Loading...
HomeMy WebLinkAboutProduct Approval (2) 1/4/2018 Florida Building Code Online v>+ - MORIDA,011PARTMI]INT OF =�` 11 :. - - -' -- BCIS Home Login I User Reglstrdtion I Hot Topics I Submit Surcharge I Stats&Facts I Publications I FBC Staff I BCIS Site Map Links Search Florida a Product Approval r USER:Public User RECEIVED 6uF�F Product Approval Menu>Product or Application Search>Application List>Application Detail JUN 11 2018 • • FL# FL16177-R2 Application Type Revision ST. Lucie County, Permitting Code Version 2017 Application Status Approved Comments Archived ❑ I.LE CO P- Y Product Manufacturer Custom Window Sys ms I Address/Phone/Email 1900 SW 44th Avenue Ocala,FL 34474 (352)368-6922 Ext 245 kpine@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Quality Assurance Representative Arturo Monteverde Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext 221 amonteverde@cws.cc Category (ED Subcategory Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Lucas A.Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 07/21/2020 Validated By Steven M. Urich,PE W Validation Checklist-Hardcopy Received Certificate of Independence FL16177 R2 COI EvalReoort812C.12df Referenced Standard and Year(of Standard) ;Standard Year AAMA/WDMA/CSA/101/I.S.2/A440-08 2008 ASTM E1886-05 2005 ASTM E1996-09 2009 PA TAS 201/202/203 1994 Equivalence of Product Standards Certified By hftps://www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvyf4ngAXh1oy8QtjDbmBlPrafAGHlxlsgtjUObEAbzoQ%3d%3d 1/2 1/4/2018 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 09/28/2017 Date Validated 09/29/2017 Date Pending FBC Approval 10/03/2017 Date Approved 12/12/2017 Summary of Products CFL# Model,Number or Name Description 16177.1 SH-8100 PVC Single Hung SH-8100 PVC Single Hung Impact Resistant window. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16177 R2 II CWS-812C.pdf Approved for use outside HVHZ:Yes Verified By: Lucas A.Turner 58201 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:+70/-70 Evaluation Reports Other:SH-8100 PVC Impact,no sill anchors required.Safety FL16177 R2 AE EvalReport812C.pdf glazing required on outer lite above 30 ft. in HVHZ. Glass Created by Independent Third Party:Yes complies to ASTM E1300-04. Back INext Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click herr.. Product Approval Accepts: ®'-^- WE eChecY. M Credit Car.j Safe https://w m.floddabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgvyf4ngAXh10y8QtjDbmBiPrafAGHlxlsggUObEAbzoQ%3d*/o3d 2/2 URNER 1239 Jabara Ave. North Port,FL 34288 ENGINEERING & Ph. 941-380-1574 TCONSULTING, INC. FBPE C.O.A. #29779 Evaluation Report 812C August 29,2017 Product Description: Series 8100 PVC Single Hung,Large Missile Impact, 517/8"x 613/4"unit size, +/-70 PSF,no anchors in sill Manufacturer: Custom Window Systems, Inc. 1900 SW 44 h Ave, Ocala,FL 34474 Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 6`h Edition(2017)Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report,prepared by Lucas A. Turner,P.E.,at 1239 Jabara Ave.,North Port,FL 2) Approval drawing CWS-812C, signed and sealed by Lucas A.Turner,P.E. 3) Test Report NCTL-210-3815-1A, -2,and-2A,by National Certified Testing Laboratories, Orlando,FL, signed and sealed by Gerard J.Ferrara,with testing performed: TAS 201/202/203- 94,ASTM E 1886-02/04/05, 1996-02/04/06/09,and AAMA/WDMA/CSA 101/I.S.2/A440-08 4) Supplemental Calculations to support CWS-812C, signed and sealed by Lucas A. Turner,P.E. Installation: Units must be installed according to approval document CWS-812C. Limitations of Use: This product: • May be used in O/X configuration in sizes and with max. glass DLO heights as shown in CWS- 812C • Is impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires 7/8"Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite(Tempered required above 30 ft in HVHZ) —Air—5/16 Laminated(1/8Ann-.090PVB-1/8Ann)inboard lite • Requires Kuraray(Dupont)PVB Interlayer per Miami-Dade N.O.A. 16-1117.021 • Requires Quanex(Mikron)white rigid PVC framing per Miami-Dade N.O.A. 17-0206.101 1 I have evaluated the materials in these NOAs and find that they comply with the requirements of the 6''Ed. (2017)Florida Building Code for use in this product. Certification of Independence: I do not have,nor do I intend to acquire,nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have,nor do I intend to acquire,nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. 04%J11150j%r �1�? t1OREb ��ir Lucas No 58201 1. � `'; .. Turner 2017-08-30 STATE OF: 16:11+20:00 $�,t;•,,,c •'��,.• c. 8/29/2017 '�, '•`��,� pC?��'� Lucas A. Turner, P.E. FL PE#58201 SINGLE HUNG - LARGE MISSILE IMPACT GENERAL NOTES: o,_-,9®m,W 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED WINDOW SYSTEMS I�/ IIJ% TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ)AND 1900 SW 44TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA,FLORIDA 34474 IN ASTM E 1996 PER THE FBC. W WW.CWS.CC 2.GLAZING OPTIONS:(SEE SHEET 2) 531/8"MAX.OVERALL FLANGE WIDTH 3.CONFIGURATIONS:'01X". 8100 PVC 517/8"MAX.UNIT WIDTH SINGLE HUNG 4.DESIGN PRESSURE RATING: IMPACT 4711/16"GLASS DLO -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. A -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER Z_ Q 3 INFILTRATION TEST PRESSURE AND GLASS TABLESw rn w O O d -- -- -- ASTM E-1300.04e01/09. z w_j 0 a k 2 w Lu z0? Ce--t 63" _ __ __ I _ 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED LL I-Q„W Z O 3�2 MAX IN THE DESIGN OF THIS PRODUCT.SEE SHEET 6 FOR ANCHOR z z=m = OVERALL I I DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD O O I--O�-�F N a FLANGE ANCHOR CALCULATIONS. p z z z l-=v� HEIGHT O z O 5 -7 U- B I B 2613/16' 6.PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE ¢ H z LL�p O I+-Z GLASS NOT REQUIRED. >w <a3a O w 9 m O- DLO Q d'2�>7�0. I I I 7.ALL FRAMES AND VENTS FULLY WELDED.SMALL JOINT SEAM SEALANT w On o:CO O w U)w 61 314' I I USED AT FIXED MEETING RAIL AND JAMB. R LL z�wa O-I V)F UN OwH-0 w = HEIGHT 8.SERIES/MODEL DESIGNATION SH-8100. w = CL D. I- d 9.THE DESIGNATION X AND O STAND FOR THE FOLLOWING: I I X=OPERABLE SASH,O=FDD SASH ``��y PNC RE W 3303/3/ ,, .16' I I 2fi 7/8" 10.SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR Al V'V2 � SF'•py�.� `, GLASS LOCATION. No 58201 "•�� H IGHT Y DLO p*. ..k, g 11.EXTERNAL WEEP SLOT=1/4"x 1-1/4"LOCATED 4"FROM BOTH ENDS. iY - 6 Q: STATE OF ;�4!` I q�SS�ONA�EN+`'� LucasTurne A r 6r 451/16" 2017-09-22 GLASS DLO 13:36-04:00 48 3/8' 9/22/2017 MAX.SASH WIDTH LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCR&TION: GENERAL NOTES AND TABLE OF CONTENTS ELEVATIONS DRAWN BY: DATE: GENERAL NOTES&ELEVATIONS.....1 DESIGN PRESSURE BAT 06/18/12 GLAZING DETAIL.................................2 MAX. UNIT SIZE IMPACT RATING DWG#: REV.: SECTION VIEWS.................................3 RATING EXTRUSIONS&B.O.M........................4 CWS-812 c ANCHOR SCHEDULE&NOTES.........5 51-7/8"x 61-3/4" +/-70 PSF LARGE MISSILE IMPACT SCALE: INSTALLATION DETAILS....................6 SHEET 1:15 1 OF 6 aalbm.m WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CW S.CC 8100 PVC SINGLE HUNG IMPACT a z 3 az3 nwoawca Z wJ0rui w ZOZ w-?F_ 0 Qm�>-O=gym LL I-wzl-3:2x 7/8'OVERALL INSULATED GLASS 7/8'OVERALL INSULATED GLASS O O F=-O Q Q xw O C) 1/8'ANNEALED OR TEMPERED 1/8'ANNEALED OR TEMPERED O O O j Z D'~ a Z p =--OnU- 7/16"AIRSPACE 7/16'AIRSPACE Q F? M Q O LLZ >Q- ¢30w-20_ 5/16"LAMINATED GLASS 5/16'LAMINATED GLASS 0 y}0 ZO 1/8'ANNEALED 1/8'ANNEALED w LL U)W to p w(D F .090"PVB INTERLAYER BY DUPONT .090"PVB INTERLAYER BY DUPONT w~0 w= 1/ B'ANNEALED 1/8"ANNEALED a D a QUANEX DURASEAL QUANEX DURASEAL 1116tusoll" IG SPACER IG SPACER `%%% gORELV 47 PURFECT GLAZE"H"OR SIKAFLEX 552 4 PURFECT GLAZE"H"OR SIKAFLEX 552 r t No 58201 %'�9 14 1/2'GLASS BRE 144) 1/2'GLASS BITE * _ ' 48 148 S13'. s5 'a STATE OF : = 3 .A .. ..... 1 1 �NA� 0 SASH LITE FIXED LITE 9/22/2017 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRPTK)N: GLAZING DETAILS DRAWN BY: DATE: BAT 06/18/12 DWG#: REV.: CWS-812 C SETTING BLOCKS PER FBC 2411.3.3.1 11E: SHEET 1:1 2 OF 6 INTERIOR Qeimffl 1900 SW 44TH AVE. OCALA,FLORIDA 34474 www.cws.cc 45 3 53 12 38 13 32 3 4 45 8100 PVC 0 Or SINGLE HUNG IMPACT zZ w-jo aW❑Wg R0§i .0W14 Z Z 2 m a W O_ 3 14 54 14 65 66 63 19 4 O O F-O a W 0 0 SECTION B-B O 0 0)z-K 9LL -y a ❑ ZV, Q z=)U- NOTE:LEFT SIDE SHOWS FU(ED SECTION VIEW, a LL M p O LL Z RIGHT SIDE SHOWS SASH SECTION VIEW. 3 O F-C Z- W OnwmIS w O)w LL u)W QJfnH 14 39 O WF=-O a=w� a0 a ~ a a:3r w 'L 7 8 ,t►1suuop4j 1 9 INTERIOR `�G ,PN��S 48 v: No 58201 -A,% 62 62 X90: STATE OF ItU % C,R� 14 53 lot 65 10 66 6 3 3 [� 3 9/22/2017 18 11 6 LUCAS A.TURNER,P.E. 2 4 FL PE#58201 3 1239 JABARA AVE. 30 NORTH PORT,FL 34288 D PH.941-380-1574 SHEET DESCRIPTION: 0 SECTION A A SECTION VIEWS DRAWN BY: DATE: BAT 06/18/12 DWG REV.: NOTE: ITEMS NOT SHOWN FOR CLARITY: CWS-812 C 20,25-26,36-37,44,51-52,55-56,64,67-68 SCALE: SHEET 1:2 3OF6 PARTS LIST FRAME CORNER /ii1 )�//I1�j . ITEM PAFR# DESCRIPTION VENDOR MATERIAL 31/6• CONSTRUCTION �(��/tn41R�vL�l4l�L/1!(Y 1 H-6031 Warn'Fr.,SH,w/Fig.,PVC,Head Mikron Vinyl WINDOW SYSTEMS 2 H-6031 Main Fr.,SH,w/Fig.,PVC,Sill Mikron Vinyl 1 1 15116' 23/1 1900 SW 44TH AVE. 3 H-6031 Main Fr.,SH,w/Fig.,PVC,L.Jb. Mikron Vinyl 2 OCALA,FLORIDA 34474 4 H-6031 Main Fr.,SH,w/Fig.,PVC,R.Jb. Mikron Vinyl 3 rEIL 6 WWW.CWS.CC 6 S-1577 Impact Hook Keymark Alum 4 10 8 H 8027 Sash Meet.Rail,PVC Mikron Vinyl 211/16^ 1518" r 1� 1 5/B" 9 H-1497 Reinf.Sash Meet.Rail Keymark Alum 1/16' I LI t/16° 8100 PVC 10 H-6028 Sash Bottom Rail,PVC Mikron Vinyl t� L l) 1/16' CORNER WELD L (ALL SIDES) SINGLE HUNG 12 H30D4 Sash Sidefrop/Bot.Rail Mikron Vinyl 0 1:8 13 S-1498 Reinf.S.B.R./S.S.R IMPACT 14 S-6064 Glz.Bd.,7/8" Mikron Vinyl PVC FRAME FLANGE-6031 PVC SASH BTM.RAIL-6028 PVC SASH TOP RAIL-6027 18 S-6013 Scm.Adapt.,w/Nib,PVC,Horiz. Mikron Vinyl ¢ Z 3 <z 3 19 S-6014 Scm.Adapt.,PVC,Vert. Mikron Vinyl 1 1/2• F- ❑w O <w a p LU 20 S-6029 Sash Stop/Filler,PVC,Vert. Mikron Vinyl 1 3/16° 37 w z O Z W=Z C 23 1 H-1699 lReinfbrcement,SBR Keymark Alum 718°6 Q <O�>-O WLL m 24 P-2190 Balance BSI Z z x 2< W O O 25 P3059 Sash Cam,PVC BSI Plastic 3 O O F O r*a H w FIXED MEETING RAIL p Z-�-Z Fx, CL 26 P3046 Take Out Clip BSI SS 1116° 1�8• 2 1/8° 1/16° SCREWED TOGETHER WITH z _0(9=1 Z-55- 27 ~ P-3783 Lock,Impact,PVC Interlock 1/16• OUTERFRAME < Z U to Z O w U F -'`o Z 28 P-4069 Keeper,Impact,PVC Interlock 2amacH 1:8 > <3:0w-=0_ REINF.,IMPACT HOOK-1112 I-U C Z uj 30 P-3215 Weep Cover w/Flap Geer Plastic 0 }O O g 32 P-3429 Wstp.,0.270 x.187 back FinSeal,Gray Ultrafab PVC SASH SIDE RAIL-6004 FIXED RAIL-1836w LL y w in aO J N F 37 P-4638 #8 x 2-1/2 PH Mod.Truss,Type A,TEK 2 Fastenal Steel a ?=a W O-rq 38 P-3768 #8 x 0.625 Ph PH SMS Hub City Steel 1 5/16• 9�16^ O z~� w=_ 39 P-4051W#8 x 1.250 Ph FH TER,Wht. Hub City Steel 112" 1 1/8"F11 1 1/e•y a F a. ��'nw. 40 P-4264W#8 x 3/4 FH PH w/#6 Head,TEK,Wht. Hub City Steel 0 I 5/16• µuua, 44 P3342 Seem Sealer,SM-5504 Schnee y 7/8L 1/16' 1 5/16" 045• ���Q?,PNpENS'•rGQ��i, 45 P3752 Ca Plug,1/2"Hole M&M Nylon 47 P-3438 Sikaflex 552 or Purfect Glaze"H" Sika/Henkel 1/16" JG.' F •,2��� 48 P3352 Set.Blk.,85 Dur.,1/8"x 5/8"x 2"Lg. F.Lowe Rubber PVC SASH STOP-6025 PVC SCREEN CATCH-6013 PVC FIXED RAIL COVER-6063 PVC SCREEN SUPPORT-6014 Z-: No 58201 S 10 51 1 P-3881 ITemporary Lbl.(NFRC/DP) "*: * %* 52 P3613 CWS Lbl.(logo) Pro LabelQ ea. 53 Sash SEE SHEET 2 GLASS 314"—} y 3/4" 1l t- . STATE of :ski' 54 Fixed SEE SHEET 2 GLASS 3/16•TI� �—/� 3 � 9 �I 14 ��:��(•S•'; 56 P3281 Spacer Duraseal T 13 15/16• IIrJ 1/16° '` 1/16 7/8' 62 P3218 Screen Frame,Horiz. Allmetal Alum 1/1s L 63 P3218 Screen Frame,Vert. Allmetal I Alum REINF.S.B.RJS.S.R.-1498 REINF. BTM RAIL-1699 REINF.TOP RAIL-1497 PVC GLAZING BEAD-6064 64 P3321 Screen Frame Comer Key Allmetal Plastic 65 1 P-3581 IScreen Cloth,18 x 16 Fiberglass Bettervue Fiberglass 66 P3228 Screen Spline,.155 Dia.,Blk. Dapa Vinyl 7 67 P-3029 Screen Pull Tab Summit Alum 9/22/2017 68 P3033 Screen Spring,SS Fl.Screen SS 70 P3113 Screw Support for PVC T.Plastics Nylon LUCAS A.TURNER,P.E. 71 H-1836 Alum.Fixed Rail Keymark Alum 0 3/16• FL PE#58201 72 8-6063 Cover,Fixed Rail Mikron Vinyl O 1239 JABARA AVE. 73 S-1112 Reinforcement,Impact Hook Keymark Alum NORTH PORT, 34288 74 35 P- 41 #8 x 1/2",Pan Head,TEK Fastenal Steel PH.94 11 574 15/16"- 112' SHEET DESCRIPTION:TION:-TON: LINE ITEMS NOT USED: 5" 3/16'^ 5,7,11,15-17,21-22,29,31,33-36,41-43,46,49-50,55,57-61,69 6 1 3°� BOM AND EXTRUSIONS 7//' 1/16" r� D T_ SCREW SUPPORT-3113 DRAWN BY: DATE: IMPACT HOOK BAT 06/18/12 S-1577 DWG#: REV.: CWS-812 C NOTE:ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. SCALE: SHEET 1:2 4OF6 a0go" 6"MAX.(TYP.) 17"MAX.O.C.(TYP.) WINDOW SYSTEMS 1900 SW 44TH AVE. 6"MAX.(TYP.) OCALA,FLORIDA 34474 -- -- -- WWW.CWS.CC SEE NOTE 2 101/2" , , 8100 PVC MAX O.C. SINGLE HUNG O INSTALLATION IMPACT ANCHOR(TYP.) I I Q ? 0 CDW O OO I I z WJak�W w zOz W—?t "--� f-w z�32x MToRAL z II X II z=2}aWFw00v a 4'(NP') 052 za z0UiVwZ LL = Q Fz �ZOLL <30FO=OZ 10 T Z Q Opl-}5i�m MAX O.C. W LLu2wco0-jvif- (TYP.) a =D. w O 0 Lu D. ILL, tu. 4"(TYP. -- -- -- ,��,`�PNOREW,TG�'.. .GP.��CEN's 50, 4"(TYP.) NO ANCHORS REQUIRED IN SILLv:• No 58201 •"L ANCHOR LAYOUT-(FLANGE) ^fl= c a '9Qt STATE OF :�W� NOTES: *011 NAI 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.NO ANCHORS REQUIRED IN SILL. 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE �� CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 6. 9/22/2017 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E. BE PROTECTED TO PREVENT REACTION. FL PE#58201 1239 JABARA AVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 6. PH.941-380-1574 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. SHEET DESCRIPTION: INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. ANCHOR SCHEDULE AND INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. DRAWN Br. DATE: 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. BAT 06/18/12 SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. DWG#: REV.: CWS-812 C 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOW ING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMA/AAMA 100(FIN WINDOWS),FMA/AAMA200(FLANGE WINDOWS), FMAANDMA250(BOX WINDOWS),FMA/AAMAANDMA 300(EXTERIOR DOORS) 1:15 5OF6 TYPICAL HEAD ANCHORAGE usmo MIN.EMBEDMENT MIN.EDGE DIST. SEE TABLE 1 SUBSTRATE SEE TABLE 1 BY OTHERS OCA A, LTH AVE. 114"MAX.SHIMESEALANTBEHIND BLE 1 OCALA,FLORIDA 34474 SUBSTRATE BY OTHERS W W W.CW S.CC SEE TABLE 1 MIN.EMBEDMENT PERIMETER SEALANT SEE TABLE 1 GE DIST. 8100 PVC INSIDE BYINSTALLER ND SEE TABLE SINGLE HUNG SEALANT BEHIND INSTALLATION ANCHOR IMPACT FLANGE BY INSTALLER 1/4'MAX SHIM p Q Z � aZ0 'I F owp QWO 0 zw o ;Fcm§>-zOz oW3m EALANT LL F W Z H 2 Z Z=m a W W O O INSTALLATION ANCHOR UT U U m�z D<. IL SEE TABLE 1 IND O Z ]—Z F O�_ FLANGE BY INSTALLER O Z V C Z 0 U PZ u M 0 Z CONTINUOUS DOUBLE 3/16"BEADS OF n HORIZONTAL SECTION a � O U Z uj TREMGLAZE U1600 SEALANT AROUND 6 TYPICAL JAMB ANCHORAGE W OLL O y O W U)W PERIMETER AT ALL INDICATED POINTS Z to w p_j tq I-_ BETWEEN FRAME AND BUCK BY INSTALLER. d 10. w O 5 to O W1. 0 W CL=2 1/4'MAX SHIM a H- a w a SEALANT BEHIND FLANGE BY INSTALLER udii##• ��% piO10RE4y •� . PERIMETER SEALANT MIN.EMBEDMENT �CENS .,�Qy��• BYNSTALLER SEE TABLE 1 v. No 58201 INSIDE AND OUT % SUBSTRATE BY OTHERS %13STATE OP �4r` SEE TABLE 1 MIN.EDGE DIST. •ii4........RO-."��,`� SEE TABLE 1 •��#'S70NA1-EN��,� �q1 VERTICAL SECTION •�#fee Ila* 6 TYPICAL SILL ANCHORAGE a 9/22/2017 TABLE 1:APPROVED S LATION FASTENERS LUCAS A.TURNER,P.E. ANCHOR TYPE MIN.EMBEDME FL PE#58201 PERIMETER SEALANT 1239 JABARA AVE. CONCRETE(2.0 KSI MIN.) 3/16"ITW TAPCON 1-1/2" 1-1/8" BY INSTALLER NORTH PORT,FL 34288 HOLLO INSIDE AND OUT pH.941-380-1574 C HORIZONTAL SECTION *I, CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" 1" 6 BOX FRAME INSTALLATION SHEET DESCRIPTION: GROUT-FILLED CMU(ASTM C-90) 3/16"ELCO ULTRACON 1-1/4" 2-1/2" HEAD AND SILL SIMILAR FOR BOX INSTALLATION 3/16"RVI/TAPCON INSTALLATION DETAILS 2X MIN.SOUTHERN PINE(G=0.55) 1-318" 7/8" OR ELCO ULTRACON FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8" UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: DRAWN BY: DATE: 16 GAUGE(0.060')MIN.STEEL STUD #10-16 HILT]KW IK-FLEXOR r W FULL THREAD BAT 06/18/12 (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" 7/16" MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED DWG M REV.: INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. CWS-812 C 1/8"ALUM.(33 K T5 MIN.)OR #10 GRADE 5SELF-TAPPING/ FULL THREAD -PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" SHOWN FOR FLANGE WINDOWS. SCALE: SHEET 7/16" 1:2 60F6