Loading...
HomeMy WebLinkAboutProduct - Single hung ,Florida Building Code Online CJI ' �' `�G Page 1 of 2 � A a' SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats®Facts Publications Contact Us DCIS Site Map Links Search db'pr 4 Product Approval USER:Public User Product Aooroval Menu>Product or Application Search>Application List>Application Detail FL# FL19715-R4 Application Type Revision Code Version 2017 Application Status Approved 1 q R Y+ PY Comments Archived Product Manufacturer Silver Line Building Products Corp. Address/Phone/Email One Silverline Drive North Brunswick,NJ 08902 RECEIVED(651)264-4178 Nicholas.Kopp@andersencorp.com JUL 10 2018 Authorized Signature Nicholas Kopp Nicholas.Kopp@andersencorp.com permitting Department St.Lucie Col Technical Representative Jon Berrian Address/Phone/Email One Silverline Drive North Brunswick,NJ 08902 (732)435-1000 jonberrian@slbp.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Hermes F. Norero,P.E. the Evaluation Report Florida License PE-73778 Quality Assurance Entity Window and Door Manufacturers Association-QA Quality Assurance Contract Expiration Date 12/31/2019 Validated By Locke Bowden P.E. Validation Checklist- Hardcopy Received Certificate of Independence FL19715 R4 COI COI Silverline SS 2017-06-14.0f Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2011 AAMA/WDMA/CSA 101/I.S.2/A440 2008 ASTM E1886 2005 ASTM E1996 2012 ASTM E330 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 ' Equivalence of Product Standards Certified By https://floridabuilding.org/pr/pr_app_dtl.aspx?param=WGEVXQwtDgtvAD/o2bxmzk 1 hGufB... 7/9/2018 ,Florida Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/18/2017 Date Validated 12/18/2017 Date Pending FBC Approval 12/29/2017 Date Approved 02/13/2018 Summary of Products FL# Model,Number or Name Description 19715.1 Series 2900/4900 Single Hung Extruded Vinyl Single Hung Window Limits of Use Installation Instructions Approved for use In HVHZ:No FL19715 R4 II SWD002 SS 2017-12-15.Ddf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E.Florida P.E. 73778 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Installations Instructions and Product Evaluation FL19715 R4 AE PER5375 SS 2017-12-15.odf Report for design pressure tables and limitations of use. Created by Independent Third Party:Yes 19715.2 Series 2900/4900 Single Hung Extruded Vinyl Single Hung Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL19715 R4 II SWD012 SS 2017-12-15 odf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero Florida P.E.73778 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Installations Instructions and Product Evaluation FL19715 R4 AE PER5376 SS 2017-12-15.pd Report for design pressure tables and limitations of use. Created by Independent Third Party: Yes 19715.3 Series 70 Model 2127 Single Hung Extruded Vinyl Single Hung Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL19715 R4 II SWD010 SS 2017-12-18 Ddf Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero Florida P.E.73778 Impact Resistant:No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Installations Instructions and Product Evaluation FL19715 R4 AE PER4805 SS 2017-12-18.Ddf Report for design pressure tables and limitations of use. Created by Independent Third Party:Yes 19715.4 Series 70 Model 2127 Single Hung Extruded Vinyl Single Hung Window Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL19715 R4 II SWD011 SS 2017-12-18 Ddf t Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero Florida P.E.73778 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See Installations Instructions and Product Evaluation FL19715 R4 AE PER4806 SS 2017-12-18.[)d Report for design pressure tables and limitations of use. Created by Independent Third Party: Yes Back Nez - Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.if you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Credit Card Safe https://floridabuilding.oriz/t) r_app_dtl.aspx?param=wGEVXQwtDgtvA%2bxmzk1hGufB... 7/9/2018 Silver Line m SILVER LINE BUILDING PRODUCTS ��'� ' V1 SERIES170 SERIES SINGLE HUNG WINDOW (2127) NO ONSIITH UNSWICEDRIVE02 PH.BDD 2MA22B (IMPACT RA TED) z Z I'I N ab aQR P.?2 W— OmLL .g g; o= o ?a No Q � a O Z Q w Z 1 3 GENERAL NOTES: Z z ; 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MAX OVERALL SIZE TABLE OF CONTENTS N= m Co DESIGN MISSILE MANUFACTURED TO COMPLY WITH THE 6TH EDITION CONFIG. j W a FLORIDA BUILDING CODE(FBC),INCLUDING HVHZ AND HAS WIDTH HEIGHT PRESSURE IMPACT RATING SHEET REVISION SHEET DESCRIPTION BEEN EVALUATED ACCORDING TO THE FOLLOWING: �++ i • TAS 201-94 52" 73" O/X +55/-60 PSF LMI/SMI 1 GENERAL NOTES&GLAZING DETAIL F i • TAS 202-94 2 - ELEVATION&ANCHOR LAYOUTS • TAS 203-94 • REMARKS BY DATE ASTM E330-02 3 - VERTICAL SECTIONS • ASTM E1886-05 6TH TBC EDITION lM06/141171 • ASTM E1996-06/09/12 4 - HORIZONTAL SECTIONS • AAMA/WDMA/CSA 101/1.5.2/A440-085 REINFORCEMENT DETAILS HORIZONTAL&VERTICAL SECTIONS,INSTALLATION NOTES& 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY,2X FRAMING,AND METAL FRAMING AS A MAINWIND FORCE RESISTING SYSTEM CAPABLE Of u+D SHeuxor se umoou¢ow wxa[ax vun WITHSTANDING AND TRANSFERRING APPLIED PRODUCT unx•inrs.•oomaxz xls«WHnxs, w••orrsro tars oocuxcxrnBE xm vE•Mrt1FDNO LOADS TO THE FOUNDATION 15 THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. Re..nsigned111 by qT grP,s�F�.No ero,Te t 43/64"O.A.I.G.LAMINATED GLASS Reason I �,lA�k"l,mg hMgp�pment Date 2Eyc� �38`J5 (j50?7,, 3. 1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND CONSISTING OF: ♦ 1 i ANCHORED AS SPECIFIED HEREIN.REFER TO SHEET 5 FOR 1/8"ANNEALED GLASS `��Q' •<C,p��� FURTHER DETAILS OF BUCK INSTALLATION. �{ 7/32 STEEL SPACER S.Z• •• �•O I 0 ANNEALED GLASS 0.09 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE 0.090"SAFLEX PVB INTERLAYER BY GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR EASTMAN CHEMICAL COMPANY A SPECIFIC SITE.IF SITE CONDITIONS CAUSE INSTALLATION 3/32"ANNEALED GLASS :• T T ;' TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, Q •• ( P;' 4Q F A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT INS'S •���� NON-HVHZ AREAS.IN HVHZ AREAS,ONE TIME PRODUCT \ / �ONA1-E IL APPROVAL TO BE OBTAINED FROM MIAMI-DADE RER OR EXTERIOR / INTERIOR luto, .%%0 g AH,. I BUBLE O DROPS. e 5. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED I zs c Dwu BM BEw. w ON THIS PRODUCT IN AREAS REQUIRING IMPAR �A HO EL STEEL SPACER EBPE artT.a urntaaIZATwN Nn 2aB7e 8 RESISTANCE. \ � FL p: MIN.GLASS F L 19 715 6. WINDOW FRAME MATERIAL:PVC OR 3/32" BITE 7/16" SETTING BLOCK 7. IN ACCORDANCE WITH THE 6TH EDITION FBC,WOOD DOW 995 SEALANT DATE: 12.11,17 COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED DWG.BY: CHK.BY: OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN CHAPTER 23. GLAZING DETAIL 1 LMS I HFN B. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 NOTE: SCALE: NTS GLASS CHARTS.SEE SHEET 5 FOR GLAZING DETAILS. ALL GLAZING CONFIGURATIONS SHALL COMPLY WITH DWG.8: SWD011 SAFETY GLAZING REQUIREMENTS OUTLINED IN SHEET: CURRENT FBC AND ASTM E 1300 GLASS LOAD RESISTANCE. OF 5 Silver Line r MAndd&h ONE SILVERONE DRIVE NORTH BRUNSWICK,N108902 PH:(8031 2346228 w L^ U m MAX.O.A FRAME y Zm WIDTH 52" N 5 a o m Q MAX.D.L.O. WIDTH 47.69" w0 = A B 3"MAX. 6"MAX. 6.25"MAX. 4 o z p m ' 3 3FROM O.C. FROM F-- I^3 ^n o o>? CORNERS�r C F jORNERS I W _ O °�z m NOTE: >_ o `� ALL FASTENERS ABOVE ,. MAX.D.L.O THE MEETING RAIL IN d D THE INTERIOR IAMB r 4 6"MAX. TRACK MUST BE FLAT HEAD ~' . "O" HEIGHT 33.50" G D.C. I REMARKS BY DATE a L 6TH f8C EOR10N LM 06/14/17 12.50"MAX. O.C. MAX.O.A FRAME HEIGHT 73" MFo Sl:r H ur Z BH RFPRooua wNnFN MF —rnNSFNT NLwnc AITE wror`s.Mi.c Ao .1 RwiDxnNr,aR mi<A M,MNNGS iO iH1H.DODUNI NDi PFIWIiEDUID MAX.D.L.O. "X" 3"MAX. 6.25"MAX. I ' 1 OUR anIXT'ON, HEIGHT 33.50" FROM FROM E CORNERS CORNERS ��OeSF Ii1OI���'i ELEVATION ANCHOR LAYOUT ANCHOR LAYOUT SINGLE HUNG WINDOW NAIL FIN-SINGLE HUNG WINDOW THROUGH FRAME-SINGLE HUNG WINDOW s,/Ip,NA1- G%��`` FLORIDA PE Na]J]1B SBB E BARBA WM2F DANIA BfACN.R 3.1001 f1iPE MT.OF AUTFOM2ATI011 Nc 295]B g FL#: FL19715 � DATE: 12.11.17 Y DWG.BY: CHK.BY: LMS I HFN SCALE: NTS t owG.a: SWD011 SHEET: OF 5 Silver Line byAnWrien s ONE SILVERLME DRIVE NORTH BRUNSVWX NI 08901 PH:800 1361118 Z m n E� 0 om a< W 3 SEE GLAZING SEE GLAZING In Z Z s<a DETAIL,SHEET 1 DETAIL,SHEET 1 _W 3 l7 c 0 0 �> > oma 0 o w; c z a I- a REMARKS BY I DATE 6TH FOC EDITION LM 06/16/17 � l7 W — x = EXTERIOR INTERIOR EXTERIOR INTERIOR a a J� po s�Mu Nor eE REmoo�,a Q MTpvMii _E F^. M6OpxGSTO in SBODO[uMEN! S F u/0���4i 0 0 7 *� E SEE GLAZING SEE GLAZING fDETAIL,SHEET 1 DETAIL,SHEET 1 ��0�'•.• ( P;' <4�� ' I HERItl� ` IF U Duce I)D N. sa s / / DRros ne iBPE CIE NT. CI ow3�sti`>Ot E JtT.OE AU1HOPolAT1011 Na 12 83]8 � O 0 FL q: FL19715 � DATE: 12.11.17 $t DWG.BY: CHK.BY: # SCALE: NTS DWG.#: SWD011 VERTICAL SECTION VERTICAL SECTION SHEET 3 3 0F 5 a Silver Line �2nE,aOSM; ONE SILWRLB/E MW NORTH BRUNSWICK,N208902 PH:800 22 228 SECTION FOR INTERIOR SECTION FOR n N aa BLOCK&TACKLE SEE GLAZING SEE GLAZING CONSTANT FORCE .`+ o R e BALANCERS o DETAIL SHEET 1 DETAIL SHEET 1 �o� BALANCERS w" 0 _} / \I N$ MIA, 0c�, Q Z 181.1 � O � 2 Z N� _ �m \ EXTERIOR o, D.L.O. - ¢ r a REMARKS BY DATE MAX.FRAME WIDTH - ---- 6TH FK EMON LM a/14/17 HORIZONTAL SECTION 4 FILLED JAMB N*TEn COxIIHT OE Bu�EgxG OmPS nC. SEE GLAZING SEE GLAZING INGS TOTHISR—MENT=-K'=nTDLD fDETAIL SHEET 1 INTERIOR DETAIL SHEET 1-\ '' cc z EXTERIOR �` ••.....•• P ','���SS�O D.L.0. NAI 4NLWEaw¢` RLOBOA RL"73M 3 mi MOPS T 8M L DANIA BEAa BLW./118 MAX.FRAME WIDTH F�CM OF TMw ON SM MINN.MM L p: HORIZONTAL SECTION FL19715 e FIXED JAMB DATE: 12.11.17 �$ DWG.BY: cHXHFN SCALE: NTS DWG.Jr: SWD011 SHEET: 'V OF 5 MIN. SUBSTRATE 1/4"MAX.SHIM SPACE SUBSTRATE MIN.EMBEDMENT SUBSTRATE Silver Line EDGE DISTANCE BY OTHERS 3 BY OTHERS INTERIOR BY OTHERS MAnde'rseri SCREW IN THE INTERIOR CHANNEL MIN. MIN. EDGE DISTANCE EMBEDMENT l7 v ONE SILVERUNE DRIVE SCREW IN THE EXTERIOR z NORTH BRUNSWICK,W 08901 CHANNEL Z 4 PH:SWw 13 228 PERIMETER SEALANT 1/4"MAX f w BY OTHERS SHIM SPACE PERIMETER SEALANT zo Z BY OTHERS 1/4'MAX. z EXTERIORMIN. SHIM SPACE N F t OEXTERIOR INTERIOR Q EMBEDMENT EXTERIOR INTERIOR o o I,Y w i q VERTICAL SECTION W z ~=Z g HORIZONTAL SECTION C HORIZONTAL SECTION = s o t 6 THROUGH FRAME(HEAD) 6 THROUGH FRAME(JAMB) 6 3 °�g o NAIL FIN(HEAD) Z m$ n= p?¢ m 1/4"MAX. REINFORCEMENT DETAILS o \a Irw SUBSTRATM SPACE u; _ \� a BYOTHERS 0.34 t d 0.83" I0.87" I{7 INTERIOR �'�. L-�'� REMARKS BY DATE W Z 0.77" �.i 06/ 6TH FBC EDITION LM 11/17 INTERIOR T7� 0.46" o 0.06" 0.87"EXTERIOR 0.45" m f rLOCK RAIL LOCK � I EXTERIOR 1 O ALLUMIINUMOP O ALUM NUMNG RAIL O ALUMINUM RAIL &SASH DKNroN:ENTDFau�NBRM�. MG,OR rungERV... N wc�mE,NT o MIN.EDGE DISTANCE `11111 HORIZONTAL SECTION �,`1`0Es F. 0 � VERTICAL SECTION 6 NAIL FIN(JAMB) 6 MEETING STILE :�lv�,• �p'i INSTALLATION NOTES: ANCHOR SCHEDULE ']•�_ c METHOD SUBSTRATE ANCHOR SCHEDULE MIN EMBEDMENT MIN.EDGE 8 1. ONE(1)INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. DISTANCE F 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR WOW:MIN.SG:0.55 'yB WOOD HHEAD ,.s O.TS• �0� p.;•� w;: PRODUCT INSTALLATION OF THE MAXIMUM SIZE LISTED. NAILING FIN �MIN , F 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN ATOLERANCE OF±1/2 INCH THE DEPICTED LOCATION& M�MN.Fy=333KSI ��K� PENETRA�TIONSBEYOND o0.50• NAL METAL SPACING IN THE ANCHOR LAYOUT DETAILS(I.E.,WITHOUT CONSIDERATION OF TOLERANCES).TOLERANCES ARE � ,IaE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. EXTERIOR#10 PAN HEAD IN 1.5• 0.75• Biw�Mo°oR :� >W E DANA BEAW BLW./]Y 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S).MAXIMUM ALLOWABLE SHIM WOOD:MIN.50=055 POPE�W AURA CIPI t�76 STACK TO BE 3/8 INCH.SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS.SHIM(S)SHALL BE CONSTRUCTED kIN FLAT HEAD IN THE INTERIOR DHANNEL ,.5• D.Ts FL" FL19715 OF HIGH DENSITY PLASTIC OR BETTER. ~ k10 PAN HEAD IN 3 THREADS MIN S. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES,INCLUDING BUT NOT LIMITED TO STUCCO, PENETRATION BEYOND o.w• FOAM,BRICK VENEER,AND SIDING. ExrERKM CHANNEL METAL 12.11.17 F THROUGH FRAME METAL 1B GAUGE SMN, DATE: $ MIN.Fy=33KSI 3 THREADS MIN 6. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR #10 FLAT TH AD I NTHE PENETRATION BEYOND o.30' DWG.BY: CHK.BY: HAVE A CORROSION RESISTANT COATING. METAL LMS H FN 7. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK,DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. CONCRETE:f--3000PS1 3/1s ETM'TAPCONFLAT HEAD 126, 1.76' SCALE: NTS EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. DWG.p: S A/DO1 9 B. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION RY.CMU PRI ASTMtits ITW TAPCON 1.25• 175• SHEET: J V V 11 INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM CBO MW.2000 PSI FLAT HEAD STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 9. FOR INSTALLATION ANCHORS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK,USE FLAT HEAD ANCHORS. OLF5