-I
�t.� 1 i
,�—�� -jf , -{ 1 ------------
t3'.�"icnm rl t3i'_ary i'..�q'Ti ��i—.
1155A.+
Roolinq centem
Jr- i-tc.
6.13.1 Hip & Ridge for Patriot'-: Refer to instructions herein for Cedar Crest', Cedar Crest'- IR, Shadow Ridge',
NorthGate or Shangle Ridge'hip and ridge shingles.
7. LABELING:
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1/R905.2.6.1.
MEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certificate of Authorization#31455 6'EDITION(2017)FBC NON-HVHZ EVALUATION F15444-R13
CertatnTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:02/24/2018
Page 12 of 13
NNEMOjetc.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this
product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA962S;(414)248-6409;karen.buchmann@us.ul.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 3532.09.05-R14
Certificate oJAuthorization#32455 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R13
CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 14:01/24/2018