HomeMy WebLinkAboutProduct Approval (2) E)MRIOR RESEARCH&DESIGN, LLC.
: Certificate of Authorization#9503
� �IzJll ,� `,\� 353 CHRISTIAN STREET, UNIT##13
I OXFORD,CT 06478
(203)262-9245
EVALUATION REPORT
Polyglass USA,Inc. Evaluation Report P12060.02.09-R23
150 Lyon Drive FL5259-1127
Fernley, NV 98408 Date of Issuance:02/24/2009
(570)384-1230 Revision 23:09/14/2017
SCOPE:
This'Evaluation Report is issued under Rule 61620-3 and the applicab a rules and regulations governing the use of
construction materials in the State of Florida. The documentation submittd has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 61" Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify RoblIert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with.each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall berovided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the requelt of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
O _
` 'W=
Robert J.M. fUlePYllnen,P.E. �;fifi��s�ti,..f-•,.• he facsimile seal appearing was authorized by Robert Nieminen,
Florida Registration No.59166,Florida DCA ANE1983 .E.on 09/14/2017. This does not serve as an electronically
igned document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass SA, Inc., have demonstrated compliance with the
following sections of the Sth Edition (2014) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/:ndard
ditions of Use set forth herein.
2. � STANDARDS:
VearSection Pro a
1504.3.1 Wind Uplift F 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1507.2.3/1507.1.1 Physical Properties AS M D226 2009
1507.2.4/1507.1.1,1507.2.9.2 Physical Properties ASTM D1970 2015
1507.3.3 Physical Properties FRSA/TRI April 2012 2012
1 1507.11.2 Physical Properties ASTM D6164 2011
1507.11.2 Physical Properties AS M D6222 2011
1523.6.5.2.1 Physical Properties T 103 1995
TAS 110 Accelerated Weathering TA!S 110 2000
3. REFERENCES:
Enti Examination Reference Date
FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000
PRI(TST 5878) Physical Properties PF 101111 04/08/2002
PRI(TST 5878) Physical Properties Pl.SA-005-02-01 01/31/2002
PRI(TST 5878) Physical Properties PL SA-013-02-01 12/23/2002
PRI(TST 5878) Physical Properties Pl.SA-013-02-02 12/23/2002
PRI(TST 5878) Physical Properties PL SA-013-02-03 12/23/2002
PRI(TST 5878) Physical Properties Pl.SA-018-02-01 07/14/2003
PRI(TST 5878) Physical Properties Pl.SA-028-02-01 07/13/2005
PRI(TST 5878) Physical Properties Pl.SA-033-02-01 01/12/2006
PRI(TST 5878) Physical Properties Pl.SA-035-02-01 09/29/2006
PRI(TST 5878) Physical Properties PL SA-055-02-02 12/10/2007
PRI(TST 5878) Physical Properties P SA-061-02-02 01/28/2008
PRI(TST 5878) Physical Properties P SA-076-02-01 02/22/2008
PRI(TST5878) Physical Properties P SA-083-02-01 04/14/2008
PRI(TST 5878) Physical Properties P SA-088-02-01 07/29/2009
MTI(TST 2508) Physical Properties JX OH7A 04/01/2008
MTI(TST 2508) Physical Properties R 14E8A 01/29/2009
ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000
ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001
ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003
ERD(TST 6049) Physical Properties 0 200.07.03 07/14/2003
ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007
ERD(TST 6049) Physical Properties P5110.04.07-1 04/11/2007
ERD(TST 6049) Wind Uplift P 260.03.08 03/21/2008
ERD(TST 6049) Physical Properties P 3450.08.09 08/13/2009
1 ERD(TST 6049) Wind Uplift Pt 0540.11.09-R1 11/30/2009
ERD(TST 6049) Physical Properties P 1030.11.09-1 11/30/2009
ERD(TST 6049) Wind Uplift P'.1030.11.09-2 11/30/2009
ERD(TST 6049) Physical Properties P 1030.11.09-3 11/30/2009
ERD(TST 6049) Physical Properties P'3360.06.10 06/25/2010
ERD(TST 6049) Physical Properties P'3370.03.11 03/02/2011
ERD(TST 6049) Physical Properties P'3370.04.11 04/26/2011
ERD(TST 6049) Physical Properties P7300.10.11 10/19/2011
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R23
Certificate ofAuthorizotion#9503 6'EDITION(2017)F13C NON-HVHZ EVALL ATION FL5259-R27
Polyglass Roof Underlayments,(570)3 1230 Revision 23:09/14/2017
Page 2 of 14
11IRN Tl )(
Enti Examination Reterence Date
ERD(TST 6049) Physical Properties P4 390.08.12-1 08/06/2012
ERD(TST 6049) Physical Properties P4 390.08.12-2 08/07/2012
ERD(TST 6049) Physical Properties C 420.09.12-3 09/11/2012
ERD(TST 6049) Wind Uplift P3�680.03.13 03/04/2013
ERD(TST 6049) Physical Properties P4 370.04.13 04/26/2013
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013
ERD(TST 6049) Wind Uplift 11 1 57.04.01-1-RI 04/30/2013
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013
ERD(TST 604.9) Wind Uplift P11751.05.03-111 11/26/2013
ERD(TST 6049) Wind Uplift P1 781.11.03-R1 11/26/2013
ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014
ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD(TST 6049) Physical Properties 60120-09.14-2 09/08/2014
ERD(TST 6049) Physical Properties f5610.09.14-3 09/08/2014
ERD(TST 6049) Physical Properties 660.09.14-4 09/08/2014
ERD(TST 6049) Physical Properties 602'0,09.14-5 09/08/2014
ERD(TST 6049) Physical Properties 660.09.14-6 09/08/2014
ERD(TST 6049) Physical Properties P4t520.10.14 10/03/2014
ERD(TST 6049) Physical Properties P4-360.10.14 10/07/2014
ERD(TST 6049) Physical Properties P+90.10.14 10/17/2014
ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015
ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015
ERD(TST 6049) Physical PropertiesI
PLYG-SC8080.05.15-1 05/20/2015
ERD(TST 6049) Wind Uplift PLTG-SC8905.05.16-1 05/17/2016
ERD(TST 6049) Physical Properties PLTG-SC8080,07.16 07/16/2016
ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD(TST 6049) Physical Properties PLYG-SC13040,12.16 12/27/2016
ERD(TST 6049) Physical Properties PL
PL�G-SC11900.03.17 03/10/2017
ERD(TST 6049) Physical Properties G-SC12115.08.17 08/08/2017
[CC-ES(EVL 2396) IBC Compliance ES�-1697 11/01/2014
Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Pr ducts Current 02/18/2009
Polyglass USA P/1-Affidavit M le-Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Po ystick SA Compound 08/18/2011
UL,LLC.(QUA9625) Quality Control Se ice Confirmation Exp.10/05/2018
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base heet.
4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen bas I sheet.
4.1.3 Polyglass G2 Base is a fiberglass-reinforced,asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen
en base sheet.
4.2 Self-Adhering Underlayments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt wate proofing membrane,glass fiber reinforced, surfaced
with polyp Ic.-film surface;meets TAS 103.
Cj:2:2 �Polys�ticklR-Xe 163-ate 60-mil thick rubberized asphalt wat rproofing membrane,glass fiber reinforced,with an
aggregate urface;meets ASTM D1970.
TILI PI ' wh in 80-mil thick rubberized asphalt wa erprocifing membrane,glass fiber reinforced,with a
lyester f ic'su mee TM D1970 and TAS 103.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 GTH EDITION(2017)FBC NON-HVHZ EVALU TION FL5259-R27
Polyglass Roof Underlayments;(570)3 2230 Revision 23:09/14/2017
Page 3 of 14
ERC*,,
4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced,with a granular surface;meets ASTM D1970 and TAS 1 3.
4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt w terprocifing membrane with a 190 g/m2 polyester
fabric surface;meets ASTM D1970 and TAS 103.
4.2.6
Polyflex SAP, Polyflex SAP FR, Mule-hide'SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (1711) are polyester
reinforced,APP modified bitumen cap sheets;meet FRSA1TRI Apri�2012.
4.2.7 Polystick Dual ProTm is a nominal 60-mil thick dual-layer rubb rized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970.
4.2.8
Polystick Tile ProT11 is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103.
4.2.9 Polystick MU-X is a nominal 54-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
4.3 Mechanically Fastened and/or Bonded Underlayments:
43.1 Elastoflex G TU is a polyester reinforced, modified bitumen tilunderlayment composed of a sand-surfaced SBS
modified bitumen back-side and granule-surfaced APP modified bitumen top-side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened the roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System"from FRSA/TRI April 2012(04-12)beneath mechanically ilastened or adhered tile roof systems.
4.3.2 Elastoflex SIS G and Elastoflex S6 G FR are polyester reinforced,S I S modified bitumen cap sheets;meet ASTM D6164.
Elastoflex SIS G and Elastoflex S6 G FR are for use as an altern to to "Mineral Surface Roll Roofing" (ASTM D6380,
C'lass M)in the"Single Ply System"from FRSA/TRI April 2012(04- 2)beneath mechanically fastened tile roof systems.
Elastoflex SIS G is for use as an alternate to Hot Asphalt applied Cap Sheet"in the"Two Ply System"from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered ti
11'e roof systems. Elastoflex:S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet in the "Two Ply System"from FRSA/TRI April 2012
(04-12) beneath mechanically fastened or adhered the roof syst9l
ms. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI A001 2012 (04-12) beneath mechanically fastened tile
roof systems.
5. WiTATiopis:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or prev ous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report, refer to c rrent Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request ma be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting dat for the prepared roof covering.
Exterior Research and Degign,I.I.C. Evaluation Report P12060.02.09-1123
Certificate afAuthorization#9503 6'EDITION(2017)FBC NON-HVHZ TION ION FL5259-R27
PolVglass Roof Underlayments;(570):VI230 Revision 23:09/14/2017
Page 4 of 14
TRNT,( ERE",
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTJNS
Underlayment Asphalt Shingles Rail-On Tile Foam-0 Tile Metal Wood Shakes Slate
&Shingles
Elastobase Yes Yes Yes Yes Yes Yes
(Base Sheet in 2-ply system) (Base Sheet in 2-ply 1system)
Elastabase P Yes Yes Yes Yes Yes Yes
I
(Base Sheet in 2-ply system) (Base Sheet in 2 Ply system)
Yes Yesl
Polyglass G2 Base No {Base Sheet in 2-piv system) (Base Sheet in 21ply system) No No N o
Polyglass APP.Base No Yes Yesi No No No
(Base Sheet in 2-ply system) (Base Sheet in 2,ply system)
Polystick MTS Yes Yes Nol Yes Yes Yes
Pot stick 1R-Xe Yes No No No Yes Yes
Polystick TU P Yes Yes es (See E5.5.1) No Yes Yes
Polystick
Yes Yes (See 1 .5.1) Yes Yes Yes
olystick TU Max No Yes Yes (See 5.5.1) Yes No No
Polystick Dual Pro Yes No No) Yes Yes Yes
Polystick Tile Pro_ Yes Yes Yes (See 5.1) - Yes Yes Yes
Polystick MU-X Yes No No Yes Yes Yes
Elastoflex S6 G Yes Yes Yes (see .5.1) No Yes Yes
Elastof(ex S6 G FR Yes Yes Na No Yes Yes
Elastoflex G TU Yes Yes Yes (SeeJ5.5.1) No Yes Yes
Polyflex G Yes Yes Yes (See F55.1) No Yes Yes
Polyflex G FR Yes Yes
No No Yes Yes
Polyflex SAP or SAP FR Yes Yes Yes (See 5 5.1) No Yes Yes
Mule-Hide SA-APP Cap Sheet
or SA-APP Cap Sheet(FR) Yes Yes Yes (See 5.5.1) No Yes Yes
1 1
5.5.1 "Foam-On Tile"is limited to use of the following Approved tile ahesives underlayment combinations.
TABLE IA:ALLOWABLE TILE ADHESIVE/UNDER141 YMENT COMBINATIONS'
F_
Adhesive Florida Product
Approval Underlayments
DAP Foam Touch'n Sea[StormBond Roof
Tile Adhesive FL14506 Polystick TU Plu ,Polystick TU Max
Dow TileBondTm FL22525 Polystick TU P,P lystick TU Plus,Polyflex SAP or Tile Pro
Polystick TU P,P I lystick TU Plus,Polystick TU Max,Polystick Tile Pro,
JCP Adhesives Polyset'O AH-160
FL6332 Elastoflex G TU,ElastoflexS6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR,
Mule-Hide SA-A�,,P Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
Polystick TU P.P61ystick TU Plus,Polystick TU Max,Polystick Tile Pro,
ICP Adhesives Polyset"RTA-1 FL6276 Elastoflex G TU, lastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR,
I Mule-Hide SA-A ,P Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
Polyglass PolyLok Roof Tile Adhesive FL17855 Polystick TU Plui or Polystick TU Max
Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVH12 EVAL ATION FL5259-R27
Polyglass Roof Underlayments;(570)38 -1230 Revision 23:09/14/2017
Page 5 of 14
TRUNIFY, E.RD
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Polystick(all variations),Dual Pro,Tile Pro,Polyflex SAP or SAP F
Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR)self-adhered to:
> New untreated plywood;ASTM D41 primed new untreated plywood; Existing plywood;ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 prim d OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concre e; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note: Polygloss does not require priming of new or existing ply ood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to app)-cation of Polystick membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphal to:
> ASTM D41 primed structural concrete.
Pblyflex G or Polyflex G FR torch-applied to:
> ASTM D41 primed structural concrete.
5.6.2 Bond-to-Insulation.
Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-A P Cap Sheet or SA-APP Cap Sheet(FR) self-adhered
to:
> ASTM C1289, Type 11, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard;Dens Deck Prime;or SECURCICK Gypsum-Fiber Ro(f Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphal-to:
> Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
Polyflex G or Polyflex G FR torch-applied to:
>
ASTM D41 primed structural concrete;Dens Deck Prime or SEJROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof co�erings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems, insulation attachment shall be designed by a qualified
the insulation/underlayment system in accordance with FBC Sect design professional and installed based on testing of
on 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Layer:
Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA- �PP Cap Sheet or SA-APP Cap Sheet(FR) Dual Pro or
Tile Pro self-adhered to:
> ASTM D226,Type I or 11 felt;Elastobase;Elastobase P or Mule- ide Nail Base.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphal to,
> ASTM D226,Type I or 11 felt;Elastobase;Elastobase P,Mule-Hi e Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch-applied to:
> Elastobase;Elastobase P,Mule-Hide Nail Base,Polyglass G2 B se or Po,lyglass APP Base.
For installations under mechanically attached prepared roof co erings, base layer shall be attached per minimum
codified requirements. For installations under foam-on the s stems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12),Appendix A,Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
Exterior Research and Design,LLr_ Evaluation Report P12060.02.09-R73
Certificate ofAuthorization#.9503 EDITION(2017)FSC NON-HVHZ EVAL ATION FL5259-R27
Polyglass Roof Underlayments,(570)38 1230 Revision 23:09/1412017
Page 6 of 14
5.6.4 Wind Resistance for Underlayment 5 stems in Foam-On Tile A lications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment
forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012(04.-12) and are used in foam-on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wi I d loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
12),Appendix A,Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements t 3 satisfaction of Authority Having Jurisdiction.
Primer: None
Underlayment: Polystick TU P,Polystick TU Plus, Polystick TU Max,Polyf ex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#2 Maximum Design Pressure=-97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements t satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyflex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x
1%"ring shank nails through 32 ga.,1-5/8"diameter tin c aps spaced 12-inch o.c.
#3 Maximum Design Pressure=-105 DO:
Deck: Min.15/32-inch plywood to meet project requirements t D satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyf ex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and.
Mule-Hide SA-APP Cap Sheet(FR),self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x
1Y4"ring shank nails through 32 ga.,1-5/8"diameter tin aps spaced 12-inch o.c.
#4 Maximum Design Pressure=-135 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)PG100 or ASTM D41
Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywoo joints.
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyf lex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#5 Maximum Design Pressure=-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max,Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap
Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhere J.
#6 Maximum Design Pressure=-622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full moppin of hot asphalt or Polyflex G,torch-applied.
#7 Maximum Design Pressure=-30.0 psf*:
Deck: Min.15/32-inch OSB to meet project requirements to sa isfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-Inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Pol ex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#8 Maximum Design Pressure=-37.5 psf*:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at wo(2)equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Poll ex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALU AXION FL5259-RZ7
Polyglass Roof Underlayments;(570)38 1230 Revision 23:09/14/2017
Page 7of14
TRNi1a ( ER
#9 Maximum Design Pressure=-37.5 psf*:
Deck: Min.19/32-inch plywood to meet project requirements t satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round met 31 cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt.
#10 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements t satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)layer ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring hank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Polyfiex SAP,Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elastoflex G TU,applied in full mopping of hot asphalt.
#11 Maximum Design Pressure=-45 psf*:
Deck: Min.19/32-inch plywood to meet project requirements t satisfaction of Authority Having Jurisdiction.
Base Sheet: Two(2)layers ASTM D226,Type It felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular Ing shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at Iwo(2)equally spaced staggered center rows.
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Poly ex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered or Elast flex G TU or Elastoflex S6 G,applied in full mopping of hot
asphalt.
#12 Maximum Design Pressure=-45 psf:
Deck: Min.15/32-inch plywood to meet project requirements o satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-z pplied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MARX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#13 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements o satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-z pplied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#14 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at our(4)equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Pol lex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#15 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirementso satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-pplied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at our(4)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full moppin of hot asphalt or Polyflex G,torch-applied.
#16 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch- pplied cap or poly-film surface for torch-applied cap)
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full moppin of hot asphalt or Polyflex G,torch-applied.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R23
Certificate of Authorization✓19503 6T"EDITION(2017)FBC NON-HVHZ EVALL ATION FL5259-R27
Polyglass Roof Underlayments;(570)38 -1230 Revision 23:09/14/2017
Page 8of14
/
#17 Maximum Design Pressure -60 psi:
� plywoodproject —ir_—nts U satisfaction of Authority Having Jurisdiction._
Spacing:Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-a plied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip with CMG Flat Bottom Meta Plates
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c. two(2)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#18 Maximum Design Pressure=-67.S psf.
Deck: Min.15/32-inch plywood to meet project requirements t satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of t rch-applied underlayment)
Fasteners. 12 ga.x 1.25-inch long x 3/84nch head diameter annular ing shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-Inch o.c.at the 4-inch wide side laps and 8-inch o.c.at
. ur(4)equally spaced staggered center rows.
Underlayment:Elastoflex G TU or Elastoflex S6 G, applied in full mop ing of hot asphalt or torch-applied or Polyflex G, torch
#19 Maximum Design Pressure=-75 psf:
D*eck: Min.15/32-inch plywood to meet project requirementst satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base(requires use of rch-appliedunderloyment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
side and-- _—
'applied—_—_-_
TMINTf ERID
#24 Maximum Design Pressure=-97.5 p
Deck: Min.19/32-inch plywood to meet project requirements tsatisfaction of Authority Having Jurisdiction.
B ase Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
p
�
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring hank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-Inch o.c.at the 4-inch wide side laps and 4-inch o.c.at our(4)equally spaced staggered center rows.
Underlayment:Polystick TU P,Polystick TU Plus,Polystick TU Max,Pol ex SAP,Polyflex SAP FR,Mule-Hide SA-APP Cap Sheet and
Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
#25 Maximum Design Pressure=-105 p
Deck: Min.15/32-inch plywood to meet project requirements �o satisfaction of Authority Having Jurisdiction.
-
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch- cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at hree(3)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Eiastoflex S6 G,applied in full moppin of hot asphalt or Polyflex G,torch-applied.
#26 Maximum Design Pressure=-120 psf,
Deck: Min.15/32-inch plywood to meet project requirements o satisfaction of Authority Having Jurisdiction.
's
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-with
cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty w h OMG 3"Round Metal Plates or OMG Flat Bottom Metal
Plates -
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at ive(5)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full moppin of hot asphalt or Polyflex G,torch-applied.
#27 Maximum Design Pressure=-120 psf:
Deck: Min.15/32-inch plywood to meet project requirements o satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast'#14 HD with Trufast 3"Metal I sulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 15-inch o.c.at ive(5)equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 6,applied in full moppin of hot asphalt.
5.6.4.1 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of-45 psf,
5.6.4.2 For mechanically attached Base Sheet,the maximum design pre sure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012(04-12),Appendix A,Ta le 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone I design
pressure determined-in accordance with FBC 1609. In this casq, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the eleva-ed pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-:29 and Rooflill;Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2. b.1 of FM Loss Prevention Data Sheet 1-29 (January
2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP B se shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for lo ger than 90-days after installation.
Polystick MTS,TU P,TU Plus,TU Max, Dual Pro,Tile Pro or Elas,oflex G TU shall not be left exposed for longer than
180-days after installation.
Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or A-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive-set tile (Elastoflex SE G or Polyflex G only), in which case the maximum
exposure is 180,days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition,tested at standard laboratory con itions. Agreement between purchaser and seller,as
set forth in Section 4.3, Note I of ASTM D1970-15,should be est blished as to slip resistance.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 EDITION(2017)FBC NON-HVHZ EVAL ATION FL5259-R27
Polyglass Roof Underlayments;(570)38 1-1230 Revision 23:09/14/2017
Page 10 of 14
E R DD
5.9 Tile Slippage Limitations(TAS 103 Per RIA pril 2012(04-121):
When loading roof tiles on the underlayment in direct-deck tileassemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using b ttens during loading of the roof tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DiREcr-DEcK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method MaArrium Slope
Flat 10-tile stack 7:12
Elastoflex G TU Lugged -tile stack(6 aver 2) 6:12
Elastoflex 56 G or S6 G FR Flat or Lugged 0-tile stack(4 over 2) 4:12
Polystick MTS Flat or Lugged Prohibited without battens N/A
Polystick Tile Pro Flat or Lugged 5-tile stack(4 over 2) 7:12
Flat 6-tile stqck(4 over 2)or 10-tile stack 7:3.2
Polystick TU Max Lugged 0-tile stack(4 over 2) 7:12
Lugged 10-tile stack 6:12
Polystick TU P Flat 5-tile stack(4 over 2) 6:12
Lugged i-tile stack(4 over 2) 4:12
Flat or Lugged i-tile stack(4 over 2) 7:12
Polystick TO Plus Flat or Lugged 10-tile stack 6:12
Polyflex G or G FR Flat or Lugged 5-tile stack(4 over 2) 4:12
Polyflex SA P or SA P FR Flat or Lugged 4:12
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Pollyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the sp Bcifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nal heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Elastobase,Elastobase P or Mule-Hide Mail Base:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226,Type 11 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase,Elastobase P or Mule-Hide Nall Base may be cover E d with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self-adhered, Elastoflex G TU, Elastoflex SIS G or
Elastoflex S6 6 FR in hot asphalt or Polyflex G or Polyflex 6 FR,torch applied. Roof cover limitations are those are
those associated with the top-layer underlayment,as set forth in Table 1.
6.3.2 file Applications:
Elastobase,Elastobase P or Mule-Hide Nall Base are limited to L se as a mechanically attached base sheet in the"Two
Ply System"from FRSA/TRI April 2012(04-12). Reference is made to Table I and Section 5.6.4 herein,coupled with
FRSA/TRI April 2012(04-12)Installation Manual.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 EDITION(2017)FBC NON-HVHZ EVAL ATION FL5259-R27
Pollyglass Roof Underlayments,(570)38 1230 Revision 23:09/14/2017
Page 11 of 14
11 RNy ERR
6.5 Elastofleic G TU,Elastoflex SG G or Elastoflex S6 G FR:
6.5.1 Elastoflex G TU,Elastoflex 56 G or Elastoflex S6 G FR shall be ins ailed in compliance with current Polyglass published
installation requirements. For use in tile applications:
V Elastoflex G.TU is for use as an alternate to "Mineral Surfac Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System"from FRSA/TRl April 2012(04-12)beneath mech nically fastened the roof systems or the Hot Asphalt
applied"Cap Sheet" in the"Two Ply System"from FRSAITRI ins
2012(04-12) beneath mechanically fastened or
adhered tile roof systems.
v/ Elastoflex S6 G is for use as an alternate to"Mineral Surface 11 Roofing"(ASTM D6380,Class M)in the"Single Ply
System" from FRSA/TRl April 2012 (04-12) beneath mec a ically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System"from FRSA/TRl Aril 2012(04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FIR is for use as an alternate to"Mineral Surfa e Roll Roofing"(ASTM D6380,Class M)in the"Single
Ply System"from FRSA/TRl April 2012(04-12) beneath mech nically fastened tile roof systems or the Hot Asphalt
applied"Cap Sheet"in the"Two Ply System"from FRSA/TRl pril 2012(04-12)beneath mechanically fastened the
roof systems.
6.5.2 For hot-asphalt-applications,Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt-applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end-laps minimum 6-inch wide, off-set
minimum 3 feet from course to course. Side and,end laps shall b fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap e ge.
6.6 Polyflex G or Polyflex 6 FIR:
6.6.1 PolVflexG or Polyflex G FR shall be installed in compliance with urrent Polyglass published installation requirements.
For use in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied"Cap Sheet" in the"Two Ply System"from FRSA/TRl April
2012(04-12.)beneath mechanically fastened or adhered tile r of systems(Base Sheet Limited per 5.6.3).
✓ Polyflex G FIR is for use as an alternate to the Heat Applied Cap Sheet" in the "Two Ply System"from FIRSA/TRI
April 2012(04-12)beneath mechanically fastened tile roof sy tems(Base Sheet Limited per 5.6.3).
6.6.2 Polyflex G or Polyflex G FIR shall be fully torch-applied to the substrates noted in Section 5.6. Side laps shall be
i
minimum 3-inch and end-laps minimum 6-inch wide, off-set m nimurn 3 feet from course to course. Side and end
laps shall be fully heat-welded and inspected to ensure minimu 3/8-inch flow of modified compound beyond the lap
edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile sli page and/or damage to the underlayment. Refer to
Table 2 herein,and Polyglass published requirements for tile staing.
6.7.2 Battens and/or Counter-battens,as required by the should
manufa fturer and FRSA/TRI April 2012(04-12)must be used
t I
on all roof slopes greater than 7:12. Precautions be t ken as needed, such as the use of battens or sail-
boards, e t
boards,to prevent the sliding and/or damage to the underlayme t during the loading process.
6.7.3 Polyglass specifies the minimum cure time after installation of self-adhering membranes and before loading of
roofing tiles is forty-eight(48)hours.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R23
Certificate ofAuthorization#9503 GTH EDITION(2017)FBC NON-HVHZ EVAL ATION FL5259-R27
Polyglass Roof Underfayments;(570)3 3.230 Revision 23:09/14/2017
Page 13 of 14
ITRNRY ERE,
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in orde to properly evaluate the installation of this product.
B. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covere for F.A.C.61620-3 QA requirements. The following
plants have qualified products under their respective physical properties s ecifications.
Plant roduct s
Fernley,NV,Hazleton,PA&Winter Haven,FL ASTM D1970 I olystick MU-X
Hazleton,PA M-D 13-0004 1 lastoflex G TU
ASTM D1970 I olystick IR-Xe
Hazleton,PA&Winter Haven,FL ASTM D1970&TAS 103 olystick TU Plus
ASTM D1970&TAS 103 olystick TU Max
Tuscaloosa,AL ASTM D4601,Type II olyglass G2 Base
ASTM D226(physicals) lastobase,Elastobase P
ASTM D6509 olyglass APP Base
TAS 103 olystick MTS
ASTM D1970&TAS 103 Polystick TU P
Winter Haven,FL FRSA/TRI April 2012 Polyflex SAP,Polyflex SA P FR
ASTM D1970 Polystick Dual Pro
ASTM D1970&TAS 103 olystick Tile Pro
ASTM D6164 lastoflex S6,Elastoflex S6 G FR
ASTM D6222 lolyflex G,Polyflex G FR
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625; (314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R23
Certificate of Authorization#9503 6'"EDITION(2017)FBC NOM-HVHZ EVAL ATION FL5259-R27
Polyglass Roof Underlayments;(570)384-1230 Revision 23:09/14/2017