HomeMy WebLinkAboutLetter for slider at guard house Architectonic Inc St. Lucie County Planning & Development Services Building and Code Regulation Division 9EcE1VED June 21, 2018 JUN `�01W e,�nttdn9 D�artment St.Lude RE: Nettles Island Guard House To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed Aluminum Sliding Glass Door the 2017 Florida Building Code, 165 mph wind zone, exposure "D", risk category II. From Table 1609.3.1: Vu,t= 165mph Vasd= 128mph 6'-8" h x 6-0'w door which equals 40 s.f. From Table 1609.7(2); 15' mean roof height, Exposure D= 1.47 Required Design Pressures: ZONE 4- 27.5 x 1.47 = -40.4 ZONE 5- 31.5 x 1.47 = -46.3 Product: Series SGD-670 Aluminum Sliding Glass Doors w/90 degrees& 135 degrees corners-NI Product Pressures: -46.67 Product Approval # NOA 17-0420.09 Respe QI i�'t ' •9 ELJ8 r • • Michag Seal, AIA Archi n,.- AG,. .• ''G ED Aft 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg#AA26003348 1 of 1