Loading...
HomeMy WebLinkAboutProduct Approval RECEIVED EXTERIOR RESEARCH&DESIGN,I.I.C. 1 J FI L ® 3 2018 Certificate of Authorization#9503 ` _ 353 CHRISTIAN STREET,UNIT#13 TRINITY ERD T. Luck COunty, Permitting OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-118 One Owens Corning Parkway FL10674-1113 Toledo,OH 43659ate of Issuance:02/06/2012 (740)404-7829 - �' Revision 8: 10/09/2017 rILE SCOPE: C0P., -m This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPEcriON:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: �p,g«lrrutr, *w 14 Robert J.M.Nieminen P.E. '•i"s� = ' N};k The facsimile seal appearing was authorized by Robert �:-, �+oNa� ,... Florida Registration No.59166,Florida DCA ANE1983 '- '�a++s+i�l� Nieminen,P.E.on 10/09/2017.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity)ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued., 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen,P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. '\\J TRINITY i ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential,Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Pro6erty Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Enti Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-132453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire""are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition Duration*, Duration' Premium Cool, Tru Definition' Duration Designer Color Collection,TruDefinition'Oakridge, Oakridge and weather Guard HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip&Ridge Shineles: 4.2.1 Berkshire" Hip& Ridge Shingles, High Ridge,WeatherGuard' HP Hip&Ridge Shingles, ProEdge Hip& Ridge Shingles and Dura Ridge'"4 Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This-is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire.Classification is not part of this Evaluation Report,refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 CertJicate of Authorization 49SM 6'H EDITION(2017)FBC NON-HVHZ EVALUATION I FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 PIC �PTRINUYJERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (Vint = 194 mph). Refer to Section.6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph(V,it=194 mph). Refer to Section 6.for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3,and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 611320-3. 6. INSTALLATION: 6_1 Underlavment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 611320-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6_2 Asphalt Shinfales: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire shingles.require minimum five(5)nails per shingle. ➢ WeatherGuard*HP shingles require minimum six(6)nails per shingle. ➢ Devonshirem shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt undedayment Deck ' Fehurtda&ymert Deck Seldedhered Weathedach8 Self-adhered undedaymunt WeatherLocko undedayment Drip dge edge_ Dripedge Drip Drip eedge ' Nails located Naos located 2=3"from eave 2'-3'hom cave Install first Self-searing adhesive D S S Sdkaaing adhe&e Starters positioned along eave with 6°removed p positioned along edYQ shingle= \ ••. `\ 6"removed Starter Strip shingle overhangs eaves and rakes'/?4V StarterSt ip Plus ovahangs eaves and rakes 114*-V4" Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-Rg Certificate of Authorizatron#9503 Gia EDITION(2017)FBG NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 qT'--RINITYIERD 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Area para Normal Mansard or Area para VVlnd Areas High Wind deavanes y Wind Areas High Wind desvenes y Area pare vientos normales Areas vientos/oertes Area,pars vier/toa normaies Areas vientos fuertes ''��, lAl z' IB z' '" iz (Ai tx � r1. x• (BF z' 1' . . . . 6"Exposure 6 618'(Exposure Exposleidn Exposieidn 6.2.7 Minimum Nailing—Berkshire®: &obnt sip sealant strip La tha de s0ador /La tlra de sellador 94 110 9 ve 9 Vi- 0 "8 W- 8 W 8 wl 8 W f / r r Standard Fastening Pattern 6-Nail Fastening Pattern Sealantstrip La*ado sdiador RaE—a'of--►• a�—►e�—s• a w 8Vf a VT 8lip t" / / r VTC 2" Asphalt rootieg.eement Cemento de Who de astafto Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8 Certificate ojAuthorizatlon#9503 6r"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-1113 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 l� TRINITY I ERD 6.2.8 Minimum Nailing—DevonshireTM': y 7" 8" 8" 8" 7e47 «1 Clams Nails 5.5/8n exposure sealant location " Exposicidn de 5.5/8 pull; Ubicacidn del sellador s�• �,. Ten 1"Spots of As haft Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDeffnitione Duration Designer Color Collection: 4-Nail Fastening Pattern 6-Nall Fastening Pattern SureN=fasw"area width SureNalMfasWdngamawfdh NAVICal Naumpicai f" 72" 12" 1" ,•pwsony,q ;.;,.r.=�: .otl-=_.�.v..:•n.vt!pwi" -s.Natl--A:-.n hP.en c.+aaww 'sat . a.w�am.o ..:.9.wtun?p .,-::£�:: 6•iro"6&9" �z- �j .' i. •'`�,y y� 5718 byu" ? �' Standard Fastening Pattem 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 SunNaliIDlashNig uea wICN Nau,rypl.1 1- +x" it r s.maa.csa..n._>v:s.•::: w.o..+o,:.s ...:.:o.aa - ®,rW.=;:._. C - afro^ssro^ u ff s Nat'u hp o: paurt"Spob oibplult RaoMg Gmml. Mansard or Steep Slope Fastening Pattern Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R8 Certificate o/Authorization#9503 6'N EDITION(2017)FBC NON-HVHZ EVALUATION FL30674-R33 Owens Coming Asphalt Roof shingles Revision 8:10/09/2017 Page 5 of 8 . . ` _ \ / ��K� �� 8 ��K �0 UU |��^u� 63.5 Minimum Nailing-Pm»Ed0aHip&KRidge Shingles: Prevailling Standard -11, Wind Direction S,,,,,tSWP Fastening Pattern T 6'Exposure Sealant Faden 7'b* 6'Exposure cover Exp sed Roof Cement 6.3'6 Minimum Nailing—DmxaRidgeTmHip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer toOwens Corning published installation instructions for their minimum requirements. TopMew Dinctiondomimntedivot 211s' CIM 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2J''1/0905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANupAcrumumG PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 OA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA8625;(631)S4G'2458;Kanuhi'A8rowm|o-Omkanio@u|.com - END OFEVALUATION REPORT' Exterior Research and Design,mc Evaluation Report oa79wn�2.12-om Certificate of Authorization#9503 o=EDITION iao17>pocmom'xvnoammmnom p1.10674-1113 Owens Corning Asphalt Roof Shingles ' Revision 8'10/og/2ozx Page mofm ' ` EXTERIOR RESEARCH&0ESIGN,LLC. iUL 032'018 Certificate ofAuthorization#95O3 3S3CHRISTIAN STREET,UNIT#13 QITRINITYIERD OXFORD,[TOG47Q PHONE:(203)262-9245 EVALUATION REPORT $Dy FAX:(203)262-9243 Interwrap,Inc. irvaluation Report 140510.02.12-113 --__-Mission Way L1 Mission,8[V2V'G64Canada Date mfIssuance:02'17/2012 (551)S74'2939 Revision 3:80/10/2017 Soops: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of constructio n materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edftiow (2017) Florida Building Code sections noted herein. � DcsomIPTu»N |U '- �� iAoeums: Labeling shall be in accordance miiththe requirements the Accredited Quality Assurance Agency noted herein. ComnmUsoKOMpu*mcE: ThisEva|uationReportisvaUdund|suchbmeasthmnamedprmduct(s)chan8es,thereferenced Quality Assurance documentation changes,orprovisions mf the Code that relate tothe product change. Acceptance of this Evaluation Report by the named client constitutes agreement to nn§h/ Robert Nieminan, P.E. if the product changes orthe referenced Quality Assurance documentation changes. Trinby}ERDrequires mcomplete review ofthis Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Evaluation Report number preceded bvthe words "Trinity}ER0Evaluated" may bedisplayed in advertising literature. if any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall beavailable for inspection atthe job site atthe request ofthe Building Official. This Ena|uadonReport consists ofpages 1through 3. Prepared by: Robert J.M.Nleminem, -E / - The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA A8E1f83 �—~ ' m��P.E.=10110/2017.This does not serve as an electronically signed document. CERTIFICATION o,INDEPENDENCE: z. Trinity\Enudoes not have, nor does itintend u, acquire orWiUitacquire, afinancial interest inany company manufacturing nr distributing products uevaluates. a. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. u. Robertm|eminen'P.E.does not have nor will acquire,a financial interest in any company manufacturing nrdistributing products for which the evaluation reports are being issued. u. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity Involved inthe approval process ofthe product. s. This isabuilding code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are,in any way,the Designer of Record for any project on wNdo this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. | TRINITY J ERD 6. INSTALLATION: 6.1 RhinoRoof Underlayments shall be installed in accordance with Interwrap, Inc. published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. - 6.2 Re-fasten any loose decking panels,and check for protruding'nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application.. Rh�noRoof U20 y r __ ._ ..... .. _ .. . .. _. w 6.3.1 Shall be installed in compliance with the requirements for ASTM D226,Type I or II underlayment in.FBC Table 1507.1.1 for the type of prepared roof covering to be installed, taking into account the wider sheet- width for double-layer applications. 6.3.1 Fasteners: For exposure<24 hours,corrosion resistant fasteners may be 1-inch roofing nails with a 3/8-inch diameter head,or those noted in 6.4.2. The use of staples is prohibited. For exposure > 24 hours up to maximum 30 days, corrosion resistant fasteners shall be minimum 1-inch diameter plastic or metal cap nails.or FBC HVHZ nails&1-5/8"diameter tin caps(with the rough edge facing up). The use of staples is prohibited. 6.3.2 Single Laver;Roof Slope>4:12: End(vertical)laps shall be minimum 6-inches and side(horizontal)laps shall be minimum 4-inches. Refer to Interwrap, Inc. recommendations for alternate lap configurations and/or the use of sealant under certain conditions. For exposure < 24 hours, use of every-other fastening location printed on the surface is acceptable. For exposure > 24 hours up to maximum 30-days, use of every fastening location printed on the surface is required. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens on the same day. Battens shall not be positioned over cap nails. If this occurs, remove the cap nail and patch the hole in accordance with Interwrap published instructions. 6.4.3 Double Layer;2:12<Roof Slope<4:12: End(vertical)laps shall be minimum 12-inches and side(horizontal)laps shall be minimum half-sheet-width plus 1-inch. Double layer application; begin by fastening a half-width plus 1-inch'starter strip along the eaves. Place a full-width sheet over the starter, completely overlapping the starter course. Continue as noted in 6.5, but maintaining minimum half-width plus 1-inch side(horizontal)laps,resulting in a double-layer application. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Qingdao,China 9. QUALITY ASSURANCE ENTITY: Intertek Testing Services NA Inc.—QUA1673;(608)836-4400 -END OF EVALUATION REPORT- Exterior Research and Design,U.C. Evaluation Report 140510.02.12-R3 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL15216-113 RhinoRoof Underlayments Revision 3:10/10/2017 Page 3 of 3