Loading...
HomeMy WebLinkAboutProduct Approval (2) �1 Business ♦• Professional � .-. SCIS Home �. Log In j User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Unks I Search rich Product Approval s USER:Public User Product Aooroval Menu>Product or Apolication Search>Application Lis[>Application Detail • FL# FL14803-R4 Application Type Revision Code Version 2017 Application Status Approved =County, Comments JUN Archived Product Manufacturer DLP INDUSTRIES,INC. Address/Phone/Email 2125 SW 60 WAY HOLLYWOOD, FL 33023 (800) 243-7373 DLPINDUSTRIES@AOL.COM Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Brian Phipps Address/Phone/Email 2125 SW 60 Way HOLLYWOOD, FL 33023 (800)243-7373 DLPINDUSTRIES@AOL.COM Quality Assurance Representative Address/Phone/Email ixCategory Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 U. Validated By Ryan]. King, P.E. f Validation Checklist-Hardcopy Received Certificate of Independence FL14803 R4 COI (a)Certificate of Independence.pdf Referenced Standard and Year(of Standard) Standard Year ASTM E1886 2005 ASTM E1996 2006 ASTM E1996 2009 ASTM E330 2002 ASTM E331 2000 TAS 201,202, 203 1994 Equivalence of Product Standards Certified By additional use limitations, installation instructions and product j particulars. 1 ' 14803.6 f.WINDSERT WINDSERT'"an operational window insert utilizing a 6'8 i Plastrpo"Impact"Outswing Double Door with or without Sidelites-available configurations(XX or OXXO) Umits of Use Installation Instructions Approved for use in HVHZ: Yes FL14803 R4 II )Inst 14803.6.12df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: See INST 14803.6 for Design Pressure Ratings,any FL14803 R4 AE (�) Eval 14803.6.Ddf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 14803.7g.WIN WINDSE TTM an operationa`iw`iMdQW insert utilizing a 6'8 Plastrpo"Impact"Outswing Single r-available configurations(X) Umits of Use Installation Instructions Approved for use in HVHZ: No FL14803 R4 II ( Inst 14803.7.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Sch P.E. 43409 Impact Resistant: Yes Created by Inde Third Party: Yes Design Pressure: N/A Eva eports Other: See INST 14803.7 for Design Pressure Ratings, 14803 R4 AE (p) Eval 14803.7.pdf additional use limitations, installation inst product Created by Independent Third Party: Yes 14803.8 h. WINDSERT WINDSERT'"an operational window insert utilizing a 6'8 Plastrpo"Impact"Outswing Single Door with Sidelites- avallable configurations(XO or OX and OXO) Limits of Use Installation Instructions Approved for use in HVHZ: No FL14803 R4 II (4) Inst 14803.8.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 14803.8 for Design Pressure Ratings, any FL14803 R4 AE (aUval 14803.8.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes j particulars. 14803.9 i.WINDSERT WINDSERT""an operational window insert utilizing a 6'8 Plastrpo"Impact'Outswing Double Door with or without Sidelites-available configurations(XX or OXXO) j Umits of Use Installation Instructions Approved for use in HVHZ: No FL14803 R4 II ( Inst 14803.9.Odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 14803.9 for Design Pressure Ratings,any FL14803 R4 AE (a) Eval 14803.9.odf I additional use limitations, installation instructions and product Created by Independent Third Party: Yes i particulars. 0 Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Qh yrigh[2007-2013 State of Florida.::Privacy Statement::Accessibility,Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The&mails provided may be used for official communication with the licensee.However email addresses are public record-If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please dick here. Product Approval Accept: ® ® Credit Card Safe 4 !VIvllt �•' •.,- DLP INDUSTRIES INC 37.5"MAX.OVERALL _ _ ".� ' z '• GJ a O" FRAME WIDTH •.... y` 2125 SW 60 WAY .,����''Irl ````�� o o m Z HOLLYWOOD, FL 33023 Z U \\VI'\\ `o Eo Omcw WINDSERTTM e a o as a a moat E0 0 Operational Window Insert aZ o w � o — Utilizing O w Z� A Fiberglass Door Panel o wZ OUTSWING ZW IMPACT" w GENERAL NOTES o a N X 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida ` a a a Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone" w (HVHZ). 'm 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to Nbase material shall be beyond wall dressing or stucco. 0 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2&R301.2.1.2 and does not require an impact resistant covering.This z product meets missile level"D"and includes Wind Zone 4 as defined in ASTM El 996 and d g $ FBC W L --_ of C4. For 2x stud cons ruc io , ese units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of this drawing require further ? engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS m SHEET# DESCRIPTION 1 Typical elevation,design pressures,&general notes o 0 Z U f 2 Door panel details MAX.FRAME MAX' DESIGN PRESSURE(PSF) a+Tc_ 9/14 15 3 Lite frame details and glazing details DIMENSION D.L.O. scuE: N.T.S. 4 Horizontal cross sections DIMENSION POSITIVE NEGATIVE DWG.sf: JK m' 5 Vertical cross sections CHK.B1: LFS 3 8 Buck and frame anchoring 37.5'x 81.13" 20"x 29.13" +60.0 65.0 DRAWING NO.: a 0 7 Bill of materials and components FL-14803.7 n NOTE:See Sheet 2 for Hardware Design Pressure Limitations SHEET 1 or 7 0.7' 2.8" �� ...........* 7777�i G1 EXTERIOR TOP RAIL � 0.4' 0'4" TY (COMP.) = n _ � – �• tin '• . n SEE NOTE 1 V% &': � a n 25 ii�777 * ````�� _ cD e 711111 ll� .:z CAP ( ! U N C P CAP(PVC) CAP(PVC) LATCH STILE(LVL) m Go. v HINGE STILE(LVL) INTERIOR 25 g r o 9 25 a N r o L a SEE NOTE 2 SEE NOTE 2 "} m a o IL 14 �Z 9 HORIZONTAL CROSS SECTION a 8 2 SASH LOCK J d 35.75-MAX PANEL WIDTH ~ 12 23 d G1 W p:o 2 INTERIOR EXTERIOR =I o i o � o � 2! a g O � / c ; 12 L = 1 / "' n w 2 0 En HARDWARE TABLE z MANUFACTURER MODEL MAX.DESIGN 60 F8 PRESSURE6 7S KNOB: KWIKSETSERIES TABLE KWIKSEf DEADBOLT: KWIKSET SERIES(660) +50/-55 PSF :•.. LEVER: YH COLLECTION •`' 25 YALE DEADBOLT: NEW TRADWNS(800 SERIES) +50/-55 PSF �.. SEE NOTE 1 W � SEE HARDWARE FIBERGLASS SKIN LKNOB: F-SERIES •' z TABLE SCHLAGE +50/-55 PSF (0.075'MIN.THK.) 9 m a BOLT: B60/62 FOAM COREYALE : YN COLLECTION +60/-65 PSF (POLYURETHANE- –zDLP LITE FRAME BOLT: YH 83 = D n 1.9 PCF MIN.) wre 9/14/15 0 INDSER NOTES: SCALL N.T.S. I� 1.SMS Screw spacing at head and dl: BOTTOM RAIL-- Dm BY: JK m DOOR PANEL 5'from each end 8 one at centerline(3 total). (COMP.) c,eY: LFS 40 Plastpro 2.SMS Screw spacing at jambs: x NM: rc 5"from each end&spaced @ B-11"o.c.(7 total). 2 VERTICAL CROSS SEC71ON NAMNAM o 2 s— 2 ov 7 p 0 62 R.10ients\OLP Industries PERMANENTVs-Florida Product ApWvwiIs\FL-14803 Ext Doors-Swinging Exterior Door Assemhlies\C-Drawings\FL-14803 6TH ED(2017)\FL-14803.7-9.dwg,3.4 65.5 MAX PANEL HEIGHT 29.13•MAX D.LO.HEIGHT v O� cT ZO ^ x w in L, m1 M p m o T P 2.1• °S S z �— 1 19• D �zn �zn T y --� �o.3rg m m L =A 1.75�-I 1.91• w L 2.49• w p 1.64 I Lw C �� o ap 0o D I � I----�0.4• STII 0.6• t1r F� p o.s• M w 0.95 0.94' x 0.69• 1.9' 0.44• w 1 1 Ur _ Ca torr C N N 0.07• x (y 0.061• N n rn Vj f"i L�2.W' 'A227 F---►�0.89' W o TF 1.16' C 1.1 1 o 3 0.78• w V 0.29• e. Lit > w 2.15 1.or w N 1n � z c T s ----- -- --------� n a 0 O Z w .......... SC.... w No.43409 M gN'7"s Nr PRODUCT: Do .rft Pmpamd lii'•�i ••. �� Lyndon F. Schmidt ��� •••• ��••'• �� OLP WINDSERT P/.E� No. fo y A PART OR ASSEMBLY: /� BUILDING CONSULTANTS. INC. �1 to 1 8 16 17 UPDATE TD 87H ED. (2017 fBC JK J l•�P.O. Ebx 230. Volrico, R 33393 I`i U NO DATE BY LITE FRAME DETAILS Phone No.: 813.659.9197 REVISIONS AND GLAZING DETAILS FBPE CA No. 9813 0 2015 R.W.BUILOINn CON-TANTe INC. R:\Clens\DLP Indust Hm PERMANENAA-Pkxida PMdutt Approvals\FL-14803 Ext Doors-Swk19n9 Exterior Door As rriblles\C-Drawkgs\FL-14803 6TH ED(2017)1FL-14803.7-9.dw9,4.4 m� �A z • °� o m o r A� W x0 n N r �C2o a m m Zm $ m t7t W O N O O QD Q A W a X � -I o z z O V A �O V N �a � o m = In � a N . v • v ° ° ° m O O O z'! _Z H D v O In N N nm O W Z v v v \111111111/1/I Q 3 =y N°43409 ' Q PRODUCT: Document.Prepared 87'1, 3 toWIND P P.E. No 43409 Lyndon F. idt '�����''; ►nn11 o PART OR ASSEMBLY: ��/BUILDING CONSULTANTS, INC. IW V1 1 -171-171-7 UPDATE TO 6TH ED, 2017 FBC JK YV P.O. Box 230, Volrico, FL 33595 v 14 y U NO DATE gY HORIZONTAL CROSS SECTIONS phone No.: 813.659.9197 REMSIONS FSPE C.A. No. 9813 02015 R.W.19UILDING CDNBULTANTB INC. R:1C31ents\DLP Industries PERMANENT\A-FlorWe Product ApproveMR-14803 Ext Doors-SwVOV Exterior Door Aq e- \C-Drtwtgs\FL-14803 6TH ED(2017)\FL-19803.7-94w9,5.4 V v v p m n O $ T ° v • •p 7n e O P, ' N . V ° Z O ° X p ° v N 0.15 .v C'SINK (TYP-) m 1-114'MIN. EMB.(TYP.) N w m X p 0 T1 ° e D v r n 0 Hp a N ° T > O T Z z O Zm7 N N mx m y • D n eD X" �n cyaO T ' 1-1/4"MIN. EMB.(TYP.) 2 r m � O D fif Ds 71-1/4MIN. EMB.(TYP.) ``tttt\111111/T�// No.49409 6p PRODUCT: Doeunwrfa 61�i F� ly Lyntlon F. Saw to OLP P.E. No. 43409 //0,,�� to WINVISERT m q�F'�rvALtttt� r— •.Zi PART OR ASSEMBLY: Y" P.O. BUILDING CONSULTANTS, INC. It.I x in t —8/-16T17 UPDATE TO 8fH m. 2017 FOC VERTICAL CROSS SECTIONS YV Box 230• vol Moo, FL 33595 V v NO DATE BY Phone No.: 613.659.9197 REMSIONS FSPE CA No. 9613 ' O 201 5 R.W.BUILDING CONSULTANTS INC. o`%``` � � _ � 'v SEE HINGE L 2X BUCK JJrrrIIl I r1 � `°i D TYP.HEAD DETAIL \ Z o z°v _ $JAMBS _ e6 (TYP•) G 1X BUCK ((j L j A c°w TYP. EAD " 00. 0 Vl Ot4 MASONRY7 b, MASONRY JAMB y r m d a OPENING OPENING of F � cal R '14 FRAME j U 2X BUCK-,,, _ o 2X BUCK o o w a Ci � o U ( p m a m OKK ANCHORING STRIKE JAMB FRAME ANCHORING HINGE JAMA 8 0 CONCREIEANCHORNOTEs: . I.Concrete anchor locattons at the comers may be odJusted to maintain the min. 12 edge&*nce to mortar joints. 2 Concrete anchor ted as AMAX.ON CENTER"must be i mainldn .edge dstance to mortar joints,odd brd concrete anchors may be to ensue the"MAX.ON CENTER"dmenslon are not exceeded. m 3.c anchortoble: 28 H 1X BUCK 1X BUCK H 9 _ IN.CLEARANCE MIN.CIEA O CHOR ANCHOR SB 2X BUCK 2X BUC m TYPE SRE BEDMEM TO MASONRY TO ADJACENT 2X BUfH , EDGE :ANCHOR z u 1X BU 2X BUCK DAw-- 9/14/15 o ElCO 1/4" 1.1/P 1" 4" 27 N.T.S. ° uttRAcoN H 1X BUCK DWG.BY: JK m LFS W TAPCO `" 1/4" r 1.1/2' QW.ov.. DW*W NO.: WOOD SCREW INSTALLATION NOTES: LATCH B DEADBOLi DETAIL HINGE DETAIL FL-14803.7 1.Mointaln o ff**num S/8"edge dxtonce,rend "o.c.spacing of a wood screws to prevent the spiffM of wood. Outswi"9 MM of 7 ^ 0 BILL OF MATERIALS rmm# DESCwrm MATEMAL 4 •'•, /'� A 1X BUCK SG>=0.55 WOOD =z n B 2X BUCK SG>=0.55 WOOD .( ti = i C 1/4'MAX.SHIM SPACE 4.SG~I c Nt D 114'X 2-314"ELCO OR ITW CONCRETE SCREW STEEL ' \ t a�' MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK N E CONFORMING TO ASTM C90 CONCRETE ����INI* ``�� z 6 G 1/4-X 3-3/4'PFH ELCO OR ITW CONCRETE SCREW STEEL °a H 3/16'x 3-1/4'PFH ELCO OR ITW CONCRETE SCREW STEEL �- —2.44•�---2.13• .\ E i Z v If, v o 1 114'X 3-1/4'PFH ELCO OR ITW CONCRETE SCREW STEEL POLY FIBER JAMB 4.58' '�' N " m'a a L #8 X 2-1/2'PFH WOOD SCREW(1.15-MIN.EMB.) STEEL 1 o 1 POLY FIBER JAMB COMP./VINYL = iz 2 FINGER JOINTED PINE FRAME WOOD v° @ 7 WEATHERSTRIP FOAMSd 8 9 4'X 4'BUTT HINGE STEEL 11 #9 X 314'PFH WOOD SCREW STEEL 12 BULB VINYL WEATHERSTRIP VINYL 25 #12 X 1"PFH SELF DRILLING SMS STEEL 4 WOOD JAMB 27LATCH STRIKE PLATE STEEL 28 DEADBOLT STRIKE PLATE(SECURITY) STEEL REACH °-�"> o 30 OUTSWING THRESHOLD ALUMIWOOD m '� 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 18 58 #8 X 2'PFH WS STEEL o m 60 SECURITY SCREEN(ALUM 6063-T6)-OPTIONAL ALUM/SS ggI 0.5' iC a 7 WE4WERSTRIP Y Endura Face 5 8 tr P 4.55' .^ 2" STARLET'S STEEL MESH: � z 0.035'0 t 0.0005 n o 10x10 10.5 STRANDS PE3t RICH tl m I z WE' 9/14/15 i N.T.S. 9 SECURITY M.BY:160 OUTSWING THRESHOLD ALUM(8053 TB) 30 DLP(DOSR) cNpc.rn: LFS DROW NO.: FL-14803.7 "- a mcr ZOFL o a