Loading...
HomeMy WebLinkAboutDrawing WIND LOAD ANALYSIS COMPONENTS AND CLADDING Wuaoow s DOOR BLDG.: 00 LENGTH=45' CD WIDTH=70' HEIGHT=15'(SEE SKETCH BELOW) 00 BASIC WIND SPEED=170 MPH v WIND STANDARD:ASCE 7-10,FBC 2017 6TH EDITION Lu m EXPOSURE: NON-COASTAL O U z ° LL U Z 'Q^ L; BASIC WIND SPEED V:170 MPH U o IMPORTANCE FACTOR I NA W E EXPOSURE CATEGORY :C m RISK CATEGORY :2 O J x MEAN ROOF ELEVATION H :15 FT. LJJ TRIBUTARY LOAD AREA A :10 FT' a LL. 3: 0 ELEVATION OF OPENING =15 FT. N I Kh = 0.85 (TABLE 6-3,PAGE 79) Kz = 0.85 (TABLE 6-3,PAGE 79) Kd = 0.85 (TABLE 6-3,PAGE 80) Kzt= 1.00 (TOPOGRAPHIC FACTOR-FIGURE 26.8-1,PG.252) VELOCITY PRESSURE Qh=.00256 Kh Kzt Kd V'= 53.38 PSF VELOCITY PRESSURE Qz=.00256 Kh Kzt Kd V'= 53.36 PSF GCp COEFFICIENTS (FIGURE 30.6-1,PG.348) ZONE 4= +1.00 -1.10 ZONE 5= +1.00 -1.40 GCpi COEFFICIENTS = + .18 - .18 (TABLE 26.11-1,P258) $ iw m DESIGN PRESSURE P=Qh(GCp-GCpi)x.6 (AS PER FBC 1609.1.5) W o o W DESIGN PRESSURE P=Qz(GCp-GCpi)x.6 (AS PER FBC 1609.1.5) :DO a m o oLL > , ZONE 4=+37.8 PSF 1-41.0 PSF 0 .0 IY -, (ZONE 5=+37.0 DSC/-50.6 PSF �^WORST CASE o 0 a 0 0 o c c •ENGINEER SEAL NOT REQUIRED FOR BUILDING STRUCTURE<30'-0" Q 3 z o V a: J m m m u Q •+ i z O U U GENERAL NOTES: 1.REPLACE EXISTING NON-IMPACT WINDOWS &DOORS WITH NEW IMPACT RATED WINDOWS&DOORS AS SHOWN D E S 1 G N 2.REFER TO APPROVED FL#'S FOR 1B DESIGN & PERMITTING,INC. PRODUCT SPECIFICATIONS& 6499 P O W E R L I N E RD., #203 ATTACHMENTS. FORT LAUDERDALE, FL. 33309 TEL. 754-701-7126 3.ALL PRODUCTS ARE IMPACT RATED WWW•1 6 D T E ti g,. M &APPROVED FOR USE IN THE HVHZ. OIB Design&Permitting Inc.2 2017 WINDOW&DOOR LEGEND NEW WINDOW I NEW WINDOW �{ NEW WINDOW SCALE: AS NOTED CHECKED BY: DRAWN BY: JBD p ISSUE DATE: 06/04/18 NEW DOOR 4� SHEET# P 1 bw o[z -- --- --- -- - -- - - --- - -- -- �O - �O OVERHANG 122- GARAGE 23 -- I 21 li 6-0' COVERED I ZONES 9 10 11 7 PORCH -- -----------------I I 12 13 I I I '^ Ix" ..011 I 14 �Z v O ABOVE MASTER BEDROOM I I BATHROOM I FAMILY KITCHEN ROOM I I G.BATH 15 I MASTER BEDROOM DINING ROOM DORMERS ENTRY 19 20 BEDROOM 2 16 "x" "0" 6'-0'5 O ABOVE ZONE 3O 1 2J "x" "o" "x" "x" "o" WINDOWS&DOORS LAYOUT I I 4O OVERHANG 17 6'-0' SCALE:3132"=1'-0' ZONE5 WINDOWS&DOORS SCHEDULE Approval Mull Mull Approval Allowable Mull Mark TYPE SERIES Room Location Frame Size Number Allowable DP Zoning Site Pressures Required Span Number Pressures 1 FGD FIBERGLASS ENTRY 36"X80" FL#17184.5 +50.0/-50.0 4 +37.8/-41.0 NO 2 SL FIBERGLASS ENTRY 12"X 80" 3 FX PW-8300 DEN 703/4"X353/8" FL#13010.4 +55.0/-55.0 4 +37.8/-41.0 NO 4 HR HS-8200 DEN 1093/8"X601/4" FL#16736.2 +60.0/-60.0 4 +37.8/-41.0 NO 5 SH 8100 MASTER BEDROOM 52"X613/4" FL#5823.1 +67.5/-67.S 5 +37.8/-50.6 NO 6 SH SH-8100 MASTER BEDROOM 251/4"X613/4" FL#16177.1 +70.0/-70.0 5 +37.8/-50.6 NO 7 SH SH-8100 MASTER BATHROOM 513/4"X493/8" FL#16177.1 +70.0/-70.0 5 +37.8/-50.6 NO 8 FX PW-8300 FAMILYROOM 981/4"X351/2" FL113010.3 +70.0/-70.0 4 +37.8/-410 NO 9 SL FIBERGLASS FAMILY ROOM 12"X 80" 10 FGD FIBERGLASS FAMILYROOM 68"X80" FL417184.10 +50.0/-50.0 4 +37.8/41.0 NO 11 SL FIBERGLASS FAMILYROOM 12"X80" 12 HR HS-8200 KITCHEN 48"X44" FL#16735.1 +60.0/-60.0 4 +37.8/41.0 NO 13 FGD FIBERGLASS KITCHEN 36"X80" FL#17184.9 '+50.0/-50.0 4 +37.8/-41.0 NO 14 SH SH-8100 BEDROOM 353/4"X615/8" FL#16177.1 +70.0/-70.0 4 +37.8/-41.0 NO 15 SH SH-8100 GBATH 251/4"X493/8" FL#16177.1 +70.0/-70.0 4 +37.8/41.0 NO 16 SH SH-8100 BEDROOM 251/4"X491/2" FL#16177.1 +70.0/-70.0 4 +37.8/-41.0 NO 17 HR HS-8200 BEDROOM 723/4"X615/8" FL#16736.1 +60.0/-60.0 5 +37.8/-50.6 NO 18 HR HS-8200 DINING ROOM 723/4"X615/8" FL#16736.1 +60.0/-60.0 4 +37.8/41.0 NO 19 5H SH-8100 DORMERS 353/4"X243/4" FL#16177.1 +70.0/-70.0 4 +37.8/41.0 NO 20 SH SH-8100 DORMERS 353/4"X243/4" FL#16177.1 +70.0/-70.0 4 +37.8/-41.0 NO 21 FGD FIBERGLASS GARAGE 36"X80" FL#15213.1 '+65.0/-65.0 4 +37.8/-41.0 NO 22 SH SH-8100 GARAGE 353/4"X493/8"1 FL116177.1 J +70.0/-70.0 4 +37.8/-41.0 NO 23 SH SH-8100 GARAGE 353/4"X493/8"I FL#16177.1 1 +70.0/-70.0 5 +37.8/-50.6 NO