Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 7,7 e it SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS'Site hlap i vUnks i Search i �, �1Fivi1G�3 r lr * l Product Approval USER:Public User Product Aoyroval enu>Produc[_or Appllcatlon Search>Application List>Application Detail FL# FL2569-1114 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Soprema,Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville,NON-US 00000 (819)478-2400 memath ieu@soprema.ca Authorized Signature Marc-Etienne Mathieu memath ieu@soprema.ca Technical Representative Marc-Etienne Mathieu Address/Phone/Email 1688 Jean-Berchmans-Michaud Drummondville, NON-US 00000 (819)478-2400 Ext 3327 memath ieu@soprema.ca Quality Assurance Representative Jean-Francois Cote, Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888)811-3145 jfcote@soprema.ca Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer -' Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J. M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/18/2020 Validated By John W. Knezevich,PE 'J Validation Checklist-Hardcopy Received Certificate of Independence FL2569 R14 COI 2018 01 COI NIEMINEN.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D4798 2011 ASTM D6163 2008 FM 4474 2011 FRSA/TRI April 2012(04-12) 2012 UL 1897 2012 http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwwdJgsKQFEnckB 10... 4/20/2018 Florida Building Code Online Page 2 of 2 6 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/12/2018 Date Validated 02/14/2018 Date Pending FBC Approval 02/17/2018 Date Approved 04/10/2018 Summary of Products FL# Model,Number or _ Description Name 2569.1 Soprema Roof Self adhering roof underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ:No FL2569 R14 II 2018 02 FINAL ER SOPREM_A CA UNDERLAYMENTS FL2569- Approved for use outside HVHZ:Yes 1114.pdf Impact Resistant:N/A Verified By: Robert Nieminen,P.E. PE-59166 Design Pressure: +N/A/-150 Created by Independent Third Party:Yes Other:1.)Refer to ER Section 5 for Evaluation Reports Limits of Use.2.)The design pressure FL256_._9_g14 AE 2018 02 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569- noted herein pertains to underlayment R14.,pdf systems used beneath adhesive-set tile Created by Independent Third Party:Yes systems. Refer to ER Section 5.6.4 for details. Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,j contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provid',e the Department with an email address which can be made available to the public.To determine If you are a licensee under Cliapter 455,F.S.,please click here. Product Approval Accepts: o Credit Card Safe i I http://www.floridabuildinc,.ora/pr/pr_app_dtl.aspx?param=wGEVXQwwtDgsKQFEnckB 10... 4/20/2018 Certificate of Authorization H32455 353 Christian Street, Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST P CONSULT - CERTIFY - Soprema, Inc. Evaluation Report S18010.06.09-1112 1640 rue Haggerty FL2569-R14 Drummondville,QuebecJ2C 5P8 Canada Date of Issuance:06/15/2009 (819)478-2400 Revision 12:02/12/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality Assurance or the production facility location(s). NEMOJetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words `rNEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user-by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M.Nieminen P.E. "��:� ~' ' ° The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 ocS' —" ` Nieminen,P.E.on 02/12/2015. This does not serve as an 9 ��• _`•" electronically signed document CERTIFICATION OF INDEPENDENCE: 1. NEW ETC,LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOletc. nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically forthat purpose. 4 a Nv_ISo@9„� i1Ta ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section PropeStandard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.4/1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008 TAS 110 Accelerated Weathering ASTM D4798 2011 7 7- Enti Examination Reference Date ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004 ERD(TST6049) Physical Properties 2757.02.05 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005 ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) Wind Resistance 2779.11.05-R1 04/18/2007 ERD(TST6049) TAS 103/TAS 110 S7120.11.07-2 11/02/2007• ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-R1 04/01/2010 ERD(TST6049) ASTM D1970/TAS 110 S31370.03.10-1-R1 04/07/2010 ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1 09/09/2010 ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.09-R2 10/05/2010 ERD(TST6049) ASTM D1970 537210.11.11 11/09/2011 ERD(TST6049) ASTM D1970 S40540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015 ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017 M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015 ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017 PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL,LLC(QUA9625) Quality Control Service Confirmation Exp.07/18/2020 4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12). 4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch;meets ASTM D1970. 4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment;available in 3.3 ft x 65 ft rolls;meets ASTM D1970. 4.4 Lastobond Shield HT is a self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof underlayment;meets ASTM D1970. NEM0 ETC,LLC Evaluation Report 518010.06.09-R12 Certificate of Authorization#32455 6"EDITION(2017)EBC N0N-HV9Z cVALUAT`I0N FL2569-R14 Soprema Roof Underlayments Revision 12,.02/12/2018 Page 2 of 8 4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch;meets ASTM D1970. 4.6 Lastobond Pro HT-S is a self-adhering,woven polyethylene surfaced, high temperature,SBS modified bitumen roof underlayment;meets ASTM D1970. 4.7 EnviroShield is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment;meets ASTM D1970. g 4.8 Lastobond 195 is a self-adhering, lass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.9 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.10 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.11 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.12 RESISTO LB1236 is a self-adhering,glass-mat reinforced,sand-surfaced, SBS modified bitumen roof underlayment, with a 36-inch sheet width;meets ASTM D1970. 4.13 PrimeSource Grip-Rite Eave & Valley Protector is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970. 4.14 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment, with a 44-inch sheet width; meets ASTM D1970. 4.15 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12). i�a �{UC ,E' .� _.- • �_...�_._.�v - ___.�_-._.�".-__.__--�--- �_� -__._�w_..... � .tet__-__� ..�:�-.._,: 5.1 , This is•a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way,the Designer x of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: -zee ] �....r �.•v 8 �� N 2lst(-4 _t ��4{ Aa' tx.,+' .w.* Wood or' Slate or -O Foam-On Composite Nail-On Asphalt P hA P Underlayment Shingles Tile Tile Meta! Shakes& Co late e Shingles Slate Yes Lastobond TU HT Yes Yes Yes Yes Yes See 5.5.1 Lastobond Shield/Pro HT-N/ RESISTO SA SMOOTH PLY 40 Yes No .No No.: Yes Yes 77 Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes . EnviroShield Yes - No ` No . :Yes _ Yes Yes NEMO ETC,LLL Evaluation Report 518010.06.09-1112 Certificate of Authorization#32455 6"EDITION(2017)FBC NON-HVH%EVALUATION FL2559-R14 Soprema Roof Underlayments Revision 12:02/12/2018 Page 3 of 8 r Wood or Slate or Asphalt Nail-On Foam-On Metal Composite Composite Underlayment. Shingles Tile Tile Shakes& Slate Shingles Lastobond Eaves Protection Sheet/ Lastobond 195 Yes No No No Yes Yes . Lastobond ECO /RESISTO LB1236, Grip-Rite Eave&Valley Protector/ Yes -No No',' No -Yes Yes RESISTO LB1244 Lastobond Smooth Seal HT Yes. No -No Yes.=, Yes Yes Colphene FR GR Yes Yes Yes No Yes Yes See�5.5.1 5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations. #I'ri-3V�SaSYi?�r�k 19'nt1 'jiil�fioaf ;S�Lfit'-p.�.=F°T��tey' S� Adhesive Florida Product Approval Underlayments DowTileBond' FL22525 Lastobond TU HT ICP Adhesives Polysetg AH-160 FL6332 Lastobond TU HT or Colphene FR GR 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to: ➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. Colphene FR GR applied to: > Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete. N ote: • > While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. ➢ .Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. 5.6.2 Bond-to-Insulation: Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tiles stems (Lastobond TU HT only), insulation attachment shall be designed by a qualified designn professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D, Testing Application Standard TAS 114,Appendix J or UL1807. t Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. MEMO ET{LLC Evaluation Report 518010.06.09-1112 Certificate oJAuthoriaation#32455 6�O EDITION(2017)F13C NON-HVHZ EVALUATION FL2569-RI4 Soprema Roof Underlayments Revision 12-.02/12/2018 Page 4 of 8 5.6.3 Bond to Mechanically Attached Base Layer: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield-HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified,requirements. For installations under foam-on tile systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2012(04-12). 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012(04-12)does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure=-45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. #2 Maximum Design Pressure=-67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. #3 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional)RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self-adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end- laps. #4 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c. in three (3),equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered 5.6.4.1 All other direct-deck, adhered Soprema underlayment systems beneath foam-on the systems carry a Maximum Design Pressure of-45 psf. NUAO FTC,LLC Evaluation Report 518010.06.09-R12 Certificate of Authorization#32455 6"ED!TION(2017)FBC M01N-HVHZ EVALUATION FUS69-R14 Soprema Roof Underlayments Revision 12:02/12/2018 Page 5 of 8 'l N ENIO etC. 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,RESISTO LB1236, exposed Grip-Rite Eave &. Valley Protector or RESISTO L61244 shall not be left e xp for longer g than 30-days after installation. Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT or Lastobond Pro HT- S,EnviroShield shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)): When loading roof tiles on the underlayment in direct-deck tile assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. �Jlat Underlayment Tile Profile Staging Method Maximum Slope Flat Max.10 the stack 6:12 Lugged Max.10-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack shall be inverted,followed by 8 tiles high 6:12 on slope,as shown below). Lastobond TU HT Lugged ,. - >4, Flat Max.10-tile stack 5.12 Colphene FR 6R Lugged Max.10-tile stack 6:12 MEMO ETC,LCC Evaluation Report 518010.06.09-1112 Certificate of Authorization#32455 6"EDITION(2017)FEC M0%1-HVH?EVALUATIOfsI r-L2559-1114 Soprema Roof Underlayments Revision 12:02/12/2018 Page6of9 a ,. � i,: �. i N EN". b s '7777— 777777 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER (if applicable). 6.3 Lastobond TU HT, Lastobond Shield; Lastobond Pro HT-fit, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,EnviroShield,Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT,RESISTO 1-131236,Grip-Rite.Eave&Valley Protector,RESISTO LB1244 or Colphene FR GR: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile Applications.- While pplications:While priming is optional,Soprema recommends priming with Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes above 8:12, Soprema recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place,working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein,and Soprema published requirements for tile staging. its 4.. t � arc_ - �" 'vka ''�" As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. NEMO ETC,LLC Evaluation Report 518010.06.09-1112 Certificate of Authorization#32455 6'EDITION(2017)FBC N0N-HVHZ EVALUATION FL2559-1114 Soprema Roof Underlayments Revision 12:02/12/2018 Page 7 of 8 �y jE oje c- Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. Plant Specification Prciduct(s)- . Lastobond Shield,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Drummondville, Lastobond Pro HT-N,Lastobond Pro HT-S,EnviroShield,Lastobond 195, ASTM D1970 Lastobond Eaves Protection Sheet,Lastobond Eco,Lastobond Smooth QC(Canada) Seal HT,RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley Protector,RESISTO LB1244 ASTM D1970&FRSA/TRI 04-12 Colphene FR GR Wadsworth,OH Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco, ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley Protector,RESISTO LB 1244 ASTM D1970&FRSA/TRI 04-12 Lastobond TU HT;Colphene FR GR Gulfport,MS Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco, ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley Protector,RESISTO LB1244 ,i. ,; ...........r '^'T.-'^.sv�h ^.- nS-, •r.du. .w _..�_.v-.M...rx.-cv....3�.rw.ti..+..a...x..su.u.-+ .w. �+n�....w-.-...�.-...F..—Sd....r:e� UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- MEMO ETC,LLC Evaluation Report 518010.06.09-1132 Certificate of Authorization 1132455 6"EDITION(2017)FEC NON-HVHZ EVALUAT30N FL2569-R14 Soprema Roof Underlayments Revision 12:02112/2018 Page 8 of 8 Florida Building Code Online Page 1 of 2 } w i BCIS Home i Log In i User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff i BCIS Site Map Links i Search 5��siLid 1 product Approval S f USER:Public User Product Approval Menu>Product or Apylicatio_n Search>Application List>Application Detail FL FL10674-1113 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manutacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com. Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email I Owens Corning PKWY Toledo, OH 43659 (419)376=8360 mel.sancrant@owenscomig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect of-a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W. Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R13 COI 201701 COI Nieminen.Ddf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections trom the Code http://www.flori dabui l ding.org/pr/pi_app_dtl.aspx?param=-,,vGEVXQwtDgtBNbEY5 VD/o2... 1/15/2018 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 10/10/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 10674.1_ Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R13 II- 2017 10 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674-R13.pdf Impact Resistant:N/A Verified By: Robert]. M. Nieminen PE-,59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER,Section S. Evaluation Reports - FL10674 R13 AE 2017 10-FINAL ER OC ASPHALT SHINGLES FL10674-R13.Ddf Created by Independent Third Party: Yes Back N Contact Us::2601 Biair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund-Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,-do not send . electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`Pursuant to , Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not knish to, supply a personal address,please provide the Department with an email address which can be made available to the public.To,determine if you are a licensee under Chapter 455,FS.,please click here. Product Approval Accepts: Gred::Cara Safe http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%2... 1/15/2018 j=" J,--, �� SEARCH&DESIGN LLC. - EXTERIOR RE , Certificate ofAuthorization#9503 ;E 353 CHRISTIAN OXFORD,�CT 06478 (203)262-9245 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-118 One Owens Corning Parkway FL10674-1113 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404=7829 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: -- �4� .. F Robert J.M.Nieminen,P.E. ;'!. The facsimile seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 , '����i i Nieminen,P.E.on 10/09/2017. This does notserve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. { ER ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Rooting Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section PropertV Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Kutilf Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: m s 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. a 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire"'are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration}, TruDefinition Duration, Duration' Premium Cool, TruDefinition' Duration' Designer C616e Collection, TruDefi n ition'Oak ridge', Oakridge and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip&Ridge Shingles: 4.2.1 Berkshire' Hip &Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgeT"'Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4:3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZjurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate of Authorization 09503 6 t EDITION(2017)PBC NON-FIVHZ EVALUATION! FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 1 '( I III ..�.,.. -_ .. � � i RINI g Ep� 5.4 Wind Classification: 5,4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D71S8, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasil = 150 mph (Vnit = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip Zit ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasa=150 mph (Vnit=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: a i% Berkshire shingles require minimum five(5)nails per shingle. i WeatherGuard'HP shingles require minimum six(6)nails per shingle. i Devonshire"shingles require minimum six(6)nails per shingle. Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Felt underfayrnent - Deck Felt underlaymeni -- Deck Seir-adhered Self•3dhered - underlay ne d Weatherl-ock' =r hail_.,f r:nderlayrnehti '�-,�_:r Drip edge Drip - Drip edge Drip— edge \' '' __Aapslocated A —"lads located j 2'-3'from eeva 2'-3"from cave Install first Self-sealing adhesive SEF-eding adhasive Starter Strip �.•-'�J osiiioned alor. cave Instal Post Starter Strip FLrs •r positioned along eave ✓ P 9 with 6°removed--- shingle sitlh '�.•. � ••,••'�� G°removed �..,�,„ Starter Su Flus overhangs eaves and rakes 1141-3/4" Starter Strip shingle overhangs eaves and rakes r-:r �' g Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R8 Certificate ofAuthorizatfon#9503 6"h EDITION(2017)FBC NON-HVHZ EVALUATION - FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 I I c E 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Area para Normal Mansard or Area para Wind Areas High Wind desvones y Wind Areas High Wind desvones y Area para vientos normales Areas viontos fuartes Area para vientos normales Areas vientos fuartes �i" 2-j {BI rz- t"� t° (A)-- tr tt I I:t212, i tet I' 5"Exposure 65/8"Exposure Exposition Enposicidn 6.2.7 Minimum Nailing—Berkshire®: Sealant strip sealant strip /La tira de sd;ador /La tea de sellador ��o,f-ibr • t-� a t�o • o +! e 0-6-0 1. 8 yt 9 Ort' 9 V1' sty. 6 1,Y1 t 1.. 1.. 1„J 1" e 0 Standard Fastening Pattern 6-Nail Fastening Pattern Sealant strip La tks desdla(br e.*--------->04--)+0 a o 4---------110 1" A 1 " 1 2" Asphalt roofingamtent Nmento rte teaho do astalto Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940-02-12-RS Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 b r-R 6.2.8 Minimum Nailing—DevonshireT"': �1� I 711 1 811 I 811 1. 811 I T i• Phils 1 Llayas ...... ' - Nails - IT" ` III 5.5/8"exposure Exposici6n de 5-5/8 pulg Sealant location Ubicacilin del sellador. j Ten 1"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition° Duration, Duration® Premium Cool & TruDefinition. Duration Designer Color Collection: 4-Nail Fastening Pattern 6-Nall Fastening Pattern SureNa,IJ fastemna area viidN Sufeliw'ND fastening area Width H. Typical Na11-Typlcl 1- 12^ I 12 1" t^I 12' r12 f" i 7.�✓mss',„�.— �i Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 i surara6xfauamng area�tan .-Nail.Typical t'” t^•• t2^ t" I Fount"�all�Caman( Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 6'EDITION(2017)FBC NDN-HVHZ EVALUATION FL10674-R13 Owens Corning'AsphaltRoof Shingles Revision 8:10/0912017 Page 5 of 8 INITY, ;ER 6.2.1 Minimum Nailing—Tru Definition'OakridgeO,Oakridge®: 4 Nall Pattern 6 Nail Pattern ESaltema Cen 4 Clavus Esquema con 6 clavus r r IQ— IT �'I u�I Imo— Tt• I {<— ,z' — 1 5 6181 Exposure Nails 5 5.18"Exposu2 idails apaskidude65/Spaig. Matto; Exposicl6nde59/8pufg. 5He"Erposu2 Cfavm 5b/8"Exposure Exposition de.6518pulg. Exposfcdn de 5518pufg. Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater 7han 21:12 swcn.�n�nsio��q..,eo omen f noir.ryp',d 12„ i„ Fora 1"SpeL W ASp1ar Rooting Conran: Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuardO HP: �a 5-ngAla Wde vim F•. :1 Fa 'rtcoct�h Neil lli<ra Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RB Certificate of Authorization X9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8 t I N IT I ERD 6_3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard� HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidge'"' Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2).,nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 . Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire°Hip&'Ridge and High Ridge: Fig.1 Fig.2 firwallbulvdud Direction /_C,� \ti;o\, toPvinv Sidevnsa flails I flails f• I I TaP alma lal PI I } lan i 9" . Exlwwrc 0i �I ul /'� 6.3.4 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.C Hip&Ridge Shingle Fastening Fig.A 9 0 7opvloty. Pravalling Dlmelbn""d \ _ IL lis flail^ 2. I i' ♦ Jr V Y Expa'sula I . Exposure Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate oJAuthorization#9503 6T1 EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 TRINFIi ERR 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard {Mind DirectionFastening Sealant Strip Pattern 6°Exposure w1.1 I"V Sealant � I Fasten Ph" 6"Exposure Cover Exposed Fasteners with Roof Cement 6.3.6 Minimum Nailing—DuraRidgeTm Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. PraraiGngitinj Gi�ecd rT Top View *--Diraaion d rninance di vc �yll- Y ur ell Lu.r DiracdmdalvicnW pradcmimnca - _ ___ clow �ra-� ^" ---"'O:ren.Cca nlce3 Sn[:FlaO'. --- e:un -- floui Zr I -fi6r�rc-. V Ia v {1I r • Iia��s�tL_ v ,. �� 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (631)546-2458;Kanchi.Agrawala-Dokania@ul.com END OF EVALUATION REPORT- Exterior EPORT-Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 6Tr'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8