HomeMy WebLinkAboutDrawing WIND LOAD ANALYSIS
COMPONENTS AND CLADDING Wuaoow s DOOR
BLDG.:
00
LENGTH=45' CD
WIDTH=70'
HEIGHT=15'(SEE SKETCH BELOW)
00
BASIC WIND SPEED=170 MPH v
WIND STANDARD:ASCE 7-10,FBC 2017 6TH EDITION Lu m
EXPOSURE: NON-COASTAL O U
z °
LL U
Z 'Q^
L;
BASIC WIND SPEED V:170 MPH U o
IMPORTANCE FACTOR I NA W E
EXPOSURE CATEGORY :C m
RISK CATEGORY :2 O J x
MEAN ROOF ELEVATION H :15 FT. LJJ
TRIBUTARY LOAD AREA A :10 FT' a LL. 3:
0
ELEVATION OF OPENING =15 FT. N
I
Kh = 0.85 (TABLE 6-3,PAGE 79)
Kz = 0.85 (TABLE 6-3,PAGE 79)
Kd = 0.85 (TABLE 6-3,PAGE 80)
Kzt= 1.00 (TOPOGRAPHIC FACTOR-FIGURE 26.8-1,PG.252)
VELOCITY PRESSURE Qh=.00256 Kh Kzt Kd V'= 53.38 PSF
VELOCITY PRESSURE Qz=.00256 Kh Kzt Kd V'= 53.36 PSF
GCp COEFFICIENTS (FIGURE 30.6-1,PG.348)
ZONE 4= +1.00 -1.10
ZONE 5= +1.00 -1.40
GCpi COEFFICIENTS = + .18 - .18 (TABLE 26.11-1,P258) $
iw m
DESIGN PRESSURE P=Qh(GCp-GCpi)x.6 (AS PER FBC 1609.1.5) W o o W
DESIGN PRESSURE P=Qz(GCp-GCpi)x.6 (AS PER FBC 1609.1.5) :DO a m
o oLL > ,
ZONE 4=+37.8 PSF 1-41.0 PSF 0 .0 IY -,
(ZONE 5=+37.0 DSC/-50.6 PSF �^WORST CASE o 0 a 0 0
o c c
•ENGINEER SEAL NOT REQUIRED FOR BUILDING STRUCTURE<30'-0" Q 3 z o V a: J m
m m
u Q •+
i
z
O
U U
GENERAL NOTES:
1.REPLACE EXISTING NON-IMPACT
WINDOWS &DOORS WITH NEW IMPACT RATED
WINDOWS&DOORS AS SHOWN D E S 1 G N
2.REFER TO APPROVED FL#'S FOR 1B DESIGN & PERMITTING,INC.
PRODUCT SPECIFICATIONS& 6499 P O W E R L I N E RD., #203
ATTACHMENTS. FORT LAUDERDALE, FL. 33309
TEL. 754-701-7126
3.ALL PRODUCTS ARE IMPACT RATED WWW•1 6 D T E ti g,. M
&APPROVED FOR USE IN THE HVHZ. OIB Design&Permitting Inc.2 2017
WINDOW&DOOR LEGEND
NEW WINDOW
I
NEW WINDOW
�{ NEW WINDOW SCALE: AS NOTED
CHECKED BY:
DRAWN BY: JBD
p
ISSUE DATE: 06/04/18
NEW DOOR
4� SHEET# P 1
bw o[z
-- --- --- -- - -- - - --- - -- -- �O - �O
OVERHANG 122- GARAGE 23
--
I
21 li
6-0' COVERED I
ZONES 9 10 11 7 PORCH -- -----------------I
I 12 13 I I
I
'^ Ix" ..011 I 14
�Z
v O ABOVE
MASTER
BEDROOM I
I
BATHROOM I
FAMILY KITCHEN
ROOM
I
I
G.BATH 15
I
MASTER
BEDROOM
DINING ROOM
DORMERS
ENTRY 19 20 BEDROOM 2 16
"x" "0"
6'-0'5 O ABOVE
ZONE 3O 1 2J
"x" "o" "x" "x" "o" WINDOWS&DOORS LAYOUT I I
4O OVERHANG 17 6'-0' SCALE:3132"=1'-0'
ZONE5
WINDOWS&DOORS SCHEDULE
Approval Mull Mull Approval Allowable Mull
Mark TYPE SERIES Room Location Frame Size Number Allowable DP Zoning Site Pressures Required Span Number Pressures
1 FGD FIBERGLASS ENTRY 36"X80" FL#17184.5 +50.0/-50.0 4 +37.8/-41.0 NO
2 SL FIBERGLASS ENTRY 12"X 80"
3 FX PW-8300 DEN 703/4"X353/8" FL#13010.4 +55.0/-55.0 4 +37.8/-41.0 NO
4 HR HS-8200 DEN 1093/8"X601/4" FL#16736.2 +60.0/-60.0 4 +37.8/-41.0 NO
5 SH 8100 MASTER BEDROOM 52"X613/4" FL#5823.1 +67.5/-67.S 5 +37.8/-50.6 NO
6 SH SH-8100 MASTER BEDROOM 251/4"X613/4" FL#16177.1 +70.0/-70.0 5 +37.8/-50.6 NO
7 SH SH-8100 MASTER BATHROOM 513/4"X493/8" FL#16177.1 +70.0/-70.0 5 +37.8/-50.6 NO
8 FX PW-8300 FAMILYROOM 981/4"X351/2" FL113010.3 +70.0/-70.0 4 +37.8/-410 NO
9 SL FIBERGLASS FAMILY ROOM 12"X 80"
10 FGD FIBERGLASS FAMILYROOM 68"X80" FL417184.10 +50.0/-50.0 4 +37.8/41.0 NO
11 SL FIBERGLASS FAMILYROOM 12"X80"
12 HR HS-8200 KITCHEN 48"X44" FL#16735.1 +60.0/-60.0 4 +37.8/41.0 NO
13 FGD FIBERGLASS KITCHEN 36"X80" FL#17184.9 '+50.0/-50.0 4 +37.8/-41.0 NO
14 SH SH-8100 BEDROOM 353/4"X615/8" FL#16177.1 +70.0/-70.0 4 +37.8/-41.0 NO
15 SH SH-8100 GBATH 251/4"X493/8" FL#16177.1 +70.0/-70.0 4 +37.8/41.0 NO
16 SH SH-8100 BEDROOM 251/4"X491/2" FL#16177.1 +70.0/-70.0 4 +37.8/-41.0 NO
17 HR HS-8200 BEDROOM 723/4"X615/8" FL#16736.1 +60.0/-60.0 5 +37.8/-50.6 NO
18 HR HS-8200 DINING ROOM 723/4"X615/8" FL#16736.1 +60.0/-60.0 4 +37.8/41.0 NO
19 5H SH-8100 DORMERS 353/4"X243/4" FL#16177.1 +70.0/-70.0 4 +37.8/41.0 NO
20 SH SH-8100 DORMERS 353/4"X243/4" FL#16177.1 +70.0/-70.0 4 +37.8/-41.0 NO
21 FGD FIBERGLASS GARAGE 36"X80" FL#15213.1 '+65.0/-65.0 4 +37.8/-41.0 NO
22 SH SH-8100 GARAGE 353/4"X493/8"1 FL116177.1 J +70.0/-70.0 4 +37.8/-41.0 NO
23 SH SH-8100 GARAGE 353/4"X493/8"I FL#16177.1 1 +70.0/-70.0 5 +37.8/-50.6 NO