Loading...
HomeMy WebLinkAboutWind Load Calculation SHUTTER CORPORATION 12980 SE SUZANNE DRIVE. HOBE SOUND, FL 33455 PH: (772)-545-3300 FAX: (772)-545-3297 Property Information Building Information Owner: Dean Ruscoe Wind Zone: 160 MPH. Address: 1717 Primrose Ct Exposure Category: B Port St.Lucie,FL 35952 Minimum Building Dimension: 50 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations ]F-Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 44 39 7 27.3 -29.6 2 Int 83 63 7 25.3 -27.6 3 Int 83 75 7 25.0 -27.3 4 Int 63 72 7 25.5 -27.9 5 Int 34 72 7 26.7 -29.0 6 Int 34 72 7 26.7 -29.0 7 End 34 48 7 27.4 -36.5 8 Int 34 60 7 27.0 -29.3 _ 9 Int 40 86 7 26.0 -28.4 10 Int 34 72 7 26.7 -29.0 11 End 34 72 7 26.7 -35.1 12 End 34 72 7 26.7 -35.1 13 Int 44 72 7 26.2 -28.5 14 Int 60 63 7 25.9 -28.2 15 Int 44 72 7 26.2 -28.5 Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1