Loading...
HomeMy WebLinkAboutWind Load Calculation y RECEIVED j,% PJULIE ! I '1018 sr. �-�de bounty, Permitting f Property Information Building Information Owner: Harris Wind Zone: 150 MPH. Address: 7716 Wexford Way Exposure Category: B Port St Lucie,Fl 34986 Minimum Building Dimension: 24 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive IF Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 End 48 66 7 27.1 -35.3 2 Int 96 66 7 25.8 -28.2 3 Int 48 66 7 27.1 -29.5 4 End 48 66 7 27.1 -35.3 5 End 39 86 7 27.0 -35.1 6 End 48 62 7 27.2 -35.5 7 Int 37 86 7 27.1 -29.5 8 Int 27 46 7 28.5 -31.0 9 Irit 132 46 7 25.9 -28.3 10 Int 27 84 7 27.6 -30.1 11 Int 224 84 7 23.8 -26.2 12 End 48 . 62 7 27.2 -35.5 13 Int 48 62 7 27.2 -29.6 14 Int 26 62 7 28.3 -30.8 15 Int 26 62 7 28.3 -30.8 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.61h Edition(2017)Florida Building Code. Page 1 of 1