HomeMy WebLinkAboutProduct Approval (3) BCIS Home I Log In I User Registration Hot-ropics I Submit Surcharge Stat!&Facts Publications I Contact Us I BCIS Site Map I Links Search 1
Florida
` a
Product Approval
USER:Public User
8a`F
Product AQ12royal Menu>Product or Application Search>Application List>Application Dewil
FL# FL5259-R28
Application Type Revision
Code Version 2017
+ Application Status Approved
Comments
Archived CJ
Product Manufacturer POLYGLASS SA
Address/Phone/Email 1111 W. Ne
1 port Center Drive
Deerfield BeZh,FL 33442
(954)233-1178 Ext 242
alender@pol glass.com
i
i
Authorized Signature Ariel Lender
alender@pol glass.com
Technical Representative Maury Alpert
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Be ch,FL 33442
(912)429-8610
MAlpert@pol glass.com
Quality Assurance Representative Ariel Lender
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Be ch,FL 33442
(954) 233-1230
ALender@po yglass.com
i
Category Roofing
Subcategory Underlaymei is
Compliance Method Evaluation R aport from a Florida Registered Architect or a Licensed Florida
Professional Engineer
1
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Niem nen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/05/2018
Validated By John W.Knezevich,PE
(J
Validation Checklist-Hardcopy Received
i
j Certificate of Independence FL5259 R28 COI 2018 01 COI NIEMINEN.od
Referenced Standard and Year(of Standard) Standard Year
ASTM D19710 2015
ASTM D226 2009
ASTM D4798 2011
ASTM D6164 2011
ASTM D622 2011
FM 4474 2011
FRSA/TRI A ril 2012 2012
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 01/24/2018
Date Validated 01/29/2018
Date Pending FBC Approval 01/30/2018
Date Approved 04/10/2018
Summary of Products
FL# Model,Number or Name Description
5259.1 Polyglass Roof Roofing underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL5259 R28 II 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
Approved for use outside HVHZ:Yes R28.pdf
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes
Other: 1.)The design pressure in this Evaluation Reports
application relates to one particular FL5259 R28 AE 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
underlayment system(over concrete deck)for R28.p ,df
use under foam-on tile systems(where the Created by Independent Third Party:Yes
underlayment forms part of the load-path).
Refer to ER Section 5.6.4 for other systems,
other deck types and associated maximum
design pressures.2.)Refer to ER Section 5 for
other limits of use.
Back Neat
Contact Us::2601 Blair stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emai Is
provided may be used for official communication with the licensee.However email addresses are public record.If you do notwish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® EChr"ck M
Credit Carel
Safe
i
N E W etc.
Certificate ofAuthorization#32455
353 Christian Street, Unit#13
Oxford,CT 06478
(203) 262-9245
ENGINEER' EVALUATE TEST CONSULT CERTIFY
EVALUATION REPORT
Polyglass USA,Inc. Evaluation Report P12060.02.09-R24
1111 West Newport Center Drive FL5259-1128
Deerfield Beach; FL 33442 Date of Issuance:02/24/2009
(954)233-1230 Revision 24:01/24/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicab a rules and regulations governing the use of
construction materials in the State of Florida.The documentation submittd has been reviewed by Robert Nieminen, P.E.
for tuse.of the product under the Florida Building Code and Florida BuillIding Code, Residential Volume. The products
described hereinhave been evaluated for compliance with the 6`I' Editidn (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass'lRoof.Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that r late to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). MEMOJetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEIVIO I etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the reque t of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
Ro�.M.Nieminen,P.E. � -sia?"; - w
The facsimile seal appearing was authorized by Robert Nieminen,
Florida Registration No.59166,Florida DCA ANE1983 •'.'� s y` P.E.on 01/24/2018.This does not serve as an electronically
tom,. signed document-
CERTIFICATION
ocumentCERTIFICATION OF INDEPENDENCE:
1. INEMOIetc. does not have;-nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. 1NEMO I etc.is;not owned,operated or controlled by any company manufacturi g or distributing products it evaluates.
3. ;Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
!which the evaluation reports are being issued.
4. !Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in an other entity involved in the approval process of the
'product.
5. 'This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen,P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was u ed for permitting or design guidance unless retained
specifically for that purpose.
ONEMO etc.
Enti Examination Reference Date
ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012
ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013
ERD(TST 6049) Physical Properties P45370.04.13 04/26/2013
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013
ERD(TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013
ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013
ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013
ERD(TST 6049) Physical Properties P45270.05.14 05/12/2014
ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-2 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-3 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-4 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-6 09/08/2014
ERD(TST 6049) Physical Properties P46520.10.14 10/03/2014
ERD(TST 6049) Physical Properties P43290.10.14 10/17/2014
ERD(TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015
ERD(TST 6049) Physical Properties P40390.04.15 04/03/2015
ERD(TST 6049) Physical Properties P44360.10.14-R1 05/18/2015
ERD(TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015
ERD(TST 6049)' Wind Uplift PLYG-SC8905.05.16-1 05/17/2016
ERD(TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016
ERD(TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD(TST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016
ERD(TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017
ERD(TST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017
ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014
Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/LAffidavit Mule-Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.10/05/2018
4. PRODUCT DESCRIPTION:
4.1 Mechanically,Fastened Underlayments
4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass-reinforced,asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass-reinforced,APP modified bitumen base sheet.
4.2 Self-Adhering Underlayments:
4.2.1 Polystick MTS or Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass
fiber reinforced,surfaced with polyolefinic film surface;meets FRSA/TRI April 2012.
4.2.2', Polystil&1111- is a,nominal 60-mil` hick rubberized,,asphalt waterproofing;membrane,glass fib'r,,remfo'rced,with an
aggregate surface meets ASTM D1970. .
4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a
polyester fabric surface;meets ASTM D1970 and FRSA/TRI April 2012.
NEMO ETC,LLC. Evaluation Report P12060.02.09-R24
Certificate of Authorization#31455 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-R28
Polyglass Roof Underlayments;(954)233-1230 Revision 24:01/24/2018
Page 3 of 14
I
ONEMOjetc.
5.5 Allowable Roof Covers:
TABLE 1 ROOF MVER,OPTi NS"
Wood Shakes
Underlayment Asphalt Shingles Nail-On Tile Foam-Oi i Tile Metal Slate
&Shingles
Elastobase Yes Yes Yes ye yes Yes
- 4 (Base Sheet in 2-plysystem) (Base Sheet in 2 ply system)
Elastobase P Yes Yes Yes Yes Yes Yes
' (Base Sheet in 2-ply system) (Base Sheet in 2 ply system)
Polyglass G2 Base No Yes Yes No No No
(Base Sheet in 2-ply system) (Base Sheet in2ply system)
Polyglass APP Base No Yes Yesi No No No
(Base Sheet in 2-ply system) (Base Sheet in 2 ply system)
Polystick MTS or MTS PLUS Yes Yes No Yes Yes Yes
(,Polystick 1R Xe,°." ;x, Yes 'r NoNo ,, ';' „ No Yes Yes
PalystickTU P No Yes Yes (See .5.1) No No No
Polystick TU Plus Yes Yes .Yes (See .5.1) Yes Yes Yes
. PalystickTU Max No Yes Yes (See .5.1) Yes No No
Polystick Dual Pro Yes No No Yes Yes Yes
i
Polystick Tile Pro Yes Yes Yes (See 5.5.1). Yes Yes Yes
Polystick MU=X Yes No No Yes Yes Yes
Elastoflex S6 G Yes Yes Yes (See .5.1) No Yes Yes
Elastoflex S6 G FR Yes Yes No No Yes Yes
Elastoflex G TU Yes Yes Yes (see .5.1) No Yes Yes
Polyflex G Yes Yes Yes (See .5.1) No Yes Yes
Polyflex G FR Yes Yes No No Yes Yes
Polyflex SAP or SAP FR Yes Yes Yes (See .5.1) No Yes Yes
Mule-Hide SA-APP Cap Sheet Yes Yes Yes (See .5.1) No Yes Yes
or SA-APP Cap Sheet(FR)
i
.5.5.1 ""Foam-On Tile"is limited to use of the following Approved the adhesives/underlayment combinations.
I
'TABLE IA:ALLOWABLE TILEQDHESIVE/UNDE YMEM'COMBINATION51
Adhesive Florida Product Underlayments
Approval
i DAP Foam Touch'n Seal StormBond Roof FL14506 Polystick TU Plus Polystick TU.Max
Tile Adhesive
Dow TileBond'". FL22525 Polystick TU P,Polystick TU Plus,Polyflex SAP or Tile Pro
Polystick TU P,P lystick TU Plus,Polystick TU Max,Polystick Tile Pro,
ICP Adhesives Polyset®AH-160 FL6332 Elastoflex G TU, lastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR,
Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
Polystick TU P,P lystick TU Plus,Polystick TU Max,Polystick Tile Pro,
ICP Adhesives Polyset®RTA-1 FL6276 Elastoflex G TU, lastoflex S6 G,Polyflex G,-Polyflex SAP,Polyflex SA Cap FR,
Mule-Hide SA-A P Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)
I
I
' i
- I
i
i
i
I
1 Refer to 711e Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
MEMO ETC,LLC. Evaluation Report P12060.02.09-R24
Certificate of Authorization#32455 678 EDITION(2017)FBC NON-HVHZ EVALUATION FI5259-1128
Polyglass Roof Underlayments,(954)23 1730 Revision 24:01/24/2018
Page 5 of 14
OMEMO I etc.
5.6 Allowable Substrates:
5:6.1, Dlrec B d to Deck;
Polystick(all variations),Dual Pro,Tile Pro,Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR)self-adhered to:
➢ New untreated plywood;ASTM D41 primed new untreated plywood; Existing plywood;ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note:Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch-applied to:
➢ ASTM D41 primed structural concrete.
5.6.2 Bond-to-Insulation:
Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR) self-adhered
to:
➢ ASTM C1289, Type 11, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard;Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
Polyflex G or Polyflex G FR torch-applied to:
➢ ASTM D41 primed structural concrete;Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick(all variations), Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR) Dual Pro or
Tile Pro self-adhered to:
➢ ASTM D226,Type I or II felt;Elastobase;Elastobase P or Mule-Hide Nail Base.
Elastoflex G TU,Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D226,Type I or II felt;Elastobase;Elastobase P,Mule-Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch-applied to:
➢ Elastobase;Elastobase P,Mule-Hide Nail Base,Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012(04-12),Appendix A,Table 1,or as listed in Section 5.6.4 herein,or as tested in
accordance with FBC Section 1504.3.1.
NEW ETC,I.I.C. Evaluation Report P12060.02.09-R24
Certificate ofAuthorization#31455 fiEDITION(2017)FBC NON-HVHZ EVALUATION FL5259-1128
Polyglass Roof Underlayments,(954)233-1230 Revision 24:01/24/2018
Page 6 of 14