Loading...
HomeMy WebLinkAboutProduct Approval (2) 6/13/2018 Florida Building Code-Online s / / .ll e . 1 - -- - - - rA ' BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats&Facts I Publications I FBC Staff I BCIS Site Map I Links I Search Florida re Product Approval \ USER:Public User eP � Product ARproval Menu>Product or Ag2ilcation Search>&WLratlon List>Application Detail e s FL# FL13010-R6 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived O Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala,FL 34474 (352)368-6922 Ext 245 kpine@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Quality Assurance Representative ]ay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 (352)368-6922 Ext 291 jlathrop@cws.cc Category Windows Subcategory Fixed Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications,Inc. Validated By Steven M. Urich, PE O Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Ysd[ AAMA/WDMA/CSA 101/I.S.2/A440-05 2005 AAMA/WDMA/CSA 101/I.S.2/A440-08 2008 ASTM E1886-05 2005 ASTM E1996-05 2005 PA TAS 201/202/203 1994 Equivalence of Product Standards Certified By https:/Auww.floddabuilding.org/pr/pr app_Otl.aspx?param=wGEVXQwtDgvQEbBFEH6OVrs5wFsWUkbaazonS2SD!enp6keeguGfEA%3d%3d 1/3 6/13/2018 Florida Building Code Online Product Approval Method Method 1 Option A Date Submitted 05/30/2018 Date Validated 05/31/2018 Date Pending FBC Approval Date Approved 06/10/2018 Summary of Products FL# Model,Number or Name Description 13010.1 PW-8150 PVC Fixed Window PW-8150 PVC Fig/Fin Fixed Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL13010 R6 C CAC CAR 138-1357.pLf Approved for use outside HVHZ:Yes FL13010 R6 C CAC CAR 138-1362.pd Impact Resistant:Yes FL13010 R6 C CAC CAR 138-562.Of Design Pressure: N/A Quality Assurance Contract Expiration Date Other: PW-8150,36"x 72"and 72"x 76"see installation 09/14/2019 detail for DPs. Large Missile Impact. In HVHZ may only be used Installation Instructions up to 30ft above grade. Glass complies to ASTM E1300-04. FL13010 R6 II CWS-433D.pdf Verified By: Lucas A.Turner 58201 Created by Independent Third Party: No Evaluation Reports FL13010 R6 AE EvalRenort433D.odf Created by Independent Third Party: Yes 13010.2 PW-8150 PVC Fixed Window PW-8150 PVC Fig/Fin Fixed Window,Continuous Head&Sill. Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL13010 R6 C CAC CAR 138-261e2.pdf Approved for use outside HVHZ:Yes FL13010 R6 C CAC CAR 138-705e2.p-df Impact Resistant:Yes FL13010 R6 C CAC CAR 138-706e2.pdf Design Pressure:+67.5/-67.5 Quality Assurance Contract Expiration Date Other: Large Missile,Dp= +/-67.5 psf,Max.size 74 1/8"x 08/12/2019 72". Outer lite must be safety glass above 30 ft. in HVHZ. Installation Instructions Glass complies to ASTM E1300-04. FL13010 R6 II CWS-510C.Rdf Verified.By: Lucas A.Turner 58201 Created by Independent Third Party: No Evaluation Reports FL13010 R6 AE EvalReoort510C.pdf Created by Independent Third Party:Yes 13010.3 PW-8300 PVC Fixed Window PW-8300 PVC Flg/Fin Fixed Window, 120"x 48" Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL13010 R6 C CAC CAR 138-258e2.pdf Approved for use outside HVHZ:Yes FL13010 R6 C CAC CAR 138-483e2.pdf Impact Resistant:Yes FL13010 R6 C CAC CAR 138-482e2.W Design Pressure:+70/-70 Quality Assurance Contract Expiration Date Other: PW-8300, 120"x 48",DP= +/-70 psf. Large Missile 04/09/2019 Impact.Glass complies to ASTM E1300-04. Installation Instructions FL13010 R6 II CWS-373C.pdf Verified By: Lucas A.Turner,P.E.FL PE#58201 Created by Independent Third Party: No Evaluation Reports FL13010 R6 AE EvalReo2rt373C.Rdf Created by Independent Third Party:Yes 13010.4 PW-8300 PVC Fixed Window PW-8300 PVC Fig/Fin Fixed Window, 120"x 48" Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL13010 R6 C CAC CAR 138-1093.pdf Approved for use outside HVHZ:Yes FL13010 R6 C CAC CAR 138-1320 e2.12d Impact Resistant:Yes FL13010 R6 C CAC CAR 138-2504df Design Pressure: +70/-70 FL13010 R6 C CAC CAR 138-274e2.pdf Other: PW-8300, 120"x 48",DP= +/-70 psf. Large Missile FL13010 R6 C CAC CAR 138-457.pdf Impact. Glass complies to ASTM E1300-04.- FL13010 R6 C CAC CAR 138-465.pdf FL13010 R6 C CAC CAR 138-534.Rdf FL13010 R6 C CAC CAR 138-730e2.pdf FL13010 R6 C CAC CAR 138-739e2.r�df Quality Assurance Contract Expiration Date 03/16/2020 Installation Instructions FL13010 R6 II CWS-159E.pdf Verified By: Lucas A.Turner,P.E. FL PE#58201 Created by Independent Third Party: No Evaluation Reports FL13010 R6 AE EvalReo2rt159Lpdf Created by Independent Third Party:Yes hftps:/Avww.floddabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgvQEbBFEH60Vrs5wFsWUkbaazonS2SDienp6keeguGfEA%3d%3d 2/3 6/13/2018 Florida Building Code Online + Back b'leut Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.=yjght 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalLs provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: ® eChe'sk M ;Credit Card ;Safe-� i https://www.floddabuilding.org/pr/pr app_dti.aspx?param=WGEVXQwtDgvQEb8FEH60Vrs5wFsWUkbaazonS2SDienp6keeguGfEA%3d%3d 3/3 URNER 1239 Jabara Ave. North Port,FL 34288 ENGINEERING & Ph. 941-380-1574 CONSULTING, INC. FBPE C.O.A. #29779 Evaluation Report 159E September 7, 2017 Product Description: Series 8300 PVC Fixed Window,Large Missile Impact, 48"x 72"unit size DP55 or 72"x 76"unit size DP67.5 (DP65 outside HVHZ) Manufacturer: Custom Window Systems,Inc. 1900 SW 44th Ave, Ocala,FL 34474 Statement of Compliance: This report evaluates the above-listed product per the requirements of FAC Product Approval Rule Chapter 61G20-3.005 (4). This product complies with the requirements of the 6`h Edition(2017)Florida Building Code including the HVHZ. The product testing standards performed are outlined below. Technical Documentation: 1) This report,prepared by Lucas A.Turner,P.E.,at 1239 Jabara Ave.,North Port,FL 2) Approval drawing CWS-159E, signed and sealed by Lucas A.Turner, P.E. 3) Test Reports NCTL-210-3954-01 and 4A, and NCTL-210-3955-01 and 4A, from National Certified Testing Laboratories, Orlando,FL,with Testing Performed: AAMA/WDMA/CSA 101/I.S.2/A440-08,ASTM E1886-05,ASTM E1996-05/09 and TAS 201,202,203 1994(TAS reports 3954-1A and 3955-1A signed and sealed by Gerard J.Ferrara,P.E.) 4) Supplemental Calculations to support CWS-159E, signed and sealed by Lucas A. Turner,P.E. Installation: Units must be installed according to approval document CWS-159E. Limitations,of Use: This product: • May be used in O configuration in sizes up to 48"x 72"unit size at design pressures of+/-55 psf, or in sizes up to 72"x 76"unit size at design pressures of+/-67.5 psf in HVHZ or+/-65 psf outside the HVHZ,with max. glass daylight sizes as shown in CWS-159E • Is large missile impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires outer lite in I.G. to be safety glass when used in HVHZ above 30 ft of grade • Requires glazing as shown in CWS-159E,with Kuraray(Dupont) SentryGlas Interlayer per Miami-Dade NOA 14-0916.11 tin DP65 or 67.5 units or Kuraray(Dupont)PVB Interlayer per Miami-Dade NOA 16-1117.021 in DP55 units • Requires Quanex(Mikron)white rigid PVC framing per Miami-Dade NOA 17-0206.l Ot t I have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and find that they comply with the requirements of the 6`h Ed. (2017)Florida Building Code for use in this product. Certification of Independence: I do not have,nor do I intend to acquire,nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have,nor do I intend to acquire,nor will I acquire, a financial interest, in any other entity involved in the testing or approval process of this product. Lucas Turner :' No 58201 2017-09-16 �` 9/07/2017 Q Z Lucas A. Turner, P.E. 07:24+20:00 'o; STATE OF :,k/' FL PE #58201 ` #���or;'.ONAt-t��� PICTURE WINDOW - LARGE MISSILE IMPACT GENERAL NOTES: 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED WIFIDOW SYSTEMS TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT 1800 SW 44TH AVE. EDITION INCLUDING THE HIGH VELOCITY HURRINCANE ZONE(HVHZ) 1900 S FLORIDA E. AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS OCAWWW CFLORI 34474 DEFINED IN ASTM E 1996 PER THE FBC. 491/4" MAX.OVERALL 2.GLAZING OPTIONS:(SEE SHEET 3) MAX.OVERALL FLANGE WIDTH ALL FLANGE WIDTH 8300 PVC 48" 72• 3.CONFIGURATIONS:"0". ARCHITECTURAL SHAPES INCLUDE,BUT ARE PICTURE WINDOW MAX UNIT WIDTH MAX UNIT WIDTH NOT LIMITED TO,THOSE SHOWN ON SHEET 2. 451/8' 691/8' 4.DESIGN PRESSURE RATING: IMPACT GL GLASS DLOASS DLO -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND A ———————————————— GLASS TABLES ASTM E-1300-04e01/09. 4 Z ——————— —— I I -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER t= w O m w 0 p INFILTRATION TEST PRESSURE AND GLASS TABLES Z Z_j Z O 3 m I I I I ASTM E-1300-0401109. Q - –– I 771/4' I I 5.ANCHORAGE:THE 331/3°/STRESS INCREASE HAS NOT BEEN USED Z LL Z=� it W p p MAX. I I IN THE DESIGN OF THIS PRODUCT.SEE SHEET 8 FOR ANCHOR V 0 F-O0 U a H I-w IL 731/4" I I FLANGE I I ANCHOR CALCULATIONSRALL DETAILS. WINDLOAD RATION FACTOR Cd=1.6 WAS USED FOR WOOD Z ZO j Z Z j U rn VEO RALL B MAXI I I B HEIGHT I I } Q�O W-=0 HEIGHT I I I I I 6 REQUIRED.APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT Q m g }_�OZ I I 76" I I w DSD V)0wu)w O I MAX I O I 7.ALL FRAMES ARE FULLY WELDED. a Z=nw. w 0 2� 72' HEIGHT O w F-0 a S co MAXI I I I 8.SERIES/MODEL DESIGNATION PW-8300. a F a w 3 ww UNIT EL HEIGHT I I I 731/8" I I 9.THE DESIGNATION XAND 0 STAND FORTHE FOLLOWING: 691/8• I I I DLO t4 I O=FIXED SASH. ,` r10RE4yeTG!0�� GLASS DLO R P 10.SECTION CALLOUTS APPLY TO ALL ELEVATIONS INA SIMILAR `.`VP;•�LGENgF.•Qy��� I 8 O I I LOCATION. Z­J: No 58201 '.P I g I IWit•• TATE OF �kr� ---- —=4-- ---------------- A �i F'.,COR10P��t;�� ....E���`� 9/22/2017 LucasTurner LUCAS A.TURNER,P.E. FL PE#58201 2017-09-22 1239 JABARA AVE. NORTH PORT,FL 34288 11:45-04:00 PH.941-380-1574 SHEET DESCRIPTION: GENERAL NOTES AND TABLE OF CONTENTS ELEVATIONS GENERAL NOTES&ELEVATIONS.......1 LOCATION MAX. UNIT SIZE DESIGN PRESSURE RATING IMPACT RATING DRAWN BY: DATE: ARCHITECTURAL SHAPES...................2ANY 4 S" 72" +/-55 PSF ADE 05/05/07 GLAZING DETAILS.................................3 DWG A: REV.: SECTION VIEWS....................................4 NON- VHZ +-65 PSF LARGE MISSILE IMPACT EXTRUSIONS&B.O.M...........................5 72"X 76" CWS-159 E ANCHOR SCHEDULE&NOTES.........6-7 HVHZ +/-675 PSF SCALE: . INSTALLATION DETAILS.......................8 SHEET 1:20 1 OF 8 WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CWS.CC 8300 PVC PICTURE WINDOW IMPACT FULL ELLIPSE("OVAL'S a z �: ¢z3 FULL CIRCLE z w J❑ a k Z w w z0z D:-- - TOMBSTONE ❑ —m— O X�m LLrw �1-�2x z zx� awoo U Ut~i)OVdIx-t~nd yz Q OzUUZ❑UU I-—LLM O O LLz w 0❑�v}ioIII(aw LL' LL a. -wip 0J(AF O w�0 wxwy n I- n. a�'a NOREW 1!*, i 1/2 CIRCLE �.�Gp`;.�G......Ng0 No 58201 %•.,�?S OCTAGON TRAPEZOID �Ot,. STATE OF .41.1 OR 10 SSItoff ONA t E����� NOTES: y 1.SEE SHEETS 6&7 FOR DETAILED ANCHOR INSTALLATION REQUIREMENTS. 2.THRU FRAME-MASONRY,WOOD OR METAL OPENING. 9/22/2017 THRU FIN-WOOD OPENING. LUCAS A.TURNER,P.E. 3.OVERALL SIZE MUST NOT EXCEED THE MAX.WIDTH AND HEIGHT OF FL PE#58201 JABARRECTANGULAR WINDOWS ON SHEET 1. NORTH PORT,1239 PORT, AVE. FL 34288 4.ANCHOR SPACING FOR ARCHITECTUAL FLANGE AND FIN WINDOWS IPH.941-380-1574 MUST FOLLOW THE LAYOUTS SHOWN ON SHEETS 6&7,WITH ANCHOR SHEET DESCRIPTION: SPACING MEASURED ALONG THE LENGTH OF THE PRODUCT. 1/4 CIRCLE TRIANGLE ARCHITECTURAL SHAPES DRAWN SY: DATE: ADE 05/05/07 DWG#: REV.: CWS-159 E SCALE: SHEET 1:1 2 OF 8 WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CWS.CC 8300 PVC PICTURE WINDOW IMPACT z 3 azo owowwod Ill zoz OW U. �x Z zxm WWOO O OI-OLj<=I-w 1.OVERALL 1'OVERALL U U rn I-z Il F rn a 3/16'ANNEALED or TEMPERED 3/16"HEAT STRENGTH or TEMPERED z O O U uj Z j U N 1/2"AIRSPACE 3/8'AIRSPACE > 'a LLOy W-2 O Z 5/16"LAMINATED 7/16"LAMI GLASS H Z W O(n W cl)O J ICn n Lu 1/8'ANNEALED 3/16"HEAT STRENGTH d ?=D. Ir O rn O wF � wx�cn .090 DUPONT PVB INTERLAYER .090 SENTRY GLASS IONOPLAST INTERLAYER a H 0_ 0=�:d 1/8"ANNEALED 3/16'HEAT STRENGTH OREW 44 OUANEXDURASEAL 6 PURFECTGLAZE"H' QUANEXDURASEAL g PURFECTGLAZE"H" �� pSP�NGENg�rGQ�iy IG SPACAR SIKAFLEX 552 IG SPACER SIKAFLEX 552 :JG•\ 'p 'yy� No 58201 S 1/2"GLASS BRE 10 1/2"GLASS BRE 7 0: STATE OF •:�lll� 1 cm z�- GLASS TYPE A :GLASS TYPE B 9/22/2017 -- LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: GLAZING DETAILS GLASS MAXS12 DRAWNBY: DATE: SETTING BLOCKS PER FBC 2411.3.3.1 TYPE W X H ADE 05/05/07 DP+/-55 A 48 X72 DWG 11: REV.: CWS-159 E < P+/-67.5 B 72X7 onLE: SHEET 101:1 3 OF 8 34 ��• WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA,FLORIDA 34474 W W W.CW S.CC INTERIOR 7 6 8300 PVC 6 9 9 6 PICTURE'WINDOW 0 7 6 6 7 IMPACT 1 Q Z ¢z3 10ri Z W_jO tnWOp o -COZ 0w3m_ z 0`06Q2WQp U U~OQa2Fo a. a z�jZZ I. SECTION VIEW B-B O Z 0 z U 10 11 11 10 �- a3pw0=oz w ow0ui(nw fnLu J(AH zQ - awo w~� Lu Q. o a D_ a INTERIOR to��.t oREW N, •ys No 58201 •t�?1 =roe a 0:• STATE OF :��I` 11 6 9 10 ❑ � z 6 A.212017 TU LUCAS A.TURNER,P.E. Q QFL PE#58201 -- 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 7 6 SHEET DESCRIPTION: SECTION VIEWS SECTION VIEW A-A DRAWN BY: DATE: ALTERNATE FIN FRAME ADE 05/05/07 DWG#: REV.: CWS-159 E SCALE: SHEET 1:1.33 4 OF 8 PARTS LIST FRAME CORNER CONSTRUCTIONMgM �( ITEM PART# DESCRIPTION VENDOR MATERIAL ` WINDOW SYMMS 1 H-60068 FRAME, PW, MAIN, HEAD MIKRON 1900 SW 44TH AVE.OCALA,FLORIDA34474 2 H-6006B FRAME, PW, MAIN, SILL MIKRON PVC WWW.CwS.Cc 3 H-6006B FRAME, PW, MAIN, L. JAMB MIKRON PVC ` 4 H-6006B FRAME, PW, MAIN, R. JAMB MIKRON PVC zCORNER WELD(ALL SIDES) 8300 PVC 5 H-6006A FRAME, PW, MAIN, FIN MIKRON PVC SCALE I:8 PICTURE WINDOW 6 P-3113 SCREW SUPPORT FOR PVC TEAM PLASTIC RUBBER IMPACT 7 P-3352 SET. BLK., 85 DUR., 1/8"x 5/8"x 2" LG. FRANK LOWE RUBBER 8 PURFECT GLAZE"H", SIKAFLEX552 HENKEL/SIKA SILICONE gN w a o 9 P-3752 CAP PLUG, 1/2" HOLE M&M SILICONE z w-1°o a k Z w w zoz 10 S-6064 GLZ BE., F)l. (1" O.A. I.G.) MIKRON PVC F w 3�°:m 11 GLASS SEE SHEET 3 0 0�00a=pW 0 umizaf-ma O zO—�—Z1-VU) 3118" 31/8' H Z LL M 0 0 IL ~ mjOF CO lil 00w co OwtnW ❑ ❑ a 0�tnl- 1 2 3 4 5 Jx _~, w� N a F a o' a LU 21/16•ZnM fns° �� 1ns• ��L%%OI"`OREWr G' �•°yam+ 2 718" No 59201 '�1S• #� ,k *' Wit• STATE OF ;mak/` 11/2' PVC FRAME FLANGE-H-60066 r4nunpd PVC FRAME FIN-H-6006A X� 1/4• 9/22/2017 LUCAS A.TURNER,P.E. 3" FL PE#58201 7/8• 10 1239 JABARA AVE. J� 3/16• 8 NORTH PORT, 34288 PH.941-380-1-1 574 SHEET DESCRIPTION: PVC GLAZEBEAD-S-6064 SCREW SUPPORT-P-3113 EXTRUSIONS&B.O.M. DRAWN BY: DATE: ADE 05/05/07 DWG#: REV.: CWS-159 E SCALE: SHEET 1:1 5 OF 8 14'MAX.O.C.(TYP.) VVI��lURhNJ(YIIUUU(I�• 6"MAX.(TYP.) SEE NOTE 2 4"MARX.(TYP.) 8"MAX.O.C.(TYP.) SEE NOTE 2 m.P) 1900 SW 44TH AVE. 6'MAX ) ---------- ---------- WWW.CWS.CCA34474 I I I I I I I I 8300 PVC I I 8' I I PICTURE WINDOW MAX O.C. I I gyp.) I I INSTALLATION IMPACT INSTALLATION I I ANCHOR(TYP.) II _ i ANCHOR(TYP.) MAX O.C. I I Q Z 3: aZ� I I I I au10 awop I I I I W zOz D'k?� LL o Hwy 0�3= I I I I Z Z LLI O O I I I I 0 Ol�-O�j<=I...w I I I I 0 Z"-'mZZ_ _ I I I I a PZ MZOU o I I I I �30F�tOZ I I I I a:w'S o� w arn0uicoui I I I I Zmw O-1m� I I I I 0 UJ I- a.x ---------- —————————— a D D' D. Lu ANCHOR LP.AYO 5 -(FLANGE) ANCHORDP LAYOUT-(FIN) �,,S,PNV REW I Tfoo .�GP•55 PSF X SF•";pL�• r t No 58201 =roe a_ :y9Q� STATE OF 00.- NOTES: PNOTES: 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.ANCHOR SPACINGAPPLIES TO ALL SHAPES(SEE SHEET 2)ALONG ALL FRAME EDGES. SILL ANCHOR SPACING SAME AS HEAD. 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE �Z CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 8. 9/22/2017 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E. FL PE#58201 BE PROTECTED TO PREVENT REACTION. 1239 JABARA AVE. 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 PH.941-380-1574 SPECIFIED IN TABLE 1,SHEET 8. SHEET DESCRIPTION: 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. ANCHOR SCHEDULE& INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQURE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. DRAWN BY: DATE: 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. ADE 05/05/07 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG#: REV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 8. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-159 E 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMA/AAMA 100(FIN WINDOWS),FMAIAAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS),FMA/AAMAANDMA 300(E)CTERIOR DOORS) 1:20 6 OF 8 WINDOW SYSTEMS 4-MAX.(TYP.) 8"MAX.O.C.(TYP.) 1900 SW 44TH AVE. 6-MAX.(TYP.) 7 5/8"MAX.O.C.(TYP.) SEE NOTE 2 4'MAX.(TYP.)7 SEE NOTE 2 W W OCALA, FLORIDA 34474 6-MAX.(TYP.) I I I I 8300 PVC I I I I PICTURE WINDOW 7 5/8" I j MAX O.C. j j IMPACT (MAAX;.C. I I 0YP.) I I ¢z� I I I I z w-10 <rgw w zOz}}wkzt I _ (NSTALLATIONANCHOR(TYP.) I I (ANCHOR(TYP.)NSTALLATION OLL F-w z O� 2 I O I I O I O OF=-OcjQ=pw I I I I o Z-w-ZF?�a I I I I a oZ�U)ZOo- I I I I > ¢how—xO— I I I I 00�cn v}iowuO—iw a wO rn z_ O I I I I (L F�Q. rK CL to I I I I ----------------- ---------------- ,, ,, `1Gp�; NC E N FTG�2'� ANCHOR LAYOUT-(FLANGE) ANCHOR LAYOUT-(FIN) No 58201 t��3 OP+/-65 PSF DP+/-65 PSF 9 t STATE OF "'/U: ..OR10PG�?� ONAJAlp 11 NOTES: 10 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.ANCHOR SPACING APPLIES TO ALL SHAPES(SEE SHEET 2)ALONG ALL FRAME'EDGES. SILL ANCHOR SPACING SAME AS HEAD. 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4'. USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE y o� CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 8. 9/22/2017 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST LUCAS A.TURNER,P.E. BE PROTECTED TO PREVENT REACTION. FL # A 1239 JABARA AVE.A 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET 8. PH.941-380-1574 SHEET DESCRIPTION: 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE. ANCHOR SCHEDULE& INSTALLATIONS TO SOLID CONCRETE OR GROUT-FILLED CMU MAY INCLUDE BUT DO NOT REQURE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. NOTES DRAWN BY: DATE: 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3"FOR MASONRY,1"FOR WOOD AND METAL. ADE 05/05/07 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG s: REV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 8. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-159 E 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMA/AAMA 100(FIN WINDOWS),FMA/AAMA 200(FLANGE WINDOWS), FMANVDMA 250(BOX WINDOWS),FMA/AAMAANDMA 300(EXTERIOR DOORS) 1:20 7 OF 8 MIN.EMBEDMENT SEE TABLE 1 SUBSTRATE V(Yl9N1lUUl���WWW///uucr I(�f(Y�'/�I TYPICAL HEAD ANCHORAGE BY OTHERS WINDOW SYSTEMS 114"MAX.SHIM SEE TABLE 1 MIN.EDGE DIST. SUBSTRATE 1900 SW 44TH AVE. MIN.EDGE DIST. SEE TABLE 1 BY OTHERS OCALA,FLORIDA 34474 SEE TABLE 1 1/4'MAX.SHIM SEE TABLE I WWW.CWS.CC MIN.EDGE DIST. SUBSTRATE BY OTHERS SEE TABLE 1 SEE TABLE 1 MIN.EMBEDMENT 8300 PVC PERIMETER SEALANT SEE TABLE 1 SEE INSTALLATION ANCHOR BYINSTALLER ❑� MIN.EMBEDMENT BLE I PICTURE WINDOW INSIDE AND OUT SEE TABLE 1 IMPACT SEALANT BEHIND GOD] f-1 ❑ FLANGE BY INSTALLER GOp� Z Q 1/4'MAX.SHIM Q Z O ❑ PERIMETER SEALANT Z w-i 0 ¢ Z w PERIMETER SEALANT BYINSTALLER w Z O Z O_--F INSIDE AND OUT o 0)—7 O w m INSIDE ANDER Q }�- INSIDE AND OUT INSTALLATION ANCHOR Z Z 2 2 4 Z W O p SEALANT BEHIND SEE TABLE 1 00�O Lj a FZ-�w Y INrL STALLER SEALANT BEHIND 0Z Z—m z Z��y \ FIN BY INSTALLER Q 60:1 ui Z Q LL O INSTALLATION ANCHOR �� HORIZONTAL SECTION (C \ HORIZONTAL SECTION >- 4 LL W 0=O Z SEE TABLE 1 8 TYPICAL JAMB ANCHORAGE S TYPICHEAD ANDISILL SIMILAR FOR FIN INSTALLATION ¢ �CHORAGE ~/7 3 p w Olnw�OJfAF- a p Lu a=�a}i as � R. W(L 1/4'MAX.SHIM ,��� PtVOREIv T i� S ALLAN BEHIND) ER O � s �OENgFG�Qti��� r �r No 58201 ":�9 PERIMETER SEALANT BYINSTALLER MIN.EMBEDMENT INSIDE AND OUT SEE TABLE 1 O.. SUBSTRATE BY OTHERS SEE TABLE 1 MIN.EDGE DIST. SEE TABLE 1 SEALANT UNDER SCREW A VERTICAL SECTION HEAD BY INSTALLER 8 TYPICAL SILL ANCHORAGE ❑� � 9z/2017� TABLE I:APPROVED INSTALLATION FASTENERS O FRAANCHOR TYPE FL PE#58 01 LUCASP.E. LANGE CONCRETE(2.0 KSI MIN.) 3116"ITWTAPCON 1-1l2" 1-118" PERIMETER SEALANT 1239 JABARA AVE. FLANGEBYINSTALLER NORTH PORT,FL 34288 FLANGE CONCRETE(2.85 KSI MIN.) 3/16'ELCO ULTRACON 1" 1" INSIDE AND OUT D HORIZONTAL SECTION PH.941-380-1574 SHEET DESCRIPTION: FLANGE GROUT-FILLED CMU(ASTM C-90) 3/16"ELCO ULTRACON 1-1/4" 2-1/2" 8 BOX FRAME INSTALLATION FLANGE 2XMIN.SOUTHERN PINE(G=0.55) 3/16"ITW TAPCON 1-3/8" 7/8" HEAD AND SILL SIMILAR FOR BOX INSTALLATION INSTALLATION DETAILS OR ELCO ULTRACON FLANGE 2XMIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 718" FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, DRAWN BY: DATE: FLANGE 16 GAUGE(0.060")MIN.STEEL STUD 910-16 HILTI KWIK-FLEXOR ITW FULL THREAD 7/16" UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: ADE 05/05/07 (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" -MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED DWG#: REV.: 1/8'ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. CWS-159 E FLANGE 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" 7/16" -PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SCALE: FIN 2XMIN.SOUTHERN PINE(G=0.55) #8 WOOD SCREW 1-1/2" 7/16" SHOWN FOR FLANGE WINDOWS. 1.2 SHEET 80F8