Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
EXTERIOR RESEARCH &DESIGN,I.I.C. Certificate of Authorization#9503 Q0TRR1NrrYJERD353 CHRISTIAN STREET, UNIT 478 OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT CertainTeed Corporation Evaluation Report 3532.09.05-1113 20 Moores Road FL5444-R12 Malvern, PA 19355 Date of Issuance:09/22/2005 (610)651-5847 Revision 13:09/05/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: CertainTeed Asphalt Roof Shingles. LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. i INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 12. Prepared by: - Robert J.M.Nieminen,P.E. F The facsimile seal appearing was authorized by Robert Nieminen, Florida Registration No.59166 Florida DC4 ANE1983 ti'';%sem p 'ti;:+k % / v a , " P.E.on 09 OS 2017.This does not serve as an electronically signed 'g-'•.• document. i CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity l ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. Q0TRINITYIERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: CertainTeed Asphalt Roof Shingles, as produced by CertainTeed Corporation, have demonstrated compliance with the following sections of the 6`h Edition (2017) Florida Building Code and 61h Edition (2017) Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.11 R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.11 R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: gaiiiY Examination Reference Date UL(TST 1740) ASTM D3161 94NK9632 05/15/1998 UL(TST 1740) ASTM D3161 99NK26506 11/23/1999 UL(TST 1740) ASTM D3161 03CA12702 05/27/2003 UL(TST 1740) ASTM D3161 03CA12702 06/16/2003 UL(TST 1740) ASTM D3161 03NK29847 10/03/2003 UL(TST 1740) ASTM D3161 04CA11329 05/24/2004 UL(TST 1740) ASTM D3161 04CA32986 12/03/2004 UL(TST 1740) ASTM D3161 05NK07049 04/15/2005 UL(TST 1740) ASTM D3161 05NK16778 05/12/2005 UL(TST 1740) ASTM D3161 05CA16778 05/12/2005 UL(TST 1740) ASTM D3161 OSNK14836 05/22/2005 UL(TST 1740) ASTM D3161 05NK22800 06/22/2005 UL(TST 1740) ASTM D3462 R684 09/21/2005 UL(TST 1740) ASTM D7158 05NK08037 06/28/2006 UL(TST 1740) ASTM D3161&D3462 09CA28873 07/23/2009 UL(TST 1740) ASTM D3462 10CA41303 10/07/2010 UL(TST 1740) ASTM D3161 10CA41303 10/08/2010 UL(TST 1740) ASTM D7158 10CA41303 10/27/2010 UL(TST 17 40) ASTM D3161&D3462 10CA44960 11/11/2010 UL LLC(TST 9628) ASTM D3161,D3462&D7158 13CA32897 11/21/2013 UL LLC(TST 9628) ASTM D3161,D3462 TFWZ.R684 04/22/2014 UL LLC(TST 9628) ASTM D7158 TGAH.R684 04/22/2014 UL LLC(TST 9628) ASTM D3161&D3462 4786334434 09/16/2014 UL LLC(TST 9628) ASTM D3161&D3462 4786570826 02/12/2015 UL LLC(TST 9628) ASTM D3161,D3462&D7158 4786570717 12/16/2015 ULLLC(TST 9628) ASTM D3161&D3462 4787195678 02/09/2016 UL LLC(TST 9628) ASTM D3161,D3462&D7158 4787380356 10/26/2016 ULLLC(TST 9628) ASTM D3462 4787380357 10/13/2016 UL LLC(TST 9628) ASTM D7158 4787380357 11/08/2016 ULLLC(TST 9628) ASTM D3161 4787380357 11/09/2016 UL LLC(TST 9628) ASTM D3161,D3462&D7158 4787586427 01/25/2017 UL LLC(QUA 9625) Quality Control Service Confirmation Exp.03/09/2020 Exterior Research and Design,LLC. Evaluation Report 3532.09.05-R33 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1112 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017 Page 2 of 12 QOTRINIW- IERD 4. PRODUCT DESCRIPTION: 4.1 CT20TM,)Mm 25,XTTm 30 and XTTM'30 IR are fiberglass reinforced,3-tab asphalt roof shingles. 4.2 ArcadiaTm, Belmont®, Belmont® IR, Carriage House ShangleO, Grand Manor ShangleO, LandmarkTM LandmarkT"" IR, Landmark""' Pro, Landmark TM Premium, Landmark"" TL, Landmark- Solaris and. Landmark""'Solaris IR are fiberglass reinforced,laminated asphalt roof shingles. 4.3 NorthGate TM is a fiberglass reinforced, laminated,SBS modified bitumen roof shingle. 4.4 Presidential ShakeT°°, Presidential Shake TM IR, Presidential Shake TVm and Presidential Solaris'"' are fiberglass reinforced,architectural asphalt roof shingles. 4.5 Hatteras""',Highland SlateTm and Highland SlateT""IR are fiberglass reinforced,4-tab asphalt roof shingles. 4.6 PatriotT"' is a fiberglass reinforced asphalt roof strip-shingle (with no cut-outs) providing a laminated appearance through an intermittent shadow line with contrasting blend drops for color definition. 4.7 Presidential Accessory, Accessory for Hatteras, Shangle RidgeTm, Shadow Ridge TM, Cedar CrestT"", Cedar CreStTM IR, NorthGate Ridge and NorthGate Accessory are fiberglass reinforced accessory shingles for hip and ridge installation. 4.8 Any of the above listed shingles may be produced in AR(algae resistant)versions. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use within FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 All shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H, indicating the shingles are acceptable for us in all wind zones UP to Vasd = 150 mph (Vint= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 Presidential Accessory,Accessory for Hatteras,Shangle Ridge,Shadow Ridge,Cedar Crest, NorthGate Ridge i and NorthGate.Accessory hip,&ridge shingles have been evaluated in accordance with ASTM D3161,Class F. All except NorthGate Ridge and NorthGate Accessory require use of BASF Sonolastic NP 1 adhesive or Henkel PLO Polyurethane Roof & Flashing Sealant, applied as specified in manufacturer's application I instructions, for use in wind zones up to Vasd=150 mph(V„It=194 mph). 5.4.3 Classification by ASTM D7158 applies to-exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. i Contact the shingle manufacturer for data specific to each shingle. 5.4.3.1 Analysis in accordance with ASTM D7158 indicates the measured uplift resistance(RT)for the CertainTeed asphalt Roof shingles listed in Section 4.1 through 4.6 (except Presidential Solaris""') exceeds the calculated i uplift force (FT) at a maximum design wind speed Of Vasd = 150 mph (V„It = 194 mph) for residential buildings located in Exposure D conditions with no topographical variations (flat terrain) having a mean roof height less than or equal to 60 feet. The shingles are permissible under Code for installation in these conditions using the installation procedures detailed in this Evaluation Report and CertainTeed minimum requirements, subject to minimum codified fastening requirements established within any local jurisdiction,which shall take precedence. 5.5, All products in the roof assembly shall have quality assurance audits in accordance with F.A.C. Rule 61G20- 3. Exterior Research and Design,I.I.C. Evaluation Report 3532.09.05-R13 Certificate ofAuthori:ation#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R12 CertainTeed Asphalt Roof Shingles;(610)651-5B47 Revision 13:09/05/2017 Page 3 of 12 QO TRINITY I ERD 6. INSTALLATION: 6.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.1 Underlayment shall be acceptable to CertainTeed Corporation and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Installation of asphalt shingles shall comply with the CertainTeed Corporation current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or Section R905.2.6 and the minimum requirements herein. 6.2.1 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.2 Where the roof slope exceeds 21 units vertical in 12 units horizontal, use the"Steep Slope"directions. 6.3 . CertainTeed asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and CertainTeed published installation instructions. 6.4 CT207;X17-25,XT-30,XT'30 IR: LOW AND STANDARD SLOPE STEEP SLOPE ENGLISH 12" 12" 12" Use tour nails and six spots of asphalt roofing cement*for every full 305 mm) (305 mm)� (305 mm) shingle(Figure 11-4).Asphalt roofing cement meeting ASTM D4586 t_toF"(25 mm) Selant 1"(25 rn Type His suggested. 5 5/a"(145 mm5 t&,forNorm 4� Roofring METRIC 131/8" 131/a" 131/8" Cement i 1"(25 mm) —Sealant lant 1"(25 mm) Apply 1"(25 mm)spots of asphalt roofing cement under each tab corner. 61/8" Figure 11-x•Usefour nails and six spots ofasphalt rxmarton steep stopae *CAUTION.Excessive use of roofing cement can cause shingles to blister, Figure 11-3:Use four nails for eueryfull shingle. 6.4.1 Hip&Ridge for CT20TM,XT""25,XTrm 30,XT"°301R: Cut Shingles I� �2"(50 mm) .-Remove (251mm)I jt ter lir jIT 5 12"(305mJ`� fl— — — V — — Y _ j1 I (125 mmm) — _ _ _ _ _ _ 1 P `25R� Cap Cap Cap 305mm) •a ��`mas Shingle Shingle Shingle Figure 11-24.•Cut tabs,teen trim back to make cap shingles �`x. (6ngUsh dimensions sbown). l5,lz Figure 11-25.'Installation of caps along the Lips and ridges. 6.4.1.1 For ASTM D3161,Class F performance use BASF"Sonolastico NPJTM"adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. i Exterior Research and Design,LLC. Evaluation Report 3532.09.05-R33 Certificate ofAuthortration#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R12 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017 Page 4 of 12 TRINITY I ERD 6.5 ARCAD14rm: LOW AND STANDARD SLOPE STEEP SLOPE Use SIX nails for every full shingle located as shown below. Use SIX nails and FOUR spots of asphalt roofing cement for every full shingle as shown below.Apply asphalt roofing cement 1"(25 min) from edge of shingle.Asphalt roofing cement meeting ASTIM D 4586 'l pe fI is suggested. +-1'(25mm) 1'(25 mm) •-- Nail Line Nail Nail Line +1'(25 mm) 1'(25 mm) Figure 2:Use sir nails for ererp fill sbingle. L �' Figure 3:Use six nails crud four spots of asphalt roofing cement on steep slopes. 6.5.1 Hip&Ridge for ArcadiaTm: Cedar Crest'"',Cedar Crest'"' IR Use two (2), minimum 1%-inch long fasteners per shingle. For the starter shingle, place fastener 1-inch from each side edge and about 2-inch up from the starter shingle's exposed butt edge,ensuring minimum %-inch embedment into the deck,or full penetration through the deck. For each full Cedar Crest shingle, place fasteners 8-5/8-inch up from its exposed butt edge and 1-inch from each side edge. For ASTM D3161,Class F performance use BASF"Sonolastic®NP1'""'adhesive or Henkel "PL® iPolyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements,to hand-seal I Cedar Crest shingles. Apply NP 1 or PL adhesive from the middle of the shingle's raised overlay on the itop piece and extending approximately 4-inch along the sides of the headlap along a line%to 1-inch from each side of the shingle's headlap. Immediately align and apply the overlying shingle,gently pressing tab sides into the adhesive,and install nails. To secure the other side,apply a 1-inch diameter spot of NP 1 or PL adhesive between the shingle layers. Hand-sealing adhesive t2' 4" ' 8" 05 mm) 1/4" 203 r(nn) I✓( 3 ( I� posure 3/4'.—► I�- i f`2,A�ml I — Dab of asphalt cement between 1„ shingle layers Exterior Research and Design,LLC. Evaluation Report 3532.09.05-1133 Certificate of Authorizotion#9503. 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1132 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017 Page 5 of 12 i TRINITY I ERD 6.6 BELMONTO OR BELMONTO IR: Low and Standard Slope Steep Slope(greater than 21:12): (2:12 to 21:12): Use SEVEN nails and EIGHT spots of Use FIVE nails for every full Belmont shingle, asphalt roofing cement"for every full located as shown below. Belmont shingle.Apply asphalt roofing cement 1"(25mm)from edge of shingle. 11 of IMS } See below_Asphalt roofing cement meeting I—.1'(25mm) F1'(25mm►-1 r— ASTM D4586 Type II is suggested. 516'(16 mm) am, 1 1P2'(38 mm) (220 mm) w less Lj Lil A F o Additional nails if required. II r(25 mm) t'M ran)—] • I 5/8'(16 rtrn) 8518 (220 mm) 1'(7S mm)=Roofing Cament 6.6.1 Hip&Ridge for Belmont®or Belmont®IR: 6.6.1.1 Option 1: For Belmont®,refer to instructions herein for Cedar CreStTM or Cedar CreStTM IR hip and ridge shingles. For Belmont®IR,refer to instructions herein for Cedar CreStTM IR hip and ridge shingles. 6.6.1.2 Option 2: For Belmont®: Shangle®Ridge i 12' 181 Exposure Remove tape from the right side 8- and fasten SECOND Fasten the Remove left side 85/8. RIGHT This Tape FIRST LEFT Figure 17-19:Installation of Sbmtgle©Ridge sbingles Figure 17-18.'Shangle®Ridge. on bips and ridges. 6.6.1.3 For ASTM D3161,Class F performance use BASF"Sonolastic®NPJTM"adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. i Exterior Research and Design,I.I.C. Evaluation Report 3532.09.05-1113 Certificate ojAuthorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-1112 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017 Page 6 of 12 I I QO TRINITY I ERD 6.7 CARRIAGE HOUSE SHANGLEO AND GRAND MANOR SHANGLEO:. LOW AND STEEP SLOPE STANDARD SLOPE Use seven nails and three spots of asphalt roofing cement for every Use five nails for every full Shangle. full Grand Hanor Shangle.Use five nails and three spots of asphalt roofing cement for every full Carriage House Shangle and Centennial Slate.Apply asphalt roofing cement t"(25 mm)from edge of shingle (Figure 17-5).Asphalt roofing cement meeting ASPM D45861I,pe 11 is suggested. 1--(25 mm) (25 mm) 1 1/2" 5/8" 8 /B" (36 mm) (16 mm) (220 mm) 1" or less _1 �-(25 mm) � (25 mm) Figure 17-4:Use free nails for et-M fill Grand Manor SAangle, 518 a/8" Carriage llouse Sbangle,or Centennial Slate. (16 mm) �� (220 mm) (25 mm) Roofing Cement Figure 17-5.When installing Grand Manor Sbangles on sleep slopes, use seven nails and ibree spots ofaspball roofing cement. 6.7.1 Hip&Ridge for Carriage House Shangle®and Grand Manor Shangle: Refer to instructions herein for Shangle®Ridge hip and ridge shingles 6.8 LANDMARK""',LANDMARK"'IR,LANDMARK-PRO, LANDMARKTm PREMIUM,LANDMARKTm TL,LANDMARK"m SOLARIS,LANDMARK""''SOLARIS IR,NORTHGATE: LOW AND STANDARD SLOPE LANDMARK TL METRIC DIMENSIONS 13th" 13" 13th" � ��--(343 mm)-►—(330 mm)—I—(343 mm)—1 12" 143/4" 12" 1-1"(25 mm) 1"(25 mm)-►I •- -(305 mm)—I—(375 mm)—I—(305 mm)-► s�s�rs�-cam rassr,.�-�*��;.�a�-��r•.'c; IL-1"(25 mm) Relea eTape 1"(25 mm)—I 1th„ NailableT " Area Figure 13-4:Use four nails for eve))-full sbingle. NorthGate: WIDE MAILtNG 12" 14314" 1r AREA (305 mm) { (375 mm) —►f(305 mm)-►I Nada Limits �~ ► j-1"(25 mm) l fine 1"(25 mm)-► �- ..2-1 lne Ar } iOEM Nailing areas for low and standard sbpos(from 2:12 to 21:12) Nall between upper B tourer Inas as shrnvn above. I Exterior Research and Design,LLC. Evaluation Report 3532.09.05-R13 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R12 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017 Page 7 of 12 TRINITY I ERD STEEP SLOPE Use six nails and four spots of asphalt roofing cement for every full LANDMARK TL laminated shingle.See below Asphalt roofing cement should meet ASTM D4586 Type IL Apply I"spots of asphalt roofing cement trade. 131/2" 13" 131/2"-� each corner and at about 12"to 13"in from each edge. r(343 mm) (330 mm) (343 mm)1-METRI(DIMENSIONS 1"(25 mm) 1"(25 mm)--+ I I 12"—+—143/4' 12" (305 mm) (375 mm) (305 mm) F __—(25 mm) � (25 mm) xr c-Q�r� :;rterWR��¢s mat -�-- Rooting Cement ;-1"(25 mm) Relea Tape 1"(25 mm) Nail Area. For Sleep Figure 13:5.•Use six nails and four spots of asphalt roof�?ngcement onsteep slopes, (25 mm) ---- (25 mm; Roofing Cement NorthGate: STEEP 12" 14-314" 12" NAIL E 1—(305 mm)—{—(375 mm)—�x(305 mmyo-I AREA,I Nailin i1"(25 mm) betwee �Fver 1"(25 mmnales. l { I � � Roofing Cement Nailing areas for steep slopes(greater than 21:12) and"Storm-Nailing" Nail between lower 2 nail lines as shown above. 6.8.1 Hip&Ridge for Landmark TM Landmarklm IR,Landmark"'Pro,Landmark''4 Premium,Landmark'"TL. ! LandmarkTm Solaris,Landmark TM Solaris IR,NorthGate: 6.8.1.1 Option 1: Shadow RidgeT""or NothGate Accessory 12" 97/8° I (305mm) (250mm) 6" 4t5/16° 415/1li (150mm) (1 50mm) (125mm) (125mm) i Notch for F- Notch for Centering Centering -712° 131/4' (305mm) Notches for Alignment toL (337mm) Notches for Alignment to 8. the Top Edge of the Previous the Top Edge of the Previous Cap for s°(125mm)Exposure(1�m) Cap for55/9'(141 mm),Exposure (ig6 m) i English Dimension Metric Dimension Shadow RidgeTM' Shadow Ridge'' Exterior Research and Design,I.I.C. Evaluation Report 3532.09.05-1133 Certil7cate o/Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R12 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017 Page 8 of 12 QOTPuNITYIERD 9 27W •-(250 mm) 415/1 ii(125 mm) 13 1/8" t—�333 mm)—s Centering Notch 6 5/8'►I1"5/8' ► (168 mm) 168 mm 131/4' (338 mm) Align these I Centering notches to top 8 131/4° Notch edge of 194 mm (337 mm previous eoutsa ( ) Align these 7 5!8° notches of top edge of (194 mm) previous course. NorthGate Ridge NorthGate Accessory 12° (305mm) Laying Notch I I 125mm) I 51(1250"n) I I I I , Figure 13-20-Use laying nokkes to center sbinglas on baps and ridges,and to locate the correct exposure 6.8.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic® NPI'""" adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. 6.8.1.3 Option 2: Refer to instructions herein for Cedar CreStTM,Cedar CreStTM IR hip and ridge shingles. I i I i i Exterior Research and Design,I.I.C. Evaluation Report 3532.09.05-1113 j Certificate ofAuthori:ation#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R12 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017 Page 9 of 12 QOTRINI-r(JERD 6.9 PRESIDENTIAL SHAKE—,PRESIDENTIAL SHAKE""IR,PRESIDENTIAL SHAKE TLT"",'PRESIDENTIAL SOLAR19m: LOW AND STANDARD SLOPE: STEEP SLOPE: For low and standard slopes,use five nails for each full Presidential. For steep slopes,use nine nails for each full Presidential shingle and shingle as shown below. apply 1'diameter spots of asphalt roofing cement under each shingle tab. After applying 5 nails in between the nailing guide lines,apply 4 nails 1" Nailing ;: 40' above tab cutouts making certain tabs of overlying shingle cover nails. Guide Lines (1016 mm) 51/4' —� (133 mm) N. 14114" 1112' 38 mm) (362 mm) • • • l — y- - - - - - - -± i 1. NOTE:Apply nails on painted guideline. Figure 16-6 FasteningPresldentlad and Prashknfial TL Slake 1'diameter asphalt roofing cement sbingles on tour and standard slopes Figure 16-7.•Fastening Presidential mrd hwidentirrl T/L Sbake shingles on steep scopes. 6.9.1 Hip&Ridge for Presidential Shake TM,Presidential Shake TM IR,Presidential Shake TLT"" Presidential SolarisTm: 6.9.1.1 Option 1: Presidential Accessory PRESIDENTIAL ACCESSORY Presidential accessory shingles can be used for covering'hips and ridges.Apply shingles up to the ridge (expose no more than.7'from the bottom edge of the"tooth."Fasten each accessory with two fas- teners.The fasteners must be 13/4"long or longer,so they penetrate -either 3/4" into the deck or completely through the deck.Presidential accessory comes In two different sizes:Accessory produced in Birmingham,AL is 12"x 12%Portland,OR produces 97/8",.x 1.31/4 accessory. 6.9.1.2 For ASTM D3161, Class F performance use BASF "Sonolastic® NP11" adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements. 6.9.1.3 Option 2: Refer to instructions herein for Cedar CrestTm,Cedar CrestTM IR hip and ridge shingles. i 6.10 HATTERASTm: I LOW,STANDARD AND STEEP SLOPE; g., 9, y.. y.. I (230 mm) 1 (230 mm) (230 mm) (230 mm) I (230 mm) (230 mm) (23;.,) (230 mm) I x(25 mm) _ __25 mm)-f294 1.. 1.. ____ _- ____ „ r(25 mm) (250 mm) (2 931 m) Hooting Cement 1 Figure 15-1:Fastening nalleras Sbingles on S/mp Uci s I For steep slopes,use Ore nails and eight spots of asphalt roofing Figure 15.3:Fastening lfatteras Shingles on cement for each fun Ilmteras shingle as shmtn above.Apply I- Lore wed StandardSlopes (25mm)diameter spots of roofing cement(ASTM D 4586 Typc u For low and standard slopes,use Ole nails for each full suggeste)under each tab corner.Press shingle Into place,do not Hatteras shinghe v shown above. expose cement. CAIMON:Too much roofing cement can cause shingles to blister. Exterior Research and Design,I.I.C. Evaluation Report 3532.09.05-R33 Certificate of Authorization#9503 6T”EDITION(2017)FEIC NON-HVHZ EVALUATION FL5444-1112 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017 Page 10 of 12 TRINITY I ERD 6.10.1 Hip&Ridge for HatterasTm: 6.10.1.1 Option 1: Accessory for Hatteras t Fasten bothsides t _ 1 2 3 Figure 15-14. 18 three-piece units separate to make 54 Hatteras Awassory shingles 6.10.1.2 Option 2: Cut Hatteras Shingles 9r (230 mm) I I I I I 1.P Fasten I I 8' 18"(460 mm) 6%Z\ (203 -- - -y---I--- 18" (203 mm) _•��� S`aes26 ml -- ------ -- 460 mm) Cap Cap Cap Cap Shingle. Shingle Shingle Shingle 9 Figure IS-20:Cut Hatteras shingles to make coaPx cap. Figure 15-21 Installation of caps along hips and ridges 6.10.1.3 For ASTM D3161, Class F performance use BASF"Sonolastic® NPI—" adhesive or Henkel "PL® Polyurethane Roof&Flashing Sealant",in accordance with CertainTeed requirements.SL 6.11 HIGHLAND ATETm.HIGHLAND IR: LOW AND STANDARD SLOPE: STEEP SLOPE: it s a s Use FIVE nails and EIGHT spots of asphalt roofing.cement•for each 2'o.4 taao�i Raomm) ��i fall Highland Slate shingle.For Miami-Dade,SIX nails are required. Apply f'diameter spots of asphalt roofing cement under each tab RS mn) Rs mm) comer.Asphalt roofing cement meeting ASTM D4586 Type R is suggested. I 6318' R]U^ml (Eo) @Umlm (240-4 i Miami Dade requss � att (25 mm) installed onapsvercear adoutasawn). � MSims -' s ' Sm )IXFWDdeqs P40 o Installed ever mlar MANAM&mn) RootNg CementFigurell-3:Use FIVE nadsforewy HigbkuuSlate sbingls mm) Figure 113A:Use F1W nails and eight spots of aspball roofing cemmnt under eacb tab corner. i I *CAUTION:Excessive use of roofing cement can cause shingles to blister. 6.11.1 Hip&Ridge for Highland Slaterm,Highland SlateTm IR:Refer to instructions herein for Cedar CrestTM,Cedar Crest T14 IR or Shangle RidgeTm hip and ridge shingles. Exterior Research and Design,I.I.C. Evaluation Report 3532.09.05-R33 Certificate of Authorization#9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FLS444-R12 CertainTeed Asphalt Roof Shingles;(610)6S1-5847 Revision 13:09/05/2017 Page 11 of 12 TRINITY I ERD 6.12 PATRIOT"": LOW AND STANDARD SLOPE STEEP SLOPE Use FOUR nails for every full shingle localed as shown below. Use POUR nails and four spots of asphalt roofing cement for every full shingle as shown belong Asphalt roofing cement meeting ASTM D4586 Type Il is suggested.Apply 1"(25 mm)spots of asphalt roofing Sealant cement as shown. i __!i______J CAUTION:Excessive use of roofing cement can cause shingles to blister. ;--1'(25 mm) (156 mm) I� 133m M (333 mm) (333 mm) (333 inn) ii�-71'j275rr;7)) * r(25 nua}—a6-t!B' oLT nnp Cement 1—(31 2-tte' -� t3 tie •}� 12-11T ►I 08rrc Pin)) (308nm) 6.12.1 Hip & Ridge for PatriotTM: Refer to instructions herein for Cedar CreStTM, Cedar CrestTm IR, Shadow RidgeTM, NorthGate or Shangle RidgeT"hip and ridge shingles. 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this j product. 9. MANUFACTURING PLANTS: I Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC-QUA9625;(414)248-6409;karen.buchmann@us.ul.com I j -END OF EVALUATION REPORT- I i I I Exterior Research and Design,I.I.C. Evaluation Report 3532.09.05-R13 Certificate ofAuthorizotion 119503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL5444-R12 CertainTeed Asphalt Roof Shingles;(610)651-5847 Revision 13:09/05/2017 Page 12 of 12