EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-118
One Owens Corning Parkway FL10674-1113
Toledo,OH 43659 Date of Issuance:02/06/2012
(740)404-7829 Revision 8: 10/09/2017
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance wit the a Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Owens C�ornin Asphalt Roo Shingles
LABEUNG: Labeling shall.be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions f the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes i igreement to notify Robert Nieminen,P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete
review of this Evaluation Report relative to updated Code requirement with each Code Cycle.
ADVERTISEMENT:The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displa ed,then it shall be done in its entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at tha request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
'Af",, 04; 'Me A'
Robert J.M.Nieminen P.E. %�' ?;ti;; The facsimile seal appearing was authorized by Robert
Florida Registration No.59156,Florida DCA ANE1983 Nieminen,P.E.on 10/09/2017.This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. Trinity lERD does not have, nor does it intend to acquire or will it acquire a financial interest in any company manufacturing or
distributing products,it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in ny company manufacturing or distributing products for
which the evaluation reports are being issued.
4... Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity lERD nor Robert Niemint n, P.E.are, in any way,the Designer of Record for any
I project on which this Evaluation Report,or previous versions thereof,is/wa used for permitting or design guidance unless retained
specifically for that purpose.
F)o
'\JTRIM Y I ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated
compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards.. Compliance is subject to the
Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
3. REFERENCES:
kn!fty Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
,Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shimeles: -
4.1.1 Classic'and Supreme'are'fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire7"are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration', TruDefinition' Duration' Duration' Premium Cool, TruDefinition' Duration' Designer Color
Collection,TruDefinition'Oakridge' Oakridge and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Hip&Ridge Shineles:
4.2.1 Berkshire Hip&Ridge Shingles, High Ridge,WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip& Ridge
Shingles and DuraRidgeTMl Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Accessory Starter Strips:
4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphatt Roof Shingles Revision 8:10/09/2017
Page 2 of 8
TRINITY ERD
5.4 Wind Classification:
5:4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7258,Class H,indicating the shingles are acceptable
for use in all wind-zones up to Vasd = 150 mph (V„n 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip hingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and 905.2.6.1 to ASTM D3161,Class F, indicating the
shingles are acceptable for use in all wind zones up to Vasa=150 mph(V„n=194 mph). Refer to Section 6 for
installation requirements to meet this wind rating- '
5.4.3 Classification by ASTM D7158 applies to exposure categoiy B or C,as defined in FBC 1609.4.3,and a mean
roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61620-3.
6. INSTALLATION:
i6_1 Underlayment:
6.1.1 . Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 61620-3,per FE C 1507.2.3,1507.2.4 or 11905.2.3.
6_2 Asphalt Shinales:
6.2.1 Installation of asphalt shingles shall comply with the Ow ns Corning current published instructions, using
minimum four (4) nails per shingle in accordance wit FBC 1507.2.7 or R905.2.6, with the following
exceptions:
➢ Berkshire shingles require minimum five(5)nails per shingle. -
➢ WeatherGuard*HP shingles require minimum six(6) iails per shingle.
➢ Devonshire'shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require m nimum five(5)nails per strip.
Refer to Owens Corning published information on wind r sistance and installation limitations. .
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 u lits horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip lus:
Felt underlayment Deck eels undedayment Detk S��h "
Self-adhered underlayment
WeatherLock®
underlayment
Drip edge
Drip_ Drip edge Drip
edge edge
I
Nails located ' 2•-'6�ae ve
2=3"from eave
Install fast Self-sealing adhesive Instal 6 ststartersimpP&M SdFsaafngadhesve
StarterStriPP •\ positioned along eave Vis. oved _• Postdoaedabngeave
shmgle with
6"removed StarterStnp I$-,airntangs eaves end rakes U4',r4'
Starter Strip shingle overhangs eaves and rakes'/P-s/i
i
i
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS
CertifrcateofAuthoraation#9503 6TM EDITION(2017)FBC NON-HVHZ EVAL ATION FL10674-1113
Owens Coming Asphalt Roof Shingic s Revision 8:10/09/2017
Page 3 of 8
TRINITY I ERD
6.2.1 Minimum Na(ling—TruUefinition�0akridge®,Oakridge®:
4 Nail Fattem 6 Nail Pattim
Esquema con 4 clavos Esquema con 6 clavos
1 1'
r r
i� tr —�►1 I<- 1z �I I it
Mir Fxposure Nails 5518"Exposure Nails
Siiposici6ndo55/8p+dg clavos EXPorial6ndeS6/8pulg 5WFxpgsule clavus 5liffExposure
Eliposiciort de 55/8 pufg Exposicign de 55/8 ping.
Standard Fastening Pattern 6-Nail Fastening Pattern
Fastening for Slopes Greater Than 21:12
sureNell�hstaning area wroth
Nae,Typical
Y 11• •{ . 12. 1•
6118•SS1B"
Four 1•Spots ofAsphafl Roofing Cotnant
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
�■ � � L2BI1/IrbL
!•i�6t�ilhwtph lYil lis
Clwi�wadfirdnt�dir
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R8
Certificate ofAuthoraation#9503 6t"EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017
Page 6 of 8
TRINITY I ERD
Minima Na lin ProEdge Hip&Ridg Shingles:
Prevailing Stan lard —tt'—►
Wind Direction Fast ning
Sealant Strip Patte m
�� S'Exposure T'� I.� �I`i I•z
12, I Sealant
Fasten Ph 71I=' 6"Exposure
'Cover Exposed 1 1 1
Fasteners with
Roof Cement
t
6.3.6 Minimum Nailing—DuraRidgeTm Hip&Ridge Shingles:
Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requi ements.
PrwmifngWindDincticn Top V1 w
Diracdondomirantedivan[ I �RM�prt�or
Diroce6ndo]viintoprwic nimnto I" nPe
p cis
�` �,�Oeicns Coinng SurcHail.•, =:�- Qa,o
Carovlow
..
a«
. m 4 t
I:
" �IY —�
i 7. LABELING:
7A Labeling shall be in accordance with the requirements he Accredited Quality Assurance Agency noted
herein.
71 Asphalt shingle wrappers shall indicate compliance with ne of the required classifications detailed in FBC
Table 1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdictio ri in order to properly evaluate the installation of
(, this product.
I
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants pr duce products covered by Florida Rule 9N-3 QA
requirements.
10. QuAuTY ASSURANCE ENTITY:
UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul. om
- END OF EVALUATION REF ORT-