Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
Michelle Franklin, CFA --Saint Lucie County P rope rty Appraiser --All rights reserved. Property Identification SiteAddress: Parcel ID: Account #: Map ID: Use Type: Zoning City/County: Ownership Ruth D Prickett (LF EST) 367 SE GrasparillaAVE Port St Lucie, FL 34983 Legal Description RIVER PARK -UNIT 4 BLK 37 LOT 19 (MAP 34/28N) (OR 3397-68; 3432-2901;3606-991) Current Values Just/Market Value: $119,400 Assessed Value: $119,400 Exemptions: $75,500 Taxable Value: $43,900 Taxes for this parcel: SLC Tax Collector's Office 12 Download TRIM for this parcel: Download PDF 0 367 SE GASPARILLAAVE 3419-530-0147-000-5 42547 34/28N 4100 RS -4 Saint Lucie County Total Areas Finished/Under Air (SF): 1,261 Gross Area (SF): 2,034 Land Size (acres): 0.29 Land Size (SF): 12,600 This information is believed to be correct at this time but it is subject to change and is not warranted. (D Copyright 2018 Saint Lucie County Property Appraiser. All rights reserved. 3121 Skyway Circle Suite F Melbourne FL 32934 CONTRACT Southeast Contractors Group, Inc. PROPOSAL SUBMITTED TO: Date: /-/I / ZIob Name: Customer: job Location: Office. (877)407-3535 Fax: ($77) 756-0007 www.southeastcontracting.com CGC060247 . CCC1330002 Phone: rs-- f b - Email: JOB DESCRIPTION: Remove existing roofing and install new asphalt shingles Shingle Color:J'-._,. /� Drip Edge Color: ATLAS PRISTINE PINNICLE: x • Provide roofing permit • • Provide trash removal to a legal off-site facility Install all new valley metal I6" 26ga set in plastic roofing cement. (If required) • Remove existing roofing do to the wood deck • • Replace all bad decking (sheets included additional sheets Install new drip edge'x 3" aluminum Install • billed at $80.00 each) • • Re -nail deck as required by Hurricane Mitigation Retrofit Manual new Low Profile Ridge Vent/Cobra Ridge }Tent X Install new exhaust vents (Galvanized) and lead boots • (Based on 553.844 ES.) • • Install ATLAS Summit 60 underlayment Install ATLAS PINNACLE STARTER SHINGLE Install ATLAS PINNACLE PRISTINE PRO -CUT • Install ATLAS PRISTINE LIFETIME 130 MPH SCOTCH GUARD SHINGLE $ ADDITIONAL ITEMS: • Install ATLAS Weather Master SA underlayment in valleys and eaves $ • Install ATLAS weather Master SA underlayment on entire deck (Recommended) Qualifies as a Secondary Water Resistance (SWR): $ J G SWR (also called Sealed Roof Deck) Self -adhering polymer modified -bitumen roofing underlayment applied directly to the sheathing or foam adhesive SWR barrier (not foamed -on insulation) applied as a supplemental means to protect the dwelling from water intrusion in the event of roof covering loss. • Install Atlas Gorilla Guard 30 Engineered Felt on entire deck $ FLAT ROOF: • Provide roofing permit • Provide trash removal to a legal off-site fad ty • Remove existing roofing down to the wggd ec • Replace all bad decking (�sheeEs�in u billed at $80,00 each) � • Re -nail deck as required by Hurd ie'Mitigati (Based on 553.844 F.S.) a' Notes: , Install CERTAINTEED ALL WEATHER EMPIRE BASEIPLY r/ • Install CERTAINTEED FLINTLASTIC-GTA CAP SHEET d r • Install new primed drip edge 3: x 3" aluminum with Matrix " 201 anal s Premium SBS Flashing Cement • Install new metal 16" - 269a set in Matrix – 201 Premium SBS Manual Flas ing Cement at sloop roof tie-in 'le- C- —)i A•uAi6 WIND MITIGATION: ) • Southeast General Contractors Group, Inc. will provide a Wind Mitigation Report for an additional fee of $$ {il?C�],�/ NOT INCLUDED: ADDITIONAL ITEMS; Gutters Plywood:..................................................... . Cost $80.00 per sheet labor and material Metal fascia trim Fascia;........................................................... .. .. Cost $18.80 I/flabor and material Metal roof structures Second layer removal: ................................ Cost $28.00 per square Satellite dish removal or replacement Chimney flashing: ...................................... Cost $225.00 plus stucco if required at $37.54 per s/f Screens and screen enclosures Flashing, step, counter or base: ................ Cost $17.251/f labor and .material Solar heater removal or replacement Gutter removal: .................. Cost $ .50 ....................... . Skylights Rafter tail repairs: ....................................... Cost $120.00 each Truss repair Skylight replacement and flashing:.......... Cost $475.00 each Stucco repair ............................................... Cost $37.50 per square foot GENERAL TERMS AND CONDITIONS Change Orders, contractor may accept a `change order" to the plspe ans, cifications or equipment. In addition, the total price increased or decreased to reflect the change, and the same shall be in writing and signed b�v the owner and Contractor. Any increase to the contract price shall be paid by the Owner upon ordering the work called for in such–change order or upon execution of the change order as required by the contractor. Southeast General Contractors Group, Inc. is responsible for completion of work in compliance with contract documents and for quality of material and workmanship in accordance with standard specifications. Labor Warranttyy/5 year on workmanship. Material Warranty 30 -year limited warranty. Same a Cash (SAC) Financing (3, 6,12,1$, 24 months) options will require an additional upfront fee. Standard (1-12) years financing is offered with no upfront fees. All financing is contingent upon credit approval. Standard Rome Improvement financing offered from 9.99% APR for A and A+ credit rating. Southeast Generat Contractors Group Inc. partners with EnerBank Improvement loans. Existing gutters will be, emoved or detached to allow for the installation of the new roof ng system. Sourtheast General Contractors Group, Inc. will attempt to save the gutters but in the event they are damaaged the Owner accepts full respansibiltty for said gutters. __% -1 00— fmit" ��Replace all bad decking Cshsided, dditip`nlsh� Premium 5135 Flashing Gernert billed at $80.00 each) � Install new metal 16' - 26ga set in Matrix s201 Premium SBS Re -nail deck as required by Hurri, gation Rear fit Manual Fla g Cement at sloop roof tie-in (Based on 553.844 ES.) ✓ / �•� l <�1 ' /5 C„ Cl 0-D Notes: f MND MITIGATION: • Southeast General Contractors Group, Inc. will provide a Wind Mitigation Report for an additional fee of NOT INCLUDED: ADDITIONAL ITEMS: Gutters Plywood:...................................................... Cost $80.00 per sheet labor and material Metal fascia trim Fascia: ........................................................... Cost $18.801/flabor and material Metal roof structures Second layer removal: ................................ Cost $28.00 per square Satellite dish removal or replacement Chimney flashing: ...................................... Cost $225.00 plus stucco if required at $37.50 per s/f Screens and screen enclosures Flashing, step, counter or base: ................. Cost $17.251/f labor and material Solar heater removal or replacement Gutter removal: ........................................... Cost $ .50 Skylights Rafter tail repairs: ....................................... Cost $120.00 each Truss repair Skylight replacement and flashing:.......... Cost $475.00 each Stucco repair ............................................... Cost $37.50 per square foot GENERAL TERMS AND CONDITIONS Change Orders, contractor may accept a `change order" to the plans, specifications or equipment. In addition, the total price increased or decreased to reflect the change, and the same shall be in writinand signed by the ()caner and Contractor. Any increase to the contract price shall be paid by the Owner upon ordering the work called for in such 'change order or upon execution of the change order as required by the contractor. Southeast General Contractors Group, Inc. is responsible for completion of work in compliance with contract documents and for quality of material and workmanship in accordance with standard specifications. Labor Warranty/5 ear on workmanship. Material Warranty 30 -year limited warranty. Same a Cash (SAC�i Financing (3, 6, 12,18, 24 months) options will re wire an additional upfront fee. Standard (1-12) yyears financin is offered with no upfront fees. All financin is contingent upon credit approval. Standard Home Improvement financing offered from 9.99°l� APR for Fi and A+ credit rating. Southeast Genera)gContractors Group Inc. partners with Enerliank Improvement loans. Existing gutters will be removed ar detached to allow for the installation of the new roofing system. Sourtiieast General Contractors Graup, Inc. will attempt to save the gutters but in the event they are damaaged the Owner accepts full responsibilEty foz said gutters. We hereby propose to furnish labor and materials complete in accordance with the above specifications, for the sum of: $ _, Schedule of Values: Deposit: Is due upon executing this contract. $ Draw #1: Is due when the roof is dried -in, before shingles are delivered. $ -�•% } �- Draw #2: is due upon the final inspection. $�{ All material is guaranteed to be as specified. All work to be completed in a workman like manner according to standard practices. Any alteration or deviation from above specifications involving extra cost, will be executed only upon written orders, and will become an extra charge over and above the estimate. All agreements are contingent upon strikes, accidents or delays beyond our control. This proposal subject to acceptance within 10 days and is void thereafter at the option of the undersigned. ACCEPTANCE OF PROPOSAL The above prices, specifications and conditions are hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. AUTHORIZED;R' ACCEPTED 0" f r Date/ Signature: X��i-—Date" So"uthejisf General Can actors Group, Inc. Signature: Date �EAGLEVIEW a LENGTH DIAGRAM Total Line Lengths: Ridges = 38 ft Hips = 118 ft Valleys = 17 ft Rakes = 28 ft Eaves = 221 ft Premium Report 7/12/2018 Flashing = 0 ft Step flashing = 11 ft Parapets = 0 ft N w Note: This diagram contains segment lengths rounded to the nearest whole number over 5.0 Feet. In some rases segment labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e,q. +6 and +9 p 2009-2018 Eagle View Technologies, Inc. and Plctomet y IrternatEunal Corp. — Alf R ghts Reserved — Protected by European Patent Application No, 10162199.3 — Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,890; 8,209,152; 8,515,125; 8,825,454; 9,135,737, 8,670,955; 9,514,568; 8,816,770; 8,542,884; 9,244,589; 9,329,749; 9,599,466. Other patents Pending. PAGE 4 EAG LEVIE'W`� Premium Report 7/i2/za1s PITCH DIAGRAM Pitch values are shown in inches per foot, and arrows indicate slope direction. The predominant pitch on this roof is 3/12 t m 3 3 -> 1 N E x�:W 5 Note: This diagram contains labeled pitches for facet areas lar er than 20.0 square feet. In some cases itch labels have been removed for readability. Blue shading indicates a pitch of 3/12 and greater. Gray shading indicates flat, 1/12 or 2/12 pitches. 2008-2018 Eagle View Technologies, [nc. and Plctome" International Corp. -- All Rights Reserved – Protected by European Patent Appkation No. 10162199.3 – Cc -red by one or more of U.S. Patent Nos. 8,678,436; 8,145,578; 6,170,840; 8,209,152; 8,515,125; 8,025,454; 9,135,737; 8,570,961; 5,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 5 1;� EAGLEVIEW 0 AREA DIAGRAM Total Area = 2,676 sq ft, with 7 facets. 319 346 563 540 544 225 Premium Report 7/12/2018 140 N E w 5 Note: This diagram shows the square feet of each roof facet (rounded to the nearest Foot) The total area in square feet at the too of this page, is based on the non -rounded values of each roof facet rounded to the nearest square foot after being totaled). V 2406-2018 Eagle View Technologies, Inc. and Pictnmetry International Corp., —All Rights Resmved — Protected by European Patent Application No. 19162199,3 — Covered by orre or more of 41.5. Patent Nos. 8,078,436; 8,145,576; 8,174,846; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,566; 8,818,77G; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents ;'ending. PAGE 6 N.: 4 Z a 00. o .J: pq C N V Q O O y i N N N 76 a CO k n E CD O � z [r) o a` J LL � C E 7 z N 0 '6 4D N a U � 6 Q1 La La w d L a o •� 0. c v � N c m a CL O ON G C O d Q R m CL 0 a 3 0 a 0 w — w rn u — _ L m ° a s LL LCI UJ fA {f} _ W C7 2 o 0 Q' � $16!2018 Florida Building Code Online Professional Regulation.. SCIS Home ! Lag In o User Registration fiat Topics Submit Surcharge ! Stats & Facts Publications HBc staff I Bas Site map I unks search b 3 $ product Approval r 4 USER: Pubitc User . I i W Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL17322-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Atlas Roofing Corporation Address/Phone/Email 2000 RiverEdge Parkway Suite 800 Atlanta, GA 30328 (770) 946-4571 mcol lins @atlasroofing, cam Authorized Signature Meldrin Collins mcollins@atlasroofing.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE -74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL17322 R4 COI ATL14001.4A 2017 FBC Eva[ Report Atlas Underlayments final.pljf Referenced Standard and Year (of Standard) Standard Year ASTM D 1970 2015 ASTM D 226 2009 ASTM D 2626 2004 ASTM D 4869 2016 ASTM D 6380 2003 TAS 403 1995 TAS 110 2060 UL 1897 2012 Equivalence of Product Standards https:lhvww.floridabuilding.org/pr/pr_app_dtl.aspx?p2ram=wGEVXQwtDgsRyNwiNWDrY8PHC4TwsBEc8KxLSaJJG7DPQikaGxFKuQ%3d%3d 1i 6/6/2618 Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Florida Building Code Online Method 1 Option D 09/30/2017 10/03/2017 10/04/2017 12/12/2017 l `FL # j Model, Number or Name 9 'Description l 17322.1 Atlas Underlayments j For use in steep slope roofing Limits of Use I i Installation Instructions ' Approved for use in HVHZ: Yes FL17322 R4 11 ATL14001.4A 2017 FBC Eval Report Atlas Approved for use outside HVHZ: Yes i EJnderlayments final.pdf j Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports j 1 FL17322 R4 AE ATL14001.4A 2017 FBC Eval Report Atlas Underlayments final.pdf ! Created by Independent Third Party: Yes i 17322.2 1 Fabral All Purpose High Temp j ASTM D 1970, SBS modified, self -adhering underlayment with i Underiayment fiberglass mat reinforcement and a poly -fabric surface. { Limits of Use Approved for use in HVHZ: YesI i Installation Instructions FL17322 R4 II ATL14001.4B 2017 FBC Eval Report Atlas Approved for use outside HVHZ: Yes 9 Fabral Underlay.D t finai.pdf Impact Resistant: N/A ! Verified By: Zachary R. Priest PE -74021 Design Pressure: WA Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports I FL17322 R4 AE ATL14001.4B 2017 FBC Evac Report Atias I Fabral }Underlayment f!nal.pdf Created by Independent Third Party: Yes i Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State or Florida is an AA/EED employer. Copyright 2407-2015 StIte, of Florida.:; Privacy Statement :: Accessibility. Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail, I€ you have any questions, please contact 85(1.487.1395. *Pursuant to section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. IF you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under chapter 455, r.S., please click here . Product Approval Accepts: Credit Card Sate https:llwww.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgsRyNwiNWOrY8PHC4TwsBEc8KxLSaJJG7DPQ[kaGxFKuQ°/a3d°/n3d 212 I ECHNICAL. SERVICES, LLC EVALUATION REPORT Manufacturer: ATLAS ROOFING CORPORATION 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 (770) 612-6267 w1Afvv.a tlasrooTina.com Quality Assurance: UL LLC (QUA9625) SCOPE Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813)480-3421 FLORIDA BUILDING CODE, 6" EDITION {201 Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1, 1518.4, 1523.1.1, 1523.6.5.2.1 Properties: Physical properties REFERENCES Issued September 30, 2017 Entity Report No. Standard Year PRI Construction Materials Technologies (TST6049) ATL -033-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) ATL -068-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL -068-02-01 ASTM D 4798 2011(2016) PRI Construction Materials Technologies (TST6049) ATL -068-02-01 TAS 110 2000 PRI Construction Materials Technologies (TST6049) ATL -069-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL -090-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) ATL -149-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL -164-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) BWR-533-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) SWR -543-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA -004-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA -007-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST6049) MSA -026-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) WRMI-011-02-01 ASTM 1970 2015a PRI Construction Materials Technologies (TST6049) MSA -007-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST6049) MSA -030-02-01 ASTM D 1970 2015a UL LLC (TST1740) 02-NK40952 ASTM D 1970 2015a UL LLC (TST1740) 02-NK40952 ASTM 0 226 2009 UL LLC (TST1740) 02-NK40952 ASTM D 2626 2004(2012)E1 UL LLC (TST1740) 02-NK40952 ASTM D 4869 2016 UL LLC (TST1740) 02-NK40952 ASTM D 6380 2003 (2013) ATL14001.4A FL17322-R4 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ATLAS ROOFING CORPORATION CREEKRoofing Underlayments TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION #15 Specification Felt ASTM D 226, Type I asphalt saturated organic felt underlayment for use in the HVHZ and non-HVHZ. #30 Organic Saturated Felt ASTM D 4869, Type II asphalt saturated organic felt underlayment for use in the non-HVHZ only. #30 Specification Felt ASTM D 226, Type Ii asphalt saturated organic felt underlayment for use in the HVHZ and non-HVHZ. #43 Base Sheet ASTM D 2626 asphalt saturated and coated, non -perforated, organic felt underlayment for use in the HVHZ and non-HVHZ. #90 Mineral Surface Roll ASTM D 6380, Class M asphalt -saturated organic roll roofing sheet for use in the Roofing HVHZ and non-HVHZ. Gorilla Guard® EVERFELT 30 Asphalt -saturated organic felt underlayment reinforced with glass fiber that meets the performance requirements of ASTM D 226, Type I for use in the HVHZ and non-HVHZ. Slate/Tile Underlayment ASTM D 6380, Class M asphalt -saturated organic roll roofing sheet for use in the HVHZ and non-HVHZ. WeatherMaster@) Ice and ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a Water 100 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation, WeatherMaster0 Ice )and ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a Water 200 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The �� self-adhesive side is covered with a split -release film, which is removed during installation. WeatherMaster@) Ice and ASTM D 1970 SSS modified, self -adhering underlayment reinforced with a Water 216 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split -release film, which is removed during installation. WeatherMaster@) Flexible Ice ASTM D 1970 SBS modified, self -adhering underlayment with plastic film surface and Water for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split -release film, which is removed during installation. WeatherMaster@ Pro -Grade ASTM D 1970 SBS modified, self -adhering underlayment with a fiberglass mat Ice and Water reinforcement and a poly -fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. WeatherMaster@ Tile TAS 103 SBS modified, self -adhering underlayment with a fiberglass mat reinforcement and a poly -fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. ATL14001.4A FL17322-R4 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ATLAS ROOFING CORPORATION CREEK Roofing underlayments TECHNICAL SERVICES, LLC APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. Exposure of the underlayments shall be limited to a maximum 30 days except as follows: a) #15 Specification Felt, #30 Specification Felt, and #40 Base Sheet — exposure for than 24 hours may adversely affect product performance b) WeatherMaster® Ice and Water 100, WeatherMasterQ Ice and Water 200, and WeatherMastere Ice and Water 216 — maximum 30 days c) WeatherMaster® Pro -Grade Ice and Water and WeatherMastera Flexible Ice and Water — maximum 30 days d) WeatherMaster® Tile — maximum 90 days Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as indicated in other current FBC product approval documents): a) WeatherMaster® Pro -Grade Ice and Water or WeatherMaster® Tile — ICP Adhesives Polyset AH -160 b) Slate/Tile Underlayment or #90 Mineral Surface Roll Roofing — Convenience Products Touch n' Seal StormBond Roof Tile Adhesive, pow TileBond, or ICP Adhesives Polyset AH -160 Allowable Roof Coverings: Underfa went Asphalt Shin les Metal Roof Panels and Shin les Composite or Wood Photovoltaic Shingles and Shingles shakes Slate Shingles Clay and Concrete Tile #15 Specification Felt Y Y Y Yz Y N #30 Organic Saturated Felt Y Y Y Y Y N #30 Specification Felt Y Y Y Y Y Y #43 Base Sheet Y Y Y N Y Y #90 Mineral surface Roll Roofing Y' N N N N Y Gorilla Guard9 EVERFELT 30 Y Y Y I Y2 Y N SlateMte Underlayment Y' N N N N Y WeatherMaster; Ice and Water 100 Y Y Y N Y N WeatherMasterOIce and Water 200 Y Y Y N Y N WeatherMaster@ Ice and Water 216 Y Y Y N Y N WeatherMaster® Flexible Ice and Water Y Y Y N Y N WeatherMaster® Pro -Grade ice and Water y Y Y N Y N WeatherMaster(DTiie Y Y Y N Y Y +Okes: !) ,i Pun vauey appucauons per _i nut.z.y.z 2) Wood shingles only ATL14001.4A FL17322-R4 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ATLAS ROOFING CORPORATION CREEK Roofing Underlayrnents TECHNICAL SERVICES. LLC WIND RESISTANCE (NON-HVHZ ONLY) The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underl_ayment System No.1 — WeatherMaster® Tile only Roof Deck: Min. 15132 -inch CDX plywood attached to wood supports spaced a maximum 24" o,c. Underlayment: WeatherMaster0 Tile shall be fully adhered to the optionally primed plywood deck. Maximum Design -52.5 psf Pressure: LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Roof slope limitations shall be in accordance with FBC requirements. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published. application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Products described within this report may be used as described in other current FBC product approval documents. 5) Roof coverings shall not be adhered directly to the underlayment unless otherwise approved in this or other current FBC product approval documents_ 5) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest P,E, have demonstrated compliance with the Florida Building Code, 6u' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. `'Iyf111111111 Ri F3 G�.. No 74021 • • Q: ti •• STATE OF :•w: O• Lv A, p:•: Itilrill CERTIFICATION OF INDEPENDENCE 2017.09.30 12:44:22 -04'00' Zachary R, Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT ATL14001.4A FL17322-R4 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 61612418 - - 5cIs Mame_ Log In User Registration Floc Topics Product Approval USER: Public user Florida Building Code Online i Submit Surrharge Stats & Facts Publications FSC Staff SCIS Site Map Links Search a ^,roc crgl L"r' 5_c > 5 Application Detail FL # FL16305-R6 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Atlas Roor€ng Corporation Address/Phone/Email 2000 RiverEdge Parkway ASTM D 3161 Suite 800 ASTM D 3462 Atlanta, GA 30328 ASTM D 7158 (770) 946-4571 TAS 100 mcallins@atlasroofing.com Authorized Signature Meldrin Collins mcollins@atlasroofing.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE -74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence ! .'r -== C01 `• �? 3 Ot' ,C; 7017 FEC Ft/a1 r r Referenced Standard and Year (of Standard) Standard Year ASTM D 3161 2016 ASTM D 3462 2010 ASTM D 7158 2011 TAS 100 1995 TAS 107 1955 Equivalence of Product Standards Certified By Sections from the Code �;�p-�. "%' •:Zv.:ioridahUilding.arglorlor_asp_dtl.aspx?param=wGEVXQWtDquJBMjgt31j3NITGP1D8aJCJnk%2bsJZMHcThLaVSdO �kh9es—=el,z.:G,- ... 616/2018 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FEC Approval Date Approved Summary of Products FIL Model, Dumber or Name 16305.1 T Atlas Shingles i_innits of Use -- Approved for use in HVHZ: yes Approved for use outside HVHZ: Yes impact Resistant: N/A Design Pressure: N/A Other; See evaluation report for limits of use Method 1 Option D 04/30/2017 10/03/2017 10/€74/2017 12/12/2017 Description Fiberglass reinforced laminated asphalt shingles Installation instructions F 16305 P,6 71 ATL13002 ' 2017 F6C Eval F 1p^ �RF� _�E5 lnal.p�r - -- Verified By: Zachary R. priest 74021 i Created by Independent Third Party: Yes Evaluation Reports F116305 i`'.5 AE ^,Ti 13aL2 j Created by Independent Third Party: yes Contact Us :: 2691c.lair Stone Road, Tallahassee FL 32399 Phone: 859-487-1824 The State of Florida is an AA/EEo employer. C:ggy ght 07-21313 State of Florida.:: Pr^i ,tract' Statement :: Accessibility tatement ;: Refund Statement Under norida Iain, email addresses are public records. If you do not went your a -mail address released in response to a puhfic-records request, do not send etactronit mail to this entity. Instead, contact the office by phone or by traditional main If you have any questions, please contact c-tecO ds req . Pursuant se Seetian 455,27_{i.7, Fiorida Statub--s, effective October 1, 2012, licenses licensed under Chapter 455, F.S. must provide the Department with an email address #f they have one. The emal€s provided may be used for official communication rjith the licensee. However email addresses are public record. If you do not wish to supply a personal address, pease provide the Department with an email address which can be nade available to the public. To determine if you are a Iitensee under Chapter 495, F.S., please click here . Product Approval Accepts: Credi Card Safe -� ,... ,.-.. �ahuildirg.orgtprlpr apP_dtl.aspx'?param=GvGEVXQwtDquJ�MjgiJlj3l'd1TGPi08aJC.lnlydl�n�I7�,�urT�lR„Q,,Q.��.rse:---.,,,,...,._. Cw'* R E E K TECHNICAL SERVICES, LLC EVALUATION REPORT Manufacturer: ATLAS ROOFING CORPORATION 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 (770) 612-6267 Manufacturing Plants: Hampton, GA Meridian, MS Dangerfield, TX Ardmore, OK Franklin, OH Quality Assurance. UL LLC (QUA9625) SCOPE Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 FLORIDA BUILDING CODE 6' EDITION (2017) Category: Roofing Subcategory: Asphalt Shingles Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties, Wind Resistance, Wind Driven Rain PRODUCT DESCRIPTION Issued September 30, 2047 Legend (Ardmore) ASTM D 3161, Class F fiberglass reinforced, 3 -tab asphalt shingle with a dashed, sealant stripe that complies with ASTM D 3462. thermally -activated, self-sealing GlassMaster® 30 ASTM D 3161, Class F fiberglass reinforced, 3 -tab asphalt shingle with a dashed, sealant stripe that complies with ASTM D 3462. (Ardmore & Hampton) thermally -activated, self-sealing Tough -Master® 20 ASTM D 3161, Class F fiberglass reinforced, 3 -tab asphalt shingle with a dashed, sealant stripe that complies with ASTM D 3462. (Ardmore & Hampton) thermally -activated, self-sealing Pro -Cuff® Hip & Ridge ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle with a sealant stripe that complies with ASTM D (Ardmore & Hampton) dashed, thermally -activated, self-sealing 3462. Pro -Guth Starter Strip ASTM D 3161, Class F fiberglass reinforced, starter asphalt shingle with a dashed, sealant stripe that complies with ASTM D 3462. (Hampton) thermally -activated, self-sealing ProLAMT111 Architectural ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated with a dashed, thermally -activated, self-sealing sealant (Hampton, Franklin & Meridian) architectural asphalt shingle stripe that complies with ASTM D 3462. Pinnacle@ Pristine, ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated two, dashed, thermally -activated, self-sealing sealant Pinnacle@ Pristine Lifetime w/Scotchgard architectural asphalt shingle with stripes that complies with ASTM D 3462. (Dangerfield, Hampton, Franklin & Meridian) StormMaster@ Shake ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated (Dangerfield) architectural modified asphalt shingle with two, dashed, thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. ATL13002.6 FL 16305-R6 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3_ The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, ar other product attributes that are not specifically addressed herein. ATLAS ROOFING CORPORATION CREEK Asphalt Shingles TECHNICAL SERVICES. LLC StormMaster@ Slate ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated (Ardmore) architectural modified asphalt shingle with two, dashed, thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. REFERENCES Entit Report No. Standard Year PRI Construction Materials Technologies (TST5878) ATL. -079-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL -083-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL -086-02-01 Rev 1 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATLA 04-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -106-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL -106-02-01 Rev 1 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL -107-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL -107-02-01.1 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL -109-02-01 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL -116-02-01 ASTM D 3462 201 DA PRI Construction Materials Technologies (TST5878) ATL -118-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -119-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL -123-02-01 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL -125-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL -127-02-01 Rev 1 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL -132-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATLA33-02-D1 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL -135-02-01 ASTM D 3462 2010A PRl Construction Materials Technologies (TST5878) ATL136-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -137-02-01 Rev 1 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL -138-02-01 Rev 1 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL -143-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL -144-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL -151-02-D1 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -162-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL -167-02-01 ASTM D 3161 2016 PRI Construction Materials Technologies (TST5878) ATL -168-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL -169-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -170-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -171-02-01 ASTM D 3462 201 DA PRI Construction Materials Technologies (TST5878) ATL -172-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -174-02-D1 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -179-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL -184-02-01 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL -185-02-01 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL -186-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL -1 87-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -220-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -220-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL -220-02-03 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL -220-02-04 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL -221-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -221-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL -221-02-03 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL -221-02-04 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL -222-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -222-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL -222-02-03 ASTM D 3161 2016 ATL13002.6 FL 16305-R6 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61(320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quaiity assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES. LLC ATLAS ROOFING CORPORATION Asphalt Shingles Entity Report No. Standard Year TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL -222-02-04 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL -223-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -223-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL -223-02-03 ASTM O 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL -223-02-04 ASTM D 7158 2011 PRI Construction Materials Technologies (TST5878) ATL -224-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -225-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL -225-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL -225-02-03 ASTM D 3161 2016 TAS 107 1995 PRI Construction Materials Technologies (TST5878) ATL -225-02-04 ASTM D 7158 2011 ATL13002.6 FL 16305-R6 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TEct INICAL SERVICES, LLL-- INSTALLATION Iwv INSTALLATION ATLAS ROOFING CORPORATION Asphalt Shingles Legend Basic Wind Speed (Vuit): Max. 194 mph Basic Wind Speed (V�sd): Max, 1541 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min, 19132 in. plywood or wood plank for new construction; Min. 15132 in. plywood existing construction. Deck (Non-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction; Min. 7116 in. OSB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed with 5 -inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5 -inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. Figure 1. Legend 4 Nail Pattern (Non-HVHZ only) Figure 2. Legend 6 Nail Pattern ATL13402.6 FL 16305-R6 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. SEK TECHNICAL SERVICES, I_L..0 GlassMaster@ 30 & Basic Wind Speed (V„Ic): Tough -Master@ 20 Basic Wind Speed (Vasd): Deck (HVHZ): Deck (Non-HVHZ) Underlayrnent: Min. slope: Installation (HVHZ): Installation (Nan-HVHZ): ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15132 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction; Min. 7116 in. OSB existing construction. In accordance with FBC requirements. 2.12 and in accordance with FBG requirements. Contact the Atlas Roofing CorporatEon when installing at slope greater than 21:12. Installed with 5 -inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5 -inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either `°4 Nail Pattern" or "6 Nail Pattern" detailed below. A ails N. l LJ* in * w A 12{ Figure 3. GlassMaster@ 30 & Tough -Master@ 20 4 Nail Pattern (Non-HVHZ only) Nail$ n ewe vertMap am "w 12"'12 ■ Fl -- -- 12"' 3 e� R+�w naive P ■ ■ •% �..J1r�l � n Figure 4. GlassMaster@ 30 & Tough -Master@ 20 6 Nail Pattern ATL13002.6 FL 16305-R6 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein_ CREEK TE,cHNICAL SERVICES, LLC Proli Architectural Basic Wind Speed (Vu,): Basic W ind Speed (Va.d): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19132 in. plywood or wood plank for new construction; Min. 15132 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction; Min. 7/16 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. installed with 6 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nall Pattern" detailed below. Installed with 6 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or `°6 Nail Pattern" detailed below. SINGLE Ya' SEALANT UNL PATTERN 1 LENGTH ©N: 1" OFF . ;..� 13II3' TV * — — — — — - - - ---- --- - -- - -3" } /yam — — - 5., W, NAIUNr AREA i 74 Figure 5. ProLAMTm Architectural Shingle 4 Nail Pattern (non-HVHZ only) FALAri1T --------- -- -- - - - --- --- - .._ _ .. . ---- -- ---- Figure 6, Pro-LAMTM Architectural Shingle 6 Nail Pattern ATI -13002.6 FL 16305-R6 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERV IcEs. LLC Pinnacle® Pristine & Basic Wind Speed (V,!t): StormMasterO Shake Basic Wind Speed (Va,d): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): T I t 6, ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19132 in. plywood or wood plank for new construction; Min. 15132 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction; Min. 7116 in. OSB existing construction, In accordance with FBC requirements. 2:12 and in accordance with FBC requirements_ Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installed with 6 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nall Pattern" detailed below. Installed with 6 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. U' BLE ; SEND:,, L%ti-•TFCW I- hNGI,' 1313' �i lYP i —{ _i-�—!_ l— — —Mik— --4mop— 4 %�" FFAf3MG R0. Figure 7. Pinnacle@ Pristine and StormMasterO Shake 4 Nail Pattern (Nan-HVHZ only) 1807 A: 1" LEND-�! ON: 1" OFF I .. �.-�. .. ~ i ............. _ _____... -- .. .. ___.__ _.... III - -- - !� A i !- - AND-- � � -_ - �- - �- --. _ Figure S. Pinnacle® Pristine and StormMaster® Shake 6 Nail Pattern ATL13002.6 FL 16305-R6 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 14" CREEK Tr=cHNICAL SERVICES. LLC StormMaster(D State Basic Wind Speed (Vuit): Basic Wind Speed (Vasd): Deck (HVHZ): Deck (Non-HVHZ) Underlayment: Min, slope.- Installation lope: Installation (HVHZ) Installation (Non-HVHZ): ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19132 in, plywood or woad plank for new construction; Min. 15/32 in_ plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction; Min. 7116 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12_ Installed with 8.5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 8.5 in, exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. Figure 9. StormMaster0 Slate 4 Bail Pattern Figure 10. StormMaster4 Slate 6 Nail Pattern ATL13002.6 FL 18305-R8 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL. SERVICES, LLC Pro -Cut® Starter Strip Basic Wind Speed (V,,Ii): Basic Wind Speed (Va,d): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ) Installation (Non-HVHZ): ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19132 in. plywood or wood plank for new construction;.. Min. 15132 in. plywood existing construction. In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction; Min. 7116 in. OSB existing construction. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installed in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached as shown below. Installed in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached as shown below. f2 ga.1-i/P'eMg sunk naazl Figure 11, Pro -Cut@ Starter Strip ATL13002.6 FL 163135-R6 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES. LLC Pro -Cu* Hip & Ridge Basic Wind Speed (V,,It): Max. 194 mph ATLAS ROOFING CORPORATION Asphalt Shingles Basic Wind Speed (Va,d): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19132 in. plywood or wood plank for new construction; Min. 15132 in_ plywood existing construction. Deck (Nan-HVHZ): In accordance with FBC requirements; Solidly sheathed min. 15132 in. plywood or wood plank for new construction; Min. 7/16 in. ©SB existing construction. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Installation (HVHZ and Installed with 5-5/8 inch exposure in accordance with RAS non-HVHZ): 115 (HVHZ only) and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. -- 12` --_—�T 12,7a. 1-1/2" ring r shank nail 1, L! I 7 S• r I I Figure 12. Pro -Cut® Flop & Ridge ATL13002.6 FL 16305-R6 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ATLAS ROOFING CORPORATION CREEKAsphalt Shingles TECHNICAL SERVICES. LLiC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM C 7158 applies to exposure B & C with a building mean roof height of 33 -ft or less. 5) heck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3, COMPLIANCE STATEMENT The products evaluated herein by Zachary R_ Priest, P.E. have demonstrated compliance with the Florida Building Code, 61' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. E N C��i 2 01 / .0 J . J No 74021 � � 0 12:37:24 2.3/ .24 -04' 001 ©'.. STATE OF ;' Z 'ot��`'� ©R 14 P'C, ��R. Zachary R. Priest, P.E. s&/� * AL �\-' 0 Florida Registration No. 74021 �jjrrrr11111 � Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have: nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT ATL13002.6 FL 16305-R6 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid, This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.