HomeMy WebLinkAboutWind Load Calculation PARADISE EXTERIORS
"Building Our Quality Reputation
One Customer At A Time"
SCC131150472
Property Information Building Information
Owner: WILLIAM&ELIZABETH TROMBLEY Wind Zone: 170 MPH,
Address: 5108 E SEMINOLE RD Exposure Category: C
FORT PIERCE,FL 34951 Minimum Building Dimension: 49 ft.
Mean Roof Height: 12 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
I Int 52 36 7 37.2 -40.4
2 Int 52 36 7 37.2 -40.4
3 End 52 36 7 37.2 -49.3
4 Int 52 36 7 37.2 -40.4
5 End 52 36 7 37.2 -49.3
6 Int 36 36 7 37.8 -41.0
7 Int 25 36 7 37.8 -41.0
8 Int 48 23 7 37.8 -41.0
_ _ ......................................
9 End 36 49 7 37.3 -49.6
10 End 25 24 7 37.8 -50.6
11 Int 36 49 7 37.3 -40.5
12 Int 51 36 7 37.2 -40.4
---------
..._.- -- __ ....................... ....---
.. - ... .......... ...... --
13 Int 36 60 7 36.8 -40.0
............. -.
14 Int -36 60 7 36.8 -40.0
_.....................1-........._...._.-.---- ..__._.------.........................
-- _ -- - --
15 End 52 36 7 37.2 49.3
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1
WINDOW ♦ DOOR INFORMATION
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone-10°/6 of least horizontal dimension or 40%of the mean roof height,whichever is smaller, but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING SHUTTERS
NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF SIZE DIMENSIONS MULLION REQ Y/NINA REQ Y/N
1 Int Window 7/8"Lam,IG FL15781.11 55 60 37.2 -40.4 73x63 5206 YES No
2 Int Window 7/8"Lam,IG FL15781.11 55 60 37.2 -40.4 73 x 63 5206 YES No
3 End Window 7/8"Lam,IG FL15781.11 55 60 37.2 -49.3 73 x 63 5206 No No
4 Int Window 7/8"Lam,IG FL15781.11 55 60 37.2 -40.4 73 x 63 5206 No No
5 End Window 7/8"Lam,IG FL15781.11 55 60 37.2 -49.3 1 73x63 5206 No No
6 Int Window 7/8"Lam,IG FL15780.8 55 65 37.8 -41.0 54x76.5 3606 No No
7 Int Window 7/8"Lam,IG FL15780.8 55 65 37.8 -41.0 54 x 76.5 2506 No No
8 Int Window 7/8"Lami IG FL15781.11 55 60 37.8 -41.0 73 x 63 48x23 No No
9 End Window 7/8"Lami IG FL15780.8 55 65 37.3 -49.6 1 54 x 76.5 36x49 No No
10 End Window 7/8"LamilG FL15781.11 55 60 37.8 -50.6 73 x 63 25x24 No No
11 Int Window 7/8"Lam.IG FL15780.8 55 65 37.3 -40.5 54x76.5 36x49 No No
12 Int Window 7/8"Lam,IG FL15781.11 55 60 37.2 -40.4 73 x 63 5106 No No
13 Int Window 7/8"Lami IG FL15780.8 55 65 36.8 -40.0 54 x 76.5 36x60 YES No
14 Int Window 7/8"Lam+IG FL15780.8 55 65 36.8 -40.0 1 54x76.5 36x60 YES No
15 End Window 7/8"Lami IG FL15781.11 55 60 37.2 -49.3 73 x 63 5206 No No