Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 ' I_y cati. �r x I'� at r- r.?' "!I� 'ter :i ''-' - .. .. ,t S6 � ,..°#��,���;�,• saS Home i Log In ! User Registration Hot Topics Submit Surcharge i Stats&Facts i Publications I FBC Staff BCIS Site Map i Links Search i �Raijdi Product Approval USER:Public User Product Aoyroval Menu>Product or Appl(cation Search>Application List>Application Detail FL FL2569-R14 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Soprema,Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville,NON-US 00000 (819)478-2400 memath ieu@soprema.ca Authorized Signature Marc-Etienne Mathieu memath ieu@soprema,ca Technical Representative Marc-Etienne Mathieu Address/Phone/Email 1688 Jean-Berchmans-Michaud Drummondville, NON-US 00000 (819)478-2400 Ext 3327 memath ieu@soprema,ca Quality Assurance Representative Jean-Francois Cote,Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888)811-3145 j(cote@soprema.ca Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name Who developed Robert J. M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/18/2020 Validated By John W. Knezevich,PE :J Validation Checklist- Hardcopy Received Certificate of Independence FL2569 R14 COI 2018 01 C0I N_IEMINEN_pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D4798 2011 ASTM D6163 2008 FM 4474 2011 FRSA/TRI April 2012(04-12) 2012 UL1897 2012 http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB10... 4/20/2018 Florida Building Code Online Page 2 of 2 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/12/2018 Date Validated 02/14/2018 Date Pending FBC Approval 02/17/2018 Date Approved 04/10/2018 SummarV of Products FL# Model,Number or Description Name 2569.1 Soprema Roof Self adhering roof underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ:No FL2569 R14 II 201802 FINAL ER $OPREMA CA UNDERLAYMENTS FL2569 Approved for use outside HVHZ:Yes R14.pdf Impact Resistant:N/A Verified By: Robert Nieminen,P.E. PE-59166 Design Pressure: +N/A/-150 Created by Independent Third Party:Yes Other:1.)Refer to ER Section 5 for Evaluation Reports Limits of Use. 2.)The design pressure FL2569 R14 AE X018 02 FINAL ER SOPREMA CA UNDERLAYMENTS FL2569 noted herein pertains to underlayment R14.pdf systems used beneath adhesive-set tile Created by Independent Third Party:Yes systems.Refer to ER Section 5.6.4 for details. Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.if you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,j contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,FS.,please click here. Product Approval Accepts: Credit Card Safe _ i I ; http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=WGEVXQwtDgsKQFEnckB 10... 4/20/2018 Certificate of Authorization ft32455 353 Christian Street, Unit#13 .F Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE � TEST - — CONSULTCERTHPI ,Jl` OR Soprema, Inc. Evaluation Report 518010.06.09-1112 1640 rue Haggerty FI-2569-R14 Drummondville,QuebecJ2C 5P8 Canada Date of Issuance:06/15/2009 (819)478-2400 Revision 12:02/12/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprerna Roof Underlayrnents LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality Assurance or the production facility location(s). NEIViOJetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle, ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages.1 through 8. Prepared by: Robert J.M. Nieminen P.E. ° The facsimile seal appearing was authorized by Robert Florida Registration No.59166,FloridaDCA ANE1983 �'�S' � `' Nieminen,P.E.on 02/12/2019. This does not serve as an 9 ::'ri;� i "` electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC,LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2.. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically forthat purpose. r�x` jEI-00 at.Ce y ROOFING COMPONENT EVALUATION: 77 - .g•' ,{�.:.�,,.' �i '":a�M�.FC1�L{ `� 4 .4 ....--S'h k_ :zY." _'T• _ Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Pro a Standard. Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.4/1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008 TAS 110 Accelerated Weathering ASTM D4798 2011 Enti Examination Reference Date ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004 ERD(TST6049) Physical Properties 2757.02:05 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005 ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) Wind Resistance 2779.11.05-111 04/18/2007 ERD(TST6049) TAS 103/TAS 110 57120.11.07-2 11/02/2007 ERD(TST6049) ASTM D1970/TAS 110 S13190.02.09-R1 04/01/2010 ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010 ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1 09/09/2010 ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.09-R2 10/05/2010 ERD(TST6049) ASTM D1970 S37210.11.11 11/09/2011 ERD(TST6049) ASTM D1970 S40540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties/Tensile Adhesion 543530.02.14-1 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015 ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017 M-D(CER1592) HVHZ Compliance 15-0508.04 09/24/2015 ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017 PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL,LLC(QUA9625) Quality Control Service Confirmation Exp.07/18/2020 {i2 f{ ( Iia �rrP � ,. 4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12). 4.2 Lastobond Shield is a self-adhering,,woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch;meets ASTM D1970. 4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment;available in 3.3 ft x 65 ft rolls;meets ASTM D1970. 4.4 Lastobond Shield HT is a self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof underlayment;meets ASTM D1970. WES10 ETC,LLC Evaluation Report S18010.06.09-1112 Certificate of Authorization#32455 6n'EDIT 10N(2017)FBC NON-HVHZ EV'ALUA110N -rL2569-R14 Soprema Roof Underlayments Revision 12:02/12/2018 Page 2 of 8 { 4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch;meets ASTM D1970. 4.6 Lastobond Pro HT-S is a self-adhering,woven polyethylene surfaced, high temperature,SBS modified bitumen roof underlayment;meets ASTM D1970. 4.7 EnviroShield is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.8 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof_underlayment; meets ASTM D1970. 4.9 Lastobond Eaves Protection Sheet is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.10 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.11 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970. 4.12 RESISTO LB1236 is a self-adhering,glass-mat reinforced,sand-surfaced, SBS modified bitumen roof underlayment, with a 36-inch sheet width;meets ASTM D1970. 4.13 PrimeSource Grip-Rite Eave & Valley Protector is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width;meets ASTM D1970. 4.14 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment, with a 44-inch sheet width;meets ASTM D1970. 4.15 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof underlayment;meets ASTM D1970 and FRSA/TRI April 2012(04-12). ( AJ 5.1 This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within .FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: Asy „1 .:m,�-.ei#..u- '_:3°_....»s2n,.� s� `"i` -,• ,.Ca ,.1 �➢ _ -,e+'«a,.af�s.. m.F� Wood or Slate or Asphalt Nail-On Foam-On Composite Underlayment Shingles Tile Tile Metal Shakes& Composite Slate Shingles Lastobond TU HT Yes Yes Yes Yes: Yes Yes See 5.5.1: . Lastobond Shield/Pro HT-N/ RESISTO SA SMOOTH PLY 40 Yes .. No_ No No .: Yes,, Yes Lastobond Shield HT/Pro HT-S 'Yes, `No 'No Yes Yes;. Yes EnviroShield Yes No.. :No Yes Yes Yes NEW ETC LLC Evaluation Report 518010.06.09-R12 Certificate of Authoritotion 1132455 6"EDITION:(2017)F6C NON-HVH%EV UUATION FL2569-R14 Soprema Roof Underlayments Revision 12:02/12/2018 Page 3 of 8 i.. P l E:o c i e-bC Wood or Slate or Asphalt Nail-On Foam-On Metal Composite Underlayment Shingles Tile Tile Shakes& Composite Slate Shingles Lastobond Eaves Protection Sheet/ Lastobond 195 Yes, No Na- No.. Yes Yes Lastobond ECO /RESISTO LB1236, Grip-Rite Eave&Valley Protector/ Yes No' No`:' - No " Yes Yes'" RESISTO LB1244 Lastobond Smooth Seal HT M., Yes. No,,. No Yes : Yes Yes. Colphene FR GR Yes Yes Yes No Yes Yes See 5.5.1' 5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations. d�7 w •Y GIfl �lfs i n !i i cTr ...` ,i`-� �I-.._-.��-�_l,iTd�(,z� t�lf•�,_o ate,� "1_..�t•�k Adhesive Florida Product Approval Underlayments DowTileBond'" FL22525 Lastobond TU HT ICP Adhesives PolysetO AH-160 FL6332 Lastobond TU HT or Colphene FR GR 5.6 Allowable Substrates: 5.6.1 Direct-Bond to Deck: Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to: ➢ Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. Colphene FR GR applied to: Y Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete. N ote: i While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. 5.6.2 Bond-to-Insulation: Lastobond Shield, Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ Dens Deck Prime;SECU ROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on. the systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D, Testing Application Standard TAS 114,Appendix J or UL1807. 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Appioval for Overturning Moment Resistance Performance. NEN-10 ETC,LLC Evaluation Report 518010.06.09-R12 Certificate of Authorization#32455 6"EDITIOM(201.7}FBC NON-NVHZ EVALUATION FL2569-R24 Soprema Roof Underlayments Revision 12:02/12/2018 Page 4 of 8 IN EN101,88tC. 5.6.3 Bond to Mechanically Attached Base Laver: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ ASTM D226,Type I or II felt;Sopra-G;Modified Sopra-G. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2012(04-12). 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012(04-12)does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications. Maximum Design Pressure'is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012(04-12)or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure=-45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. #2 Maximum Design Pressure=-67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. #3 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation:Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional)RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self-adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end- laps. #4 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6-inch o.c.at the.4-inch laps and 6-inch o.c. in three(3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered 5.6.4.1 All other direct-deck, adhered soprema underlayment systems beneath foam-on the systems carry a Maximum Design Pressure-of-45 psf. MEMO ETC,LLC Evaluation Report 518010.06.09-1112 Certificate of Authorization#32455 6"EDITION(2017)FBCiUCN-HVH7EVALUATION F'2559-R14 Soprema Roof Underlayments Revision 12:02/1212018 Page 5 of 9 � x i +`fit Pe-rV yy++ 10 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist'the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk` carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,RESISTO LB1236, Grip-Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation. Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT or Lastobond Pro HT- S,EnviroShield shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or•Colphene FR GR shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)): When loading roof tiles on the underlayment in direct-deck the assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. 16 5 i("' P^ aT;f;,�of' t y`.'V �'G•sa`r`�!P r a��a€'f4!yy�_tf:',KIO� ;LLY�,�s R.- -- Underlaymentr Tile Profile Staging Method Maximum Slope Flat Max.10 the stack 6:12 Lugged Max.10-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack shall be inverted,followed by 8 tiles high 6:12 on slope,as shown below) f1 liri�> K ;z 1 Lastobond TU HT ;t. Lugged s. I Flat Max.10,tile stack 5:12 Colphene FR GR Lugged Max.10-tile stack 6:12 MEMO ETC,LLC Evaluation Report S18010.06.09-1112 Certificate of Authorization#32455 6"EDITION(2017)FRC NOP:-HVHZ EVALU! .01.1 tL2569-13,14 Soprema Roof Underlayments Revision 12:02/12/2018 Page 6 of 8 a F-ulEP`(0 C-C. 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER (if applicable). 6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,EnviroShield,Lastobond_Eaves Protection Sheet, Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,RESISTO 1-131$36,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Colphene FR GR: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table.1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non Tile Applications: While priming is optional,Soprema recommends priming with Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes above 8:12, Soprema recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place,working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR onlyl: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein,and Soprema published requirements for the staging. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MEMO ETC,LCC Evaluation Report S18010.06.09-R12 Certificate of Authorization#32455 6'EDITION(2017)FSC NON-HVHZEVA•LUATION FL2569-R14 Soprema Roof Underlayments Revision 12:02/12/2018 Page 7 of 8 r Contact the noted QA agency for information on product locations covered for F.A.C. 611320-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. Plant specification Product(s) Lastobond Shield,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Drummondville, Lastobond Pro HT-N,Lastobond Pro HT-S,EnviroShield,Lastobond 195, Dr Dr (Canada) ASTM D1970 Lastobond Eaves Protection Sheet,Lastobond Eco,Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley Protector,RESISTO LB1244 ASTM D1970&FRSA/TR1 04-12 Colphene FR GR Wadsworth,OH Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco, ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley Protector,RESISTO LB1244 ASTM D1970&FRSA/TRI 04-12 Lastobond TU HT;Colphene FR GR Gulfport,M5 Lastobond 195,Lastobond Eaves Protection Sheet,Lastobond Eco, ASTM D1970 Lastobond Smooth Seal HT,RESISTO LB1236,PrimeSource Grip-Rite Eave&Valley Protector,RESISTO LB1244 v � 5�•�`' ,��:n e�..�.�:."�+ 4�, 'mss' z R., _ _ �x �...�._,.__..._.u_.e.__._..-..__. - .......a..l �UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- NENIO ETC,LLC Evaluation Report 518010.06.09-1112 Certificate ofAutharization#32455 6'EDITION(2017)FEC NOP!-HVHZ EVALUATION FL2569-R14 Soprema Roof Underlayments Revision 12:02112/2018 Page 8 of 8 rionda tsu>lding Code Online Page 1 of 2 4 b �.. BCIS Home Log In i User Registration Hot Topics i Submit Surcharge i Stats&Facts Publications FBC Staff BCI$Site Map Links Search I k05- Product Approval " USER:Public User Product Approval Menu>1' 4uc[or Application Search>Application,List>Application Detail i . FL# FL10674-R13 _. Application Type YP Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Coming Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscoming.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sanct-dnt@owenscomig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert].M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W. Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R13 COl 2017 01 C01 Nieminen.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Equivalence of Product Standards Certified By Sections from the Code http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2... 1/15/2018 vlortda Building Uode online _ Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 10/10/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R13 II 2017 10 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes SHINGLES FL10674_R13_pcif Impact Resistant:N/A Verified By: Robert].M. Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party:Yes Other:Refer to ER,Section 5. Evaluation Reports FL10674 R13 AE 2017 10 FINAL-ER-OC ASPHALT SHINGLES FLt0674-R13_pdf Created by Independent Third Party:Yes Back Nett Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850.487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do notsend electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: EJ t_ fere 0 relit Ward Safe http://www.floridabuilding.org/pr/prPP_ Pxa dtl.as ? GEVX tBNbEY5VD/o2... 1/15/2018 param=wQwtD q EXTERIOR RESEARCH&DESIGN, LLC. Certificate ofAuthorization#9503 ��TY 353 CHRISTIAN STREET,UNIT#13 OXFORD,CT 06478 (203)262-9245 EVALUATION REPORT Owens Corning Evaluation Report 03794b.02.12-R8 One Owens Corning Parkway FL10674-R13 Toledo,OH 43659 Date of Issuance:02/06/2012 (740)404-7829 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M.Nieminen,P.E. �?FS vl'�c�`ti The facsimile seal a ppea ring was authorized by Robert Florida Registration No.59166,Florida DC4ANE1983 = """"" Nieminen,P.E.on 10/09/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. RINI ER ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section PropertV Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Enti Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp.05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: s 4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire T11 are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition' Duration', Duration Premium Cool, TruDefinition Duration' Designer Color Collection, TruDefinition®Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip&Ridge Shingles: 4.2.1 Berkshire' Hip &Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip &Ridge Shingles and DuraRidge'"'Hip&Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity(ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-98 Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 TRNFYERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vast] = 150 mph (Vue = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd=150 mph (Vult=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 UnderlaVment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC 1507.2.3,1507.2.4 or R905.2.3. 6_2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: > Berkshires shingles require minimum five(5)nails per shingle. i WeatherGuards HP shingles require minimum six(6)nails per shingle. r Devonshire'"shingles require minimum six(6)nails per shingle. y Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus; Felt underlayment Deck Felt underlayment —Deck Self-adhered 1' Weathed ockc"^rl_•� Sel;-adheted YI underlaymem - We fl Lack' f / ,.,�i(,/ nnderlaytnani ` �(4 Drip -- "- Drip edge edge edge Drip edge Drip— ";� edge j idailz Ixated J Nab located 2-3"irmn cave '2"e3'lrom gave Install first Self-sealin adhesive SEraeatingadhesive Starter Strl lnstas rust starter Strip PD., Strip_ positinnew•rlong cave with 5'retnoved U' Positioned along cave shingle with 6"removed Starter Strip shingle overhangs eaves and rakes'.`i=zi' Starter Strip Plus overhangs eaves and rakes IW-3/4^ Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate of Authorization 519503 6'EDITION(2017)FBC NON-H VHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 TR ER 6.2.6 Minimum Nailing—Classic®&Supreme: Normal Mansard or Area para Normal Mansard or Area pare Wind Areas High Wind desvnnes y Wind Areas High Wind desvanes y Area pore vientos normales Areas vientos fuertes Area pare vientos normales Areas vientos fuerfas + i r (B)IA1 — \_�IY 2118 121 e �J •� �IL_�I--I L�JI�J 5"Exposure 6 5/8"Expoauro Eaposicidn Exposicidn 6.2.7 Minimum Nailing—Berkshire®: Saalant strip Sealant strip f La tiro de sellador /La tira de sellador at 3 a o 6-0/ ©—o�—�o 91rA 9 LY' fl V?' } 8 " 81h" 8%" 8+.^_" T. +h e e Standard Fastening Pattern 6-Nail Fastening Pattern Salam strip L3 tlyd V?SYlL4L{Tr 04----------31-04----------)O e 0-----A O 1" 0 r - t Y Asphalt rooting cement Coownto de ceche do aslaho Mansard or Steep Slope Fastening Pattern Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-118 Certificate oJAuthorization/19503 6n+EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-RIB Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 ERD TRIN FY 6.2.8 Minimum Nailing—Devonshire`"": 7" Nast � Gatos Nails 5-5/8"exposure Exposici6n de 5.516 pulq Sealant location Ubicad6n del sellaft Ten 1"Spots of Asphalt Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, Tru Definition® Duration, Duration® Premium Cool & TruDefinition' Duration Designer Color Collection: 4-Nail Fastening Pattern 6-Nall Fastening Pattern SuraNailWaslititing area width M1 Ty&W r N311.7ypl..] 12' 6718-GJ Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 Nag,rypcal 12' G-iffl Mansard or Steep Slope Fastening Pattern Exterior Research and Design,LLC. Evaluation Report 037940-02.12-Rg Certificate ofAuthorization#950 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-RI3 Owens Coming Asphalt Roof Shingles Revision 8-10/09/2017 Page 5 of 8 ED 6.2.1 Minimum Nailing—TruDefinition"Oakridge®,Oakridge®: 4 Nail Pattern 6 Nail Pattern Esquema con a davos Fsquema con 6 davos 1' 1 A' r r Imo— YL' I�-- Y2 �I V. _� �— 12' 56!8"Expo ureNarc 55!8"Exposure Nark Fxposicldrl de 55/8 puig. Claws Exposkl6n de 55/8 puig. 5 618"Exposure Claves 5 5/6"Exposure Eaposki6n ds 5518pulg. Exposic do de 5518 pufg. Standard Fastening Pattern 6-Nail Fastening Pattern Fastening for Slopes Greater Than 21:12 Smn:leilL lasloning oma mitltn tiail,Typic,i o•/E'5.578^ _ � — Four V Spots otAspna:t Rooting Cement Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard®HP: r1' t Single Slate VkW 12 � Vhft/ardc�t! :� :•� FeatocarTleeuah A ldi(tom CRAW esa la ds Exterior Research and Design,LLC_ Evaluation Report 037940.02.12-RB Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 6 of 8 `' TRIM $ @ ED 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard6 HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidgel Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge: Fig.1Fig.2 I Prevalunovdlul /i^\ I �— DIfCQl0,l1 �/ 1.1 < A TaU�I•v SiUeVery nails— Top Natls I nails I7 Lzminalal A \ I 1 I p I A I ✓'��\ \C W\ I 1 I I 1 \ f I j j 51 Exl�e ul J 6.3.4 Minimum Nailing—WeatherGuardO HP Hip and Ridge: Fig.C Hip FI Ridge Shingle Fastening Fig.A 4' d—Deiun WindTopVW- iria j \� 110M raps rmlm I I Y b 7 • Exposure 11 Exposure Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS Certificate of Authorization#9503 6"EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 TRINITY ERD 6.3.5 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard 11" � {Hind Direction Sea',ant StripFastening - Pattern 6'Exposure :\ 12' 1 -—Sealant \ Cover Fasten 7V:" 7'!z° 6'Exposu f re FastenExposed Fasten � ers with _ Roof Cement ---1Z' 6.3.6 Minimum Nailing—DuraRidgeTm Hip&Ridge Shingles: Note:The drawings below pertain to minimum,as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. LD,reaion d I-Mimmo di V�t ueP Mw a P6?n DimcdondolTimtoprodaniraneo t*II' vismsuperior 11Ifn .-,..z ,..n—.. A Nil ilsik �� .` ,'� _� 0�•mnsCmnisttjSus:PlaiP — jz;.' C:uw ��to —lid 1 I i -i'Fap7ac� II�m stin s. �a�ti�1 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS Certificate of Authorization X9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8