HomeMy WebLinkAboutProduct Approval y• � M IAM MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,R(x)m 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Fk rida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eo%/ec0n0my Gardner Asphalt Corporation 4161 W. 7'Avenue Tampa, FL. 33605 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be >_ used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product 0 or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements LU of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. a !oy w 7 LL DESCRIPTION: Gardner Underlayments d` UJ ® o LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following w statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. °( RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and ..t...11 t. _....:i..M. C .....:,.., ....t.. : 1. :... ..• •t... .,....•♦ ,.c.l,. A...1A. -"f4r ,:..I k D •� ROOFING COMPONENT APPROVAL Cateeorv: Roofing tiuh-( atcyor�: Underlayment Material: Asphalt TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description APOC Tuff-Felt 26 36"x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underfayment,2 Manufacturing square#30. Location #1, 2 United FGUR20 36!'x 72' rolls ASTM D 226 Type 11 Asphalt Saturated Felt underlayment, 2 Manufacturing square#30. Location W. 2 APOC Tuff-Felt 46 36"x 144'rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment,4 Manufacturing square#I5. Location #1, 2 United FGUR10 36'x 144'rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment,4 Manufacturing square#15. Location #1, 2 United FGUR70 18" x 72' rolls ASTM D 226 Type H Asphalt Saturated Felt undcrlayment. 1 Manufacturing square#30. Location #1, 2 GatorSkin 42" x 285.8' rolls ASTM D 226 Type 11 Synthetic roof underlayment comprised Manufacturing of layers of polyolefin film. Location #3 Weather-Armor CX-L 37.25" x 145' rolls ASTM D 226'type 11 High strength hybrid underlayment Manu%acturing comprised of two layers of polyolefin and Location #3 polyester synthetic fabric with a thin layer of modified bitumen between the two plies. Weather-Armor SB-1 36" x 65' 8"rolls ASTM D 1970 Glass fiber reinforced, polymer modified .,-1,.,1► -At"-411--1 } r MANUFACTURING LOCATIONS: 1. Tacoma,WA. 2. Eutaw,AL. 3. Hangzhou,China. 4. Springville,AL. EVIDENCE SUBMITTED: Test Agency Test Identi tier Test Name/Report Date PRI Construction Materials GGI-100-02-01 ASTM D 226 06/22/12 Technologies GGI-101-02-01 ASTM D 226 06/22/12 GGI-132-02-01 ASTM D 226 04/28/15 GGI-176-02-01 ASTM D 226 09/26/16 GGI-178-02-01 ASTM D 1970 10/25/16 INSTALLATION I. Gardner Underlayments listed herein shall be installed in strict compliance with applicable Building Codes. 2. Gardner Underlayments listed herein shall be installed with a minimum 4-inch head lap and 6-inch side laps. 3. APOC-Tuff Felt 26, United FGUR20,APOC-Tuff Felt 46, United FGUR10, United FGUR70,GatorSkin,and Weather Armor CX-L shall be fastened with corrosion resistant tin-caps and approved roofing nails spaced 6 inches o.c. minimum at all laps and three staggered rows fastened at 12 inches o.c.minimum in the field of the roll.Nails shall be driven flush and 90 degrees to the roof deck. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city, state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. APPROVED w�wEnAoe BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a cun-ew .Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Weather-Armor SB-1 shall not be hot mopped; refer to manufacturer's published literature for product compatibility. 4. Gardner Underlayments listed herein are components used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance. 5. Gardner Underlayments listed herein shall not be left exposed as a temporary roof for longer than 30 days of application. 6. APOC-Tuff Felt 26, United FGUR20, APOC-Tuff Felt 46, United FGUR10, and United FGUR70 may be used with Asphalt shingles, Wood shakes and shingles, Non-structural metal roofing, quarry slate, and as an anchor sheet in tile roof assemblies. 7. GatorSkin, Weather Armor CX-L, and Weather-Armor SB-1 may be used with Asphalt shingles, Wood shakes and shingles,Non-structural metal roofing,and quarry slate. & Gardner Underlayments listed herein may be used with any approved roof covering Notice of Acceptance listing Gardner Underlayments listed herein as a component part of an assembly in the Notice of Acceptance. If Gardner Underlayments listed herein is not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance, and fire testing results. 9. For fire classification of specific roof assemblies using Gardner Underlayments listed herein refer to a current Approved Roofmg Materials Directory for fire ratings of this product. 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE