Loading...
HomeMy WebLinkAboutProduct Approval (2) ' �y '.i BCL Homc Log In Uscr Registrticn ; Hot Topic Submit S-u-charge Stats&Fat Publications FBC'Staff f,BCIS Sitc'Map ; Links- Scarch bo U1,11 Product Approval USER:Public User da � Product Approval Menu>Product or Application Search>Application List>Application Detail [-REC�EIVED „ zn FL# FL17184-R4 01 Application Type Revision J U L 0 5 L $ Code Version 2017 Application Status Approved ST. Lucie County, Permitting Comments Archived (� Product Manufacturer Plastpro Inc./Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES,CA 90045 (440)969-9773 Ext 16 rickw@rwbidgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles,CA 90045 (440)969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. o the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J.King, P.E. 0 Validation Checklist-Hardcopy Received LU Certificate of Independence FL17184 R4 COI (p)Certificate of Independence.pdf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA101/I.S.2/A440 2005 ASTM E1886 2005 ASTM E1886 2002 ASTM E1996 2002 ASTM E1996 2006 ASTM E1996 2005 ASTM E330 2002 TAS 201,202,203 1994 .Y Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL17184 R4 Equiv (a)Equivalency of Standards.pdf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/10/2017 Date Validated 10/13/2017 Date Pending FBC Approval 10/19/2017 Date Approved 12/12/2017 Date Revised 03/07/2018 Summary of Products Go to Page I Page 1/2 1 FL# Model,Number or Name Description 17184.1 a.Fiberglass Door "Impact"Fiberglass Glazed Single Door with or without Sidelite(s)(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 II (a)Inst 17184.1.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.1 for any additional use limitations, FL17184 R4 AE (a)Eva] 17184.1.pdf installation instructions and product particulars. Created by Independent Third Party:Yes 17184.2 b.Fiberglass Door "Impact"Fiberglass Glazed Double Door with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 II (a)Inst 17184.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.2 for any additional use limitations, FLI '84 R4 AE (a)Evil 17184.2.pdf installation instructions and product particulars. Created by Independent Third Party:Yes 17184.3 c.Fiberglass Door "Non-Impact"Fiberglass Glazed Single Door with or without Sidel]te(s)(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 II (b)Inst 17184.3.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.3 for any additional use limitations, FL17184 R4 AE (a)Eva] 17184.3.pdf installation instructions and product particulars. Created by Independent Third Party:Yes 17184.4 d.Fiberglass Door "Non-Impact"Fiberglass Glazed Double Door with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FI-17184 R4 II (a)Inst 17184.4.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.4 for any additional use limitations, FL17184 R4 AE (a)Eva[17184.4.1)df installation instructions and product particulars. Created by Independent Third Party:Yes 17184.5 e. Fiberglass Door "Impact"Fiberglass Opaque Single Door with or without Sidelite(s)(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17134 R4 II (a)Inst 17184.5.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.5 for any additional use limitations, FL17184 R4 AE (aa)Eval 17184.5.2df Installation instructions and product particulars. Created by Independent Third Party:Yes 17184.6 f. Fiberglass Door "Impact"Fiberglass Glazed Double Door with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 6'8 In Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17134 R4 1I (a)Inst 17184.6.odf Approved for use outside HVHZ:Yes Verffied By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.6 for any additional use limitations, FL17184 R4 AE (a)Eval 17184.6.odf installation instructions and product particulars. Created by Independent Third Party:Yes 17184.7 g.Fiberglass Door "Impact"Fiberglass Opaque Single Door with or without Sidelite(s)(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 II (a)Inst 17184.7.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.7 for any additional use limitations, FL17184 R4 AE (a)Eval 17184.7.1)df installation instructions and product particulars. Created by Independent Third Party:Yes 17184.8 h.Fiberglass Door "Impact"Fiberglass Opaque Double Door with or without Sidelftes(XX or OXXO)Outswing/Inswing Conffguratlons up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 II (a)Inst 17184.8.p_df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.8 for any additional use limitations, FL17184 R4 AE (a)Eval 17184.8.pdf installation instructions and product particulars. Created by Independent Third Party:Yes 17184.9 1. Fiberglass Door "Impact"Fiberglass Glazed Single Door with or without Sidelite(s)(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 6'8 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R.4 II (a)Inst 17184.9.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.9 for any additional use limitations, FL17184 R4 AE (a) Eval 17184.9.pdf installation instructions and product particulars. Created by Independent Third Party:Yes 17184.10 j.Fiberglass Door "Impact"Fiberglass Glazed Double Door with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 68 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 1I (a)Inst 17184.10.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.10 for any additional use FL17184 R4 AE (a)Eval 17184.10.odf limitations, installation instructions and product particulars. Created by Independent Third Party:Yes 17184.11 k.Fiberglass Door "Non-Impact"Fiberglass Glazed Single Door with or without Sidelite(s)(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 7'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 II (a)Inst 17184.11.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.11 for any additional use FL17184 R4 AE (a)Eval 17184.11.odf limitations, installation instructions and product particulars. Created by Independent Third Party:Yes 17184.12 I.Fiberglass Door "Non-Impact"Fiberglass Glazed Double Door with or without Sidelites()X or OXXO)Outswing/Inswing Configurations up to Nominal 7'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 II (aa)Inst 17184.12.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports ,� ., .t, 1- .. ys. �� _ .� �, . ., _ Fa. - .. '' �a y .:�. ,� �. Other:See INST 17184.12 for any additional use FL17184 R4 AE (a)Fval 17184.12.pdf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17184.13 m.Fiberglass Door "Non-Impact"Fiberglass Opaque Single Door with or without Sidelite(s)(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 7'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 II (a)Inst 17184.13.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.13 for any additional use FL17184 R4 AE (a)Eval 17184.13.pdf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17184.14 n.Fiberglass Door "Non-Impact"Fiberglass Opaque Double Doer with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 7'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 II (a)Inst 17184.14.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.14 for any additional use FL17184 R4 AE (a)Eval 17184.14.pdf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17184.15 o.Fiberglass Door "Impact"Fiberglass Glazed Single Door with or without Sidelite(s)(X,OX or XO,OXO)Outswing/Inswing Configurations up to Nominal 7'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 II (a)Inst 17184.15.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.15 for any additional use EL17184 R4 AE (a)Eva[17184.15.pdf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17184.16 p. Fiberglass Door "Impact"Fiberglass Glazed Double Door with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 7'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R.4 II (a)Inst 17184.16.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.16 for any additional use FL17184 R4 AE (a)Eval 17184.16.1)df limitations,installation instructions and product particulars. Created by Independent Third Party:Yes 17184.17 q. Fiberglass Door "Impact"Fiberglass Opaque Single Door with or without Sidelite(s)(X,OX or X0,OXO)Outswing/Inswing Configurations up to Nominal 7'O in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 II (a)Inst 17184.17.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.17 for any additional use FL17184 R4 AE (a)Eval 17184.17.pdf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes .17184.18 r.Fiberglass Door '•'Impact'Fiberglass Opaque Double Door with or without Sidelites(XX or OXXO)Outswing/Inswing Configurations up to Nominal 7'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 II (a)Inst 17184.18.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.18 for any additional use FL17184 R4 AE (a)Eva] 17184.18.pdf limitations, installation instructions and product particulars. Created by Independent Third Party:Yes- 17184.19 s.Fiberglass Door "Non-Impact"Fiberglass Glazed Single(Steel Reinforced Stiles)Door with or without Sidelite(s)(X,OX or XO,OXO) Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 II (a)Inst 17184.19.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.19 for any additional use FL17184 R4 AE (a)Eval 17184.19.odf limitations, installation instructions and product particulars. Created by Independent Third Party:Yes 17184.20 t. Fiberglass Door "Non-Impact"Fiberglass Glazed Double(Steel Reinforced Stiles)Door with or without Sidelites(XX or OXXO) Outswing/Inswing Configurations up to Nominal 8'0 in Height Limits of Use Installation Instructions Approved for use in HVHZ:No FL17184 R4 II (a)Inst 17184.20.pdf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 17184.20 for any additional use FL17184 R4 AE (aa)Eval 17184.20.Ddf limitations,installation instructions and product particulars. Created by Independent Third Party:Yes Go to Page j L s Page 1/2 ilk Back FN-1 Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an WEED employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: W 99 RE M Cfedit Card Safe. a s t, r ��� •. p o N. �: ... f" :�.,� * 5200 W. CENTURY BLVD. Z LOS ANGELES CA 90045= `'� j111*1sss. 0 U N•: GLAZED FIBERGLASS SINGLE DOORe 9 �-115PMAX.OVEPALLFRAMEWIDTI-1— x 3°on w/or w/out S1DElITES 3.1 i , m a�R RAMEMAN. , >,4Z OVERALL FRAME WIDTH u INSWING/OUTSWING 1� FRAME WIDTN $Z o �1a "IMPACT' x uo o GENERAL NOTES = zg oz 1. This product has been evaluated and Is In compliance with the 6th Edition 0 X 0 0 x R: )2017)Florida Bufiding Code)FBC)structural requirements excluding the 'High Velocity Hurricane Zone"(HVHZ). '" > O O • o ° 2. Product anchors shall be as fisted and spaced as shown on detrnls.Anchor 41 OX &I a embedment to base material sholl be beyond wait dressing or stucco. 3. When used in areas requMng urinal borne debris protection this prod!pct a I, I Ll compiles vnlh FBC Sections 1609.1.2 8,P,301.2.1.2 and does not require an 1�I impact resistant covering.This product meets missile level'D"and Includes - — Vend Zone 4 as defined n ASTM E1996 and FBC Sections 1609.1.2 2& OXO x ° + 83012.11.1. - OS N 4. For 2x stud framing conshuction,anchoring of these units shag be the some w g Z as that shown for 2x buck masonry construction, 5. Site conditions that deviate from the details of this Thawing require further XO 22 rc ersgineedng analysts by licensed engineer or registered architect. a TABLE OFcONTENIS MAX. MAX.SIDELHE DESIGN PP.ESSUP.E(PSF) - SHEE]A pFSCR(MON CONFIGURATION FRAME D.LO. OUTSWING 42--�I Typ cO slava ons, es essures8 ener0 notes DIMENSION DIMENSION POSITIVE NEGATIVE2 pane etWs glozing 001003 erstepanelderatisandg etc0 X 37.5"X 98.0" 20.5"X 78.25' +50.0 -50.0 4 Elevation, -W--02 21112 S Horkontal..'ons OX/XO 76.25"X 98.0" 20.5"X 78.25' +500 -500 N. 6 Verllcdcrosssection, . . 9 7 Verflcdvoss sections oxc ft JK o' 0 Burka OXO 115.0"X 98.0" 20.5"X 78.25' +50.0 -50.0 C-W< LFs ; Frame anchoring ma.. e 10 H ardwae FL-17184.1 11 Bis°m0,� and carnponenls Z d 12T `_0.01" Gl O.Bt" �`'� -12T �00�. /�'� m EXTERIOR _-.'_I �" �� ••, �z r� SALE INTERIORSTILE TOP RAIL q (COMP.) COMP. LOCK BLOCK ( ) (COMP'1 SIILEREMFOR(WO�) (2D'LONGWOOD) __wl�D REINFORCEMENT HAWwo9cm li HORRONTAL CROSS SECTION FOAM CORE (POLY9 N PCFMAN.) FJa � MANBlACNSEII _. NOUH. ,, � r - •• -.:..:: IGCK.. S:TSWNAN➢ESFNC STRUMRALSIUGNE(DOW995)XwNSEr [---J--5jjrGLASSBffE e LOCK: YN CouECBON 24.2T MAX _ NON STRUCTURAL SEALANT EXT. uJa YALE _mosom YROOI¢ertGN(�_semes) FRNIE WIDTH V OVERALL GLASS)HK. c' —' KNOB: 'F'SEEIFSTFIE) 88 pU SCBLAGE UERoat)@.%-swm(ESo1&l 201'MAX. I/8•ANNEALED GLASS orn Fr D.L.O.TwLmi� o INTERLAYER L®PVB 8 _ INTERLAYER _ OOOR 1/B'ANNEALED GLASS INTERIOR EXTERIOR a� Z oz is 15 PANEL WIDTH i \ AIR SPACE \\\ �••VWTEMPERED GLASS 2 h a7-19X1-31r PPH \_ ALUMINUMSPACER Y SHFDRILLING SMS 3A MT,NON STRUCTURAL SEALANT--J UU � = 6T IALNG DEFAIL �� I d o FIBERGLASS SKIN R w. zo s O E,o 10.07S'THICK) �'F S i _SEE HARDWARE I a O N _ CHART tj f d Ij' N n O.OGT f hn o BOROM RAIL �Z (COMP.) •. x+02 21 12 N.1:5. - - - 3A ODl LNE FRAME orm.eh JK 4.25 �� 1/�md 2 VERTICAL CROSS SECTION aM.er. LFS a �D DOOR PAH n . ODL WE FRAME FL-17184.1 n sxm.2 or If d I I ' GI 0161" Iflf 0.81" 1.22 -� 1.19, EXTERIOR 1.75 �all" L z 's; STILE INTERIOR STILETOP RAIL -� * a'm z (COMP.( (COMP.( (COMP.( .. G z R z u Y STILERENFORCEMENT (WOODEPORCEMENT (wooD) HORIZONTAL CROSS SECAON FOAM CORE v° s'` 3 (POLYURERiANE• vz 1.9 PCP MN.) a STRUCTURALSILICKE(DOW 9951 5/B'GLASS BITE FRAME WR)1HNON STRUCTURAL SEALANT I EXL a a3 20.S MAX. it ---1"OVERALL GLASS INK. '$ o 35.75 MAX. D.L.O.VADTH I ^�I/8"ANNEALED GLASS DOOR0090'SAMOPYB a g �PANELWIDTH INTERLAYER O h.; 1/9"ANNEALEDGLASS INTERIOR EXTERIOR 11j AIRSPACE 1 k I/8"TEMPERED GLASS 3 i 97-19 X 13/4'PPH `ALUMINUM SPACER T— * SEIFDRILLING SMS 3A rT. - r, NONSTRUCTURALSFALANf � � I G1 GIADNG OETAR nv x O O I' L'1 t3 O O RBERGLASSSYJN B a p 77 --Tec (amsTHcq 1219 C I n o _ L „ O am 02 21 12 9 4.2S I 3A ODI LREIPAME (COMP.1 N•1JK a 60 SIDEUTE PANEL PP.) F� '1 c�a 1; LFS n ODL LRE FRAME0 VER71CAL CROSS SECTION m.m-, `3J FL-17184.1 ^ d R:Ia�axltRasePe,ue PPANANBRN•Ram naauxaa.wanv4-vlee Fac+glms Dar•nawla�rstu te+�plc•omw�mlltt•vsw bTx m Oos>)yt 17lea.sa.am.1� - m z may` L �w N 41 0.0.' N d V� ..a V W 3 �•\ O V fVA N xO v N fl„6Y P N N �N A V� V W •� 1` O 3. V V N N V N egg O Q (P N P .�\ N O / N0.41119 % �• $'7 9I i PRCCUCT: Ooc--P—"Bin E;j R J PUSiPRO INC. L dOn F.sanmiat i�•• �•'•O F760G1ASS ODOR P.E.N0.A3+08 =N /�f 1f111111111� 2 2t 17 UPDA TO 6TN FD. 2077 FdC JK PARE OR A55F1A84Y; R Bl1RDIN0 CONBULTAM$,INC. 7 4 I9 UPDATE TO 5TH ER 2014 FBC JK P.O.Bot 230,Whim,FL 33595 ro NO DATE �/A710N5 PNon0 No.:813.059.9197 REVIb ONS FBPE CA No.9313 'e5 301 D R.W.O—.—COHYu4TaMH INo. "�—ErsB}1YP.} E 60 EXTERIOR (9 1i K EXTERIORbf a I/ a • �rII •.•.� i\\\4 �N fL Z " I/1111 11111 r ni' n$.1 K SEEN0M) mna'.€� 7 a= 40 INTERIOR INTERIOR 0 3a p 7 U'S a 21 20)— A 0p CCSUs+K 1s' EMB.gyp.) 2i 20 OYP.} }�^cam � 1.1/4"mut L (il'P.} EMB.TiYP.} B Cr4-"N C4-"NHORIZONTAL CROSS SECTION /S�HORIZONTAL CROSS SEC1iON ' =o E �—� y 5 ShO vn w/1XsubWc�sk r9�a;�� OuMvr+9si+own-insµing okoo(ipraved 1 NHORIL NT t CROSS SECAON 5 OubvMgshum biswingalsoapproved 1a Spadngterttemr-Cftomends ii 08 anddmoreequQUY zpaced otong EXTERIOR 00 M 27 EXTERIOR 9 K SEE NOTE I fe6te(tOtala). 10 K SEE NOTE I K $ry W d0 40 d0 7 d8 0 0 < INTERIOR 4NTERtOR g ro^z 0 wue 02 21 12 i 21 20 L 21 20 Wa N.T.S. 2 L OM m: JK n _ r3 HORIZONTAL CROSS SECTION ° °" ; 2 HORIZONTAL CROSS SECTION onu en�, a 5 0v! pstsovm-inswing aha approvad 5 Outsashorn-Inswing akoappsoved a: Strormvhlh2Xrclntoreemenl Slrownwllh2Xralntorcmhenl f't.-13184.1 ry d °' ° • .S. r C L 497Y 'm c; 40 \ I EXTERIOR INTERIOR 8 3a A C T 20 21 du iE 40 3 B = a & EXTERIOR INTERIOR 1 VERTICAL CROSS SECTION y j 20 21 OolswingMown-Inswing olSo approved 30 - 7 EXTERIOR INTERIOR �I ffi 2 VERTICAL CROSS SECTION Oolsv+csg shown-inswing also approved Shc.:nw Msub4 ,ck g C> .VERTICAL CROSS SECTION 8 INTERIOREXTERIOR 6. Shown WADA threshold , INTERIOR EXTERIOR R R v z INTERIOR EXTERIOR l a g040 / 31 7 E E 6 k� O aa° Ezo •° ° •a• c ,•c ata 02/21/12 O �--- - •'^ - ,'a seas N.T.S. � owa ssn JK e' /31 VERTICAL CROSS SECTIONVERTICAL CROSS SECTION 1-4 VERTICAL CROSS SECTION 6 l"ng conrgmatbn Q Shown w/O.S.ADA bump thmshold 6 OufsWing conngurohon a FL-77184.1 0 sem•'6 a J1 4 d - . 1.Spacing forRem K•C from each end 2 +A• e and of centerline 13 fofan. B X11 �� ,.p ,. �� .. .• �� N,�m O C z \ r8 9mo A ~ SEE NOTE 1 K 20 21 SEE NOTE I $ EXTERIOR INTERIOR EXTERIOR INTERIOR �1 VERTTCALCROSS SECTION o �� 7 Qum"shave I-nsw ng a�approved 2 VERTICAL CROSS SECTION 7 how 7,,Xs�ub-buc�k ng aho approved g E alz gl o a INTERIOR EXTERIOR m INTERIOR EXTERIOR INTERIOR EXTERIOR n J SEE NOTE 1 SEE NOTE I 5- SEE NOTE 1 K 20 21 F 34 E Do d • d" I a¢ r .� • • n • • - . ••O • • - _ • • � • • Ill —Z V 4 • d am 02121112 i to 3 VERTICAL CROSS SECTION 4 VERTICAL CROSS SECTION 6 VERTICAL CROSS SECTION ssuc N.T.S. s" 7 ww"conOguronon 7 Oulwftconugurotion 7 Ouls"configuollon 01°'W., JK 6 aM ee• LFS ; . OPAWNO HO.: N 6 FL-17 1 4* u b shtel 7 ur i t O 4, PYP.lTYP -{ ! - IttP.I nr a IIT �a '� I P. MP.) � - 'r g s g gzz if . 'm A:`a� II II II t Z S D �� II D ta� II II D k� g1a MASONRY IYP.HEAD I I HEA 6 JAMBSD I I I I YYP.HEAD CPENfNG B,JAMBS pMASONG II MASONRY I! II AlAMBS I I OPENING it 11 11 II a 11! II II iS 3 2XBUCK2XREIHFORCEMENT it I� f I ��a i P. .TX BUCK SHOWN FOR REF, MUCK 112X RHNfORCFMFNT I I }d ONLY I I SHOWN FOR REF. I I gi Y - II II ONLY II m 11 II II a - _ II �Q li �p II II II II II � ^Ifa BUCKANCHORING BUCK ANCHORING BUCKANCHORING 66 O E X OX/XO OXO E! � CONCREIEANCHOR NOTES: a� @ I. edge claelonnrhfonwidlakmjomolxgn arnoa,maybe aCinfed to maMfoM fne min �=2 C.,,.J da 1.n*Llo 9-cFi5 holed w'MA)L ON CENIEW myl bo a,._to mclybMThokdf0"Mdthe?lomodorENTE'c&wrwlm-1 wde o w C.Zl potredroemwe the�NA7f.ON CFNIFR'dmerdlon ore noretteeded o aConvefe arrlrorfaf>fe: o #NCNORI ANCHOR :�M1N MfN CLEARANCE.MIN C(FARANCE ry,,z TYPE (sITF FMBEDMEM 70 MASONRY lO ADJACENT_; . _ +: EDGE _- .ANCHOR; mm-02121172 - TA►CON 0 w 1/4'- 7 T/4 T T N.M ELCO JK 5p, UORIICON° 1/A• 1-1/4' 1' P CIR.eh LFS 3 bq' A WOODSCREWIMIALLATIONNOtM I.MaMbMafitM*num5/B' dedgeo cmflonddolanco.81'o.c.tpoctrgof I F1-17184.1 ry 0 b r:-�zmus to p.•c+znf the�.:.5•.a cfuxd: ���,� � 1 IClO1mOTo09pm.Lao(aNANkNfy1-FlNtic Pro9xi AgxweklCt-f]I0918;a�8 Com-InlMnO-0u4nb91�N31K•Dmer�gslN.'17189 L71ImR01711�L•171841<.pv41•ID 11' ��a837S I II 26'-�} 26• F•�26' 92S N N V W 2 O O O O ' a 32 x n In �c z n 7C S II n a 1 No.439D9 ' g q 4 �/av D1 PRODUCT; Ioacaaenre er•:,A•. PLISiPRO INC. LyndonF.Schmidt I• N FIBERGLASS DOOR PmE No.A3909 V Z± T 81W17 UPDATE TO 6TN EO 2017 F9C JK PART OR FJA9 YY; •/� BURDINO CONSULTANT--INC. 7 9 1:7 UPDATE TO2016 FUC JK J l��P.O.Box 230•Vairlco•FI.73693 ro NO DA By HAREWARE DEfiVCS YY Phone No.;813.65.9197 EVI I FSPE C.A.No.9873 0 30;2 R.W.Bui.........T�Nnr IHR. MUWGn' •., . mn b¢ _ 3'I1YP.11 WON 6•ITYPJ 7[YP � 3,(TYP.) I..t Q 6 Pa_ PP.)— ..l.L.. 5F -1 Y1Hr� 1 r,P 15 m° _v I i t t 1 I 7 �da`C. D e� _ z _ L 2XBUCK — — L 2X BUCK — 1XBUCK C1 �� MASONRY L 2XBUCK MASONRY HEAD O MASO� 0 J IX BUCF. OPENING . 1XBL.CK i� d OPENING TYP.O HEAP ANG _ U — 6 JAMBS — — — TYP.® — I JAMBS HEAD AND_ FRAME JAMBS Oo z o FRAME--\ FRL AME — — _ 2X BUCK TYP. 2X BUCK o hO I O TYP.®SN. TYP.@SILL 2X BUCK TYP.@ SILL TYP.0 SILL = 'L -JI t 1 L `tt � � t— � z FRAMEANCHORING FRAME ANCHORING R X VFRAME ANCHORING N OXO op CONCRVEANCHORNOM k t.Canaofe-dwbcaWm at fh�canon nW bo otpafod to and td.1h.min. edge dW i-I.maduphh. _ _ 2.Cbnfleb aKrKKbG'ofan[Iroled ofASAX UN CUl1EA•rtN1fItM c4wu to molnPdn the rift edge cWf to matvlotnb,cddbnofco fe afahm m rrioEbensePied Io emus dta'MAN ONCENtER'dimemo.va tai aiceedad 3.Cenwbanchor ratio w 'e a M7N.,ClfARANCE MM C[EARANGF m O ANCHOR ANCHOR -i MtN j MASONRY TO ADJA[ENI:;. a O a YYPE ; SPIE FMEEOMEM �EOGE '.' ANCHOR='.' TA oN` 4• 0 2 21 12 a N.T.S. EtCO1/P t•VPoRo.6e JK ITRACO `yf ON` m T t'CO m. LFS 3: w000soEWINSiABATfON M1fO1PS FL 17 t•Aa Wahemit blur R.-17184.1 =° MmdSC to proven 49j hno dafanrn.d l'me.tpOthg o! N muLr-�a1-I' O i BILLOFMATERIALS HEM If DFSGRPDON MA7tuAt A IX BUCK(SG>=0.42( WOOD B 2X BUC SSG>=0.2 WOOD �� S a n C 1/4"MAX.SHIMSPACE h Fes--2.36'----2.<--� j•.. 6 s D 17/ X 2.3/4"ELCO OR ITW CONCRETE SCREW STEEL 9'^m MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI YD HEA6&5iDE '�FFF1fl iTt TtTT�`, gHmg q E 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE JomD F 1/4"X2-1/4"PFK ELCO ORIIWCONCRETE SCREW STEEL 456" /4" en a dm G McX3-1PFHITWCONCRETESCREW STEEL I o 2.12' o va �aa� H 1/4'x3-1/4"PFHELCOOR HW CONCRETE SCREW STEEL ~ d r a J 1/4"X33/4°PFHELCO ORfIWCONCRETE SCREW STEEL B u gz K 09 X2-1/TPFH WOOD SCREW STEEL H S L 0 10X2-1/2"PFN WOODSCREW I.IS"MIN.EMBEDMENT) STEEL M BBXTPFHWOOD SCREW' STEEL S N 1/4"X1.3/4°PFHELCO ORITWCONCREIESCREW STEEL 7 FORCESWEATHERSTRIP(ENDURA) FOAM H�gDeSmE Y9 Lss�e P � 8. COMPRESSION WEATHERSTRIP QLON 650 SCHLEGEL FOAM Y1 PDNHFQ7 i$ 5 9 4"X 4'SIJU IRINGE STTS & 10 119 X 1"PFH WOOD SCREW STEEL g 11 B9 X 3/4".PFH WOOD SCREW STEEL �$ 20 FINGER JOINTED PINE FRAME,HEAD&HINGE JAMBS WOOD a� r.Y 21 LPOLY ATCHFIBERSTRIKE PL COMP./VINYL 456- 4,56• GI m 0 27 LATCH STRIKE PLATE STEEL 28 DEADBOLTSIR(KEPIATE STEEL 29 SIDEIJTESPACER ISSLB) PVC _I 30 DOOR SWEEP PVC m 31 OWSWING THRESHOLD BY DLP(QOSHI ALUM./WOOD 32 ADA THRESHOLD BY DLP(LSHC ALUM. OUTSWINO THRFSHOID MSWING THRESHOLD 33 INSWING THRESHOLD BY DLP L65 ALUM./WOOD 31 OoSH JJ 1sa „a 34- 51DEUTETHRESHOLD BY DLP(LSH/EIS) ALUM./WOOD H 35 TRIM WOOD 36 OUTSWING ADA BUMPTHRFSHOLD ALUM. 11 - F 1 40 1 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS S" 60 1 SIDEUTEPANEL-SEE SIDELTTEPANEL DETAILSHEET FOR CONSTRUCTION DETAILS (- 4.62" HH 88 2X REINFORCEMENT(CLEAR PINE:SG>=0.49) 1 WOOD [ a JY D T !VZZZZzZAi �IL f 6MC a< i � o � c SID—THAI g s— LSH1 —Z WE-02121112 z N.T.S. iowa ert JK o �UTSWING ADA BUMPWRESPOLDADA BUMPWRESPOLD L� 3 �OTHC FL oM —1177 n n FL— n sub if a ii ,a^ R W. R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.D.Box 230 Val rico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate.of Authorization No.9813 Proditet EvaltiationReport / / / 2017 Product Sub Category Manufacturer Product Name Category Plastpro Inc. Glazed Fiberglass Single Door. Exterior Swinging. Exterior Door 5200 W.Century.Blvd. w/or w/out Sideltes Doors Assemblies Los,Angeles,CA 90045Inswing/Outswing 440)969-9773 "Impact" Scope: Product Evaluation report issued by R W Building Consultants, Inc.&.-Lyndon R Schmidt, P.E. (System ID#1998)for Plastpro Inc.,based on Rule Chapter No..61 G20-3,Method 1 D of the.State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have,nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in.the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC),structural requirements excluding the"High Velocity Hurricane Zone". 2. Product anchors shall be as listed,and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing Or stucco. 3. When used in areas requiring wind borne debris.protection this product complies with FBC Sections 1609.1.2&R301.2.1.2 and does not require an impact resistant covering.This product meets missile level.."D"and includes Wind Zone 4 as defined in ASTM El 996 a.nd°FBC.Sections 1609.1.2.2-&R301.2;1°.2:1.. , 4. For 2x stud framing construction,anchoring of these units shall be the same.as that shown for 2x buck masonry construction: 5. Site.conditionsthat deviate from the details of drawing FL-17184.1 require further engineering analysis by a licensed engineer or registered architect.. 6. See drawing FL-17184.1 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 01391120' TAS 201-94,202-94&TAS 20.3-94 Testing Evaluation Lab.,lnc. Lyndon F.Schmidt, RE TEL-01390454 ASTM E1866-05/E1'996-06 Testing.Evaluation Lab.,lnc. V.K.Wright ASTM E330-02, E331-00 2. Miaml-Dade NOA Materials Testing 1:7-0712:04 Saflex®PVB Interlayers(Eastman Chemical Company) 3. Drawinq No. Prepared by Signed&Sealed by NO:.FL 17184.1 RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt, P.E. � Bs� 4 AnchoriCalculang RW Building Prepared yConsultants,Inc.(CA a°°�Q�'' /��g�®� LSigned ndon.F.Schmidt,9 ( ) ®®. . °•�•°.o..°; o� y P.E. 5. Quality Assurance Certificate ofPa-rticipation issued by National Accreditation and No 43409 o Management Institute,certifying that Plastpro Inc.is manufacturing products within a quality assurance program that complies vOth ISO/IEC 17020 and ° Guide 53. Gf' ate.o a� .,� • STATE ®�C •.•,po0®�Lyndon F.Schmidt,P.E. o� °a OR o •° ��o� FL PE No.43409 ,�®�B6s C)F1i~ t 00e 10/1012011 Sheet 1 of 1 ®AQaattaan,h�0