HomeMy WebLinkAboutPRODUCT APPROVAL (3) EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization#9503
N STREET,UNIT#13
TRINITY ERD 353 CHRISTIAOXFORD,CT 6478,
203 262-9245
EVALUATION REPORT
GAF Evaluation Report 01506.01.08-1122
1 Campus Drive FL10124-1120
Parsippany,NJ 07054 Date of Issuance:01/03/2008
(800)766-3411 Revision 22:09/20/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applica le rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume: The
products described herein have been evaluated for compliance,with the 61h Edition (2017) Florida Building Code
sections'noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes a reement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentati n changes. Trinity)ERD requires a complete
review of this Evaluation Report relative to updated Code requirement with each Code Cycle.
ADVERTISEMENT:.The Evaluation Report number preceded by the wor s "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is display d,then it shall be done in its entirety.
INSPECTION:.Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at thE request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by: 3-ttt,t,,!
.13 r
-? *=
:10..-SNA
Robert J.M.Nieminen P.E. s `
> >>� JiOtaLq}s`�"'. The facsimile seal appearing was authorized by Robert Nleminen, .
Florida Registration No.59166,Florida DCA ANE1983 t'' P.E.on 09/20/2017.This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity I ERD.does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity l ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in a iy company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in-any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY I ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance-Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
following sections.of the 6u' Edition (2017) Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Comr Hance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4/1507.1.1, Physical Properties ASTM D:.970 2015
R905.2.3/R905.1.1
1507.2.5,R905.2.4 Physical Properties ASTM D 462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D 161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D"158 2011
1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
Entity Examination Referei ce Date
GAF(PDM 1915) Letter of Equivalency SealSeal�dge Impact Resistant IR 01/13/2012
PRI(TST 5878) Physical Properties GAF-02 -02-01 03/27/2002
PRI(TST 5878) ASTM D3462 GAF-05 -02-01 09/02/2004
PRI(TST 5878)• ASTM D3462 GAF-08 -02-01 05/25/2005
PRI(TST 5878) Physical Properties GAF-32 -02-01 12/01/2011
PRI(TST 5878) Wind Driven Rain GAF-40 -02-01 01/21/2013
UL(TST 1740) ASTM D3462 93NK62 35 11/29/1993
UL(TST 1740) ASTM D3462 99NK43 335 01/12/2000
UL(TST 1740) TAS 107 94NK96 2 03/29/2000
UL(TST 1740) ASTM D3462 O1NK06 532 02/02/2001
UL(TST 1740) ASTM D3161,TAS 107 O1NK92 6 05/21/2001
UL(TST 1740) ASTM D3161 01NK37 22 12/18/2001
UL(TST 1740) ASTM D3462 01NK37 22 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12 180 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30 71 09/09/2002
UL(TST 1740) ASTM D3161 03CA53 7 03/11/2003
UL(TST 1740) ASTM D3462 03NK26 44 10/17/2003
UL(TST 1740) ASTM D3462 04NK13 50 06/07/2004
UL(TST 1740) ASTM D3161 04NK13 50 06/23/2004
UL(TST 1740) ASTM D3161 04NK30 46 03/10/2005
UL(TST 1740) ASTM D3462 04NK22 09 05/06/2005
UL(TST 1740) ASTM D3161 04NK22 09 05/09/2005
UL(TST 1740) ASTM D3462 05NK27 24 02/10/2006
UL(TST 1740) ASTM D3161 OSNK27 24 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18 77 06/05/2006
UL(TST 1740) ASTM D3161,D3462 06CA18 74 06/16/2006
UL(TST 1740) ASTM.D3161,D3462 06CA35 51 10/18/2006
UL(TST 1740) ASTM D3462 06CA31 03 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41 95 12/27/2006
UL(TST 1740) ASTM D3161 07NK05 28 03/13/2007
UL(TST 1740) ASTM D3161 06CA31 11 04/04/2007
UL(TST 1740) ASTM D3161 06CA61 48 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31 42 11/08/2007
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06 00 03/13/2008
Exterior Research and Design,I.I.C. Evaluation Report.01506.01.08-1122
Certificate of Authorization 119503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10124-1120
GAF Asphalt Roof Shingles Revision 22:09/20/2017.
Page 2 of 6
i
TRINITY I ERD
Entity Examination Refere Ce Date
UL(TST 1740) ASTM D3161,D3462 07CA55 08 04/01/2008
UL(TST 1740) ASTM D3161,D3462 09CA10 92 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06 56 05/15/2009
VL(TST 1740) ASTM D3161,D7158,D3462 09NK06 147 08/01/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09CA27 81 08/27/2009
.UL(TST 1740) ASTM D3161,D7158,D3462 IOCA35 54 03/05/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10CA13 86 05/15/2010
UL(TST 1740) ASTM D3462 10CA07 64 05/27/2010
UL(TST 1740) ASTM D3462 10CA11 53 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11 151 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK12 170 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06 00 01/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462+ 10CA53 34 03/31/2011
Ul.(TST 1740) ASTM D3161,D7158,D3462 11CA48 24 10/22/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA47 19 12/03/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48 08 12/08/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48 25 12/09/2011
UL,LLC.(TST 9628) ASTM D3462 12CA34 91 10/12/2012
UL,LLC.,(TST 9628) ASTM D3161,D7158,D3462 12CA58 51 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38 83 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32 32 06/18/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37 34 08/02/2013
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 478687 675 07/17/2015
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 478743 542 05/17/2016
UL,LLC.(QUA 9625) Quality Control Inspecti n Report,R21,Mobile,AL 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspecti n Report,R21,Myerstown,PA 10/20/2016
UL,LLC.(QUA 9625) Quality Control Inspecti n Report,R21,Tuscaloosa,AL 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspecti n Report,R21,Michigan Cty,IN 11/01/2016
UL,LLC.(QUA 9625) Quality Control Inspecti 3n Report,R21,Shafter,CA 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspecti n Report,R21,Savannah,GA 11/11/2016
UL,I.I.C.(QUA 9625) Quality Control Inspecti n Report,R21,Minneapolis,MN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspecti n Report,R21,Mt.Vernon,IN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspecti n Report,R21,Baltimore,MD 10/21/2016
UL,I.I.C.(QUA 9625) Quality Control Inspecti n Report,R21,Tampa,FL 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspecti3n Report,R21,Dallas,TX .11/04/2016
UL,LLC.(QUA 9625) Quality Control Inspecti 3n Report,R21,Ennis,TX 11/03/2016
UL,LLC.(QUA 9625) Quality Control Inspecti n Report,R21,Fontana,CA 11/01/2016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel' are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot®, Camelot® II, Fortitude'", Glenwood TM, Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR,
Grand Sequoia® ArmorShield'', Monaco®, Sienna®, Timberline® American Harvest®, Timberline®
ArmorShieldT" II,Timberline® Natural Shadow®,Timberline HD®,Timberline®Cool Series®,Timberline Ultra
HD®and Woodland®are fiberglass reinforced,laminated sphalt roof shingles.
4.1.3 Slateline®is a fiberglass reinforced 5-tab asphalt roof shin 7.1e.
4.2 Hip&Ridge Shingles:
4.2.1 Seal-A-Ridge® Ridge Cap Shingles, Seal-A-Ridge® IR Im act-Resistant Ridge Cap Shingles, Seal-A-Ridge®
ArmorShield"I Ridge Cap Shingles and Timbertex®Premiu TI Ridge Cap Shingles are fiberglass reinforced,hip
and ridge asphalt roof shingles.
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R22
Certificate ofAuthorization#9S03 6T"EDITION(2017)FBC NON-HVHZ EVA UATION FL10124-R20
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 3 of 6
TRINITY I ERD
4.3 Accessory Starter Strips:
4:3.1 Pro-Start® Eave/Rake Starter Strip Shingles and WeatherBl ckerl Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-s rfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen starter strip, nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6-
inch or less.
4.3.3 StarterMatchTM Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon® and
Grand Sequoia® series asphalt shingles. StarterMatchT are installed as the second starter for Grand
Canyon®and Grand Sequoia®series installations.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity)ERD or Robert Nieminen, P.E. are, in any way,.the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained spe ifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
ns.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classifi d in.accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158, :1'ass H, indicating the shingles are acceptable for
use in all wind zones up to Vasd=150 mph(V„It=194 mph . Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are CIE ssified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F, indicating the sh ngles are acceptable for use in all wind zones up
to Vasd=150 mph(VuIt=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158,applies only to,exposure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by 3 qualified design professional are required for
conditions outside these limitations. Contact the shingle ianufacturer for data specific to each shingle.
5.5 All products in the roof assembly shall have quality assura ce audit in accordance with F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally Approved per Rule 61G20-3,per FBC 1507.2.3,15 7.2.4 or R905.2.3.
6.2 Starter Shingles or Starter Strip:
6.2.1 Installation of Pro-Start Eave/Rake Starter Strip Shingles,WeatherBlocker Premium Eave/Rake Starter Strip
Shingles and QuickStart Peel&Stick Starter Roll shall con iply with the GAF current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the GAF urrent published instructions, using minimum four
(4)nails per shingle in accordance with FBC 1507.2.7 or M 05.2.6,with the following exceptions:
➢ Camelot, Camelot II, Grand Canyon, Grand Sequoi , Grand Sequoia IR, Grand Sequoia ArmorShield,
and Woodland require minimum five(5)nails per sh ngle.
➢ Slateline requires minimum six(6)nails per shingle.
6.3.2 Fasteners shall be in accordance with manufacturer's pub ished requirements,but not less than FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 t nits horizontal; special methods of fastening are
required. Contact the GAF for details.
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1122
Certificate of Authorirotion#9503 6T"EDITION(2017)FBC NON-HVHZ EVA UATION F1.30124-1120
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 4 of 6
F)o
TRINITY I ERD
6.4 Hip&Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles, Seal-A-R dge IR Impact-Resistant Ridge Cap Shingles and
Seal-A-Ridge ArmorShield Ridge Cap Shingles shall comp)1 with the GAF current published instructions with
a minimum two (2) nails, minimum 3/8-inch head diam ter, per shingle and nominal 0.25-inch diameter
beads of Henkel"Loctite PL S30 Roof&Flashing Sealant".
11.5" Sealant
1^ (292 mm) 1° Sellante
(25 MM) (25 rn Enduit d'etanchei e
1iNail
12"Nii (305 mm)
Clavo
6 5/8' 7 5/8° Clouer
(168-194 MM)
12"
(305 mm)
6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions
with a minimum two.(2) nails, minimum 3/8-inch head d ameter, per shingle and beads of Sonneborn NP1
Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
1U5' ealatsi
1;---(2-52 rni:tiy 1:" �Sallanlo
(25 MIrN) (25 rntzi �aduit�!'�tan esiR1
ra i
Nan tM
Mum f�@4u (305 41-M)
C Mmli
(315 mmt)
6.4.3 'Fasteners shall be in accordance with GAF published iequirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R22
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVA MANION FL10124-R20
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 5 of 6
i
TRINITY I ERD
7. LABELING:
7.1 Labeling shall be in accordance with the requirements he Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with c ne of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdictio i in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants prod ice products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(847)664-3281
END OF EVALUATION REP JRT-
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-1122
Certificate of Authorization 119503 6T"EDITION(2017)FBC NON-HVHZ EVA DATION FL10124-R20
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 6 of 6