Date: 6/29/18 Permit Number:
w
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue,Fort Pierce FL 34982
Phone: (772)462-1553 Fax:(772)462-1578 Commercial Residential X
PERMIT APPLICATION FOR: Plumbing VIA
Address: 9600 S OCEAN DR#604
Legal Description: EMPRESS CONDOMINIUM UNIT 604
Property Tax ID#: 4502-620-0040-000-9 Lot No.
Site Plan Name: Block No.
Project Name:
Setbacks Front Back: Right Side: Left Side:
REPLACEMENT OF 50 GALLON ELECTRIC WATER HEATER
RAdWditionallRworkto anertormed under this permit—check all apply:
11HVAC 11 Gas Tank E]Gas Piping _Shutters a Windows/Doors
11 Electric RI Plumbing []Sprinklers Generator Roof Roof pitch
Total Sq. Ft of Construction: S . Ft.of First Floor:
Cost of Construction:$ 1450.00 Utilities: Sewer El Septic Building Height:
Name HOWARD LEVY Name: RICHARD BASSOFF
Address:9600 S OCEAN DR#604 Company: ADMIRAL PLUMBING SVCS, LLC
City: JENSEN BEACH State: Address: 2895 JUPITER PARK DR#700
Zip Code: 34957 Fax: City: JUPITER State:FL
Phone No.772-229-9718 Zip Code: 33458 Fax: 561-744-7101
E-Mail: Phone No. 561-746-1180
Fill in fee simple Title Holder on next page(if different E-Mail: THEADMIRALPLUMBER@GMAIL.COM
from the Owner listed above) State or County License: CFC 1426115
If value of construction is$2500 or more,a RECORDED Notice of Commencement is required.
DESIGNER/ENGINEER: x Not Applicable MORTGAGE COMPANY: Not Applicable
Name: Name:
Address: Address:
City: State: City: State:
Zip: Phone Zip: Phone:
FEE SIMPLE TITLE HOLDER: Not Applicable BONDING COMPANY: Not Applicable
Name: Name:
Address: Address:
City: City:
Zip: Phone: Zip: Phone:
OWNER/CONTRACTOR AFFIDVIT:Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St.Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules,bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit,I do hereby agree that I will,in all respects,perform the work
in accordance with the approved plans,the Florida Building Codes and St.Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review:room additions,
accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use
WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property.A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing, consult with lender or an attorney before
commencing work or recording our NoticDqJ Commencement.
Signa a of Owner/Lessee/Co ractor A nt for Owner Signature of Contractor/Lice ns older
STATE OF FLORIDA STATE OF FLORIDA
COUNTY OFPALMBEACH COUNTY OFPALM BEACH
The forgoing instrument was acknowledged before me The forgoing instrument was acknowledged before me
this 29TH day of JUNE ,201k by this 29TH day of JWVE ,20 19 by
RICHARD BASSOFF RICHARD BASSOFF
Name of person making statement Name of person making statement
Personally Known x OR Produced Identification Personally Known x OR Produced Identification
Type of Identification Type of I entification
Produced Produc
oigna e of Notary Public-State of Florida) (S gnat of Nab �Ipf- ,of Florida)
C mis on No. ��` �FER.C4,S,��i,,(Seal) Com on I��. ,0-30•?0� . •�O (Seal)
•�`��ti o�'N'.�o-i N 0���� = N O TA R
REVIEWS FRQNTP U B YONING z SUPERVISOR PLANS AG_ �• A j�7RTLE MANGROVE
C�UA REVIEW REVIEW l �001i REVIEW
DATE oF,.1-091,0`���` ���►1�tiit�►t���
RECEIVED
DATE
COMPLETED
Rev.8/2/17
I
Michelle Franklin, CFA-- Saint Lucie County Property Appraiser--All rights reserved.
Property Identification
Site Address: 9600 S OCEAN DR 604
Parcel ID: 4502-620-0040-000-9
Account#: 125687
Map ID: 45/02N
Use Type: 0400
Zoning:
City/County: Saint Lucie County
Ownership
Total Areas
Iloward B Levy
Rochelle L Levy Finished/Under Air(SF):
9600 S Ocean Dr#604 Gross Area(SF):
Jensen Beach,FL 34957
Land Size(acres):
Legal Description Land Size(SF):
IMPRESS CONDOMINIUM UNIT 604(Olt 1285-1888)
Current Values
Just/Market Value: $263,200
Assessed Value: $225,928
Exemptions: $50.000
Taxable Value: $175.928
Taxes for this parcel: SLC Tax Collector's Oil-ice 12
Download TRIM for this parcel:Download PDF 12
This information is believed to be correct at this time but it is subject to change and is not warranted.
(0 Copyright 2018 Saint Lucie County Property Appraiser.All rights reserved.
I
Admiral Plumbing Services,LLC Invoice 170142
PLUMBING SERVICES 2895 Jupiter Park DR#700 Invoice Date 6/27/2018
Jupiter,FL 33458 Terms COD
561-746-1180 Completed Date 6/27/2018
License:CFC 1426115
Customer PO
Billing Address Job Address
HOWARD LEVY HOWARD LEVY
9600 South Ocean Drive#604 9600 South Ocean Drive#604
Jensen Beach,FL 34957 USA Jensen Beach,FL 34957 USA
Description of Work
Invoice 170142 installed 50 gal heater with pan,ball valve,electric upgrade,and permit,had to go to Home Depot for round
pan and electric box for upgrades,,30 amp breaker 5500 w elements
Task# Description Quantity Your Price Your Total
T42610 STANDARD 50 GALLON ELECTRIC WATER HEATER-PLUS PERMIT AND UPGRADES 1.00 $895.00 $895.00
A61151 ELECTRICAL UPGRADE ON WATER HEATER-WIP ONLY- 1.00 $21 S.00 $215.00
NO SWITCH
A61152 WATER HEATER PAN 1.00 $115.00 $115.00
A99536 PERMIT-PLUMBING 1.00 $175.00 $175.00
D70652 COUPONS DISCOUNT FROM WEBSITE 1.00 $-25.00 $-25.00
A13200-1 1/2"BALL VALVE-CXC 1.00 $75.00 $75.00
Paid On Type Memo Amount
6/27/2018 Visa $1,450.00
6/28/2018 Visa $-1,450.00
6/28/2018 Visa $1,450.00
^� Sub-Total $1,450.00
Tax $0.00
Total Due $1,450.00
Payment $1,450.00
Balance Due $0.00
Terms:ALL ESTIMATES ARE GOOD FOR 30 DAYS.All material is guaranteed to be as specified.All work is to be completed in a professional manner
according to standard practices.Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders and
will become an extra charge over and above the estimate.All agreements contingent upon delays,beyond our control.All payments are due upon
completion of installation.All payments not received upon completion are subject to 1 1/2%service charge per month,or the maximum rate permitted by
law,whichever is less.In the event of non-payment,all costs incidental to collection,including without limitation reasonable attorney's fees shall be added
to the unpaid balance."CANCELLATION OF WORK AFTER DEPOSIT IS PAID:In the event a job is cancelled after the deposit is paid,a refund will be given
minus any permit(if applicable)and administrative fees that were paid by Admiral Plumbing.
PLEASE MAIL ALL PAYMENTS TO:
2895 JUPITER PARK DR#700
JUPITER,FL 33458
(561)746-1180
1 hereby agree to have Admiral Plumbing complete the work described for the proposed price regardless of the time it takes to complete
the work.
6/2 /2018
I hereby acknowledge the satisfactory completion of the above described work.
Residential Electric
Water Professional Classic Water Heaters
it
The new degree of comfort'
_—•--•�:.:s,__,waA�nx+:�:az�atarr„T.dl"� µr :`e4c>�xa, •c�-� ."� '+�-'s. _..._.._.
Professional Classic® electric water heaters are
engineered for longer life - resistored heating
elements and premium grade anode rod
Efficiency Plus...
•.90-.93 UEF •Rheemglae tank lining resists '
•Isolated tank design reduces corrosion and prolongs tank life
conductive heat toss •EverKleen'"self cleaning device fights
•Resistored copper upper element and harmful sediment build-up with a
resistored Lifeguard'"staintess steel high-velocity spiraling water stream—
lower element to prolong anode rod helps operating efficiency by saving
and tank life energy,money and improving tank life
Performance
•FHR:45-67 gallons,based on gallon •Enhanced-flow brass drain valve
capacity •Temperature and pressure relief valve
•Recovery:21 GPH at a 90"F rise included
System Sentinel •HUD certified for manufactured
(Available on selected models) housing and modular construction
•Exclusive diagnostic system with •Low lead compliant
glowing LEDs that verify heating Warranty
element operation.LEDs pin point the
exact location of functioning or non- •6-Year limited tank and parts
warr
functioning heating elements warranty'
e
Longer Life •with ProtectionPlus'"th 6-year limited
9 tank warranty becomes 10-year Professional Classic
•Premium grade anode rod provides 'See Residential Warranty certificate for complete
long-lasting tank protection information 19.9 to 55-Gallon Capacities
Features Units meet or exceed ANSI requirements and have 240 Volt AC/Single Phase
been tested according to the MAI operations Double and Single Element Models
•Electric junction box located above Manual and D.O.E.procedures.Units meet or
heating elements for easy installation exceed the energy efficiency requirements of Electric
NAECA.ASHW standard 90,(CC Code and all
•Over-temperature protector cuts state energy efficiency performance criteria.
off power in excess temperature UL
situations
•Automatic thermostat keeps water at
desired temperature
See specifications chart on back.
PRINTED IN V.SA 05110 MVP FORM NO.PROF RH N Rev.9
1
.%.%fto Water Residential Electric
I 1 Professional Classic Water Heaters
--- n•o ne«a3cr7ct^...T'iS�M'�ta�. �.-��r' �►t.r.�e-nL_,�a,�+.--«. •
Professional Classic®Specifications
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS(SHOWN IN INCHES) ENERGY INFO.
T t1EF WFORM
Y NOMINAL RATED FOW HOUR RECOVERY TANK HEWHT TO APPROX ENERGY
P GALLON GALLON MODEL RATOtG IN GAK REM? WATER CONK WMETER Set WT, mica
l: CAPA Y CAPACM NUMBER GPJL 9V F RISE A a C "34 NM
Too 30 27 PROE30 72 RH951 46 21 47-1/2 60.3/8 19.1/4 92 0.92
Tau 40 36 PROE40 T2 RH951 55 21 60-314 63.SM 19.1/4 109 0.93
Tau 50 45 PROE50 12 RH9Sr 63 21 58-6/8 61-5/8 20.1/4 121 0.93
Tau 55 55 PROE55 72 RH941 72 21 57 59-3/4 22.1/4 120 0.92
Mod. 30 27 PROE30 M2 RH95' 45 21 37-1/2 40-1/2 20.1/4 92 0.90
Mod. 40 36 PROE40 M2 RH95' 65 21 48-1/4 50-1/2 20-1/4 106 0.93
Med. 50 45 PROE50 M2 RH951 62 21 48 50-1/2 23 132 0.93
Short 19.9 - PROE20S2RH - 21 31-1/2 31-1/2 17 62 -
Shon 28 25 PROE28 S2 RH95 45 21 30 31-1/8 23 95 0.92
Short 30 27 PROE30 S2 RH95 8- 46 21 30-1/8 32 19-3/4 95 0.92
Shoe 36 33 PROE36S2RIM 46 21 31-1/2 33 24-1/4 118 0.92
Short 38 35 PROE36 S2 RH95 B** 51 21 31-1/2 1 32.5/8 23 108 0.92
Short 47 43 PROE47 S2 RH95 54 J 21 32 1 34 1 26-1/4 1 lag 0.93
tfil ofm Errs W Factor and fated gin xk capacity teased on Departnwt of Energy(DOE)(equxetttenis.
t System Sentinel optional.Add EC1 to the and of the model number.System Sentinel not available on single 8„
element models,available on dual element models only.System Sentinel not available In excess of 5 kW on
208 V models.
--Water heater amer"ns prxx to ststa9tx3 atst,W on Wardwt that t3 ndudea with water howdr.
•IieSterS twttiSited vritrt SsatWard?40 von AC.sa"ye pitaso rtott•srtttaaneous vwvwj,arts 4500 wan Uppta till wvrdr tleatxty
HOT
•If hosting elaments of different wattages than those shown are demanded by Sono regutroments,they mast be WATER
=��b requested. CONNECTION COLD
•Sutplo element erxx is avalabW on We;W ordar MOW max.).Substitute-1'for'2'0 modal number. WATER
•Special W4rIxj Optxltts-A lilted exanber of special wsatg optiaes are availabb.Cottsui factory for price a x1 avad0city. RELIEF VALVE CONNECTION
•Al models equtppea with treat traps. CONNECTION
ANODE
Recovery=wattagw2.42 x tomp.rut, F. ROD
Exa npfe: 450OW .21 GPH C
2.42 x 90, DIAMETER
ReCuvttry eulctdutKxts used aru tltraetl cxt 45110 watt eiBtrtatt5 tlsexl ar rwrr satruharxxxls nlwrutxxt
A
B
WATER CONNECTIONS ALL 314"N.P.T.
In keeping with its poky of continuous progress and prodluct improvernenr.Rheem reserves ire right to make charges without notice.
Rheom Water Heating • 1115 Northmeadow Parkway,Suite 100
Roswell,Georgia 30076 • www.rheem.com
PRKMD tN USA aVIa WP FOFW No.PROS RH N Rev.6