HomeMy WebLinkAboutProduct Approval RECEIVED
JUN 18 2018
SINGLE HUNG ELEVATION (LARGE MISSILE IMPACT) PVC W-PACTReQUIRENItNi: _'
1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA
54 3/8" _ BUILDING CODE,CURRENT EDITION
OVERALL FLANGE WIDTH 2.GLAZING OPTIONS:(SEE SHEET 3)
531/8"MAX UNIT WIDTH - 3.CONFIGURATIONS:"OX'.
4.DESIGN PRESSURE RATING:
4815/16" - 37114• -NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E 1300.
GLASS DLO OVERALL FLANGE WIDTH -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER
/A - - INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E 1300.
\7 8
-- -- - 36' - 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS
MAX UNIT WIDTH PRODUCT. SEE SHEETS 7-8 FOR INSTALLATION DETAIL.WIND LOAD DURATION FACTOR Cd=1.6 WAS
77 1l4' 31 13/16'
USED FOR WOOD ANCHOR CALCULATIONS.
MAX - -
C _GLASS DLO
OVERALL __ 6.PRODUCT APPROVED FOR IMPACT RESISTANCE.THE IMPACT SWEEP LOCKS ARE INTENDED TO
OVERALL
FLANGE �F� \7, 1 I BE LEFT UNLATCHED DURING NORMAL OPERATION OF THIS PRODUCT,BUT MUST BE ENGAGED
V
HEIGHT B I Q 1 I 631/4' / 1 PRIOR TO EXPOSURE TO HURRICANE WINDS AND FLYING DEBRIS.
3315/16" OVERALL
7 GLASS FLANGE i / i 7.ALL FRAMES AND VENTS FULLY WELDED.SMALL JOINT SEAM SEALANT USED AT FIXED MEETING
\ , DLO HEIGHT RAIL AND JAMB.
76"
v I 1 / I O GLASS 8.REFERENCE TEST REPORTS:NCTL-210-3668-1,-1A,-2,-2A,NCTL-210-3669-1,AA,-2,-2A
MAX,MA
UNIT 6I7 ,- / DLO
HT. 1 UNITi/ 9.SERIES!MODEL DESIGNATION SH-8100.
� HEIGHT
I I 10.1x OR 2x WOOD BUCK OR STUD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY
I / 1 L I I I TRANSFER ALL LOADS TO STRUCTURE.BUCK AND FRAMING IS RESPONSIBILITY OF ARCHITECT OR
3MAX I I ENGINEER OF RECORD.
34
SASH �/ GLASS 30 5/16' /
/� DLO MAX 11.THE DESIGNATION X AND O STAND FOR THE FOLLOWING:X=OPERABLE SASH,O=FIXED SASH
HEIGHT SASHv
/ 27*
HEIGHT I ^ I GLASS DLO 12.SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR LOCATION.
I / I 13.SWEEP LOCKS INSTALLED ON WINDOWS OVER 37"X 62"
1
-- -- - 28' _
4'O.0 - - </D GLASS DLO
WEEPS(TYP) \7 - 315/16' -
46 318' - MAX SASH WIDTH
GLASS DLO
4911/16*
MAX SASH WIDTH
DESIGN PRESSURE RATING DESIGN PRESSURE RATING
±67.5 +67.5/-75.0 B UPDATED PER 2010 FBC 11/08/2011 TEF
LUCAS A.TURNER,FL.P.E.,58201 A UPDATED''••PEE__R--N--_EW FBC REQUIREMENTS 07/07/2008
PNOENS.,TG��' C���Lt(Jv1L
. C F •.2'y WINDOWS a DOORS
TABLE OF CONTENTS No 58201 :�P 1900 SW 44TH AVE.
t * *: CALA,FLORIDA 34474
GENERAL NOTES&ELEVATIONS........1 i v: 2IITLENERAL NOTES&ELEVATIONS-LARGE MISSILE IMPACT
ANCHOR SCHEDULE&NOTES.............2 Lucas A.Tumer,P.E. 2011-11-29 00:54-05:00 ��-- :9: STATE OF :/u
SERIES GLASS DETAIL........................................3 'O <u 8100 ADE 06/10/2008
SECTION VIEWS...................................4-5 THEINFORMFTONCONTANEDONPoMMYANDCCOWIDENTAL IS ESOLEPROPERTYOF?SUS70M ,��i�s �OR1CP'G�2� M DEL GALE
EXTRUNSTALSIONS&LATONDETAL............_.........78 REPRODUCTION
PRO NDOWSINPART RASA WHOLE PROHIBITED. EV�����q;�NA,1,', ` PVC SINGLE HUNG Ev eTNeR HEFT TS CWS-155
OF B 1 OF 8
_ _ INSTALLATION ANCHORS, INSTALLATION ANCHORS,
MAX(T-P) — 1 (TYP) SEE NOTE 2 SEE NOTE 2
8" 4"MAX.(TYP)— — 8-MAX.OC(TYP)
MIDSPAN g•MAX.OC — —
MAX(TVP) —— A t 6" — 4"MAX.(TYP)
1 i 4^MAX(TYP) —— —— MAX(TYP)
( —— ——
6' 4'MAX(TVP)
14"O.C. / MAX(TYP) 1
8' .OC
MAX.(TVP) 8'MAXM I 1 I I (T MAX.OC
t MAX O.C.• I / I (TYP)t
MAX O /
1' 1g^ I // I I t ' ► I // I
76"
BI 4't t4' e^ B t O
MAX i 14" I 14.1 1 62^
UNIT6' 1 / 1 6' MAX
I
HEGHT UNIT 1 4"
I HEIGHT I
XX I I I
I / I
X I I X
INSTALLATION
36' ANCHORS,SEE NOTE 6
53118' A — (r INSTALLATION MAX UNIT WIDTH
MAX UNIT WIDTH ANCHORS,SEE NOTE 6
INSTALLATION ANCHOR LAYOUT-(FLANGE) ANCHOR LAYOUT-(FIN) ANCHOR LAYOUT-(FLANGE) ANCHOR LAYOUT-(FIN)
ANCHORS,SEE NOTE THRU FRAME MASONRY THRU FRAME(WOOD) THRU FRAME(MASONRY) THRU FRAME(WOOD)
rNIT SIZE:53-1/8 X 76 MAX UNIT SIZE:53-t18 x 76 MAX UNIT SIZE:36 x 62 MAX UNIT SIZE 36 z 62
SWEEP LOCKS) (W/SWEEP LOCKS) DP+67.51-75.0 DP X67.5/-7S.0
NOTES: DP-67.5 DP 67.5
1.INSTALL ONE ANCHOR AT EACH LOCATION.SILL ANCHOR SPACING SAME AS HEAD.
2.SHIM AS REQ'D AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4'. USE SHIMS WHERE SPACE GREATER THAN 1/16'IS PRESENT.
3.LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED.
4.3/16"DIA.ELCO ULTRACON MASONRY ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN.EMBEDMENT OF 1 114'INTO MASONRY THRU FRAME OR THRU 1 BY WOOD BUCK INTO MASONRY,A MINIMUM EDGE DISTANCE OF 2 1/2'SHALL BE ACHIEVED IN
ANY DIRECTION.
5.#10 WOOD SCREW ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN.EMBEDMENT OF 1 3/8'INTO 2 BY WOOD BUCK.A MINIMUM EDGE DISTANCE OF 7/8'SHALL BE ACHIEVED IN ANY DIRECTION.
6.#8 WOOD SCREW ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN.EMBEDMENT OF 1 1l2"INTO 2 BY WOOD BUCK FIN INSTALLATION.
A MINIMUM EDGE DISTANCE OF 1/4'SHALL BE ACHIEVED IN ANY DIRECTION. B UPDATED PER 2010 FBC 11/08/2011 TEF
7.ALL INSTALLATION ANCHORS MUST BE MADE OF OR COATED WITH A CORROSION RESISTANT MATERIAL.DISSIMILAR MATERIALS OR MATERIALS IN LUCAS A.TURNER,FL.P.E.,58201 q I UPDATED PER NEW FBC REQUIREMENTS 07/07/2008
CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTIONS. rp"
8.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS gy •%�Np RE Ij-,
SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW. ��'4?Z5 P'G E"N TG,�
, SF':�2�: Wwoows"DOORS
9.INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIAL WITH THE FOLLOWING PROPERTIES: J' No 56201 •'�P' 1900 SW 44TH AVE.
A.WOOD-MINIMUM SPECIFIC GRAVITY OF G=0.55(SOUTHERN PINE OR GREATER) "�, L
B.CONCRETE-MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. `*: i: CALA,FLORIDA 34474
C.MASONRY-STRENGTH CONFORMANCE TO ASTM C-90,GRADE N,TYPE 1(OR GREATER). yam,' * 2 I L ANCHOR SCHEDULE 8 NOTES-LARGE MISSILE IMPACT
10.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS IN ACCORDANCE WITH THE �- 13S
TATE OF -W qT
y
CURRENT VERSION OF THE FOLLOWING REFERENCE DOCUMENTS ,n,,c P, 8100 ADE 06/10/2008
PROPRIETARY AND COWIDENTML 11/28/11 �'",C O R 1�.•'•��� MODEL CALE:
FMAIAAMA 100(FIN WINDOWS).FMAIAAMA 200(FLANGE WINDOWS), THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM
FMA/WDMA 250(BOX WINDOWS),FMA/AAMAIWDMA 300(EXTERIOR DOORS). WINDOW SYSTEMS.INC.ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THEA'�•��•`�� PVC SINGLE HUNG NT$ CWS-155
WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS.INC.IS PROHIBITED. ��I�71111I�,����� EV.LETTER BSHEET. 2 OF 8
718.OVERALL INSULATED GLASS - - 7/8"OVERALL INSULATED GLASS - - 7/8.OVERALL INSULATED GLASS - - 718'OVERALL INSULATED GLASS
1/8"ANNEALED - - 118"ANNEALED - - - 1/8"TEMPERED - - 1/8"TEMPERED
7/16'AIRSPACE - - 7116'AIRSPACE - - - 7116'AIRSPACE - - 7/16'AIRSPACE
5116'LAMINATED GLASS - - 5/16"LAMINATED GLASS - - 5/16'LAMINATED GLASS - - 5/16•LAMINATED GLASS
1/8"ANNEALED - - 118"ANNEALED - - 118"ANNEALED - - 1/8'ANNEALED
090•PVB INTERLAYER BY DUPONT090•PVB INTERLAYER BY DUPONT .090•PVB INTERLAYER BY DUPONT - .090"PVB INTERLAYER BY DUPONT
1!8'ANNEALED - 1/8'ANNEALED - 1/8"ANNEALED 1/8'ANNEALED
WRASEAL BY TRUSEAL DURASEAL BY TRUSEAL OURASEAL BY TRUSEAL BY TRUSEAL
18 PURFECT GLAZE"H'OR SIKAFLEX 552 18 PURFECT GLAZE'H*OR SIKAFLEX 552 18 PURFECT GLAZE'H*OR SIKAFLEX 5JkURA
T GLAZE"H"OR SIKAFLEX 552
EXTERIOR
EXTERIOR
1 12 I 1
1/2'GLASS BITE 1/2"GLASS BITE ! 1/2"GLASS BITE 1/2"GLASS BITE
1 1 1 1
° q 4
SASH LITE SASH LITE
FIXED LITE FIXED LITE
GLASS TYPE A GLASS TYPE B
FULL SIZE FULL SIZE
B UPDATED PER 2010 FBC 11/08/2011 TEF
LUCAS A.TURNER,FL.P.E.,58201 A I UPDATED PER NEW FBC REQUIREMENTS 07/07/2008
,0'' ADREby�"Ot
Cp,�•� F••..'L�'. wwDows&DOORS
No 58201 'CP: 1900 SW 44TH AVE.
t * * GALA,FLORIDA 34474
TITLE:
9', STATE OF 'x GLASS DETAIL-LARGE MISSILE IMPACT
1.C) lug 8100 PAWN BY ADE ATE 06/10/2008
XN PROPRIETARY AND CONFIDENTML 11/28/11 i •.<O R 1 P•• M DEL-. CALE: )WQ NO
WINDOW STHE YSTMSTION,INC.ANY REPRODUCTIONONTAINED IN THIS INOIS THE SOLE PROPERTY PART OR AS WHOLE WITOF CUSTOMHOUT THE �'�i�s3/ONA**Ea�`ISN PVC SINGLE HUNG 1:1 CWS-1$S
WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS,INC.IS PROHIBITED. '�1�0IN A-�T� EV.LETTER'S HEET'. 30F6
3
139
21
3 21
15
i
41
41 �
04, EXTERIOR26
O 0
12 SECTION VIEW B-B
18 46 20 21 12
20
EXTERIOR 4
18
38 30
12
29
31
7 12 8
13
5 6 38 14
18 9 I 15
32 48 25 O
16
19 40 p
2
41
8
38 12 13
9 14
SECTION VIEW C-C
25 1 15 ALTERNATE FIN DETAIL
O B UPDATED PER 2010 FBC 11/08/2011 TEF
LUCAS A.TURNER,FL P.E.,58201 A UPDATED PER NEW FBC REQUIREMENTS 07/07/2008
40 16
2 O NOTE: J `,�Pry�REW .
41 ITEMS 22,27,28,33-37,43-45 ARE NOT `:JVP;•�G E N SF.,� ORS
SHOWN.ITEM 31 IS NOT USED IN No 58201 '.P 1900 SW 44TH AVE.
THIS WINDOW. * +: CALA,FLORIDA 34474
SECTION VIEW A-ASTATE* OF a e SECTION VIEWS 53 1/8"x76"-LARGE MISSILE IMPACT
'9 , rW
SERIES RAWNBY
8100 ADE 06/10/2008
PROPRIETARY AND CONFIDENTIAL 11/28/11 '��O�'• ORtC P'�2�� M DEL. CALE.
WINDOW PERMITHE SSION C,ININC.
ANY
REPRODUCTION
OOWS SYSTEMS, WHOLEWITHOUT
THE ONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM ��'�S��O N A'�? ` PVC SINGLE HUNG EV.LETTER: HEET-NTS CWS-155
PROHIBITED. B 4OF8
39
18 11 3
3
21 INTERIOR 10 21 15
41
1 41
EXTERIOR
o O 38 O
26
46
12 20 SECTION VIEW B-B
18 21 12
20 TYPICAL HORIZONTAL SECTION
NOTE:LEFT SIDE SHOWS FD(ED LITE CUTAWAY,
RIGHT SIDE SHOWS SASH CUT AWAY
EXTERIOR INTERIOR
4 18
30 29
38
31 y 7
5 6 12 8
32 18 38 � 9
48 25
19
40
0
2
41
12 g
36
9 ALTERNATE FIN DETAIL
25 SECTION VIEW C-C
B UPDATED PER 2010 FBC 11/08/2011 TEF
40 LUCAS A.TURNER,FL.P.E.,58201 A I UPDATED PER NEW FBC REQUIREMENTS 07/07/2006
O
2 ttpruuryrrr
41 NOTE: �,,P�P C E N j*-.G ��
SECTION VIEW A-A ITEMS 22,27,28,33-37,43-45 ARE NOT j J�, F �c��. wwnOws&nooas
SHOWN.ITEM 31 IS NOT USED IN THIS No 58201 :P 1900 SW 44TH AVE.
WINDOW. r; * ;* CALA,FLORIDA 34474
:t'= TITLE:SECTION VIEWS 36"x 62"-LARGE MISSILE IMPACT
'9 STATE OF :<u+' SERIES RAWN BY
'O . �: 8100 ATF 06/10/2008
THE INFORMATION CONTAINED INPROPTHIS DRAWING IARY AND S DENTIAL Ill HE SOLE PROPERTY OF CUSTOM ,��i FSF�O R 1 O P,G��`� M DEL. CALE ADEDWG NO
WINDOW SYSTEMS,INC.ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE ����S/ON. ? 1 PVC SINGLE HUNG NTS CWS-155
WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS,INC.IS PROHIBITED. �rlrrrrrlrr-r EV.LETTER'.B HEFT SOF 8
ITEM# PART# DESCRIPTION MATERIAL VENDOR - 3 1/8"
1 86031 Frame Head,Fig,Single Hing RIGID PJC MKRON 3 1/8" -
2 K6031 Frame Sill,Fig,Single Hung RIGID PJC MKRON I I 6' - 2 3/16' - CO STRUCTION
3 1+6031 Frame Jarrb,Fig,Single Hung RIGID PVC MKRON - 1/16' 1/16' --
4 1-1836 Alum Ftxed Meet.Rail ALUMINUM KEYMARK 1
5 S-6063 FD(ed Rail Cover RIGID PJC MKRON
6 86027 Sash Top Rail RIGID PVC MKO 15/8, 6
7 K1497 Reinforcement for STR ALUMINUM KEYMARK 3
8 1-6028 Sash Bottom Rail RIGIDP/C MKRON I
9 (+1699 Reinforcement for SBR ALUMINUM KEYMARK 1 -CORNER%WELD(ALL SIDES)
10 86004 Sash Side Rail RIGID PVC MKRON I PVC SASH TOP RAIL-6027
11 51498 Reinforcement for SSR ALLNNLtM KEYM4RK PVC FRAME FLANGE-6031 4
PVC FRAME FIN-6048
12 56064 Glazing Bead RIGID PJC MKRON
13 83118 Keeper,Sweep Lock STS SULLIVAN _13/16"_ - 115/16' -
14 83541 #8 x 1/2",Pan Head,Tek ZINC FASTBTWL ( 10 l -11/8'- 1/16'
15 P-4632 SweepLock ZINC SULLIVAN
16 84633 Barrel Fastener STS FASTBWL 15/8 1/16' 15/8' Fri
5/16'17 Bbck&Taclde Balance STS$ CALDNVB L I18 PUrfect Glaze"M or Skaflex 552 SLICOhE HBJ(E 1SKA 6
19 Sash See Glazing Chart(pg3) GLASS CARDINAL PVC SCREEN SUPPORT-6014
20 Fb(ed See Glazing Chart(pg3) GLASS CARDINAL —FIXED MEETING RAIL
21 83429 Wstp.,0.270 x 0.187 back FinSeal NYLON LLTRAFAB PVC SASH SIDE RAIL-6004 PVC SASH BTM.RAIL-6028 1 SCREWED TOGETHER WITH
22 P-4638 #8 x 2-1/2 PH MDd.Truss,Type A,TEK 2 STS. FASTENAL OUTERFRAME
23 #10 x 1 1/2"Panhead SMS STEEL FASTENAL 4
24 Flet Washer STEEL FASTBJAL 2 1/8'
15t16"
25 56014 Screen Catch RIGIDPVC MKRON 1/16"
26 56013 Screen Support RIGID PJC MKRON 1/16' - 5/8' V V
27 P-4051 #8 x 1 1/4"Ph Fh TEK,Wht. ZINC FASTENAL 1/2' 1 I _ 1 7/8"
28 83748 #6 x 0.625"Quad Fh TEK,Wht. ZINC FASTENAL I 1 1" 1116' 7 - 1 1/2' 1
29 83783 "act,Lock STS. NTEFI-OCK m ALUM.FIXED RAIL-1836
SASH STOP-6025
30 P-4069 Impact,Keeper STS INTERLOCK PVC SCREEN CATCH-6013 ALUM.REINF.TOP RAIL-1497
31 P-4264 #8 x 3/4 FH PH w I#6 Head,TEK Wht STS FASTENAL
32 P-3218 Screen Frame ALUMINUM ALLMETAL _ - 114"
33 P-3321 Screen Corner Key PLASTIC M&M 1
I �
34 83228 Screen Spline RUBBER DAPA 7/8' 1 -1/2"-
35 83581 Screen Cloth VINYL WEIR _3/4._ 1116'
36 STEEL Screen Spring STHURLEY 111 1 3/4"
37 83029 Screen PUC Tab STEEL HURLEY 3/;6'�I151I16" PVC GLAZING BEAD
SCREW SUPPORT-3113
38 83352 Set.Elk 1/8'x 5/8"x 2' RUBBER FRANK LOWS 11 1116' -8064 3/16'
39 83768 #8 x 5/8 Phil Pan Zinc ZINC FASTENAL ALUM.REINF.S.B.R./S.S.R.-1498 I
40 84479 Weepcover PLASTIC M&M ALUM.REINF. BTM RAIL-1699
41 83113 Screw Support RUBBER TEAM B UPDATED PER 2010 FBC 11/08/2011 TEF
42 86025 Sash Stop RIGID PJC MKRON �5, LUCAS A.TURNER,FL.P.E.,58201 A UPDATED PER NEW FBC REQUIREMENTS 07/07/2008
43 FL3059 Sash Cam PLASTIC M&M
44 83295 Take Out Clip STEEL SUMMIT I ♦��`�NpRE by��••�
45 83342 Seam Sealer SLICONE SCFNff 15118' S ����y P•�EN TG••••
46 P-3752 Hole Plug PLASTIC M&M CP:'�� SF''�2^ -- WINDOWS&DOORS
47 1+6048 Frame Head,FN,Single Hung RIGID PVC MKRDN I ,v No 58201 ':�P 1900 SW 44TH AVE.
48 84959 Wstp.,0.420 x 0.187 back NYLON ULTRAFAB - - e/16' : *: -ALA,FLORIDA 34474
PVC FD(ED RAIL COVER-6063 o: ;a' TITLEEXTRUSIONS/B.O.M.-LARGE MISSILE IMPACT
Az '-P STATE OF W' SERIES BY
'�0,. A' N :�Qu� 8100 ADE 06/10!2008
PROPRIETARY AND CONFIDENTML ]]/Z$/]] i F '-. ORI�.•'\�� -M-6D EL. CALE' WG NO.
NOTE:ALL ALUMINUM EXTRUSIONS ARE 6063-T6 THE WINDOW INFORMATION
CONTAINED
M TAIN DREPRODUCTIONIN THIS
INN PART OR AS A PROPERTY
WITHOUT CU THE •'0 S'& .........vx PVC SINGLE HUNG 1:2 CWS-155
WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS,INC.IS PROHIBITED. ��rrr(rrlr(((t40� EV.LETTERB HEET 6 OF 8
INTERIOR FINISH INTERIOR FINISH-� INTERIOR FINISH
BY OTHERS BY OTHERS - _ 1 114"MIN.EMBEDMENT 1 3/8'MIN.EMBEDMENT - - BY OTHERS
IC] [D]
SEALANT BETWEEN BUCK •.
AND OPENING BY OTHERS BY OTHETE/MASONRY---� t.r.:•.jyi.
BY OTHERS •••t••t•t': - - - :r;%•;�•:
� �., _ - 1/4"MAX SHIM 1/4'MAX.SHIM
[B] [B]
2 1/2'MIN.EDGE DIST. - - INSTALLATION ANCHOR,3/16"DIA.—� •'4'4 • 7l8'MIN.EDGE DIST.
(C] MASONRY SCREW WITH WASHER .' -
THRU SCREW SUPPORT \ 4'4 _ ' 0' 1 ID]
Iq
CONCRETE/MASONRY
BY OTHERS •ASTAILLATION
1 1/4"MIN.EMBEDMENT . � - INSTALLATION ANCHOR,
EXTERIOR FINISH----�ti; - A• #10 WOOD ANCHOR WITH
BY OTHERS 1 I BY WOOD BY OTHERS BUCK '4 C• WASHER THRU SCREW
SUPPORT[D]
[A] 2 1/2'MIN.EDGE DIST!A�• •[C] ' EXTERIOR Q e'A' 2 BY WOOD BUCK
PERIMETER SEALANT--/ eBY OTHERS
BYINSTALLER e'a � C A [A)
114'MAX.SHIM � SEALANT BETWEEN
SEALANT BEHIND 1/ 1 BY WOOD BUCK SEALANT BEHIND BUCK AND OPENING
FLANGE BY INSTALLER BY OTHERS FLANGE BY INSTALLER PERIMETER SEALANT BY OTHERS
[A) EXTERIOR FINISH -PERIMETER SEALANT BYINSTALLER
BY OTHERS BYINSTALLEREXTERIOR FINISH
BY OTHERS C' HORIZONTAL SECTION
ANCHOR,3116'DIA. �S- HORIZONTAL SECTION 7. FRAME(WOOD)
MASONRY SCREW WITH WASHER 7 FRAME(MASONRY)
THRU SCREW SUPPORT
[C]
INSTALLATION ANCHOR,3/16"DIA.
EXTERIOR / MASONRY SCREW w/NEOPRENE
BACKED WASHER THRU SCREW
EXTERIOR n SUPPORT[C]
SEALANT BEHIND `]JI I BOTTOM SWEEP LOCK ACITVATED ONLY
FLANGE BY INSTALLER DURING HURRICANES.(SEE NOTE 6,SHT1)
O
INSTALLATION ANCHOR,3/16'DIA. PERIMETER SEALANT SEALANT UNDER SCREW
BV INSTALLER HEAD BY INSTALLER.
MASONRY SCREW w/NEOPRENE p t
SEALANT UNDER SCREW- BACKED WASHER THRU SCREW -------.
HEAD BY INSTALLER \ SUPPORT , ° . ♦ ♦ D • 1 L
[Cl EXTERIOR FINISH .Ds• ° D D ♦ D ° D
BY OTHERS D. ♦ °
D D. s D. ♦ 114'MAX.SHIM
SEALANT BEHIND D ♦ D ° • ♦' ° ♦ D • ♦• ♦D °. ♦C [B]
FLANGE BY INSTALLER r] BOTTOM SWEEP LOCK ACTIVATED ONLY D. ♦ ,D° •D. s •D D D D D D t
Ill 1 DURING HURRICANES. ♦ D s .► D D
• D ° ♦ D D• ° 1 1/4'MIN.EMBEDMENT
PERIMETER SEALANT\ O D ° D p♦ °De ° D°e D° D. 1>
BY INSTALD• i [C]
LER D
1/4"MAX.SHIM 2 1/2'MIN.EDGE DIST.
CONCRETEIMASONRY
EXTERIOR FINISH C=- 1 -SILL STOOL BY OTHERS "D ALTERNATE PRECAST SILL DETAIL fq
BY OTHERS N •,�, ..off r BY OTHERS 7 FRAME(MASONRY) B UPDATED PER 2010 FBC 11/08/2011 TEF
' >, .ei n� _ _--•-"" USE SOLID WOOD LUCAS A.TURNER,FL.P.E..58201 A UPDATED PER NEW FBC REQUIREMENTS 07/0712008
s. '>.•P•• ••� _ SUPPORT TO MAKE
•>,s• • s. ,s•o s• .s•s• 1 REFERENCE NOTES:
p"
n • • ••> s s. • s>. • SILL LEVEL BY OTHERS r,,'% DRE
s. �,.s•.. . • �'po. : �• ,. .o•a [A] SEE NOTE 10,SMT i ,rrrr'pN W
s. s•• e;',��s. n��• >� 's. >• �
[B] SEE NOTE 263,SHT r P.�' GENS
•• -Q
•�• • •� o. •s,>••>•, .�'o!•e,•>: 1 � Glr�'.�'1, ll(��WINDOWS&DOORS
1 1l4•MIN.EMBEDMENT [C] SEE NOTE 4,SHT 2 .J F•.
• [C] [D] SEE NOTE 5,SHT 2v• No 58201 1900 SW 44TH AVE.
CONCRETE/MASONRY-- _`*:• 3.e: CALA,FLORIDA 34474
BY OTHERS _ 2 1/2"MIN.EDGE DIST. J =v: * :a' I INSTALLATION DETAIL FLG-LARGE MISSILE IMPACT
[Cl o`-- :9:, STATE OF ;4iSERIES
HIGH STRENGTH s0,�•,A' P ,��� 8100 ADE AT 06/10/2008
STRUCTURAL PROPRIETARY AND CONFIDENTML 11/28/]] ���••,(QR��•,� \�� 770 EL. CALF
GROUT BY OTHERS A VERTICAL SECTION THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM "'
U rNTS
7 FRAME(MASONRY) WINDOW SYSTEMS,
STE S,IN.ANY REPRODUCTION
PRODUCOW SIN PART.OR SA WHOLE
WITHOUT THE �''i,,��ON A;,�,?r`rr PVC SINGLE HUNG EV.LETTER B SHEET 7 O 8-156
SHEATHING - 1 1/2"MIN.EMBEDMENT
BY OTHERS \`� [EI
EXTERIOR FINISHo,° - INSTALLATION ANCHOR.
BY OTHERS #8 WOOD SCREW WAVASHER
(E]
SEALANT BEHIND FIN--�
BYINSTALLER J°• 2 BY WOOD BUCK BY OTHERS
(A)
WINDOW WRAP--- --
BY INSTALLER -.of 1
1/4"MIN.EDGE DIST.(E) 114•MIN.EDGE DIST.[E]
PERIMETER SEALANT
BY INSTALLER - --- 1 -
2 BV WOOD BUCK- - - 114'MAX SHIM
1/4"MAX.SHIM BY OTHERS IBI
[BI [A]
INSTALLATION ANCHOR,
#8 WOOD SCREW WITH
WASHER
[E]
1
_ 1 1/2"MIN.EMBEDMENT
[El
1
SHEATHING— ,e•e bo
BY OTHERS o•�;°°oe '�!e•�•o.°
•8 0
EXTERIOR FINISH
BY OTHERS -WINDOW WRAP
BYINSTALLER
SEALANT BEHIND FIN—
BVINSTALLER PERIMETER SEALANT
BYINSTALLER
BOTTOM SWEEP LOCK ACITVATED ONLY
DURING HURRICANES(SEE NOTE 6,SHT 1) F HORIZONTAL
1 8 FIN((WOOD) SECTION
O
REFERENCE NOTES:
1/4"MAX.SHIM
SEALANT BEHIND FIN IBI [A)SEE NOTE 10,SHT 1
BYINSTALLER 1 [B]SEE NOTE 2&3,SHT 2
[C]SEE NOTE 4,SHT 2
etige 1 [D] SEE NOTE 5,SHT 2 B UPDATED PER 2010 FBC 11/08/2011 TEF
PERIMETER SEALANT---� 1/4"MIN.EDGE DIST.[El [Ej SEE NOTE 6,SHT 2
BYINSTALLER 1 LUCAS A.TURNER,FL.P.E.,58201 A UPDATED PER NEW FBC REQUIREMENTS 07/07/2008
4: ------2 BY WOOD BUCK
BYItINSTALDOW WLERP — 'M1 o. [A,OTHERS ��� OREq�'10,,
EXTERIOR FINISH p�6rl•. INSTALLATION ANCHOR, ;VPy•��G E N WINDOWS&DOORS
BY OTHERS u•o•O #8 WOOD SCREW WITH WASHER No 58201 ••:P 1900 SW 44TH AVE.
[E] _;: :*:_ CALA,FLORIDA 34474
SHEATHING �! — 1 112"MIN.EMBEDMENT _ * a c L STALLATION DETAIL FIN-LARGE MISSILE IMPACT
BY OTHERS '9 STATE OF RAWN By
(TYP) 'O . <uC 8100 ADE A e 06/10/2008
PROPRIETARY AND CONFIDENTIAL 11/28/11 ����'•,;O R 1�P••���� MODEL. CALE G NO
E VERTICAL
OOD)SECTION THE WRITTEN PERM19310NCOFACUSTOM WINDOW SYSTEMS,INC.IS PROHIBITED.OOU CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM
����SfON A� ��, PVC SINGLE HUNG EV.LETNER HEET TS CWS-155
8 FIN
+�.nn��� 8 80F8