Loading...
HomeMy WebLinkAboutBuilding Permit Application (5) ginaft M IAM!DADE 11'1! 04f MIAMI-DADE COUNTY 011,14t 41146r1 PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) *40 Cie% Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION Lifi, ;6)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) • www.miluniclade.govieeonomy PGT Industries,Inc. 1070 Technology Drive, North Venice,Fl.34275 -1=7 - -SCPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(A1-1.1). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "5470" Vinyl Sliding Glass Door(Reinforced)-N.I. APPROVAL DOCUMENT: Drawing No. SGD-5470,titled"Vinyl Sliding Glass Door NOA (NI)", sheets 1 through 21 of'21, prepared by manufacturer,dated 10/05/15,with Revision A dated 04/05/17, signed and sealed by Anthony L. Miller,P.E.,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING: None: Approved Hurricane Protection devices,complying w/FBC,as applicable are required. - - = LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and series and -- - following statement: "Miami-Dade County Product Control Approved",noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#15-1210.02 and consists of this page 1, and evidence pages E-1 &E-2,as well as approval it document mentioned above. The submitted documentation was reviewed by Jorge M.Plasencia,P.E. TAV41tik-. 2. NOA No. 17-0420.07 MIAMIDADE COUNTY": APPRO DIV=11W45 / I I Expiration Date: April 21,2021 0'11111v-1 Approval Date: September 28,2017 Page 1 • , 4 . , - - •-• • PGT Industries,Inc. • NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. ----•-••-7DRAWINGS - 1. Manufacturer's die drawings and sections. • (Submitted under NOA No. 11-0107.09) 2. Drawing No. SGD-5470;titled"Vinyl Sliding Glass-Door NOA (NI)", sheets.1 through--2-1-of 21,prepared by manufacturer, dated 10/05/15,with Revision A dated 04/05/17, Signed and sealed•by Anthony L.-Miller,P.E. B. —-TESTS 1. Test report on -1)Air Infiltration Test,per FBC,TAS 202-94 - 2)Uniform Static Air Pressure Test,per FBC,TAS 202-94 • 3) Water Resistance Test,per FBC, TAS 202-94. .4)Forced Entry Test,per FBC, TAS 202-94 . ••• • - • -• - along with marked-up.drawings and installation diagram-of vinyl sliding glass,door,prepared by • - - Fenestration Testing Lab, Inc.,-Test Report No. FTL 6637(samples A-1-thru A-5);dated 11/19/10 • -signed and sealed by Jorge A. Causo,P:E. under NOAJNO.-'11-0107.09) 2. Additional test report No. FTL 6638 (samples A-1 thru A-22)per-TAS 201/203-94,issued by ' • • : Fenestration Testing Lab, mc, dated 11/19/10, signed and sealed by Jorge A. Causo,-P.E. --- (Subniiiied under NOA No. 11-0107.04) • . - - -- 3. Additional test report No. FTL 8717,issued by Fenestration Testing Lab, Inc., dated 12/07/15, . .•:•-_. .revised:on-02/15/16 and 02/24/16, signed and sealed by Idalmis-Ortega,-P.-E. •,• • • (Submitted under NOX-NO.'7s4210.01) . . . . -- .4. - Additional test report No.FTL 8546 issued by Fenestration Testing Lab,Inc', dated 11/06/15, revised on 01/04/16 and 02/11/16,signed and sealed by Idalmis Ortega,P. E . - •- (Submitted'under-NOANo.. 154210.01) 5. --Additional test repOrt No. FTL 8547 issued by Fenestration Testing Lab, Inc., dated 12/04/15, . _. revised on 02/15/16, signed and sealed by Idalmis Ortega,P. E. • • - ' (Submitted,under NOA No.-15-1210.01) test report No. FTL 8548 issued by Fenestration Testing Lab, Inc.; dated 12/04/15, revised on 01/04/16 and 02/11/16,signed and sealed by Idalmis Ortega,P. E., • (Submitted under NOA No. 15-1210.01) .7„-Additional•test report_No:,FTL 8549 issued by Fenestration Testing Lab,.Inc., dated 12/04/15,. . _ revised on 12/04/15 and 02/11/16,.signed and sealed by Idalmis Ortega,P. E. - No.-35-121 01) test report No- FTL 8552 issued bYFenestration Testing Lab, Inc., dated 12/04/15, revised on 02/15/16, signed and sealed by Idalmis Ortega,P. E. • (Submittedunder,NOA No;--15-1210.01) . C. CALCULATIONS. - 1. Anchor verification calculations and structural analysis, complying with FBC-2014,preparedby PGT, dated 12/09/15 and last revised on 02/15/16, signed and sealed by Anthony L. Miller, P.E. (Submitted under NOA No. 15-1210.02) • Jorge M.Plasencia,P.E. Product Control Unit Supervisor NOA No. 17-0420.07 • Expiration Date: April 21,2021 Approval Date: September 28,2017 • E-1