Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online _5- 12 ,/ ,S Page 1 of 4 !Fg � .vlr;4t'��I-,ivl_� BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff SCIS Site Map Links Search d JF!"'i!id, Product Approval k I USER:Public User L-%ra Product Aoproval Menu>Product or Avolication Search>Application List>Application Detail la � FL# Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Soft-Lite LLC Address/Phone/Email 10250 Philipp Parkway Streetsboro,OH 44241 (330)528-1136 PLanga n@sok-lite.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity Farabaugh Engineering and Testing,Inc Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan].King,P.E. Validation Checklist-Hardcopy Received Certificate of Independence FL15781 R7 COI (a)Certificate of Independence.odf Referenced Standard and Year(of Standard) Standard Year AAMA/W D MA/CSA 101/I.S.2/A440 2011 AAMA/W D MA/CSA 101/I.S.2/A440 2008 ASTM E1300 2004 ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 TAS 201,202,203 1994 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3e 1 SAInEOW... 1/3/2018 Florida Building Code Online Page 2 of 4 Product Approval Method Method 1 Option D Date Submitted 10/07/2017 Date Validated 10/10/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 15781.1 a. "Imperial LS DSL12"Double Extruded PVC Double Horizontal Sliding Window-(XX Slider Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15781 R7 II (a)Inst 15781.1.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.1 for Design Pressure Ratings,any FL15781 R7 AE (a)Eval 15781.1.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15781.2 b. "Imperial LS TSL12"Triple Slider Extruded PVC Triple Horizontal Sliding Window-(XOX Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15781. R7 II (a)Inst 1.578I..2.0f Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.2 for Design Pressure Ratings,any FL15781 R7 AE (a)Eval 15781.2.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15781.3 c."5300 DSL53(G5352)"Double Extruded PVC Double Horizontal Sliding Window-(XX Slider Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15781 R7 II (a)Inst 15781.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.3 for Design Pressure Ratings,any FL15.7�1__R7 AE 1aa)._Eval 1,ST8 1.3.pdf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15781.4 d."5300 DSL53(G5352)"Double Extruded PVC Double Horizontal Sliding Window-(XX Slider Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15781 R7 II (a)Inst 15781.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.4 for Design Pressure Ratings,any FL15781 R7 AE (a) Eval 15781.4.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15781.5 e."5400 SSL54(G5402)"Single Extruded PVC Single Horizontal Sliding Window-(OX or XO Slider Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15781 R7 II (a)Inst 15781.5.udf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.5 for Design Pressure Ratings,any FL15781 R7 AE (a)Eval 15781.5.Ddf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15781.6 f."5400 SSL54(G5402)"Single Extruded PVC Single Horizontal Sliding Window-(OX or XO Slider Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15781 R7 II (a)Inst 15781.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3e 1 SA1nEOW... 1/3/2018 Florida Building Code Online Page 3 of 4 Design Pressure:N/A Evaluation Reports Other:See INST 15781.6 for Design Pressure Ratings,any FL15/81 R7 AE (a)Eval 15781.6.1)df additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15781.7 g. "5400 TSLF54"Triple Slider Extruded PVC Triple Horizontal Sliding Window-(XOX Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15781. R7 II (a)Inst 15781-7.1)df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.7 for Design Pressure Ratings,any FL15781 R7 AE (a)Eval 15781.7.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15781.8 h."5400 TSLF54"Triple Slider Extruded PVC Triple Horizontal Sliding Window-(XOX Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15781 R7 II (a)Inst 15781.8.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.8 for Design Pressure Ratings,any FL15781 R7A[__Jal Eval....15781 8,gdf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15781.9 FSees"Barcelona"Model Extruded PVC Horizontal Sliding"Impact"Window,Missile 0I" Level"C"Excludes Wind Zone 3 and 4(XO or OX Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15781 R7 II (a)Inst 15781.9.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.9 for Design Pressure Ratings,any FL15781 R7 AE (a)Eval 15781.9.0f additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15781.10 j.Series"Barcelona"Model Extruded PVC Horizontal Sliding"Impact"Window,Missile "SSL30I" Level"D"Includes Wind Zone 4(XO or OX Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15781. R7 11 (a)List 15781.10.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.10 for Design Pressure Ratings, FL15781 R7 AE (a)Eval 15781.10.odf any additional use limitations,installation instructions and Created by Independent Third Party:Yes pr u a icu rs. 15781.11 k.Series"Barcelona"Model Extruded PVC Horizontal Sliding"Impact"Window,High "SSL30I" Velocity Hurricane Zone Large Missile(XO or OX Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15781 R7 II (a)Inst 15781.11.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.11 for Design Pressure Ratings, FL15781 R7 AE (a)Eval 15781.11.odf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product articulars. 15781.12 enes" arcelona"Model Extruded PVC Triple Horizontal Sliding"Impact"Window, "TSL30I" Missile Level"C"Excludes Wind Zone 3 and 4(XOX 1/4-1/2-1/4 and XOX 1/3-1/3-1/3 Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15781 R7 II (a)Inst 15781.12,odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.12 for Design Pressure Ratings, FL1.5781. R7 AE (a) Eval 15781.12.odf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15781.13 m.Series"Barcelona"Model Extruded PVC Triple Horizontal Sliding"Impact"Window, "TSL30I" Missile Level"D"Excludes Wind Zone 4(XOX 1/4-1/2-1/4 and XOX 1/3-1/3-1/3 Configurations) https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3e 1 SAInEOW... 1/3/2018 Florida Building Code Online Page 4 of 4 Limits of Use Installation Instructions Approved for use In HVHZ:No FL15781 R7 lI (a)Inst 15781.13.Ddf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.13 for Design Pressure Ratings, FL15781 R7 AE (a)Eval 15781.13.Ddf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15781.14 FnSLeries"Barcelona"Model Extruded PVC Triple Horizontal Sliding"Impact"Window, I" High Velocity Hurricane Zone Large Missile(XOX 1/4-1/2-1/4 and XOX 1/3-1/3-1/3 Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15781 R7 II (a)Inst 15781.14.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.14 for Design Pressure Ratings, FL15781. R7 AE (b)Eval 15781.14.odf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15781.15 o.Series"Barcelona"Model Extruded PVC Horizontal Sliding"Non-Impact"Window(XX "DSL30" Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15781 R7 II (a)Inst 15781.15.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.15 for Design Pressure Ratings, FL15781 R7 AE (a)Eval 15781.15.Ddf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15781.16 p.Series"Barcelona"Model Extruded PVC Triple Horizontal Sliding"Non-Impact"Window "TSL30" (XOX 1/4-1/2-1/4 and XOX 1/3-1/3-1/3 Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15781 R7 II (a)Inst 15781.16.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15781.16 for Design Pressure Ratings, FL15781 R7 AE (a)Eval 15781.16.odf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: rM M�j gq Credit Card Safe i https://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3e 1 SAInEOW... 1/3/2018 R .W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product Evaluation Report Date: A tigust 29,2017 Product Category Sub Category Manufacturer Product Name Soft-Lite LLC "BARCELONA" Windows Horizontal Slider 10250 Philipp Parkway Model"SSL301" Streetsboro,OH 44241 Sliding Window (330)528-3400 "Impact' Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F. Schmidt, P.E.(System ID#1998) for Soft-Lite LLC based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F. Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements including the"High Velocity Hurricane Zone". 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the"HVHZ",this product complies with Section 1626 of the FBC and does not require an impact resistant covering, 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-15781.11 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-15781.11 for size and design pressure limitations. 7. This product meets thew ter infiltration requirements for"HVHZ". uppo mg ocuments: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 03001826 TAS 201,202&203-94 Testing Evaluation Lab, Inc. Lyndon F.Schmidt, P.E. TEL 03001829 TAS 201,202&203-94 Testing Evaluation Lab, Inc. Lyndon F.Schmidt,P.E. TEL 03001832 TAS 201,202&203-94 Testing Evaluation Lab, Inc. Lyndon F.Schmidt, P.E. TEL 03001870 TAS 201,202&203-94 Testing Evaluation Lab, Inc. Lyndon F.Schmidt, P.E. 2. Miami Dade NOA Materials Testing 15-1201.11 Saflex°PVB Interlayer(Eastman Chemical Company) 15-0528.13 PVC Extrusions(Vision Extrusions Ltd.) 3. Drawing No. Prepared by Signed&Sealed by No. FL-15781.11 RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt, P.E. 4. Calculations Prepared by Sinned&Sealed by Anchoring RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt,P.E. �b16lg�it? ASTM E1300 Glass Load Lyndon F. Schmidt, P.E. SC � ����� 5. Quality Assurance ym0 E' Certificate of Participation issued by Farabaugh Engineering and m •'•,, Testing, Inc,certifying that Soft-Lite LLC is manufacturing products 4 :• No 43409 1 within a quality assurance program that complies with ISO/IEC _ 17020 and Guide 53. zr STATE GIF �0 '4tj Lyndon F.Schmidt,P.E. �� •.,[ ; °,tip ��" FL PE No.43409 Sheet 1 of 1 sr��is`Sf �~� 8/2912017 oftlite _ o�=09 3:6 .a- Z -N '.W•. g. zWindows oWrT I�•••••.. .... `C�;�� J O b Rl Bringing qut4lity IO liglit. SEE CHART FOR FRAME SIZES---] III�� �' ` z dm 10250 Philipp Parkway rr rEN�r o n z Streetsboro,Ohio 44241 a v a x 0 d rJ " " 9 m Pa 54`oa rm "BARCELONA" a < maan g LL E06 Model "SSL30l o a SLIDING WINDOW _ H N W Z W "IM PACT' Z r � Way _ W w GENERAL NOTES H o 0 �w 1. This product has been evaluated and is in compliance with the 6th Edition(2017) & < a Florida Building Code(FBC)structural requirements including the"High Velocity a a 3 Hurricane Zone"(HVHZ). 0 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. a 3. When used in the"HVHT'this product complies with Section 1626 of the FBC and does not require an impact resistant covering. o 0 4. For 2x stud framing construction,anchoring of these units shall be the same as that N shown for 2x buck masonry construction. w 5. Site conditions that deviate from the details of this drawing require further w engineering analysis by a licensed engineer or registered architect. Qe z a MAX. MAX. GLASS DESIGN PRESSURE(PSI) DIMENSION 6. This product meets the water infiltration requirements for the"HVHT'. FRAME D.LO. m DIMENSION TYPE POSMVE NEGATIVE o m TABLE OF CONTENTS 73.0"X 63.0"* 31.43T'x 54.375" GI +55.0 -60.0 -z SHEET# DESCRIPTION DATE: 4126117 2 I Typical elevations,design pressures and general notes 73.0"X 56.0" 31.437"x 47.375" Gl +55.0 -60.0 scuE N.T.S. E2 Horizontal cross sections 3 Vertical cross sectionsMG.BY: JK m 4 Buck and frame anchoring 73.0"X 48.0" 31.43T'x 39.375" Gl +60.0 65.0 cwc BY. LFS 3 N 5 Components ° Ho.: p RAM''" b 6 Bill of materials and glazing detail *Requires external stile reinforcement(Item#17) FL-15781.1 1 a N SHEET 1 OF 6 v NOTE: rr `���� * 1.Item#17 required for units greater 56"in height. 1-1/4"MIN. d EMB.(TYP.) N'• z° Q:\O` o m INTERIOR 1-1/,"MIN. INTERIOR Gjy` F N n EMB.(TYP.) i .......... �� o m m 15 5 C 28 15 5 ''���''ii +?��```` z o n o w 6 22 Z Z Q 4 Z 0 U e N i UO OJ m CW a a 5aaW y u o /\ o 0 2 E °Z oP cv ` 2 9 GI o O GI TOy " 2 �� /� EXTERIOR lU EXTERIOR C o0 0 G o r H E 1 Ny 1 2 3 3 3 3 2 HORIZONTAL CROSS SECTION 3 HORIZONTAL CROSS SECTION y U 2 Shown Direct to Masonry 2 Shown w/1 X Buck o f o 1-1/4"MIN. a 1-1/4"MIN. n EMB.(TYP.( F B EMB.(TYP.( `+ o C B F 1 s 15 5 INTERIOR 7 13 to 28 Gl 20 4 z is INTERIOR 0) o z 22 B tr w o0 21 G1 26 10 N ri a a e 9 8 9 EXTT3210R G 18 16 1 5 p 23 9 E are: 4126117 = C 17 27 14 9 EXTERIOR 15 SEENOTEI sc� N.T.S. I E E SEE NOTE 1 6 0M.BY: JK NOTE: 3 1.Iter111FJ boated 7-114"from CNN.BY: LFS N 1 HORIZONTAL CROSS SECTION �4�HORIZONTAL CROSS SECTION S HORIZONTAL CROSS SECTION �end and 1 at the center °RAWNC N0" r. 2 2X Buck Construction 2 2 (3 total). FL-15781.11 c D sNm2 or 6 p ec CH z— A Z— C is C 16 1 zd SEE a '���'••'••......• ``�� >> a C 16 1 p SEE NOTE 1 10 1�w NOTE 1 J 10 ����i�I�IIIN0` o m i SEE NOTE I 2 a N •: 11 A s i 0Z0 2 O 28 % e E o m e J 10 28 11 q — c` Mt 'ma00. `a a En 2 11 4 I 15 E a 4e 28 15 8 � ouZW m - 15 9 8 15 8 15 8 9 9 \ G1 z 15 G1 g o 9 INTERIORGI EXTERIOR INTERIOR EXTERIOR INTERIOR Fo EXTERIOR 15 9 15 9 1 / 8 15 $ 15 15 9 G1 oly o 4 O $ 15 4 O 8 8 a m 28 28F AD O 8 4 19 19 4 28 2 12 2 D12 28 19 nSEE SEE 10 OTE J 10 1 NOTE 1 J 1 2 12 W 16 SEE J 10 Q 16 SILICONE SEALANT _ SILICONE SEALANT NOTE 1 1 i F 3 3 16 SILICONESEALANT C C f� - G 3 H s A C W a s E E ^o d z i a s � J 1 VERTICAL CROSS SECTION 2 VERTICAL CROSS SECTION 3 VERTICAL CROSS SECTION <m w>E 4/26/17 n 3 2X Buck Corshuction 3 Shown w/IX Buck Shown Direct to Masonry scute N.T.S. d v owc,er: JK m NOTE: CWL 11Y.. LIS ; x 1.Item#J located 41/8W" ",17-3/8", -1 ° "G ND' n and 31-1/4"from Jamb stile end(4 totall. F1-15781.11 0 sir y3 OF 6 0 0 Q: n V T e:0 (� wI Z �•0�z O a ��Y•. 6J�z u of n 2TYP. •........: >�m 6"(TYF) SASH {� 4" ' Nni ��N��`�. zocoo I P.) 4"(TYP.J o o. z oN �T 6"VYP.) v u o o i 4 Qt m I I \\\VVVIII m a:z II — II Z 0 II II ; v I I 1Li d p I 2X BUCK F 8 a 2X II I 1XBUCK G z 1i II TYP. BUCK BUCK I I I DIRECT TO - o I FRAME I MASONRY H �, 3 v II MASONRY II (TYP.) o OPENING I ONRY OPENING I I 3 w II II s Z v o Y II < II o m I Jill :2 a0 �m F 0 BUCK ANCHORING FRAME ANCHORING a z a o n v N CONCRETE ANCHOR NOTES: N a. 1. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. w 2. Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to w maintain the min.edge distance to mortar joints,additional concrete anchors may be required to ensure the MAX.ON CENTER"dimension are not exceeded. 3. Concrete anchor table: _ ' _ Na 7 -9 MIN.CLEARANCE MIN.CLEARANCE ANCHOR ANCHOR MIN. ' SIZE EMBEDMENT TO MASONRY TO ADJACENT TYPE EDGE ANCHOR _z IT1N DATE 4/28 17 5 1/4" 1-1/4" 2" 4" o TAPCON® scuE N.T.S. ELCO ® 1/4" 1.1/4" 1" 4" m: JK m ? ON cm ar. LFS 3 WOOD SCREW INSTALLATI DMWING NO.: 1.Maintain a minimum 5/8"edge distance,I"end distance,&I"o.c.spacing of FL-15781.11 0 wood screws to prevent the splitting of wood. sNM 4 of 6 O R:\Clients\Soh-Lite Permanent\A-Florida Product Approvals\FL-15781 Horizontal Sliders\C-Drawings\FL-157816TH ED(2017)\FL-15781.9-1l.dwg,5.3 T � O P o J y 1-n a 0 � a 0 = o 0.067' 04 H 1 o�� 0 �n W W a 2.25' m 0.57' D A 1.21" o O 1.07'--I � '• 1 v � L o 2.87"' p 0.135'y n N0 0.84" 1.98, `7 To IJ W N O 0.86" - x 0 y s O m n 0.067' s 0.065'a Apt O A m D Z o 'o0 0.31" n aL l 91" fi A R y 0.735 O 1.05' 7 _ 0.627" i P A � N opp ZD3 T OC I---M-0.386' a �e Z O N O O a 0.089° �� o y n Z y a yN 2 1.05' o 0.124" N A ,00.41" 0 0.627"' a s 0 �e = 0.05' p L n U lyeb D � 11.111 1111//y Q p 0.75' / :� V.•\10ENdR .r :: 0.133" G No.43409 0.95' �2 s� _ gg $ PRODUCT: Documents Prepared By-. SOFT—LITE WINDOWS Lyndon F. Schmidti••••••"• Q�•'•••(f=�ne I� 1 z \ P.E. No. 43409 1,9,;,0;Z ; N o Z N /I/..Illi o7" CCD r- y PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. �1 to 1 7 12/17 REVISE GLAZING DETAIL jF1 P.O. Boz 230, Valrieo, FL 33595 n NO DATE COMPONENTS Phone No.: 813.859.9197 REVISIONS FBPE C.A. No. 9813 0 2017 R.W.BUILUINo CC18—Alts INC. BILL OF MATERIALS REM if MATERIAL A 1 X BUCK SG>=0.55 WOOD B 2X BUCK SG>=0.55 WOOD n C 1/4"MAX.SHIM SPACE �; 0 z 2` ' 6 0 8}O� D 1/4"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI �, E 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE //fit I 1 LL i o 0 o F #8-15 X 2-1/2"TRUSS HEAD SMS(I-3/8"MIN.EMBEDMENT) STEEL s N z G 1/4!'X 3-1/4"HWH ELCO OR ITW CONCRETE SCREW STEEL ` 'e E a z m,o H 1/4"X 2-3/4"HWH ELCO OR ITW CONCRETE SCREW STEEL \ ` V a y g 9 o C a J #10-16 X 2-1/2'PFH TEK SS SS a m d a I FRAME' PVC 4 oz 2 HS FIXED PANEL SPACER` PVC 3 w 3 WEEP HOLE COVER* PVC S 3a 4 DSL FRAME FILLER' PVC 5 DSL HANDLE SASH` PVC 6 KEEPER RAIL` PVC 7 LOCK RAIL` PVC7/8'THKK S K 8 DSL MAIN SASH* PVC 5/8"GLASS BITE z 9 GLAZING BEAD' PVC 1/8"ANNEALED r 10 DSL COVER' PVC O 0.090"SAFLEX PVB INTERLAYER ~ m g 11 ANTIUFTTRACK' PVC o0 � 12 ROLLER SILL TRACK ALUM. 13 REINFORCEMENT(6065-TS ALUM) ALUM. 1/8"ANNEALED D 0 14 REINFORCEMENT(6065-T5 ALUM) ALUM. AIR SPACE a a 15 REINFORCEMENT(6065-T5 ALUM) ALUM. 16 REINFORCEMENT(6065-T5 ALUM) ALUM. O 1/8"ANNEALED OR TEMPERED* m 17 REINFORCEMENT(6065-T5 ALUM) ALUM. 18 SPACER DOW 2400 SAS E 19 ROLLER ASSM. - Gl GLAZING DETAIL SEB INTERCEPT SPACER rA 20 LOCK - a 21 LOCK KEEPER - a N 22 #7 X 3/4"PFH TEK(LOCK) SS o g = 23 PVC COVER FOR HS REINFORCING BAR(Item#17) PVC *NOTE:TEMPERED G EQUIRED IN THE"HVHT'FOR EXTERIOR GLASS GREATER THAN 30 FEET ABOVE GROUND. u N h 26 #8 X 1"PPH TEK(KEEPER) SS N 27 #10.16X1-1/2"PFH TEK SS SS 28 WEATHERSTRIP(187-270 TRI-FIN) - y n THE APPROVED WHITE RIGID FVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY i a EXTRUDERS LICENSEES IN"AAMA CERTIFICATIONS PROGRAMS FOR RIGID PVC EXTRUSIONS". n m w z 72 n Iz 0 `o O a Z U a DATE 4126117 z SCME: N.T.S. C 5 E owc.BY, JK m CHK.BY: LFS 3 P r DAN7NG NO.: r Si FL-15781.11 0 SHEET_jL OF 6 V