To Whom It May Concern:
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed Aluminum Sliding Glass Door the 2017 Florida Building Code, 165 mph wind zone,
exposure "D", risk category II.
From Table 1609.3.1: Vu,t= 165mph
Vasd= 128mph
6'-8" h x 6-0'w door which equals 40 s.f.
From Table 1609.7(2); 15' mean roof height, Exposure D= 1.47
Required Design Pressures: ZONE 4- 27.5 x 1.47 = -40.4
ZONE 5- 31.5 x 1.47 = -46.3
Product: Series SGD-670 Aluminum Sliding Glass Doors w/90 degrees& 135 degrees corners-NI
Product Pressures: -46.67
Product Approval # NOA 17-0420.09