Loading...
HomeMy WebLinkAboutProduct Approval (2) FLORIDA DEPARTIMT OF Regulati.9n , SCIS Home Log In I User Registration Hot Topics j SubmitSurcharge Stats&Facts Publications j FBC Staff i BCIS Site Map ' Unks Search ba ����.�� il Product Approval >e USER:Public User N"t . r Y Product Approval Menu>Product or Anolication Search>Application Lis[>Application.Detail FL# FL14605-R7- " Application Type Revision—, Code Version 2017 Application Status Validated Comments Archived Product Manufacturer Eastern Architectural Systems_ Address/Phone/Email 16341 Domestic Ave. R.Myers,FL 33912' (800)432-2204 Ext 4305 jflesher@eastemmetal.com RECEIVED Authorized Signature James Flesher jflesher@eastemmetal.com J U L 12 ?0 Technical Representative ST. Lucie County, PcrrnitCing Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category (Exterior_Doors —� Subcategory Sliding Exterior DoorA;seFnblies- Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2005 ANSI/AAMA/NWWDA 101/I.S.2 1997 ASTM E1886 2002 ASTM E1886 2005 ASTM E1996 2005 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL14605 R7 Equiv FL14605 9 10 it and 15-EO odf Product Approval Method Method 1 Option A Date Submitted 01/09/2018 Date Validated 01/10/2018 Summary of Products FL# Model,Number or Name Description 14605.1 Series 600 Non-Impact Aluminum Series 600 Non-Impact Aluminum SGD SGD Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL14605 R7 C CAC NI006120 01-R2-signed odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 12/31/2020 Design Pressure:+60.0/-60.0 Installation Instructions Other:Maximum 3 Panel,Multi-Track,Bypass FL14605 R7 II 08-02675.gdf Verified By: Luis R. Lomas,P.E.62514 Created by Independent Third Party:Yes Evaluation Reports FL14605 R7 AE 513450.odf Created by Independent Third Party:Yes 14605.2 Series 600 Non-Impact Aluminum Series 600 Non-Impact Aluminum SGD SGD Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL14605 R7 C CAC NI006119 01-R2-signed pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 12/31/2020 Design Pressure:+80.0/-80.0 Installation Instructions Other:Maximum 4 Panel,Multi-Track,Bypass FL14605 R7 II 08-02691.odf Verified By: Luis R.Lomas,P.E.62514 Created by Independent Third Party:Yes Evaluation Reports FL14605 R7 AE 513466.Ddf Created by Independent Third Party:Yes 14605.3 Series 623 Impact Vinyl SGD Series 623 Impact Vinyl SGD Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL14605 R7 C CAC NI011134-Rl.gdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 05/31/2021 Design Pressure:+50.0/-50.0 Installation Instructions Other:Maximum Size: 144"x 96"3 Panel Bypass,2-Track. FL14605 R7 II 08-01671A.Ddf FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK Verified By: Luis R.Lomas,P.E.62514 NORTH AMERICA AAMA CERTIFIED(DEP-1) Created by Independent Third Party:Yes Evaluation Reports FL14605 R7 AE 512351A.pdf Created by Independent Third Party:Yes 14605.4 Series 623 Impact Vinyl SGD Series 623 Impact Vinyl SGD Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL14605 R7 C CAC NI011134 01-R3 odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 05/31/2021 Design Pressure:+50.0/-50.0 Installation Instructions Other:Maximum Size: 192"x 96"4 Panel Bypass, FL14605 R7 II 08-01670A.gdf 2-Track.FRAME MATERIAL TO BE RIGID PVC FROM Verified By: Luis R.lomas,P.E.62514 DECEUNINCK NORTH AMERICA AAMA CERTIFIED(DEP-1) Created by Independent Third Party:Yes Evaluation Reports FL14605 R7 AE 512350A odf Created by Independent Third Party:Yes 14605.5 Series 623 Non-Impact Vinyl SGD Series 623 Non-Impact Vinyl SGD Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL14605 R7 C CAC NI011134 02-Ri odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 04/30/2021 ( � Design Pressure:+50.0/-50.0 Installation Instructions \ Other:Maximum Size: 144"x 96"3 Panel Bypass,2-Track. FL14605 R7 II 08-01673A pdf (`\ FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK Verified By: Luis R.Lomas,P.E.62514 v NORTH AMERICA AAMA CERTIFIED(DEP-1) Created by Independent Third Party:Yes Evaluation Reports FL14605 R7 AE 512353A odf Created by Independent Third Party:Yes REVISIONS REv DESCRIPTION OaTE APPROVED A I REVISED INSTALLATION DETAILS 06/22/15 R.L. NO1L5: 14. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN REOUIREMENTS OF THE FLORIDA BUILDING CODE SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE 9 CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. RESPONSIBILITY OF IHE ARCHITECT OR ENGINEER OF RECORD. r MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE I (OR GREATER). 3. IX BUCK OVER MASONRY/CONCRETE IS OPTIONAL. WHERE 1X BUCK IS NOT USED D. METAL STRUCTURE: STLF: 18GA, 33KSI OR ALUMINUM 6063-T5 1/8" THICK MINIMUM DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANF 15. APPROVED CONFIGURATIONS: OX, X0, 0X0 SELECTION OF COATING OR MEMBRANE IS IHE RESPONSIBILITY OF IHE ARCHITECT OR ENGINEER OF RECORD. 4. ALLOWABLE STRESS INCREASE OF 1/.3 WAS NOT USED IN IHE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. _. FRAME MATERIAL- EXTRUDED R;GID PVC_. 6 UNITS MUST BE GLAZED PER ASTM F.1300-04, WITH SAFETY GLAZING. APPROVED IMPACT PROTECT•IVL SVSTFM IS i2E UIIZCI) FOR THIS PRODUCT IN 'WIND BORNE DLBRIS REGIONS. 8. SHIM AS RCOUIRED AT EACH INSIA!..ATION ANCHOR WITH LOA*;'.I BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. FOR NAILING FIN INSTALLATION INTO WOOD FRAMING OR 2X. BUCK USE #8 WOOD SCREWS OR EOUIVALE:NT WITH SUFFICIENT LEN(.%, TO ACHIEVE A 1 I/2" MINIMUM EMBEDMENT INTO SUBSTRATE LOCATE ANCHORS AS _.•1OWN IN ELEVATIONS ANI.' -NSIALLATION DETAILS. 10. I-OR FRAME !NSIALLATION INTO WOOL: FRAMING OR 2X BUCK .:SL #12 WOOD SCREWS OR EOUIVALENT WITH SUFFICIENT LENGTH TO ACHIEVE A 1 5/8'* MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 1! FOR FRAME INSTALLATION INTO MASONRY/CONCRETE USE 1/4" TAPCONS OR EQUIVALENT WiTH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. M •12. FOR FRAME INSTALLATION INTO METAL STRUCTURE USE /J12 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE y INFERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 13. ALL FASTENERS TO BE CORROSION RESISTANT. SIGNED:06/23/2015 Ol Eastern S EASTERNARC"RECTURA STSfEuS W ER4 wES­5 \\ R �R. .4%7TABLE OF CONTENTS .-._._^._."^'.••_"^"^^"^ rem+v-mR:.noRmanv `��.�.�ENS, qtP i HLET NO. DESCRIPTION SERIES 623 VINYL SLIDING GLASS DOOR _*• 0 X51 nt 144" z 96" NON-IMPACT - -- —NOTES NOTES 7 NAIL FIN :;fVATION �O.• TAT -Cif --- REV �i'c •R P •C�Z S F!ANGE L1 T VAI R.L. 08-01673 A /i SS•••-•�G�� r...4. 6 INSTALLAI"JIN DETAILS SCALE NTS DATE 07/13/12 SHEET I OF 6 ///////111 1 REVISIONS REV DESCRIPlION WE APPROVED A REVISED INSTALLATION DETAILS 06/22/15 I R.L. 144' MAX FRAME WIDTH — 6" MAX — �•—f- 8 1/2" MAX O.0 —I — 6" MAX - - 6•' MAX I i i � I 96' 93 1/4" �I 14" MAX CL MAX MAX FRAME PAANEL HEIGTH FIE,GTH I I I j I 6" MAX '- -'---- �_ 48 1/2•• MAX - '-- --'- 1 PANEL WIDTH I SERIES 623 VINYL SGD EXTERIOR VIEW FLANGE INSTALLATION DESIGN PRESSURE RATING IMPACT RATING t50PSF NONE SIGNED:06/23/2015 �S'EEASreHmm+s \\111111!! 1Eastern RNDINM �EI�=P�. \5 R• L�/ ■ O�.�oC"�an:��..Y.'��� FORTWEPSi[lOa0at 2 ` SERIES 623 VINYL SLIDING GLASS DOOR =1r• 0, 51 *� 144Ex 96• NON—IMPACT �� ( w: FLANGE ELEVATION ��0, TAT OF DRaWN On NO REV 1,.-;S jOl0R1VP saLr NTS Darr 07/13/12 08 s0'Ec6330F 6 A /��//Sij0NAt1E?���� 2 1/2" MIN REISIONS EDGE DISTANCE REV DESCRtPION DATE APRRDVCD CONCRETE/MASONRYA REVISED INSTALLATION DETAILS 06/22/15 R.L. BY OTHERS a G• ° ° ° 1 1/4" MIN. OPTIONAL. IX BUCK ° 4 n EMBEDMENT 1 1j4" MIN. TO BE PROPERLY SECURED ' EMBEDMENT SEE NOTE 3 SHEET 1 E -' -- CONCRETE/MASONRY BY OTHERS —� APPROVED E -—f°ti�� o t 4" MAX SEALANT ^--, f , - OPTIONAL 1X BUCK -� ° SHIM SPACE" I I SHIM SPACE TO BE PROPERLY ° �. LLII SECURED SEE NOTE 3 SHEET T -- 1/Z- TAPCON � D j_CJJ- � 1/4" TAPCON i o INTERIOR C-�-� U U 2 MIN. pit I .� — r --- EDGE {I �••—T` EXTERIOR INTERIOR DISTANCE EXTERIOR i fes^ APPROVED SEALANT JAMB INSTALLATION DETAIL 1/4" 1APCON © � CONCRETEIMASONRY/NSTAtLA7tQN APPROVED O 0 _ SEALANT �� B 1 NOTES: 1/4- MAX. 1. INTERIOR AND EXTERIQR FINISHES.BY OTHERS. OPTIONAL IX BUCK o o r O SHIM SPACE NOT SHOWN FOR CLARITY. TO BE PROPERLY 2. PERIMETER AND JOINT SEALANT BYOTHERS 7O8E SECURED -- - - DESIGNED IN ACCORDANCE WITH ASTM E2112 SEE NOTE 3 SHEET 1 CONCRETE/MASONRY SIGNED:06/23/2015 ° BY OTHERS ° !° ° c • G 4. 1 1/4 MIN' EA6TEnNARC.RCTI- 11111"S EMBEDMENT �� Eastern E�:ERw 0u0s•�. \`�� IRIILD7ffJ` ° " ° ■ J ESIICAVE \ .6-00M 0RT MVERS,rLORiOA "z \`4•``G G N S• giPri 7j2" MIN. SERIES 623 VINYL SLIDING GLASS DOOR _=*• 0 51 [UGE DISTANCE 144 " x 96" NON-IMPACT =��G i INSTALLATION DETAILS TAT OF VERTICAL CROSS SECTION DRAWN. DWG NO R(V iO'�`••�CO�IOP••\ �\\ CONCRETE/MASONRY INSTALLATION r,C�s•.,• G RAL E 08-016 NTS 07/13/12 5 OF 6 REVISIONS APFROVID1 112" MIN. REV DESCR,PI.ON APPROVED SEMBEDMENT W D ILLATION DETAILS BEHIND FIN FRAMING 06/;,T/, R.L. 5 #8 WOOD BY OTHERS SCREW 1/4- MAX. SHIM SPACE 7/16" MIN j EDGE DISTANCE ' a D 1/4" MAX WOOD FRAMING HIM SPACE BY OTHERS #8 WOOD SCREW INTERIOR 1 112" MIN Ll INTERIOR CMBCDMI:N! !EXTER.10lj ED APPROVED SEALANT l .?-JPNO FIN o 7/16" m EDGE bl*,!A;%',: E EXTERIOR JAMB INSTALLATION DETAIL 0 J WOOD FRAMING OR 2X SUCK INSTALLATION vRii. 0 -LO1/4" MAX NOTES: SHIM SPACE Y. INTERIOR AND EXTERIOR FINISHES,BY OTHERS. NOT SHOWN FOR CLARITY, 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 7/16" MIN EDGE DISTANCE #8 WOOD WOOD SIGNED:0612312015 SCREW FRAMING--- f 1"TIR" 1-IM-III4i 1 1/2- MIN. BY OTHERS ........ EMBEDMENT APPROVED Eastern 1R. t SEALAT BEH ND FINN VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION SERIES 623 VINYL SLIDING GLASS DOOR 144" x 96- NON-IMPACT INSTALLATION DETAILS 10 M.- TAT OF DRAWN: DWG NO REV 0 R kDV' RALE.L. S,_, 673 "A NAL NTS 10"1 07/13/12 ICE16 OF 6 IIIIIN