HomeMy WebLinkAboutProduct Approval (3) 1/13/2018 Florida Building Code Online
acts Nome{ Log in Y User Registration t Hot Topics Submit Surcharge ( Stats&Facts Publications ? FBC Staff l` SCIS Site Map Links, Search+i
Product Approval
` USER:Public User
Product Approval Menu>Product or Application Search>Application US >Application Detail
<r 5, FL#
- 4t
FL13010-RS GI VOI to•3
RisApplication Type
Code Version 017
Application Status pproved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Custom Window Systems Inc.
Address/Phone/Email 1900 SW 446 Avenue
Ocala,FL 34474
(352)368-6922 Ext 245
ine@cws.cc €
1
Authorized Signature Kevin Pine r
kpine@cws.cc
i
Technical Representative ]ay Lathrop
Address/Phone/Email 1900 SW 44th Ave
Ocala,FL 34474
(352)368-6922 Ext 291
j jlathrop@cws.cc•
I
Quality Assurance Representative Arturo Monteverde
Address/Phone/Email 1900 SW 44th Ave
Ocala,FL 34474
(352)368-6922 Ext 221
amonteverde@cws.cc
Category Windows
Subcategory Fixed
Compliance Method Certification Mark or Listing
A
Certification Agency Keystone Certifications,Inc.
Validated By Steven M.Urich,PE
Validation Checklist-Hardcopy Received
i�
Referenced Standard and Year(of Standard) Standard. Year
AAMA/WDMA/CSA 101/I.S.2/A440-05 2005
HAMA/WDMA/CSA 161/I.S.2/A440=08 2008 i
ASTM E1886-05 2005•
ASTM E1996-05 2065
G PA TAS 201/202/203 1994 il
h
Equivalence of Product Standards
Certified By
https:llwww.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgvQEb8FEH6OVrs5wFsWUkbaFoga3237SsZ56feCsOc92Q%3d%8d -1/3
1/1312018 Florida Building Code Online
Product Approval Method Method i Option A
Date Submitted 09/29/2017
Date Validated 10/02/2017
Date Pending FBC Approval
Date Approved 10/07/2017
Summa_ryof Products
FL# Model,Number or Name LDescription
13010.1 PW-8150 PVC Fixed Window PW-8150 PVC fig/Fin Fixed Window
Limits of Use Certification Agency.Certificate
Approved for use in HVHZ:Yes FL13010 R5 C CAC CAR 138=1357,pdf
Approved for use outside HVHZ:Yes FL13010 R5 C CAC CAR 138-1362.pdf
Impact Resistant:Yes FL13010 R5 C CAC CAR_138-552.pdf i
Design Pressure:N/A Quality,Assurance Contract Expiration Date
Other:PW-8150,36"x 72"and 72"x 76"see installation 09/14/2019
detail for DPs.Large Missile Impact.In HVHZ may only be ;Installation Instructions
used up to 30ft above grade.Glass complies to ASTM E1300- FL1301.0 RS .II CWS-433D.pdf
04, Verified By:.Lucas A.Turner$8201
Created by Independent Third Party:Yes
Evaluation Reports
FL13010 RS AE EvalReport433D_;13df
Created by Independent Third Party:Yes
13010.2 PW-8150 PVC Fixed Window PW-8150 PVC Flg/Fin Fixed Window,Continuous Head&'Sill.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL13010 R5 C CAC CAR 138-261e2.pdf.
Approved for use outside HVHZ:Yes FL13010 R5 C CAC CAR 138-705e2.odf.
Impact Resistant:Yes FL13010 R5 C CAC CAR 138-M(50,ndf
Design Pressure:+67,5/-67.5 Quality Assurance Contract Expiration'Date
Other:Large Missile,Dip=+/-67.5 psf,Max.size 74 1/8"x 08/12/2019
72".Outer lite must be safety glass above 30 ft.In HVHZ. Installation Instructions
Glass complies to ASTM E1300-04: FL13010 R5 11 CWS-510C.)df
Verified By: Lucas A.Turner 58201
Created by Independent Third Party:Yes
Evaluation Reports
FL130'10-RS AE EvalReoort510C.odf
Created by Independent Third Parry:Yes
... ..
13010.3 PW-8300 PVC Fixed Window PW-8300 PVC Fixed Window,,120"x 48".
6�u
of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL13010 RS C CAC CAR 138-258e2 odf
Approved for use outside HVHZ:Yes FL13010 R5 C CAC CAR 138-481e2 Ddf
Impact Resistant:Yes FL13010 R5 C CACCAR 138-482e2.Ddf
Design Pressure:+70/-70 Quality Assurance Contract Expiration Date 4
Other:PW-8300,120"x 48",DP= +J-70 psf.Large Missile 04/09/2019
Impact.Glass complies to ASTM E1300-04. Installation Instructions
FL13010'R5 II CWS-373C.odf
Verified By:Lucas A.Turner,58201
Created by Independent Third Party:Yes
Evaluatlon,Reports
FL13010RS AE EvaiReoort373C pdf
Created by independent Third Party:Yes
__.........__.............._........_..__.._.__..
13010.4 PW-8300 PVC Fixed Window PW-8300 PVC Fig/Fin Fixed Window.
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL13010 R5 C CAC CAR 138-1693,0f
Approved for use outside HVHZ:Yes FL13010 R5 C CAC CAR 138-1320 bdf
Impact Resistant:Yes I FL13010 R5 C CAC CAR 1-38-2S0e2 Pdf
Design Pressure:N/A FL13010 RS C CAC CAR`138-274e2 o4f
Other:Large Missile Impact,See Installation Drawings for Fi 1 X010 RS C CAC CAR 138-457e2.Ddf
Max.size and DP's.Outer lite must be safety glass above 30 ft. FL13010_RS C CAC CAR 138-465e3.odf
in HVHZ.Glass complies to ASTM E1300-04. FL13010 R5 C CAC CAR 138-534 gdf €,
FI-1361D R5 C CAC CAR'138-730e2:odf
FL13010 RS C CAC CAR 138-739Q pelf
Quality Assurance Contract Expiration Date
04/29/2018
Installation Instructions
FL13010 RS 11 CWS-159E.pdf
Verified By: Lucas A.Tumer 58201 1
Created by Independent Third Party:Yes x:
Evaluation Reports
hffps://www.floridebuilding.orgtpr/pr app dtl.aspx?param=wGEVXQwtDgvgEb8FEH60Vrs5wFsWUkbaFo9a3237ssZ561eCsOc92Q%o3d°/`3u 213
111312018 Florida Building Code Online
l.FL13010 R5 AE EvaiReDOrt159E.D&
ff Ereated by Independent Third Party:Yes
llactt ri6xt
contact Us::2601 Blair Stone Road Tallahassee FL 92399 Phone,850.487-1824
The State of Florida is.an WEED employer.Cooyrioht 2007-2013 State of Florida.'.:Privacy Statement;:AccessitiPo'twStatement t;.;.Refund.Statemen+.
Under Florida law,email addresses are public records.If you do not want your e-mail address released.in response to a,public-recordsrequest:do not send electroptc
mail to this entity.Instead,contact the office by phone or by traditional mail.It you have arty questions,please contact SSD.487.1395.-pVrsuantto'Section
455.275(1),Florida Statutes,effective October 1,2012,licenseeslicensed under Chapter 455,ES.must provide the Department with an email address if:they have
one.The emails provided.may be.used for official communication with the licensee.However.emaii addresses are publ(c record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455,ES.,
please dick
Product Approval Accepts:
I
Credit Card .
Safe'
i
i
I
I
I l
I
I
i
I
it
htipsa/www.8o6dabuifding.orglprlpr_app dil.aspx?param=wGEVXQwtDgVQEb8FEH60Vrs5wFsWUkbaFo9a3237SSZ56leCsOc92Q%3d"Mcl 3/3
.... ......
3NTERSCR ��EMS
1960 SW 44TH AVE.
e) �1 OCALA.FLORIDA 34474 i
- 'WWV`J.CNJS,CC _..._
8340 PVC
PICTURE WINDOW
IMPACT
o �w.a ci
W zoz arzw
�uryra��m
arm-oa3�
Mit Q
�-a
C� 3 8 5 1 i �t 4 D Qp9� Oz
lIr mg �;rZ'.
r SECTION VIEW 6-BI' o W t�J!a tn w
� O �
o WI.--O aa..
cc
�.
i {Y{l4{YYY{l/�
i�05.
}f--� -i'OVERALL 'r"`f,«.
tNTEEiiOR f 114'TEMPERED g�t t4o 592b4 'gyp
_..._$118'AIRSPACE
;•9 STATE
_rile"LAMI GLASS.
3f18'HEAT STRENGTH �ni'r�SG.A Al�
,.099 SENTRY GLASS iON4PLASTIN7ERLAYGP,
3116`HEAT STRENGTH
r5
IS SPACERURASEAI SIKAFLEX 552 OR
a
_-- PURFECT GLAZE"H". „
9122/2.017
5 112"GLASS 6ITE -P E.
-LUCAS A,TURNEE.
R,P,
58201
Q - 1239 JAFL BARA AVE,
NORTH PORT,
SECTION VIEW A•A avec esc N�inia`:
2 SECTION VIEWS&
GLAZING DETAIL
1;1
DRAWN 8Y; OAT;
ADE 05/105107
SETTING BLOCKS PERF C 2411.3,3.1 CWS-373 C
E; - SHEET
1:1.33 3 OF 6
vvlNDow sYST�Ms
19DO SW 44TH AVE.
OCALA,FLORIDA34474
W W W.CWS.CC
s MAx RYP) -SEE NOTE T. 8300 PVC
PICTUREWINDOW�
- I IMPACT
1 _ I -INSTALLATION 4 Z �S �'z d
9' _ ) I
ANCHOR(TYP.) to W
MAX O.C. zw2 0 Z Mr g w
u- ZWxa~2'3:7;m
O OV CL o'
vcnF-_ar-rna
Q Z'==Ztimy
I 2 O•�� _
Vw2Ou_V
C�d h.OF02
I }�snN
-------------------- --—----�. oo
— —�
_ 2wd o to0wN W
tr
ANCHOR LAYOUT-(FLANGE) x CL LCL X
u
IL F a
4d��cA1y0R@W q�iy,,i
..E Ngo
g0. STATE OF
itP Rl6Rti0�`"'�a��
NOTES:
.'INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION,ANCHOR SPACINGAPPLIES TO ALL.SHAPES(SEE SHEET 2)ALONGALL FRAME EOGES. SILL ANCHOR SPACING SAME AS HEAD,
2.$HIM AS REO AT EACH INSTALLATION ANCHOR USING LOAD SEARING SHIMS.MAX.ALLOWABLE SHIM STACK TO BE 1/4'.USE SHIMS WHERE SPACE GREATER.THAN 1116'IS PRESENT. LOAD BEARING SHIMS SHALL BE y
CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED.
3,ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1.SHEET 6. 9/22/2017
4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIALOR COATING.DISSIMILAR METALS OR MATERIAL$IN CONTACT WITH PRESSURETREATED WOOp MUST LUCAS A.TURNER.P.E.
BE PROTECTED TO PREVENT REACTION, PL PE!t 58201
1239 JABARA AVE.
S.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS.AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS'LESS THANTHE MINIMUM NORTH PORT.FL 34288
SPECIFIED INTABLE1,SHEET 6. PH.941-380-1574
HEET:OC; CRIPTIONr ""-
6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO; FOR GONCRETEICMU OPENINGS;EMBEDMENT SHALL BE BEYOND WOOD BUCKS,If USED,INTO SUBSTRATE.
INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQURE 1X WOOD BUCKS BETWEEN THE PRODUCT AND.SUBSTRATE, ANCHOR SCHEDULE&
W STALLATIONS TO HOLLOW CMU REQUIRE THE USEOF 1XBUCKS BETWEEN THE PRODUCT AND SUBSTRATE, NOTES
7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL.FASTENERS:3•FAR MASONRY,1'FOR WOOD AND METAL. DRAWN 8Y"-- jD4lU:-
ADE I 05/05/07
8.W006 OR MASONRY OPENINGS.BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR.ENGINEEROF RECORD AND INSTALLED TO TRANSFER.:WIND LOADSTOTHE.STRUCTURE,
. owe e:,
SUBSTRATES SHALL.MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN.TABLE1.SHEET 6.CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED,
CWS-373 C
9.SEAUNGAND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE Or INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING TI4E CURRENT VERSION OF THE REfERENCE.DOCUMENTS: CAL C,
FMA)AAMAIOO(FINWINOOWS),FMAIAAMA200(FLANGE.WINDOWS), FMNWDMA260(BOX WINDOWS),FMAIAAMAIWOMA300(EXTERIORDOORS)' SHEET
}
--- 1:20
5OF6
; " •amu. .«:.,. < ..�..... - :, ra,..:.. :.'a .:.�.aarr�:^ r,:+.
^
- -- - - - - - - - -' --- - -- --- - --- - - -' -- -- '
111V STEEL(33 KSI M14) DRILLING SCREW THRU 0.126" SHOWN FOR FLANGe WINDOWS. - 6 or�6]'
U1239 Mara Ave.
j�► North Port,FL 34288
ENGINEERING& Ph. 941-380-1574
CONSULTING, INC. FBPE C.O.A.#29779
Evaluation Report 373C
September 7,2017
Product Description: Series 8300 PVC Fixed Window,Large Missile Impact,48"x 120"unit size 49
114"x 121 1/4"flange size, 1/4 Temp.—air—7/16 Lami HS(3/16-.094SGP-3/16)glass
Manufacturer: Custom Window Systems,Inc. 1900 SW 44`h Ave,Ocala,FL 34474
Statement of Compliance: This report evaluates the above listed product per the requirements of FAC
Product Approval Rule Chapter 61G20=3.005(4). This product complies with the requirements of the 6
Edition(2017)Florida Building Code.including the:High Velocity Hurricane Zone. The product testing
standards performed are outlined below.
Technical Documentation:
j 1) This report,prepared by Lucas A.Turner,P.E.,at 1239 Jabara Ave.,North Port,FL
2) Approval drawing CWS-373C,signed and sealed by Lucas A.Turner,P.E.
3) Test Reports NCTL-210-3591-1,and-IA,from National Certified Testing'Laboratories,Orlando,
FL signed and sealed by Gerard J.Ferrara,P.E.,with testing performed: AAMA/WDMA/CSA
j l Ol/I.S.2/A440-05,ASTM El 886-02/05 and ASTM E1996-02/05,and TAS 201,202,203 1994
4) Supplemental Calculations to support CWS-373C,signed and sealed by Lucas A.Turner,P.E.
i
Installation: Units must be installed according to approval document CWS-373C.
i
Limitations of Use: This product:
• May be used in O configuration in sizes up to 48"x 120"unit size,49 1/4"x 121 1/4"flange size,
j with max.glass daylight size of 45 1/8"x 117 1/8"
• Achieves a design pressure of+70/-70 psf
• Is large missile impact resistant and does not require the use.of shutters
• Maybe used in the High Velocity Hurricane Zone
+ Requires 1/4 Temp. -air—3/16 HS-.090SGP-3/16 HS Iaminated.IG glass minimum
Requires Kuraray(Dupont)SentryGlas Plus Interlayer per Miami-Dade NOA 14-0916.111
• Requires Quanex(Mikron)white rigid PVC framing per Miami-Dade NOA.17-0206.161
t I have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and find
that they comply with the requirements of the 6th Ed.(2017)Florida Building Code for use in this.
product.
Certification of Independence: I do not have,nor do I intend to acquire,nor will I'.acquire,a financial
j interest in Custom Window Systems or in any company manufacturing or distributing products for which
this report is being issued. I do not have, nor do I intend to acquire,nor will I acquire,a financial interest
in any other entity involved in the testing or approval process of this product.
i
std}tirrr�rarrr$��``
4,e P�t'3REagt �,bi
Lucas Turner y»' No 582€1
2017-09-16 * # * 9/07/2017
09:19+20:00 '1 STATE :`AU Lucas A. Turner,P.E.
'.O•. •girt FL PE#58201
0 At•..... • 't �
r�¢dr�•`S,CD1VAr ���4�