SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. if this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline HD®,Timberline*Natural Shadow®,Timberline'American Harvest,and
FortitudeTM Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 14-1022.20 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 16-0811.11
MIAMMDAD;COUNTY Expiration Date:02/21/22
�LmiaApproval Date:02/09/17
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
SCOPE
This approves GAF Timberline HD®,Timberline*Natural Shadow®,Timberline Americana,Harvest',and
FortitudeTm Shingles as manufactured by GAF as described in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
GAF Timberline HDA' 13 '/4"x 39 318" TAS 110 Fiberglass reinforced heavy weight asphalt
Manufacturing roof shingle,with a laminate profile
Locations#1,2,3,4,5,6,7
GAF Timberline Natural 13 '/4"x 39 3/8. TAS 110 Fiberglass reinforced heavy weight asphalt
Shadow' roof shingle,with a laminate profile
Manufacturing
Locations#1,2,3,4,5,6, 7
GAF Timberline'American 13 '/a.x 39 3/8. TAS 110 Fiberglass reinforced heavy weight asphalt
Harvest`s roof shingle,with a laminate profile
Manufacturing
Locations#2,4,5,6
GAF FortitudeTm 13 '/a'x 39'/8" TAS 110 Fiberglass reinforced heavy weight asphalt
Manufacturing roof shingle,with a laminate profile
Locations#1,4
MANUFACTURING LOCATION
1. Tampa,FL
2. Michigan City, IN
3. Baltimore,MD
4. Myerstown,PA
5. Ennis,TX
6. Tuscaloosa,AL
7. Dallas,TX
NOA No.: 16-0811.11
M IAMMwe COUNTY Expiration Date:02/21/22
Approval Date:02/09/17
Page 2 of 6
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
Underwriters Laboratories,LLC ASTM D3462 4787344101 07/25/16
Underwriters Laboratories, Inc. ASTM D3462 I ICA48924 10/24/11
Underwriters Laboratories, Inc ASTM D3462 10CA21994 04/22/11
Underwriters Laboratories, Inc ASTM D3462 IOCA28717 07/26/11
Underwriters Laboratories, Inc. ASTM D3462 05CA47541 11/10/06
Underwriters Laboratories,Inc. ASTM D3462 06CA31580 11/30/06
PRI Asphalt Technologies, Inc. ASTM D3462 GAF-101-02-02 11/02/05
Underwriters Laboratories, Inc. ASTM D3462 06NK05159 08/09/06
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05
Underwriters Laboratories, Inc. ASTM D3462 02NK41809 08/11/02
Underwriters Laboratories, Inc. ASTM D3462 03NK26444 10/17/03
Center for Applied Engineering ASTM D3462 257989 05/13/97
Underwriters Laboratories,Inc. TAS 107 OINK45803 04/13/94
Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06
Underwriters Laboratories,Inc. TAS 107 04NK04273 02/20/04
Underwriters Laboratories,Inc. TAS 107 05CA42840 11/11/05
Underwriters Laboratories,Inc. TAS 107 02NK41811 11/11/02
Underwriters Laboratories, Inc. TAS 107 03CA35209 10/17/03
Underwriters Laboratories, Inc. TAS 107 04CA13850 08/30/04
Center for Applied Engineering TAS 100 257989 04/01/97
PRI Asphalt Technologies,Inc. TAS 100 GAF-044-02-01 01/13/04
PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05
PRI Asphalt Technologies,Inc. TAS 100 GAF-101-02-01 11/09/05
PRI Asphalt Technologies,Inc. TAS 100 GAF-116-02-02 03/23/06
PRI Asphalt Technologies,Inc. TAS-100 ELK-083-02-01 10/16/02
ELK-084-02-01 10/15/02
ELK-085-02-01 10/14/02
ELK-086-02-01 10/24/02
ELK-087-02-01 10/21/02
ELK-088-02-01 10/16/02
ELK-107-02-01 10/09/03
ELK-108-02-01 10/09/03
ELK-109-02-01 10/09/03
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 16-0511.11
MIAMF�IADE COUNTY Expiration Date:02/21/22
Approval Date:02/09/17
Page 3 of 6
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A',attached.
5. Nailing shall be in compliance with DetaiI'B',attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
M1AWDADE COUNTY
�K,121111,151
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 16-0811.11
MIAMMDADE COUNTY Expiration Date:02/21/22
Approval Date:02/09/17
Page 4 of 6
DETAIL A
COURSE LAYOUT
DECK
FULL
5th
17" OFF 4th
11" OFF 3rd
6" OFF 2nd
FULL 1st
\OA No.: 16-0811.11
MIAMFDADECOUNTY
� Expiration Date:02/21!22
Approval Date: 02/09/17
Page 5 of 6
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
39-3/811
(1 m)
14-1/2"-17-1/2" 14-1/2"-17-1/2"
(368-445mm) (368-445mm)
6-1/2"-9-1/2" 6-1/2"-9-1/2" ail guide line
13;311)4" (165-24,mm) (,65-24,mm) 53/4 -6
(146mm-159mm)
rz-2-i12" from bottom of shingle
,»-64
elf seal
adhesive
on back
ENHANCED NAILING PATTERN - six nails per shingle*
required by some local codes and required for enhanced wind coverage on certain products.
See limited warranty for details.
These shingles MUST be nailed a nominal 6" (152mm)from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
END OF THIS ACCEPTANCE
NO,a No.: 16-0811.11
MIAMFDADE COUNTY
Expiration Date:02/21/22
Approtal Date:02/09/17
Page 6 of 6
FILE COPY
RECEIVED
MAY 31 2018 NEMO etc.
Certificate of Authorization#32455
ST. Lucie Cout1€ ;FtftTtictln4] 353 Christian Street, Unit#13
iR Oxford,CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION • • •
Soprema, Inc. Evaluation Report 518010.06.09-1112
1640 rue Haggerty FL2569-1114
Drummondville,Qu6bec J2C 5P8 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 12:02/12/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to
the product(s),the Quality Assurance or the production facility location(s). NEMOI etc. requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen P.E. T -`e The facsimile seal appearing was authorized by Robert
'sFS�l;;•••"E'�;.' Nieminen,P.E.on 02/12/2018. This does not serve as an
Florida Registration No.59156,Florida DCA ANE1983 electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEMOJetc.
ROOFING COMPONENT EVALUATION:
SCOPE:1.
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012 2012
FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008
TAS 110 Accelerated Weathering ASTM D4798 2011
Enti Examination Reference Date
ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004
ERD(TST6049) Physical Properties 2757.02.05 02/03/2005
ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) Wind Resistance 2779.11.05-111 04/18/2007
ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007
ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-111 04/01/2010
ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-111 09/09/2010
ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.09-R2 10/05/2010
ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011
ERD(TST6049) ASTM D1970 540540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties/Tensile Adhesion S43530.02.14-1 02/21/2014
ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3S11) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control Service Confirmation Exp.07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012(04-12).
4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths;36 and 45 inch;meets ASTM D1970.
4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof
underlayment;available in 3.3 ft x 65 ft rolls; meets ASTM D1970.
4.4 Lastobond Shield HT is a self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof
underlayment; meets ASTM D1970.
NEMO ETC,LLC Evaluation Report 518010.06.09-1112
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.2569-1114
Soprema Roof Underlayments Revision 12:02/12/2018
Page 2 of 8
ONEMOletc.
4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment
available in two widths;36 and 45 inch; meets ASTM D1970.
4.6 Lastobond Pro HT-S is a self-adhering,woven polyethylene surfaced, high temperature,SBS modified bitumen roof
underlayment;meets ASTM D1970.
4.7 EnviroShield is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof
underlayment;meets ASTM D1970.
4.8 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;
meets ASTM D1970.
4.9 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen
roof underlayment;meets ASTM D1970.
4.10 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;
meets ASTM D1970.
4.11 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof
underlayment;meets ASTM D1970.
4.12 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,
with a 36-inch sheet width; meets ASTM D1970.
4.13 PrimeSource Grip-Rite Eave & Valley Protector is a self-adhering, glass-mat reinforced, sand-surfaced, SBS
modified bitumen roof underlayment,with a 36-inch sheet width; meets ASTM D1970.
4.14 RESISTO LB1244 is a self-adhering,glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,
with a 44-inch sheet width;meets ASTM D1970.
4.15 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI April 2012(04-12).
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVEROPTIONS
Wood or Slate or
Asphalt Nail-On Foam-On Composite
Underlayment Metal Composite
Shingles Tile Tile Shakes& Slate
Shingles
Lastobond TU HT Yes Yes Yes Yes Yes Yes
See 5.5.1
Lastobond Shield/Pro HT-N/ Yes No No No Yes Yes
RESISTO SA SMOOTH PLY 40
Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes
EnviroShield Yes No No Yes Yes Yes
NEMO ETC,LLC Evaluation Report 518010.06.09-1112
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12:02/12/2018
Page 3 of 8
ONEMOjetc.
TABLE 1: ROOF COVER OPTIONS
wood or Slate or
Underlayment Asphalt Nail-On Foam-On Metal Composite Composite
Shingles Tile Tile Shakes& Slate
Shingles
Lastobond Eaves Protection Sheet/ Yes No No No Yes Yes
Lastobond 195
Lastobond ECO /RESISTO LB1236,
Grip-Rite Eave&Valley Protector/ Yes No No No Yes Yes
RESISTO LB1244
Lastobond Smooth Seal HT Yes No No Yes Yes Yes
Colphene FR GR Yes Yes YesNo Yes Yes
See 5.5.1
5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations.
TABLE IA:ALLOWABLE TILE ADHESIVE/LINDERLAYMENT COMBINATIONS 1
Adhesive Florida Product Approval Underlayments
Dow TileBond- FL22525 Lastobond TU HT
ICP Adhesives Polyset®AH-160 FL6332 Lastobond TU HT or Colphene FR GR
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S,
Enviro5hield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to:
i Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB; Southern Yellow Pine;ASTM D41 primed
Southern Yellow Pine;ASTM D41 primed structural concrete.
Colphene FR GR applied to:
Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete.
Note:
While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming
with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours.
Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of
the self-adhering underlayment.
5.6.2 Bond-to-Insulation:
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S,
Enviro5hield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip-Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
Dens Deck Prime;SECU ROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on
tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional
and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D,
Testing Application Standard TAS 114,Appendix J or UL1807.
'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report 518010.06.09-1112
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12:02/12/2018
Page 4 of 8
ONEMOletc.
5.6.3 Bond to Mechanically Attached Base Layer:
Lastobond Shield, Lastobond Pro HTA RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO
LB1236, Grip-Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR
applied to:
ASTM D226,Type I or II felt;Sopra-G; Modified Sopra-G.
For installations under mechanically attached prepared roof coverings,base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems (Lastobond TU HT only), base layer shall be
attached in accordance with FRSA/TRI April 2012(04-12).
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012(04-12)does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the
underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) Elastoco)Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Elastocol600c
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered.
#3 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self-adhered, shall be thoroughly roll using hand roller and/or weighted
roller to ensure there are no voids, and ensure there are no voids/bridging at side and end-
laps.
#4 Maximum Design Pressure=-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC
1517.5.2)spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3),equally spaced rows
in the center of the sheet.
Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered
5.6.4.1 All other direct-deck, adhered Soprema underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of-45 psf.
NEMO ETC,LLC Evaluation Report 518010.06.09-R32
Certificate of Authorization#31455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12:02/12/2018
Page 5 of 8
ONEMOletc.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table IA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment
density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117.
Assemblies marked with an asterisk" carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention
Data Sheet 1-29(January 2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,RESISTO LB1236,
Grip-Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after
installation.
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT or Lastobond Pro HT-
S,EnviroShield shall not be left exposed for longer than 90-days after installation.
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)):
When loading roof tiles on the underlayment in direct-deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIREcT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum
Slope
Flat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack
shall be inverted,followed by 8 tiles high 6:12
on slope,as shown below)
Lastobond TU HT
Lugged
Colphene FR GR Flat Max.10-tile stack 5:12
Lugged Max.10-tile stack 6:12
NEMO ETC,LLC Evaluation Report 518010.06.09-1112
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R14
Soprema Roof Underlayments Revision 12:02/12/2018
Page 6 of 8
NNEMO I etc.
6. INSTALLATION:
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol 600c or
RESISTO EXTERIOR PRIMER(if applicable).
6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S, EnviroShield, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond
Smooth Seal HT,RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Colphene FR GR:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.3.2 Non-Tile Applications:
While priming is optional,Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR
PRIMER if the final roof cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of
release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane
tight. Firmly roll the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and
staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed
using either heat-welding or hot air welding techniques.
When installing at slopes above 8:12, Soprema recommends back-nailing in the overlap area at the top of the
sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction.
For valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall
outside the scope of FRSA/TRI April 2012(04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See
Table 2 herein,and Soprema published requirements for tile staging.
REQUIREMENTS:7. BUILDING PERMIT
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
NEMO ETC,LLC Evaluation Report 518010.06.09-1112
Certificate afAuthorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.2569-1114
Soprema Roof Underlayments Revision 12:02/12/2018
Page 7 of 8
ONEMO I etc.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements.
The following plants have qualified products under their respective physical properties specifications.
Plant Specification Product(s)
Lastobond Shield,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,
Drummondville, Lastobond Pro HT-N,Lastobond Pro HT-5,EnviroShield,Lastobond 195,
ASTM D1970 Lastobond Eaves Protection Sheet,Lastobond Eco,Lastobond Smooth
QC(Canada) Seal HT,RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley
Protector,RESISTO LB1244
ASTM D1970&FRSA/TRI 04-12 Colphene FR GR
Wadsworth,OH Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco,
ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite
Eave&Valley Protector,RESISTO LB1244
ASTM D1970&FRSA/TRI 04-12 Lastobond TU HT;Colphene FR GR
Gulfport,MS Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco,
ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite
Eave&Valley Protector,RESISTO LB1244
QUALITY9.
UL, LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Report 518010.06.09-1112
Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R14
5oprema Roof Underlayments Revision 12:02/12/2018
Page 8 of 8