HomeMy WebLinkAboutProduct Approval (2) Certificate of Authorization No.29824 bmi aim 17520 Edinburgh Drive +�§ Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION!-REPORT RIDA BUILDING CODE,6'EDmoN(2017) Manufacturer. MID-STATES ASPHALT AND CANT S IP,INC. issued October 11,2017 1637 51"Street Tuscaloosa,AL 35401 (800)489-2391 www.msaroofcom Manufacturing Location: Tuscaloosa,AL Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Undedayments Code Sections: 1504.3.1,1507.1.1 Properties: Physical properties PRODUCT DESCRIPTION AND LIMITS OF USE QUIK-Stick lee&Water QUIK-Stick Ice S Water Granular is ASTM D 1970 self-adhesive underlayment Granular constructed from SBS modified asphalt a fiberglass mat reinforcement and surfaced with granules. The product is supplied n 2 sq,rads with nominal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 5 mils. QlliK=Stick ice&Water Granular is pe itted to be used as prescnbed.in FBG Section 1507.1.1 for mechanically attached roofi coverings. Exposure on the roof deck shall be limited to a maximum 30 days. QUIK-Stick Ice&Water QUIK-Stick Ice & Water Sand is ASTM D 1970 self-adhesive underlayment Sand constructed from SBS modified asphalt ith a fiberglass mat reinfumement and surfaced with sand The product is supplied in 2- q.rolls with nominal dimensions of 3-11 x 66.8-ft and has a nominal thickness of 50 mils. QUIK-Stick foe& Water Sand is pTngcoveyings. to be used as prescribed in FBC Section 1507.1.1 for mechanically attached Exposure on the roof deck shall be limited to a maximum 30 days. QUIK-Stick HT QUIK-Stick HT is an ASTM D 1970 s -adhesive undedayment constructed from SBS (High Temperature) modified asphalt with a fiberglass m reinforcement and poly-fabric surface. The product is supplied in 2-sq-rolls with no 'nal dimensions of 3-ft x 66.8-ft or 3-ft 34n x 61- ft and has a nominal thickness of 60 mil . QUIK-Sfick HT is to be used as prescri in FBC Section 1507.1.1. QUIKStick HT is permitted to be used with adhered , ay or concrete We roofing using either ICP Adhesives Polyset AH-160 QCP Adhe es and Sealants, Inc.). Exposure on the roof deck shall be limited to a maximum 90 ays. The maximum roof slope shag be 6.12 en used with day or concrete file installations without battens. Tile shag be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stalk. MSA17001 FLiT401-R4 Page 1 of This evaluation report is provided far State of Florida product approval uRule 61G203. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance than es throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty.installation. ended use,or other product attributes that are not specifically addressed herein. `. CREEK MID-STATES ASPHALT AND CANT STRIP,INC Self Adhering Undedayments A�i TECHNiCAL SERVICES,LLC QUiK-Stick HT Pro QUIK Stick HT Pro is an ASTM D 1970 f-adhesive undedayment constructed from (High Temperature) SBS modified asphalt with a fiberglass m It reinforcement and poly-fabric surface. The product is supplied in 2-sq. rolls with no inal dimensions of 3-ft x&S.8 ft and has a nominal thickness of 60 mils. QUIK-Stick HT Pro is permitted to be u as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. osure on the roof deck shall be limited to a maximum 30 days. GUNK-Stick FS QUIK-Stick FS is an ASTM D 1970 self dhesive undedayment constructed from SBS (Film-Surface) modified asphalt with a fiberglass mat 'nforcement and textured Min surface. The product is supplied in 2-sq. rolls with no inal dimensions of 3-ft x 66.8-ft and has a nominal thickness of 45 mils. QUIK-Stick FS is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. osure on the roof deck shall be limited to a maximum 30 days. PRODUCT APPLICATfON Min.Roof Slope: 2:12 or in accordance in with the FBC Application: All underlayments shall be installed in acc rdance with the FBC. Deck substrates shall be clean, dry, an free from any irregularities and debris. All fasteners in"the deck shall be checked for rotrusion and corrected prior to undedayment application. Prior to beginning instalia n, the undedayment shall be unrolled and allowed to relax fora minimum of 3-5 min tes. - The underlayment shalt be installed with a release backer removed.and pressed firmly into place to ensure complete contact M the deck.The undedayment shall be installed with the roil length parallel to the eave, Fling at the eaves and with minimum 3-side laps-and minimum 6"end taps staggered in.6-ftfrom preceding course. It is permissible to back nall the underka ent 12-inches on-center as needed(nails shall be installed perpendicular to deck with a trail heads flush to the top surface of the underlayment). Min.Application 40°F;Confact the manufacturer when in ting at temperatures below the minimum i Temperature: application temperature. WIND RESISTANCE The Maximum.Design Pressures shown below were calculated using 2:1 margin of safety per FBC Section 1504.9. Undedayment System mo.1—CUHT niC ty Roof Deck: Min.15132-inch CDX plywood attached t wood supports spaced a maximum 2,V o.c. Underlayment QUIK-Stick H3 shall be fully adhered to I ie optionally primed plywood deck. Maximum Design -52.5 psf Pressure: MSA17001 FL17401-R4 Page 2 of 4 This evaluation report is provided for State of Florida product approval under 61 G20-3. The manufacturer shag notify CREEK Technical Services,LLC of any product changes or quality assurance thong throughout the duration for which this report is valid.. This evaluation.report does not express nor imply warranty,installation,reco nmended use.or other product attributes that are not specifically addressed herein. i � I MID-STATES ASPHALT AND CANT STRIP,INC !xp- CREEKSelf-Adhering Undertayments TECHNICAL SERVICES,LLC GENERAL Umiu'nONS 1) This evaluation report is not use in the HVHZ. 2) Fire.Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this rt,the FBC,and the manufacturer's published application instructions. Where discrepancies exist betweer these sources,the more restrictive and FBC compliant installation detail shall.prevail. 4) The roof deck shall be constructed of closely fitted plywood Bathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in 3ccordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the de k. 7) The underlayment may be used as described in other current BC product approval documents. 8) Design wind load pressures shall be determined for comp nests and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance W FBC requirements to resist the design wind load pressures for componentsand cladding. 10) Maximum Design Pressures for a given undedayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under c i quality assurance program in compliance with Rule 61020-3. REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) BWR-514-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) BWR-522-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) BWR-533-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST5878) BWR-534-02-01 ASTUD 1970 2015a ASTM D 4798 2011(2016) 'PRI Construction Materials Technologies(TST5878) SWR 543-02-01 ASTM D 1970 2015a PRI ConstmetionMaterials Techndlogtes:(TST5878) WRMI-011-02-01 ASTM D 1970' 2015a PRI ConstU fiction Materials Technologies(rST6049) -MSA-007-02-01 UL 1897 "" 2012 PRI Construction Materials Technologies(TST6049) MSA-026-02-01 ASTM D 1970 2015a I MSA17001 FL17401-R4 Page 3 of 4 This evaluation report is provided for State of Florida product approval under ule 611320-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance change.throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, runerided use..or other product attributes that are not specifically addressed herein. MID-STATES ASPHALT AND CANT STRIP,INC CREEKSelf-Adhering Underlayments IL s TECHNICAL SERVICES,LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have dem 3nstrated compliance with the Florida Building Code,6Edition(2017)as evidenced in the referenced documents sul imitted by the named manufacturer. �r,�u rurrrr ,%01,�.RY.R. 2017.10.11 11 :41:31 �y No 74021 j � R� •(^yam� WWMMbnMi,Ne -04'00' �O•,•• STATE OF •- Q _�� Zachary R.Priest,P.E. �i��S••� R t.�•• ��%�` Florida Registration No.74021 �% Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under.this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any i ompany manufacturing or distributing products under this-evaluation. Zachary his evaluation- Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.-Priest,P.E.does-not have,nor will acquire,a financiaUnterest'in ai iy other entity involved,inths approvaLprocess of.the product. END OF REPORT MSA17001 FL17401-R4 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20.3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance chang throughout the duration for which this report is valid. This evaluatiorrreport does not express nor imply warranty,installation,rm mmended use,or other product attributes that are not specifically addressed herein.