HomeMy WebLinkAboutWind Load Calculation RECEIVED JUN 0b 2018 500 SW 12th Ave tTt Lucia county, Permitting SUR IGHT Deerfield Beach, FL 33442 WINDOW S Fax, 561-2 2-356 Fax. 5131-292-3562 Property Information Building Information Owner: BRITTENY&CHARLES BATZ Wind Zone: 170 MPH. Address: 4840 GROVER RD. Exposure Category: C FORT PIERCE,FL 34951 Minimum Building Dimension: 35 ft. Mean Roof Height: 12 ft. JU Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 52 61 7 35.9 -39.1 2 Int 52 61 7 35.9 -39.1 3 Int 36 62 7 36.7 -39.9 4 Int 36 61 7 36.8 40.0 5 Int 36 61 7 36.8 -40.0 _ ......... 6 Int 73 61 7 35.0 -38.2 - . ........... ---._ 7 Int 36 37 7 37.8 -41.0 —_ _... 8 Int 36 61 7 36.8 -40.0 9 Int 52 61 7 35.9 -39.1 FILE Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1 WINDOW& DOOR OPENING INFORmATION 4840 GROVERS ST. BRITTINY & CHALRES BATZ - 6940 A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER (+)pSF (-) PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLIONREQ Y!N SIZE REQ Y/N/NA 1 Int W 7/8"Lami IG 18-0122.12 55 55 35.9 -39.1 1 74x63 52x61 N N 2 Int W 7/8"Lami 1G 18-0122.12 55 55 35.9 -39.1 74x63 52x61 N N 3 Int Window 7,8"LamiIG 18-0122.14 55 55 36.7 -39.9 36x68 36x62 N N 4 Int window 7/8"LamilG 18-0122.14 55 55 36.8 -40.0 36x68 36x61 N N 5 Int window 7/8"LamilG 18-0122.14 55 55 36.8 -40.0 36x68 36x61 N N 6 Int W 7/8"LamilG 18-0122.12 55 55 35.0 -38.2 74x63 73x61 N N 7 Int window 7/8"Lami 16 18-0122.14 55 55 37.8 -41.0 36x68 3607 N N 8 Int window 7/8"LamilG 18-0122.14 55 55 36.8 -40.0 36x68 36x61 N N 9 Int W 7/8"LamilG 18-0122.12 55 55 35.9 -39.1 74x63 52x61 N N 15 O a H C U z u cn