Loading...
HomeMy WebLinkAboutWind Load Calculation A .+ , 1SE.AD ; '.,. r. Jin° .. .. "Building Our Quality Reputation One .Qustomer At A Time SCC131150472 Property Information Building Infonnation Owner: ROSANNE SANCHEZ Wind Zone. 165 MPH. Address: 119 QUEEN EUGENIA CT Exposure Category: D FORT PIERCE,FL 34949 Minimum Building Dimension: 40 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations �OpeningLocation Device Device Device Max Positive ;i Max Negative I Number Zone Width(in) Height(in) IL ILlevation(ft) Pressure(psf)j Pressure(psf) j 1 Int 97 81 7 38.4 -42.1 2 Int 33 81 7 41.5 -45.1 —..__.................--.........._..----- - ...-.................r --................._.-......- _.............................. -- ...........__ .._..............----- _..-....._._ 3 End 25 60 7 43.1 -57.6 4 Int 25 60 7 43.1 -46.8 ----...-.-- -- -- 5 Int 25 60 7 4 3.1 -46.8 i --.. -... --- --- --...- -- -.... -.......................------ ------....................... - --- -- 6 Int 93 57 7 39.6 -43.2 ......... _ -- - ------- - 7 End 93 56 7 39.6 -50.6 ,Y` ILE CO!80RECEIVED JUN 2 8 2018 ST. Lucie County, Permitting Prepared in accordance ivilh:ASCE 7-10,Chapter 30. Wind Loady-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1. of 1 A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING MULLION SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS REQ YIN SIZE REQ Y/N/NA 1 Int Door 1"Lami IG FL 15210.6 50 50 38.4 -42.1. 152 x 8' 97x81. No No 2 Int Door I"Lami IG FL15210.4 75 75 41.5 -45.1 37.5 x 81 33x81 No No 3 End Window 7/8"Lami FL4091.2 67.5 67.5 43.1 -57.6 52x71 25x60 No No 4 Int Window 7/8"Lami FL4091.2 67.5 67.5 43.1 -46.8 5201 25x60 No No 5 Int Window 7/8"Lami FL4091..2 67.5 67.5 43.1 -46.8 5201 25x60 No No 6 Int Window 7/8"Lami'G FL16736.2 60 60 39.6 -43.2 "'x fi3 93x57 No No 7 End Window 718"Lami IG FL16736.2 60 60 39.6 -50.6 111 x 63 93x56 No No RECEA ED nv 9 1 � CU(. tI4 ....i� to