Loading...
HomeMy WebLinkAboutDrawing Fore HURRICANE SHUTTERS; INC. PANELS • ACCORDIONS,•.BAHAMAS COLONIALS • ROLL UPS Property Information Building Information Owner: Jason Heisler Wind Zone: 170 MPH. Address: 5305 Statley Oaks Street Exposure Category: B Fort Pierce,F134981 Minimum Building Dimension: 5 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 100 141 7 26.5 -29.2 2 Int 124 87.5 7 27.1 -29.7 4 Int 43.25 70 7 29.7 -32.3 5 Int. 33.5 45 7 31.1 -33.7 6 Int 43.25 70 7 29.7 -32.3 7 Int 43.25 70 7 29.7 -32.3 8 Int 33.5 83 7 29.8 -32.5 9 Int 33.5 83 7 29.8 -32.5 10 Int 72.5 108 7 27.7 -30.4 11 Int 277.25 108 7 25.0 -27.7 12 Int 33.5 84 7 29.8 -32.5 13 Int 33.5 83 7 29.8 -32.5 14 Int 33.5 83 7 29.8 -32.5 15 Int 37.5 91 7 29.4 -32.1 Prepared in accordance with:ASCE 7-10,Chapter 30.Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1 Opening 1. Bertha High Velocity Accordion (Front Door) 2.".050 Aluminum Panel(H) (Arch Window) 4. Bertha High Velocity Accordion (Window) 5. Bertha High Velocity Accordion 9 8 7 (Window) 6. Bertha High Velocity Accordion (Window) 7. Bertha High Velocity Accordion (Window) 8.. Bertha High Velocity Accordion 10 6 (Window) i 9. Bertha High Velocity Accordion 11 (Window) Window and Whole Patio 10. Bertha High Velocity Accordion (Slider) 11. Bertha High Velocity Accordion (Patio&Window) Window and Whole Patio 12. Bertha High Velocity Accordion (Window) 13. Bertha High Velocity Accordion 5 (Window) 12 14. Bertha High Velocity Accordion (Window) 15. .050 Aluminum Panel(V) 1 (Arch Window) 114 2 � i oo rn 15 N Y M 4 .� (B Il = O aS C L) Ca Ll M -� Lr) C) ° M.Il U) COPYRIGHT E-TEMPEST.COM SCALE! NOT TO SCALE DATE: Jun 07,2018 PAGE DESCRIPTION- Site Plan PAGE: OF ` 1 1 evice or System Identification Schedule for Opening Protective D -- - (The following minimum information shall be provided to facilitate plan review and inspection of the proposed installation,opening,protective device or system) Address: 5305 Statley Oaks Street, Fort Pierce, Fl 34981 Type of Structure: PERMIT#: Dev. Device Device Opening Opening Shutter Shutter #Storm Anchor - Header # Type Manufacturer Approval Width Height Width Height Bars Req. Spacing Reinf.Re 1. Accordion ASSA FBC 100 135 100 141 12 No 2. Panel EMS FBC 118 82 124 87.5 12 No 4. Accordion ASSA FBC 37 64 43.25 70 12 No 5. Accordion ASSA FBC 26 39 33.5 45 12 No 6. Accordion ASSA FBC 37 64 43.25 70 12 No 7. Accordion ASSA FBC 37 64 43.25 70 12 No 8. Accordion ASSA FBC 26 77 33.5 83 12 No 9. Accordion ASSA FBC 26 .77 33.5 83 12 No 10. Accordion ASSA FBC 64 102 72.5 108 10 No 11. Accordion ASSA FBC 253 102 277.25 108 10 No 12. Accordion ASSA FBC 26 78 33.5 84 12 No 13. Accordion ASSA FBC 26 77 33.5 83 12 No 14. Accordion ASSA FBC 26 77 33.5 83 12 No 15. Panel EMS FBC 36 85 37.5 91 12 No