HomeMy WebLinkAboutWind Load Calculation y
RECEIVED
j,% PJULIE !
I '1018
sr. �-�de
bounty, Permitting f
Property Information Building Information
Owner: Harris Wind Zone: 150 MPH.
Address: 7716 Wexford Way Exposure Category: B
Port St Lucie,Fl 34986 Minimum Building Dimension: 24 ft.
Mean Roof Height: 15 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive IF Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 End 48 66 7 27.1 -35.3
2 Int 96 66 7 25.8 -28.2
3 Int 48 66 7 27.1 -29.5
4 End 48 66 7 27.1 -35.3
5 End 39 86 7 27.0 -35.1
6 End 48 62 7 27.2 -35.5
7 Int 37 86 7 27.1 -29.5
8 Int 27 46 7 28.5 -31.0
9 Irit 132 46 7 25.9 -28.3
10 Int 27 84 7 27.6 -30.1
11 Int 224 84 7 23.8 -26.2
12 End 48 . 62 7 27.2 -35.5
13 Int 48 62 7 27.2 -29.6
14 Int 26 62 7 28.3 -30.8
15 Int 26 62 7 28.3 -30.8
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.61h Edition(2017)Florida Building Code.
Page 1 of 1