HomeMy WebLinkAboutWind Load Calculation RECEIVED
JUN 0b 2018
500 SW 12th Ave tTt Lucia county, Permitting
SUR IGHT Deerfield Beach, FL 33442
WINDOW S Fax, 561-2 2-356
Fax. 5131-292-3562
Property Information Building Information
Owner: BRITTENY&CHARLES BATZ Wind Zone: 170 MPH.
Address: 4840 GROVER RD. Exposure Category: C
FORT PIERCE,FL 34951 Minimum Building Dimension: 35 ft.
Mean Roof Height: 12 ft.
JU Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 52 61 7 35.9 -39.1
2 Int 52 61 7 35.9 -39.1
3 Int 36 62 7 36.7 -39.9
4 Int 36 61 7 36.8 40.0
5 Int 36 61 7 36.8 -40.0
_ .........
6 Int 73 61 7 35.0 -38.2
- . ........... ---._
7 Int 36 37 7 37.8 -41.0
—_ _...
8 Int 36 61 7 36.8 -40.0
9 Int 52 61 7 35.9 -39.1
FILE
Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1
WINDOW& DOOR OPENING INFORmATION
4840 GROVERS ST. BRITTINY & CHALRES BATZ - 6940
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR TYPE NUMBER (+)pSF (-) PSF (+)PSF (-)PSF TESTED DIMENSIONS MULLIONREQ Y!N
SIZE REQ Y/N/NA
1 Int W 7/8"Lami IG 18-0122.12 55 55 35.9 -39.1 1 74x63 52x61 N N
2 Int W 7/8"Lami 1G 18-0122.12 55 55 35.9 -39.1 74x63 52x61 N N
3 Int Window 7,8"LamiIG 18-0122.14 55 55 36.7 -39.9 36x68 36x62 N N
4 Int window 7/8"LamilG 18-0122.14 55 55 36.8 -40.0 36x68 36x61 N N
5 Int window 7/8"LamilG 18-0122.14 55 55 36.8 -40.0 36x68 36x61 N N
6 Int W 7/8"LamilG 18-0122.12 55 55 35.0 -38.2 74x63 73x61 N N
7 Int window 7/8"Lami 16 18-0122.14 55 55 37.8 -41.0 36x68 3607 N N
8 Int window 7/8"LamilG 18-0122.14 55 55 36.8 -40.0 36x68 36x61 N N
9 Int W 7/8"LamilG 18-0122.12 55 55 35.9 -39.1 74x63 52x61 N N
15
O a
H C
U z u
cn