Loading...
HomeMy WebLinkAboutProduct Approval • MIAM1•DADE �, w MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES Alp. Miami,Florida 33175-2474 • BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA} www.miamidade.gov/economy DAB Door Company,Inc. 12195 NW 98th Avenue Hialeah Gardens,FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION:Hurricane Master®Model 824/811 Steel Sectional Garage Door 16'-2"Wide with Window Lite Option (DP+36.0,-44.0 PSF) APPROVAL DOCUMENT:Drawing No.02-21 Rev L,titled"24 GA. Roll Formed Steel Sectional Garage Door",dated 09/10/2002 and last revised on OCT 05,2017, sheets 1 through 5 of 5,prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad,P.E.,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo,manufacturing address,model/series number,the positive and negative design pressure rating, indicate impact rated if applicable, installation instruction drawing reference number,approval number(NOA),the applicable test standards,and the statement reading`Miami-Dade County Product Control Approved' is to be located on the door's side track, bottom angle, or inner surface of a panel. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. • INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#15-0304.01 and consists of this page 1 and evidence pages E-1, E-2 and E-3,as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I.Chanda,P.E. NOA No.17-1018.12 MIAMFDADECOUNTY Expiration Date: July 21,2020 APPROVED _ ''' • Approval Date:December 14,2017 Page 1 DAB Door Company,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitted in previous files A. DRAWINGS 1. Drawing No. 02-21,titled"24 GA.Roll Formed Steel Sectional Garage Door",dated 09/10/2002,with last revision K dated 03/09/2015,sheets 1 through 5 of 5,prepared by Al- Farooq Corporation,signed and sealed by Javad Ahmad, P.E. B. TESTS "Submitted under NOA #11-0414.12" 1. Test Report on Uniform Static Air Pressure Test,Loading and Forced Entry Test per FBC, TAS 202-94, of"DAB 824 Sectional Residential Garage Door"prepared by Hurricane Engineering&Testing Inc.,Report No.HETI-07-4200, dated 05/02/2007, signed and sealed by Candido F.Font,P.E. 2. Test Report on Large Missile Impact Test per FBC,TAS 201-94 and Cyclic Wind Pressure Test per FBC,TAS 203-94,of"DAB 824 Sectional Residential Garage Door",prepared by Hurricane Engineering&Testing Inc.,Report No.HETI-11-3204,dated 01/20/2011, signed and sealed by Candido F.Font,P.E. 3. Test Report on Tensile Test per ASTM E8-08 of"Sectional Residential Door(skin)", prepared by Hurricane Engineering&Testing Inc,Report No.HETI-11-T100,dated 01/21/2011,signed and sealed by Candido F. Font, P.E. "Submitted under NOA #05-0228.02" 4. Test Report on Large Missile Impact Test and Cyclic Wind Pressure Test, of"Sectional Residential Door with Windows",prepared by Hurricane Engineering&Testing Inc.,Report No.HETI 03-1328,dated 07/15/2003,signed and sealed by Rafael E.Droz-Seda,P.E. 5. Test Report on Uniform Static Air Pressure Test,of"Sectional Residential Door"prepared by Hurricane Engineering&Testing Inc.,Report No.HETI 03-1329, dated 07/15/2003, signed and sealed by Rafael E.Droz-Seda,P.E. 6. Test Report on Tensile Test per ASTM E-8 of"Sectional Residential Door(skin)",prepared by Hurricane Engineering&Testing Inc,Report No.HETI 03-T078,dated 10/31/2003, signed and sealed by Rafael E.Droz-Seda, P.E. "Submitted under NOA#03-0210.04" 7. Test report on Salt Spray(Corrosion)Test per ASTM B 117 of a painted G-40 steel panels, prepared by Celotex Corporation,Test Report No.258592,dated 08/17/1998, signed by W.A. Jackson,P.E. C. CALCULATIONS "Submitted under NOA#14-0814.10" 1. Anchor verification calculations prepared by A1-Farooq Corporation,dated 09/22/2014 and 07/24/2014,signed and sealed by Javad Ahmad,P.E. Ishaq I.Chanda,P.E. Product Control Examiner NOA No.17-1018.12 • Expiration Date:July 21,2020 Approval Date:December 14,2017 E-1 DAB Door Company,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS (Cont.) "Submitted under NOA#11-0414.12" 2. Anchor verification calculations prepared by Al-Farooq Corporation,complying with F.B.0 2007, dated 04/07/2011,signed and sealed by Javad Ahmad,P.E. 3. Anchor verification calculations prepared by Al-Farooq Corporation,complying with F.B.0 2007,dated 12/19/2008, signed and sealed by Humayoun Farooq, P.E. "Submitted under NOA #09-0128.02" D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 13-0717.01,issued to SABIC Innovative Plastics,for their Lexan Sheet Products,approved on 11/28/2013 and expiring on 07/17/2018. 2. Notice of Acceptance No. 14-0311.08, issued to Insulfoam,LLC,for their Tnsulfoam Expanded Polystyrene Insulation, approved on 08/14/2014 and expiring on 11/29/2017. 3. Notice of Acceptance No. 11-0926.07,issued to Dyplast Products,LLC,for their Expanded Polystyrene Block Type Insulation,approved on 11/10/2011 and expiring on 01/11/2017. 4. Notice of Acceptance No. 11-0926.06,issued to Dyplast Products,LLC,for their Dyplast ISO-C1 Polyisocyanurate Insulation,approved on 11/10/2011 and expiring on 01/11/2017. 5. Notice of Acceptance No. 10-1129.04,issued to Cellofoam North America Inc,for their Expanded Polystyrene Block Insulation, approved on 02/24/2011 and expiring on 02/24/2016. "Submitted under NOA#05-0228.02" 6. Test Report on Accelerated Weathering Using Xenon Arc Light Apparatus Test per ASTM G155 of"PVC Extrusion Material",prepared by Hurricane Engineering& Testing,Inc.,Report No.HETI 04-A002,dated 09/27/2004, signed and sealed by Rafael E. Droz-Seda,P.E. 7. Test Reports on Tensile Test per ASTM D638 of"PVC Extrusion Material",prepared by Hurricane Engineering&Testing Inc.,Report No.HETI 04-T251,dated 11/29/2004 signed and sealed by I. Ghia,P.E. 8. Test Report on Self-Ignition Temperature Test, Rate of Burn Test and Smoke Density Test of"REHAU non-foam PVC extrusion material",prepared by ETC Laboratories, Report No. 04-761-15019.0, dated 05/06/2004,signed and sealed by J. L.Doldan,P.E. F. STATEMENTS "Submitted under NOA#14-0814.10" 1. Statement letter of code conformance to the 5th edition(2014)FBC and no financial interest; issued by Al-Farooq Corporation, dated 05/13/2014,signed and sealed by Javad Ahmad,P.E. Is �1 LL4,. 4-- Ishaq 1.Chanda,P.E. Product Control Examiner NOA No. 17-1018.12 Expiration Date:July 21,2020 Approval Date:December 14,2017 E-2 DAB Door Company,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUB 2. New Evidence submitted. A. DRAWINGS 1. Drawing No. 02-21 Rev L,titled"24 GA. Roll Formed Steel Sectional Garage Door", dated 09/10/2002 and last revised on OCT 05,2017, sheets 1 through 5 of 5,prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. Note: This revision consist of editorial changes to comply with FBC 2017. B. CALCULATIONS 1. None C. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). D. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0221.06,issued to Insulfoam, LLC, for their Tnsulfoam Expanded Polystyrene Insulation, expiring on 11/29/2022. 2. Notice of Acceptance No. 16-1108.04,issued to Dyplast Products, LLC, for their Dyplast ISO-C1 Polyisocyanurate Insulation, expiring on 01/11/2022. 3. Notice of Acceptance No. 15-1203.04,issued to Cellofoam North America Inc, for their; Expanded Polystyrene Block Insulation, expiring on 02/24/2021. 4. Notice of Acceptance No. 15-0915.08,issued to SABIC Innovative Plastics,for their Lexan Sheet Products,expiring on 07/17/2018. E. STATEMENTS 1. Statement letter of conformance to FBC 2014 (5Th Edition) and FBC 2017 (6th Edition), prepared by Al Farooq Corporation, dated 10/05/17,signed and sealed by Javad Ahmad, P.E. F. OTHER 1. This NOA revises NOA#15-0304.01, expiring 07/21/20. . Ishaq I.Chanda,P.E. Product Control Examiner NOA No. 17-1018.12 Expiration Date: July 21,2020 Approval Date:December 14,2017 E-3 I ova lz-zo\3ovays J ZLZ6-Z90(500)W 4 9102-LSZ(009) I.1 ' i 1 lq'yya, o_ N eesszsz esoE)%V3 oasancL900)19 BIOLC 'I! 'suapm0 yoaloiH 0013109...wan Li axn awls 9111 30Nw0 ON 11'60110 M ( 9003-N',v, c N Is .7 `(asst'Arra) erne VataOV YWmw .any 4126'M'N 96101 ax„a sxl sav,as ex ,teen r c I ozz auns'auual3SNns Docs •au '�Cuodwo goo 1N3wda,3A3a L,naoue N eN33NIoN3 _ _ _ I a ENG =us s.....1 ON silawi� (a-.1-s/1 so.) •oN .- 1.1314 I` e, NO11VuOd8OO bOOHVo-lV (80 30Mlo91900003S 1331S 0306041109 10$N� ( u0gau0s'v as suosnw)I is-01-.0 .n99L ".0 - --- --- 9000 SNou039 N31 r fil(ln 1,,,, 114006 9000.0-.91 y ��" {( //'/ 1300 SWUM INJ -9 — �� a 30l .01„. 3 �p ,��/l�i uaoH a000.o-.e ��^. €$qx o2 sp N€qF$isg 3 9 ..--$47 <o= - — E. >> i,�».. 'Leg •: €tee g 'm -7\ •i'y 111 /1 I ,I, P• i g '8i €2P : m i 1 h ; UiHibo ' 5 - s Vag 33 n \- / \ / ' / VI 111Til 1 c1 0 L9 DI ID Et! DI �9 p / \ / \ / \ �. m m ate) \- / \ / 1 1 " + ® ��,'`� IN Z:2 gE N / • / \ / m ® ®" zo IIiui a A oyL a eF�o NWE,0 / V / -A ✓ A it 1�I i j s - z ____ ... ff_ i€a �a \ /Tr�sfi> . i \ 'II Z.2 o 'g M 6a" 1-1 I 1111.A �— � ri — • oZ� / /- / \ / ,III 1N i�' ® a IWJP -' / .�✓ IISIIIo = � o -' 6o- IIIII 1 1111 G gdW , o 0. o, ® o$ �� ' i / \,-‹ \ ill a E do ISI g ri n_ :....,,,,,ce�4.., € 69+ 118 �, L. '+' 9Z , - _� e6= 0 �l a �1 _ I 4 li1 EEdEl ' : ' a:6,9, s'. LA, ."‘1- - V tAg zlill . $zw, ,a- - 4111111arlit ,r ,WWI%x sag 9b000 MT WEI M.1 u.,., i: fir 6 $� `�i `s;-------.'r� Fk :.^„fi 1rkk�, r:&.::- «F«Nok 1n-1.11: 1.1 %4 ,62 •..E N 11 1111 .11111 i11111 111111 111111 " a as as aaa T"0 r�I"� z '4:1 511.11 ommmm�� m o mW—Wg mmmmmm�12,5.ommrm ^5 .N.,-,n _- �av� • ___ 5555=222,2=o- '«,2,"122="g. =E000=r` • • )- 24 GA STEEL PANEL " trQ RI1� r O RAPS BEM OVER PANEL • Z w � SACoo Lr0 ogey 1/2•PUNCHED HOLES 1D- 04.O.C. 111. '/ 01 0. " ` 01DQ 055•%z-I/H 0 3/1'X z' _ TT�J,' 0��GAT.STEEL U.BM REINFORCING TRUSS O BORON OF PANEL TRUSS FASTENED TOI (ISZVERTICAL INTERMEOMTE SIRES W/TWO9IQ IK N:1g- o/14 X 5/8•SACS.AND TO ENO STILE � }�� pcODDDr �•ZGW/FOUR/14%J/4'SELF DRLLLNC S � °0'�P!FMts NN MAT. 2:O b j 6bR � 1 O 2 0 y I � - •c•4.1 3�.x ]/I6'POP RNETS I - P•s6�a E7o1�i g 1� I AT 4 O.C. .<;............... 4�4� n (v 1 �� (e)FOR%'.' 1'STILES n •^ 5 FOR 18'STIlFS 1.5 co 'ad .02Y STL PANEL -END 5771E �' .n' OU51DE OF D00' C v . It. i 1 g V l v r 1ST SECTION (BOTTOM( INTERMEDIATE SECTION TOP SECTION OPSSTSlYEORULOING CH 13 g SOLID BRASS DOOR R 1 E,-,-.2 o STEEL TRACK BRACKET FASTENEDr ^s TO WOOD 15110 WITH /14 x 5/8'SMS 3/4•x 2•x 2-1/2•X.049•STEEL N 9/16'SECURITYS.HOLES HARDWARE' L. I 5/16•X 1-5/8•LAC SCREW B PER HINGE END STILE,CONNECT TO PANELS WITH INSTALLED IN 9/16•DIA.HOLES IN CENTER STILE (FULLY TXREMED) FLAPS AND(5)OR(6)3/I6•AWN RNETS POSDIONED AT EYE LEVEL HEX WASHER HEAD TYPE A 1/Y x 1-3/4•x.0513•FORMED STEEL SEE DETAIL ABOVE ONE PER BRACKET GLUED TO PANEL AND SECURED TO ANCHORS AT TRACK BRACKET. END SOLE WTTH(4)3/16•POP RNETS •/R'NA POWFR_RRLT R/'POWERS' 'N N N SOUTHERN PINE - • • EDGE a g 1-7/8'%2-5/B•%.049•STEEL ���111 055 S. N°.J/ CENTER SNE,CLUED AND RNELEO X133 DISTANCE I A)2'MIN.BASED IMO CONCRETE(3000 PSI MIN.) e€ C w TO PANEL W/(4)3/16•RIVETS 3/T 6' I 2'MIN.EDGE DISTANCE ,F1 H N /14%5/8•SUS.c POP RNETS 1-3/16 3/R•OV_ t -SI Fcv[BY'M c y g B A a 49m1-��''A'•ilii I� 4/MNGE . I \°�'ti°�',..L. 9)1-1/4•MIN.EMBED INTO CONCRETE OR FILLED BLOCK o 2 N I N IfJiJ klCONCRETE Fc.A.3E00 PSI _g9= ??13x SB 2STEEL TACL _^J ANCOR TYAQ a_ L(E PER BR3 FO 6't.- 1NW—moi SEE SHEEP]FOR BRACKET SPACING // ET II'/,SII �r��x.{11 iprii TMI IIIl-1I E G• :"� li 7-1/4V.x.aso• INTERIOR SIDE T-1/2•x IINCE 1/4-20 55 BOLT 2 •'*_ u STEEL TRACKGAL STEEL ENO ROLLER HINCE k NM - `:.5, CENTER HINGE 14 GA x 2-1/B•X 1•(BTAIONAL 1.62•DIA x.50•STEEL ROLLERS(STD.) (.,. I _ 12 GA.%3-5/16'X 1-1/2'(OPTIONAL 7/13'PUSHNM 1.82'DIA X.50•NYLON ROLLERS(OPTIONAL) +' `'� T O d,G2 n1o. FASTENED TO TRACK PIA INS7A I m ON ROLLER SHAFT 2.75'DLA x.50'STEEL ROLLERS(OPTIONAL) -..9 O'. Eh•. Q'2-2 1 W/1/4-2D%5/8•TRUSS HD. 2.75•DIA X.50'NYLON ROLLERS(OPTIONAL) /s/C...• \\V SLOTTED N.S.8 LOCK NUT SECTION B-B WM1 5•STEM '/////NTA,,\\\ (sheet 2of 5) • i)a I 21'PANEL !i::61 r 11 -� Mia F� • • 11‘ \CI \ ,q a g� \�i Z $00 $o \H9 a 'g -F�pxR BEEE •9e2 FP.-4 . K2 TO MIT g p } - P- } .1 io i :. B.o `'T 141 907, N- :4 -i�a 1p xp J$ -c Le 5 -g„ 6 $qP!1 514igel 1 'i 1g `§io0 x PO s Et'l 4. g z. P 9g r '" o 82 z>.t_L€), id i sl> rBY OPENING HEIGHT - — 0000 HEIGHT o I . FA- N N Re of mol 06 0O: �o 83 a, — 58PP I R2 B7 L J�ii-i1J•�:a�!:�� 1-Eppeirn-- lb o2 m AdY �§ ga . • X- MOIL- -B" >> A N ��00000_ X > >7401 •�N ,w;1;17 N I I 22 tTl ... \ gm I.1 I.I,1.19 L J o c FcN ulru L" y u - ::::: m '=�1a 6�= ; N o 9 0203 -2; a o - O , 8 si -7:-5,Y: ":" 1 :11r i= f fq. - - z> ---1 madlhgLi - - - .a(°�` 09-0--]r(revismnse ) (24 OA ml FINU1E0 STEEL SECTIONAL GARAGE Mr AL-FAROOQ CORPORATION ' g -o d 1 ee dote--�description a (..9• (.eo6- ) I_03.15.10 .4.505 orE - _- - DAB Door Company. Inc. 9300SUNS F PRODUCT DEVELOPMENT - — --- — W 110715 09 0010[906 swat P Y• MIAMI, SUNSEF 33173A 3E. 220 c 12195 N.W.ens, Ave. Ta,03,r10R1D1.949 80)x.-0078 c is) er.e6 T5m0 ] 5 19.9377 eun9u sTO orn9N xmTn Hioleoh Gardens, H. 33018 Tec. zeaaa00 PAIC.._... ezav7e LII (mx.6$ 10.4.17 UP951FD ID 29n T99 _ Tel:(900)257-2016 Fox:(305)362-9272 —"----.—-- GARAG o2-21 DAB, . • T r ' \ 31N• I/2f%1�J/{'% .058• / EA VM E • FORMED STEEL 11�7\ DIST. fa%1' �Y o e 1-T/z'YIN. a 1 m SELF DRILLING SCREWS #B x 1' SELF CRILLNG SCREWS Z I .� DIST. I 3/16''RIYE]C STEEL RIVETS mos G q . OR H YULTIGRIP W/DOME HEAD 3/18•WNEx'STEEL HEAD l''','' �g AT AC O.C. MULTGRIP W/DOME HEAD r1 I AT 4B'O.C. Z I,-3/4'X6HENr n l 61 1/z-x 1-3/a•x.ose• p ° C1/4'DK LAG SCREWS 1/4'DKrSCflEWSFORMED 058' ►. DNAV TEEL D CZ in WOOD BU 1 4 AT AD5•I S'O ENI DS WOOD BU I µo 15 OCwIWL CZ ]m CrP�1 t" ¢ I D ( WSTRIPµ � WW'S P ADAPTER O¢ <Z 1FO RUBBER'NSROPPINO C:E1 RUBBER WSTRIPPINC Q U=o oso-y-9-1 ow u'WI"f e `Gf s3` �' S°Ss Ti .34ei—T Q b f 1.T90—I ` re BOTTOM SFAI OPTIONS a OT/UGC REVISED Rly1e2 with Ms Plaids I OPTION'A' OPTION 'Bbeading Code' AaiePlseaeWo °F .12 ^ Expired*Dale 2 20 WOOD BU K CONNECTION TO WOOD S :STRATF(WOOD SPECIFIC GRAVITY 56=0.55 KEN.) /54-J / ¢ m F. QWrPrwtdant W - o V TO INSTALLATION METHODS SHOWN ABOVE SHOWS 206 STP WOOD BUCK ATTACHMENT M ." TO WOOD STRUCTURES.IF THESE METHODS ARE FOLLOWED NO ADDINDNAL CALCUUTDONS/DESIGN r1 I. WILL BE REWIRED FOR DESIGN OF GARAGE DOOR ANCHORAGE ��,.{H CT.j FOR DOOR REPULC SAEO APPLIGTIOUS YITH NO ENGINEER OF RECORD,INSTALLATION MAY BE D2 p<LL VERIFIED AND APPROVED BY DIE BUILDING OFFICIAL UPON INSPECTION. ANCHOR SPACING FF Il ANCHORS STRUCTURE EMBED SPACING EDGE DIST. 8 E m C o 3/8'RIC SLEEVE BY'ALIT CONC. 1-I/4' e• 2' a U m Al I 3/8'CONFLEI BY'ELCD' FILLED BLOCK • 8' 3-3/4' 5•,3 o n • STEEL STRUCTURE BY OTHERS 3 B'DTNABDLT BY'OW' CONC. 1-1/2' B' 2-1/2' c 0°Z 0 n 5/16'X 1-5 B' MUST SUPPORT THE LOADS IMPOSED 3/B POWER-BOLT BY'POWERS' CONC. 2' B' 2' ¢ 0 V•D S BY DOOR SYSTEH 3/8'SLEEVE-ALL BY'SIIIPSONS' CONC. 1-1/2' 8' 3' mm o m AT 12'O.C. CONCRETE RD-3000 P51 MIN. cd1 6 15 p I i 5/16'OK BOLTS C-90 GROUT FILLED BLOCK I'm-2000 PSI LGN. H 0 V.2 r WITH WASHER&NUT WOOD BU K CONNECTION TO MASONRY S:°..• 1. 1 IIrAl'12'C.c.MAX. EDGE 0�. PRESSURE TREATED 1%6 STP 00000 JAMBS WHICH SNNL BE ANA WITH TO ��— I I I B GROUTED REINFORCED MASONRY BLOCK WALL OR CONC.COLUMN WITH �_// (I L"'q= 1/4'ULTRACON BY TELCO'PATH SPADING OF I a I - 3/y/1' 12'O.C.INTO GROUT FILLED BLOCK WALL,WITH 2-1/4'MIN.EMBED f,-�.-.- rw..r/ -.l '. '. $ 13'O.C.INTO 3000 PSI CONCRETE WITH 1-3/4'MIN.EMBED I 1-1 4'%2-1/2-X 14 GA R 2-1/Y MIN.EDGE DISTANCE / ° R 1� I 2N' 2'�,�, CONT.STEEL ACE 1I 1-1/2-I L GALV.STEEL 'f5 S g 0 R 1/4'TAPPER BY POWERS'WITH SPACING OF T1.O.C.INTO GROUT FILLED BLOCK WALL,WMR 1-1/2'MN.EMBED , IFLA2 T�6RACKETS f3'LONG _ 2-1/e%I'%14 CA Iiil4 g S 13'0.0 INTO 3000 PSI CONCRETE WITH 1-3/4'MIN.EMBED 1/i6'X 2-1/2 AT 12'O.C.IN DOOR OPNC. GLLV/. 3'YIN.EDGE DISTANCE FlILET WE1D5 AT 18'O.C.ABOVE DOOR DPNG. ASTENED ELTO IAA K PLATES ...IT 3/B'CONFLE(BY TELCO'OR AT 12'O.C.14X CONNECTED TO CONT.ANGLE W/(2)1/4-20X5/8'TRUSS HD. f" 3/8'LOT BY'NW.WITH SPACING OF W/(3)SPOT WELDS AT EACH SIDE SLATTED Y S.k LOCK NUT +,,'-'.n 23'0.5.INTO 3000 PSI CONCRETE WITH 2-1/2'MIN.EMBED IT S'S 5 a 3'MIN.EDGE DISTANCE CONTINUOUS ANGL ' K •NORSE TRACK CONTINUO(' ANC E TRACK lc$C x S 3/B•PIC SLEEVE BY'HILT N11H SPACING of TO WOOD BUCK ICLS)m. Jo CO••RE AND FII,Fo BLOCK TO'O.C.INTO GROUT FILLED BLOCK WALL,WITH 1-1/4'MIN.EMBED.4'MIN.EDGE DIST. 151/2C MIN.EDGE SI CO CRETE WITH 1-1/4'MIN.EMBED AND A TFRNATE TRACK INSTA EATON V111,1111A[:,HIAA q )pJ'•• ,A.ENMgF ''i d 2 PREPARATION OF JAMBS TOY OTHERS ' FOR NEW CONSTRUCTION ENGINEER OF RECORD OR ARCHITECT TO VERIFY -•:. I ADEQUACY OF AD D� SUPPORTING STRUCTURE TO SUPPORT LOADS IMPOSED _ O' S2 :YI- It I 8 FOR ODOR REPLACEMENT IN RETROFIT BUILDINGS PATH NO ENGINEER OF •[� j RECORD,0000 INSTALLATON MAY BE REVIEWED AND APPROVED BY 2L� I BUILDING OFFICUL UPON INSPECTION. �. � � "" ..fX�� OP �(/� drawing no. WNW Ex1ERIOR(4)LORD PER JAMB-(15.16'X 62 PS/I/2-291 Lb.Per FL '(ss RID�',..a'``^G� 02_21 MN6MUM INTERIOR(-)LOAD PER JAMB-(16.16'X 44 PSFV2-355.5 Lba per FL VYY/SAA)._`1SS '' • `rU111 11111 (sheet 401 5) • ' I ' i .500 F-1-.TSD , ��,,0. *PLASTIC COMPLIES WITH 5008 PANEL CHAPTER 26 OF FBC 1. ./-24 cA(.024)STEEL MIN. SEE EVIDENCE PAGE Z a.1.- 1.]65 1147 ,.725 Q z g 7/16.DIA.WASHER °' 0"i; Egg C (Al;" h l o it Il 0 x 3/4•Sus 21 ap• I B o�,iw O 1 T(T' ; O 3/6•FROM E105 WOW.51 II 1.600 a C R 0 5 1 I!,I 1 AND T O.C.MAX. WIDTH .176 F� 0 LL ti C YGid'u1y'II *EXTERIOR FRAME * INTERIOR FRAME rA 1 �' I ;II� x O 4 WAS _ d 18 1/8' RIGID PVC ONE PIECE INJECTION RIGID PVC ONE PIECE INJECTION 1 2 n (4) N /' I IIII' 0 1-5/8•FROM ENDS \ J S J O$ E III II`` AND 6-1/2"O.C.L41x. 'O ymj G D.LO. Q Z m . a. `� ; W LOUII -- ,.. . !Hi O/.0 PH. i�., ®; i 1 [ i 4 ) +c ilii nsx.Dez DSP r a J!,!111 GROOVE 6 L J - t...,........+ f i.. J Iin lili _ V—_ V _ Jr! V -T i I 1/4•P IC INNOONA7E PEAS!! in: ...E .!N y I s - ../ )M+ 3 ) c n,� I I 1!Y'SPOIL INNOVATIVE LPLASTIDS' A _ f r '0,-,,,E.:, 'r M I I NOA/15-0915.08 p Q A .. a ti, 0 T O N 1 Ili i—Y■r G GG rY■■F I e asc 1. ^ ANI' 8 E g !IIId v._r__ .1 s II. A ; °�� 6 8 oN�g iiiiit ;I !r tNCl 3 NIM . _1 gmm�o`i IIII 6 A......_.... f�..�......5 aa � � N D�2 f ;III • Q v , VI ! i!i (- r ��i( '"f Mill I I' .175 X.062 DEEP / rai % a / ( .! AIN� !I!i wBN^ I III I 11 g R I;I; 1 (4)/6 x a/r sus / INSIDE ELEVATION @ ¢3 e RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWSPROv€ g 11 i ',1, Aoao s /2o.c.wiu�X WINDOW DIES CAN BE IN ANY LOCATION IN DOOR SECTION o 0C4�J0 D< O „r.:JCe4`•�'ll !6 x 8/4•sus © A Aa<.<n. j2. B j 11 l l I 0 0/6•FROM ENDS 1]5%A62 DEEP APMMrV h!e ,.;.,TrD� n. „f ! 1 1 I AND 1-1/2.O.C.MAX. GROOVE /� �• 41Y'��� gr.m il.6 o (`Al�ll i��- �� �3W & nokpl Cab. .3 2 e8%J/a•SUS oo�YJ 0 3/6•FROM ENDS Y �� `11,1111!,11/!E! AND 7•o.c.MAX. � pPO.!H,S+ ..' 7/16"OIA WASHER .4c1; 1`):'JCEf+ "1p.'\ d I .....siilliskimmommomm E-- ODOR PANEL EXTERIOR - - �' 24 GA COM STEEL MIN. - :1 DOOR PANEL 15/16•MIN. D.L OPG. �TATEOF 61J� drawing' no. 24 Cl.(.024)STEEL MW. - GLAZING BRE S•// Dm..... �. OZ—`L1 WINDOW mom 'ES/ONA61�a111 (9hae(5of 5 J ' I