Loading...
HomeMy WebLinkAboutProduct Approval 5/9/2018 Florida Building Code Online s: rL1iis si_.;,; ,4.11 ,rr i°A0fI Q i r {(a;9_F ;r v� n4 y � .@ , R ro ` fiv;"). 1 �1 F r + BCIS Home 1 Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts 1 Publications I FBC Staff I BCIS Site Map 1 Links I Search dFlorida , �Product Approval �( 1 ` K. USFR:Public User product Approval Menu>Product or Application Search>aaplication List>Application Detail I ^_,-isfP•11-4-.1.-ii 1 FL# FL16660-R7 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Haas Door Company Address/Phone/Email 320 Sycamore St. Wauseon,OH 43567 (419)337-9900 Ext 243 mschweitzer@haasdoor.com Authorized Signature Mark Schweitzer mschweitzer@haasdoor.com Technical Representative Address/Phone/Email Quality Assurance Representative FILE COPY Address/Phone/Email Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the John E.Scates Evaluation Report Florida License PE-51737 Quality Assurance Entity Architectural Testing,Inc.,an Intertek company Quality Assurance Contract Expiration Date 12/31/2020 Validated By Kurt Dietrich PE 7 Validation Checklist-Hardcopy Received Certificate of Independence FL16660 R7 COI Cert of Ind Scates2017 s.p_clf Referenced Standard and Year(of Standard) Standard Iggir ANSI/DASMA 108 2012 ANSI/DASMA 115 2012 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pdpr_app_dtl.aspx?param=wGEVXQwtDgsHepng4%2f56e4gonT4z%2fE8EU0%n2b0yJAYy0%2bgPsmDhg0gpg%3d%3d 1/5 519/2018 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted • 10/06/2017 Date Validated 10/18/2017 Date Pending FBC Approval 10/18/2017 Date Approved 12/12/2017 Date Revised 04/16/2018 Summary of Products Go to Page � Page1/34 ' FL# Model,Number or Name • Description 16660.1 01. HT 5000 Series HT Series sectional Aluminum sandwich type garage door 9'2" wide Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoa. Install Supplement rC FL s.pdf Approved for use outside HVHZ:Yes FL16660 R7 II WL-5000-0110-08-40-45-rF s.pdf Impact Resistant:Yes Verified By: John E.Scates 51737 Design Pressure: +40.0/-45.0 Created by Independent Third Party:Yes Other: Evaluation Reports FL16660 R7 AE EvalRep r s pdf Created by Independent Third Party: Yes 16660.2 02.HT 5000 Series HT Series sectional Aluminum sandwich type garage door 16'2" wide Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install Supplement rC FL s.df Approved for use outside HVHZ:Yes FL16660 R7 II WL-5000-0194-08-31-35-rF s.pdf Impact Resistant:Yes Verified By: John E.Scates 51737 Design Pressure: +31.3/-34.9 Created by Independent Third Party: Yes Other: Evaluation Reports FL16660 R7 AE EvalRept r7s.pdf Created by Independent Third Party: Yes 16660.3 03.HT 5000 Series HT Series sectional Aluminum sandwich type garage door 187" wide 1. Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install Supplement rC FL s.pdf • Approved for use outside HVHZ:Yes FL16660 R7 II WL-5000-0218-08-30-34-rE s.pdf Impact Resistant:Yes Verified By: John E.Scates 51737 Design Pressure:+30.0/-33.9 Created by Independent Third Party:Yes Other: Evaluation Reports FL16660 R7 AE EvalRept r7s.pdf Created by Independent Third Party: Yes 16660.4 04. HT 600,700,2000,800,&900 HT Series sectional Steel sandwich type garage door 9'2"wide Series Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install Supplement rC FL s.pdf Approved for use outside HVHZ:Yes FL16660 R7 II WL-0600-0110-08-25-28L-rf s.pdf, - Impact Resistant: No Verified By: John E.Scates 51737 Design Pressure: +24.8/-28.0 Created by Independent Third Party: Yes Other: Glazing is an available option for the 600,700, 2000, Evaluation Reports 800&900 Series product only but it does not meet the impact FL16660 R7 AE EvalRept r7s.pdf resistant requirement for windborne debris regions. Created by Independent Third Party: Yes 16660.5 05. HT 600,700,2000,800,&900 HT Series sectional Steel sandwich type garage door 16'2" Series wide Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install Supplement rC FL s.pdf Approved for use outside HVHZ:Yes FL16660 R7 II WL-0600-0194-08-24-27L-rF s.p4f Impact Resistant: No Verified By: John E.Scates 51737 Design Pressure:+23.9/-26.7 Created by Independent Third Party:Yes Other:Glazing is an available option for the 600,700, 2000& Evaluation Reports 800 Series product only but it does not meet the impact FL16660 R7 AE EvalRept r7s.pdf resistant requirement for windborne debris regions.Glazing is Created by Independent Third Party:Yes not an available option for the 900 Series product. 16660.6 06. HT 600,700,2000,800,&900 HT Series sectional Steel sandwich type garage door 18'2" Series wide Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install Supplement rC FL s.pdf Approved for use outside HVHZ:Yes FL16660 R7 II WL-0600-0218-08-24-27L-rG s.pcff Impact Resistant: No Verified By: John E.Scates 51737 haps://www.Roridabuilding.org/pr/pr app_dd.aspx?param=wGEVXQwtDgsHepng4%2fS6e4gonT4z%2tE8EU0%2b0yJAYy0%2bgPsmDhgogpg%3d%3d 2/5 5/9/2018 Florida Building Code Online Design Pressure: +23.9/-26.7 Created by Independent Third Party:Yes Other:Glazing is an available option for the 600,700,2000& Evaluation Reports 800 Series product only but it does not meet the impact FL16660 R7 AE EvalRept r7s.pdf resistant requirement for windborne debris regions. Glazing is Created by Independent Third Party:Yes not an available option for the 900 Series product. 16660.7 07. HT 600,700,2000,800,&900 HT Series sectional Steel sandwich type garage door 18'2" Series wide Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install Supplement rC FL s.pf .Approved for use outside HVHZ:Yes FL16660 R7 II WL-0600-0218-08-30-34-rE s.pdf Impact Resistant:Yes Verified By: John E.Scates 51737 Design Pressure: +30.0/-33.9 Created by Independent Third Party:Yes Other: Evaluation Reports FL16660 R7 AE EvalRept r7s.pdf Created by Independent Third Party: Yes 16660.8 08. PAN C2011,C2015,C2410, PAN Series sectional pan type garage door 9'2"wide R2410,C2411,C2415,C2460, R2460,C2461, R2461,C2470, R2470,C2471, R2471,C2472, R2472,C2480,R2480,C2481, R2481,C2482,R2482,C2511, R2560,R2561, R2570,R2571, R2572, R2580,R2581,R2582 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install Supplement rC FL s.pdf Approved for use outside HVHZ:Yes FL16660 R7 II WL-2000-0110-25-28L-rF s.pdf Impact Resistant: No Verified By: John E. Scates 51737 Design Pressure: +24.8/-28.0 Created by Independent Third Party: Yes Other: Glazing is an available option for all the Pan Series Evaluation Reports product listed but it does not meet the impact resistant FL16660 R7 AE EvalRept r7s.pdf requirement for windborne debris regions. Created by Independent Third Party:Yes 16660.9 ,09. PAN C2011,C2015, C2410, PAN Series sectional pan type garage door 9'2"wide 'R2410,C2411,C2415,C2460, R2460,C2461, R2461,C2470, R2470,C2471, R2471,C2472, R2472,C2480, R2480,C2481, R2481,C2482, R2482,C2511, -R2560, R2561, R2570,R2571, R2572, R2580,R2581,R2582 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install Supplement rC FL s.pdf Approved for use outside HVHZ:Yes FL16660 R7 II WL-2000-0110-35-39-rE s.pdf Impact Resistant: No Verified By:John E.Scates 51737 Design Pressure: +35.0/-39.0 Created by Independent Third Party: Yes Other: Evaluation Reports FL16660 R7 AE EvalRept r7s.pdf Created by Independent Third Party: Yes 16660.10 10.PAN C2011,C2015,C2410, PAN Series sectional pan type garage door 16'2"wide 122410,C2411,C2415, C2460, R2460,C2461, R2461,C2471, R2471,C2472, R2472,C2480, R2480,C2481, R2481,C2482, R2482,C2511, R2560,R2561, R2571, R2572, R2580,R2581, R2582 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install Supplement rC FL s.pdf Approved for use outside HVHZ:Yes FL16660 R7 II WL-2000-0194-24-27L-rF s.pdfd Impact Resistant: No Verified By: John E.Scates 51737 Design Pressure:+23.9/-26.7 Created by Independent Third Party: Yes Other:Glazing is an available option for all the Pan Series Evaluation Reports product listed but it does not meet the impact resistant FL16660 R7 AE EvalRept r7s.pA requirement for windborne debris regions. Created by Independent Third Party:Yes 16660.11 11. PAN C2011,C2015,C2410, PAN Series sectional pan type garage door 16'2"wide 122410,C2411,C2415,C2460, R2460,C2461,R2461,C2471, R2471,C2472, R2472,C2480, R2480,C2481,R2481,C2482, R2482,C2511, R2560,R2561, R2571,R2572, R2580, R2581, R2582 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install Supplement rC.FL s.qf Approved for use outside HVHZ:Yes FL16660 R7 II WL-2000-0194-31-35-rE s.pdf https://wwwfloridabuilding.org/pr/pr app_dtLaspx?param=wGEVXQwtDgsHepng4%2fS6e4gonT4z%2fE8EU0%2b0yJAYy0%2bgPsmDhg0gpg%3d%3d 3/5 5/9/2018 Florida Building Code Online Impact Resistant:Yes Verified By: John E. Scates 51737 Design Pressure: +31.3/-34.9 Created by Independent Third Party: Yes Other: Evaluation Reports FL16660 R7 AE EvalRept r7s.pdf Created by Independent Third Party: Yes 16660.12 12. PAN C2011,C2015,C2410, PAN Series sectional pan type garage door 18'2"wide R2410,C2411,C2415,C2460, • R2460,C2461, R2461, C2471, R2471,C2472, R2472,C2480, R2480,C2481, R2481,C2482, R2482,C2511, R2560, R2561, R2571,R2572,R2580, R2581, R2582 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install SuRplement rC FL s.ibdf. Approved for use outside HVHZ:Yes FL16660 R7 II WL-2000-0218-24-27L-rG s,pdf Impact Resistant: No Verified By: John E.Scates 51737 Design Pressure: +23.9/-26.7 Created by Independent Third Party: Yes Other:Glazing is an available option for all the Pan Series Evaluation Reports product listed but it does not meet the impact resistant FL16660 R7 AE EvalRept r7s.p f requirement for windborne debris regions. Created by Independent Third Party:Yes 16660.13 13.HT 600,700,2000,800,&900 HT Series sectional Steel sandwich type garage door 9'2"wide Series Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install SuRplement rC FL s.pdf Approved for use outside HVHZ:Yes FL16660 R7 II WL-0600-0110-08-41-46-rD s.pdf Impact Resistant:Yes Verified By: John E.Scates 51737 Design Pressure: +41.1/-46.4 Created by Independent Third Party: Yes Other: Evaluation Reports FL16660 R7 AE EvalRep_t_a_s p4 Created by Independent Third Party: Yes 16660.14 14. HT 600,700,2000,800,&900 HT Series sectional Steel sandwich type garage door 9'2"wide Series Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install SuRplement rC FL s.p_df Approved for use outside HVHZ:Yes FL16660 R7 II WL-0600-0110-08-41-46L-rF s.pdf Impact Resistant:Yes Verified By:John E.Scates 51737 Design Pressure:+41.1/-46.4 Created by Independent Third Party:Yes Other:Glazing is an available option for the 600,700, 2000& Evaluation Reports 800 Series product only.It does meet the impact resistant FL16660 R7 AE EvalRept s pd_f requirement for windborne debris regions.Glazing is not an Created by Independent Third Party: Yes available option for the 900 Series product. 16660.15 15. HT 600,700,2000,800,&900 HT Series sectional Steel sandwich type garage door 16'2" Series wide Limits of Use Installation Instructions 1, Approved for use in HVHZ: No ,FL16660 R7 II WindLoad Install Supplement rC FL s.pf Approved for use outside HVHZ:Yes FL16660 R7 II WL-0600-0194-08-31-35-rD s.pdf Impact Resistant:Yes Verified By: John E.Scates 51737 Design Pressure: +31.3/-34.9 Created by Independent Third Party:Yes Other: Evaluation Reports FL16660 R7 AE EvalRept r7s.gsji Created by Independent Third Party:Yes 16660.16 16. HT 600,700,2000,800,&900 HT Series sectional Steel sandwich type garage door 16'2" Series wide Limits of Use Installation Instructions • Approved for use in HVHZ: No FL16660 R7 II WindLoad Install SuRplement rC FL s,g f Approved for use outside HVHZ:Yes FL16660 R7 II WL-0600-0194-08-31-35L-rF s.pdf Impact Resistant:Yes Verified By:John E.Scates 51737 Design Pressure: +31.3/-34.9 Created by Independent Third Party:Yes Other:Glazing is an available option for the 600,700,2000& Evaluation Reports 800 Series product only.It does meet the impact resistant FL16660 R7 AE EvalRept r7s.�df requirement for windborne debris regions. Glazing is not an Created by Independent Third Party: Yes available option for the 900 Series product. 16660,17 17. PAN C2011,C2015,C2410, PAN Series sectional pan type garage door 9'2"wide R2410,C2411,C2415,C2460, R2460,C2461, R2461,C2471, R2471,C2472, R2472,C2480, 122480,C2481, R2481,C2482, R2482,C2511, R2560,R2561, R2571, R2572,R2580,R2581, R2582 Limits of Use Installation Instructions https://www.floridabuilding.org/pr/pr app_dtlaspx?param=wGEVXQwtDqsHepnq4%2fS6e4gonT4z%2fE8EU0%2bOyJAYy0%2bgPsmDhq0gpg%3d%3d 4/5 5/9/2018 Florida Building Code Online Approved for use in HVHZ: No FL16660 R7 II WindLoad Install Supplement rC FL s.pdf Approved for use outside HVHZ:Yes FL16660 R7 II WL-2000-0110-41-46-rD s.pjf Impact Resistant:Yes Verified By: John E.Scates 51737 Design Pressure: +41.1/-46.4 Created by Independent Third Party:Yes Other: Evaluation Reports FL16660 R7 AE EvalRept r7s.pdf Created by Independent Third Party:Yes 16660.18 18. PAN C2011,C2015, C2410, PAN Series sectional pan type garage door 16'2"wide R2410,C2411,C2415,C2460, R2460,C2461, R2461,C2471, R2471,C2472, R2472,C2480, R2480,C2481, R2481,C2482, R2482,C2511,R2560,R2561, R2571, R2572,R2580, R2581, 112.582 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install Supplement rC FL s,p1f Approved for use outside HVHZ:Yes FL16660 R7 II WL-2000-0194-37-42-rD s.pdf Impact Resistant:Yes Verified By: John E.Scates 51737 Design Pressure: +37.4/-41.7 Created by Independent Third Party: Yes Other: Evaluation Reports FL16660 R7 AE EvalRept r7s.pdf Created by Independent Third Party:Yes 16660.19 19.HT 600,700,2000,800,&900 HT Series sectional Steel sandwich type garage door 9'2"wide Series Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install Supplement rC FL sad' Approved for use outside HVHZ:Yes FL16660 R7 II WL-0600-0110-08-21-24L-rE s.odf Impact Resistant: No Verified By: John E.Scates 51737 Design Pressure: +21.3/-24.1 Created by Independent Third Party:Yes Other: Glazing is an available option for the 600,700, 2000& Evaluation Reports 800 Series product only but it does not meet the impact FL16660 R7 AE EvalRept r7s.pdf resistant requirement for windborne debris regions.Glazing is Created by Independent Third Party: Yes not an available option for the 900 Series product. 16660.20 20. HT 600,700,2000,800,&900 HT Series sectional Steel sandwich type garage door 16'2" Series wide Limits of Use Installation Instructions Approved for use in HVHZ: No FL16660 R7 II WindLoad Install Supplement rC FL s.pdf Approved for use outside HVHZ:Yes FL16660 R7 II WL-0600-0194-08-37-42-rD s,pdf Impact Resistant:Yes Verified By: John E.Scates 51737 Design Pressure: +37.4/-41.7 Created by Independent Third Party: Yes Other: Evaluation Reports FL16660 R7 AE EvalRept r7s,p�if Created by Independent Third Party: Yes Go to PagePage 1/3 4 do ren Next Contact Us::7601 Blair Stone Road,Tallahassee FL 32399 phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click hem. Product Approval Accepts: fru: 2;2, :!jreCFg Credit Card Safe SeCurit'S"MET;ucs• https://www.floridabuilding.org/pr/pr app_dtl.aspeparem=wGEVXQMDgsHepng4%2fS6eslgonT4z%a2fE8EU0%2b0yJAYy0%2bgPsmDhg0gpg%3d%3d 5/5 1 I 2 I 3 I 4 t 5 I 6 I 7 I 8 NOTE: Track configuration above Door WIdth 9'-2"Shown the door opening does not effect F - See chart below for other the wind load rating of the door. F '-p- Top Bracket door widths DETAILA(eheet2af9) Flag Bracket Detail (eheet 2 W 3) 11 I r ti 14i — E D • i �!I E d e / ; v. i Door Height : Bars • ? ' SiiedteLock en(sheen 2 of 3) 8'-0"Shown o , Manual door(locks are) required unless an automatic Jemb BfaCiBt — See for chart , Detail F sheet 2 of 3) 4- Q U operator is installed. �I' below forother s � g8•+/-3" '�i1' door heights g s' .'• �' 1 S ! 1 I N D !! 44 • ow 38"+/-3" D E ED o� .1 lik :. jI _` t . Bottom Bracket.—/ End Hinge Stmt&Strut Attachment Irdennedlata Hage 4"+/-3"J Detail C(sheet 2 of 3) Detail B(sheet 2 of 3) Detail E(aheet2 of 3) Detail D(sheet 2 of 3) 1 "+/-3"- Digitally signed by John E.Scates P.E. Date:2017.09.29)15:56:21-05'00' C This product hos been evaluated per ANSI/DASMA 108-05 (end -12) for static air pressure, Jamb bracket quantities shown are for use with grade 2 or better southern C pine jambs. This product hos been evaluated per ANSI/DASMA 115-05 (and -12) for large missile impact and cyclic \\\\�,6. s'/////// wind pressure. Supporting structural elements are to be designed by a registered professional \\\\ 1�' T� Model Number engineer for specific wind loads. �\ �O,•y16EttlaF•�� � PAN C24Eoa R2460 SERIES Door Total#or Jamb Bride NOTICE: . `::::11:,.....5. — PAN C2410 E.82410 8E10E3 PAN 07401 a R2451 SERIES Height SecNma Total#a Struts Per Skle drawingsarea No.51737 These ' supplement to the installation — PAN C24f08R24e0SERER PAN C24716R7471SERIES 8'-0' 3 9 8 instructions for a standard door =::::: r.0.0.1.:14... . *PAN C241114,R24e1 sERIES PAN C2472&R24728ERIES PAN C2011 SERIES 8'-0' 4 4 9 and only covers those PAN 02482&R2492SER1E9 PAN R2880 SERIES PAN C2015 SERIES 8'-3° 4 4 3 procedures that vary from ,bSTATE*: OF ,PAN R2580 SERIES PAN R2561 SERIES PAN C2411 SERIES 8'-8' 4 4 4 standard door installation. If �O•.•• P, t1` PAN R2581 SERIES PAN R2571 SERIES PAN C2415 SERIES these specific procedures are //A CORt Q\ N • B PAN R2582 SERIES PAN R2572 SERIES PAN C2511 SERIES 8'-g' 4 4 4 not followed, the door may not F4QS (Gly\\\ T-0' 4 4 4 perform as designed. // fONAV B Doer Wbths Design Pressures Center Center Center impact ////f II 1111\\\\ End Stlle I T-3' 4 4 4 Up To + 3. Mite Hinges _ Stiles Ht1 Stiles Hinges1Resistant T-6' 4 4 4 John E Scates, P.E. 8'-2° 39.2 -43.7 Single 3 1 3 1 3 1 NO 2560 King Arthur Blvd. Ste 124-54 9'-2" 35.0 -98.0 Single 3 1 3 1 3 1 YES T-8' 5 5 4 Lewisville, Texas 75056 _ 10'-Y 28.4 -31.7 Single 4 2 3 1 5 2 NO T-9' 4 4 4 IMPACT RESISTANT Florida P.E. # 51737 12'-2' 19.8 -22.1 Single 5 2 5 2 5 2 NO T-9' 5 9 4 8'-2" 35.0 -39.0 Single 3 1 3 1 3 1 YES 8'-0' 4 4 4 Professional Engineer seal provided only for This product is designed and sold by PSF. The AHJ or Engineer of Record is responsible for determining the 8'-0' 5 5 4 FL#16680.23 verification of wind load construction details. PSF required for any given site. Maximum section height is 24 in. r-4111 :., DEICBIPROlt Maximum door height is 16 ft. Y�ri1 I 9'2"PAN2Aool�IDSWMMAD A All doors, even those above the tested height, 9 0 SECTIONAL DOOR 4, DESIGN PRESSURE.3.1.6,39.01.81, A are available with jamb brackets or commercial --F''W'ik"Iltltlii KU w1.2030a310aussde!*11111 I W 3 111A4 D full angle. The moximum spacing of the jamb i� brackets/track clips should be maintained. `�i1Y 4nR KATE Mt 5/30/14 *win se MVS •fy941W I MODEL(8): See Sheet 3 1 I 2 I 3 I 4 } 5 I 6 I 7 I 8 1 I 2 I 3 f 4 1 5 I 8 I 7 I 8 END STILES PUSH NUT 3n - ---- - - 16 Ga Galvanized Steel 7/16" 3n _ END HINGE TEK SCREW �� See DETAIL K for push nut 14 Ga Galvanized Steel �l 1. 1 • �, 1/4" X 3/4" Hex Washer Head F . . PUSH NUT ' placement. Self Drilling (3 per Bottom Bracket) F 110 L�■�, 7/15' ���i TEKSCREW , il SeeDETAIL K for push nut TEK SCREW i/4" X 3/4" Hex Washer Head IrmliIIIIIIIIPIP �_ Self Drilling (6 per Hinge) BOTTOM BRACKET .1l� placement. i 1/4" X 3/4" Hex Washer Head C OI 13 Ga Galvanized Steel ADJUSTABLE TOP FIXTURE I ( 1 Self Drilling (2 per Bracket) IF NOTE: This screw shouldbe located below the repunche12 Gop PUSH NUT pp hole and o throw h the hin e, � i /�r TEK SCREW LOW HEADROOM TOP a g g ul ��_ 7 16" — , �l 1/4' X 3/4" Hex Washer HeadI 1111 BRACKET • end stile and skin edge, i�� See DETAIL K for push nut placement. Self Drilling (4 per Bracket) PUSH NUT7 DETAIL A DETAIL B See6DETAIL K for push nut DETAIL C BOTTOM SEAL E LOW HEADROOM placement. 23^ TOP BRACKET E 4 3 1/4" x 3 1/4" E STRUT OilINTERMEDIATE STILE 18 Ga 70 KSI Minimum 16 Ga Galvanized Steel Galvanized Steel ` Alp � 41P4 I 3111 4 , JAMB BRACKET \� • '� 12 Go Galvanized Steel o•oL7o till_-• SLIDE LOCK or LOCK BARS��Ir�i�— INTERM4DIATE HINGE • 1---t: �n �__ �� norequiredwithoperator)i 18 or Ga Galvanized Steel 3 ' , nie WV =I ' TEK SCREW TEK SCREW 1/4" x 3/4" Hex Washer D ,O. 1/4" X 3/4" Hex Washer Head ,�, '� BOLT & NUT _ pp, g (4 per TEK SCREW ' 1/4-20 X 5/8" Carriage �I Head Self Drillin D Self Drilling (4 per Hinge) 1/4 X 3/4" Hex Washer Bolt & 1/4-20 Hex Washer _I Slide Lock) DETAIL D DETAIL E Head Self Intermediate Stiles) DETAIL F Nut (1 per Jamb Bracket) DETAIL G —�. WITH AND WITHOUT BRACE __Z-` 00 a 0 I �= NOTE: Details on some views omitted for clarity. l0 0 0 0 Double end stiles and end hardware may be 0 o O 0C o �� iC7� lila Ily� required on wider or heavier doors. `\\\,11'i",'//, C a �—= Maximum " \��\0 E• 8C,� �i��� RESIDENTIAL & LIGHT COMMERCIAL COMMERCIAL 1/2^ \\ �0,y�GfiNd�r•.�4 � COMMERCIAL For Standard, High For Standard, High DETAIL K !� FLAG BRACKET •. i _ For Low Headroom & Vertical Lift & Vertical Lifta o0 000•.c' ' :• No.51737 • With 2' Track and With 2" Track and With 3" Track and There should be a space of -•' BOLT Single End Stiles Single End Stiles Single End Stiles maximum 1/2' between the 41 5/16 x 1 5/8" Lag Bolt *1 ALTERNATE BOTTOM BRACKETS roller hub and the outside 01' (4 per Flag Bracket). �•0:,, STATE OF ,�� edge of the roller holder I ip0• r :411 4; NOTE: The bottom bracket tested (shown in DEIHIL,0,) is the lightest bracket available. Which is set by the push 00 BOLT & NUT / •L`�••!c,C�R�t:• % \ B nut. &1/4020 /8 TrackWasheBolt /��//Ss�N111��0�`\ B N'^• DOOR SKIN Min. (2 for Horizontal & 2 for °f 1' Minimal 25 Go Galvanized Pointed Steel of 1' Vertical Track) John E Scates, P.E. M��/ / ������y / 2560 King Arthur Blvd. Ste 124-54 AA :, 4 1 I '.. Lewisville, Texas 75056 � 10 �,� I'ACT RESISTANT Florida P.E. # 51737 Ivor-EA . -----Ar sairai I 2 FL#18860.23 Professional Engineer seal provided only for verification of wind load construction details. BOLT&WASHER ROLLER 1, ��/ VERTICAL TRACK - 2" Nominal WOOD JAMB 5/15'x 1 5/8'Lag Bolt& 2'O.D. l,Sp14.7 INE3CMP IOlb 13 Ga Galvanized Steel tested. The vertical wood jamb 2" Diameter Nominal g 9'YPAN 2000 tilID189 WI1d1IAAD x 7 16'I.D.Flat Washer )NOTE: Jamb bracket must be in 3'Nominal 13 Ca is also fasteners may be counter sunk Eleven BOII N IOn Or DETAIL H 1 . Ige30SEI WALAtliryrrewCE contact with the 2x6 No approved as an alternate. to provide aa flat mounting a (! 0 0 DESIGN PRE¢mma+3tN-3hOPSP A NOTE:IIThelowe)washer is not(required mbsh surfaceto tsh str3 fore jamb tachmhnTen imuBall Steel awibl ,!!'.'=.U;,an,_r gAnp�W�,0110d8.3S.388HU112 Q 3 Et 13 details on sheet 3 for attaching0 Minimum Workable for angle mount. 1 Shaft Length Shown, dsfw• BA'E�5lJfV14 I 1M1Y R: MVS ,Ve iasiii .mh s° 111OEEL(8$ Sec Shed 3 1 I 2 1 3 I 4 I 5 I 6 I 7 I 8