HomeMy WebLinkAboutRevisions l I
OFFICE USE ONLY: C�
DATE FILED: �Z_S ' PERMIT#
REVISION FEE: /J RECEIPT# O /
PLANNING &DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
^� FORT PIERCE,FL 34982-5652
(772)462-1553
APPLICATION FOR BUILDING PERMIRE UN
PROJECT INFORMATION
LOCATION/SITE /
ADDRESS: / lV 11111-erce �G� -3
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
e . S b r6((ec� f Odn r L PiU a6'e4
�v�d ec Zt of i at a)
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: ST.LUCIE CO CERT. #:
BUSINESS NAME:
QUALIFIERS NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): FAX:
OWNER/BUILDER INF�O`RMA7TION:
NAME: ae C� d(lP
ADDRESS: /1J. 3
CITY: 1—L, STATE: L ZIP: V9Y7
PHONE( AYTIME: 77,2 FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): FAX:
mm
SLCCC: 9/23/09 RELEIVED
Revised 06/30/17 JUL 3 2018
Permitting Departmient
St. Lucie County, FL
z
Ar% 10
RECEIVED ,
ST. Lucie County, Permitting
',J TR1N1TY j ERD
_
APPENOt%1 ATrAOIf4ENT REQUtRER9ENi5FOR WIND UPLIFT R.E515TANCE ,., .�- ��: •�•�•
Table Deck Application Type Description page
1A Wood New or Remof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 5
16-1 Wood Neworitemof(TearOff) A-2 Mech.Attached Anchor5heet,Bonded Insulation,Bonded Roof cover 5-7
18-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mach.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 8
1C Wood New,Reroof(Tear-Off)or Recover 8 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 9
16 Wood New,Reroof(Tear-Off)or Recover C Mech.Attached insulation,Bonded Roof Cover 10-21
1E Wood New,Reroof(Tear-OM or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 12.13
-1F-1 Wood New orl eroof(tear-Of) E Non-insulated,Mach.Attached Base Sheet(nails),Bonded Roof Cover 14.16
1F-2 Wood New,Reroof(TeaaOff)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 17-19
1G Wood New or Reroof(Tear-Off) F Non-lnsulated,Bonded Roof Cover 19
2A Steel or Structural concrete New,Reroof(Tear-OM or Recover 8 Mech.Attached Base Insulation,Bonded Top lnsutatioq Bonded Roof Corer 20.22
28 Steel or Structural concrete New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 2326
2C Steel or Structural concrete New,Reroof(fear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 27-29
3A Structural concrete New or Reroof(ear-Off) A-1 Bonded Insulation,Bonded Roof Cover 3035
3B Structural concrete New or Reroof(Tear-Off) F Norrinsulated,Bonded Roof Cover 36
4A LWIC New or Reroof(Tear-Oft) A-1 Bonded Insulation,Bonded Roof Cover 37-38
48 tW1C New or Remof(Tea r-0ff) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 38
4C LWIC New orReroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 39.40
5A CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 41
5B CWF New,Remof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 42
SC CWF New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 43
5D CWF New,Reroof(fear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 43
SE CWF New,Reroof(Tear-Off)or Recover E Nort4nsulated,Mech.Attached Base Sheet Bonded Roof Cover 43
6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 44.45
66 Gypsum Remoff7ear-Off)orRecover A-2 Mech.Attached Anchor Sheet Rondo d I nsulation,Bonded Roof Cove r 46
GC Gypsum Reroof(rear-Of)or Recover C Mech.Attached Insulation,Bonded Roof Cover 46
6D Gypsum Reroof(Tear-0it)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 46
7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 47.49
78 Various Recover F Non-Insulated,Bonded Base Sheet Bonded Roof Cover 49
The fallowfne notes apply to the systems outlined herein:
L The roof system evaluation herein pertainsto above-deck roof components.Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. insulation/base sheet fasteners shall be ofsufficlent length for the following deck engagement:
>Wood: Minimum 0.75-inch penetration.
>Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
>Structural concrete: Minimum 1-4nch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyanurate,polystyrene,wood fiberboard,pedite,gypsum-based roof board or mineral-wool roof board that meets the OA
requirements of FAC.Rule 616203 and Is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when Installed with the roof cover.
Eaterlor Research and DesfM LLC.d/b/a Trirdtyl ERD Evaluation Report P40G90.0G.13-R8 for FL164294t3
Certificate ofAuthori ation 09503 6"EDITION(2817)FBCNON-HVtfZ EVALUATION Revision 8:09/12/2017
Prepared by:Robert Nieminen,PE-591% XbaFlex Modified Bitumen RaofSystems,,(S70)3841230 Appendix 1,Page 1of49
1
00 VV 1.7
ST,LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR CO CE
REVIEWED BY
DATE
PLANS AND PER IT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
Fn�'
SIC
7
REV I
-JTRINITYJERD
i
4. Minimum 200 psi,minimum 2-Inch thick lightweight Insulating concrete may be substituted for rigid Insulation board for System Type D(Mechanically attached base sheet,bonded roof cover),whereby the base
sheet fasteners are installed through the LWIC to engage the structure)steel or concrete deck.The structural deck shall be of equal or greater configuration to the steel and concrete deck listings.Roof decks and
structural members shall be in accordance with FOC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified andifor FBC
Approval documentation.
S. Preliminary Insulation attachment for System Type 0:Unless otherwise noted,refer to Section 2-2.10.13 of FM Low Prevention Data sheet 1-29(January 2016).
6. Unless otherwise noted,Insulation adhesive application rates are as follows.Ribbon or bead width is at the time of application;the riblions/beads shall expand as noted in the manufacturer's published instructions.
>Hotasphatt(HA): Full coverage at 25-30 lbs/square.
➢Dow INSTASTIK Quik Set Insulation Adhesive(D-IS): Continuous 0.75 to 1-4nch vvide,nbbore,124nch 0.c.
>Millennium One Step Foarrable Adhesive(M-OSFA): Continuous 0.25 to 0-54nch wide ribbons,12-hich o.c.
)w Millennium PG-1 Pump Grade Adhesive(M-PG1): Continuous 0.25 to 05-Inch wide ribbons,12-Inch o.c.
OMG OlyBond 500(013500): Continuous 0.75 to 1-inch wide ribbons,12-Inch o.c.(PaceCartorSpotShot).Note.,OlyBond Green maybe used where O1y8ondS0Q Is referenced,
OhBond Classic(OB Classic): Full coverage at 1 gallsquare.
➢ICP Adhesive&Sealants CR-20: Continuous 25.35-inch wide ribbons,12-Inch o.c.
>Note.When muldolelayersis)oflruidantionandlor coverbaordareinstalledin ribbon-oppliedadhesive,boomijahitsshollbe staggered.
>Note.,The maximum edge distance from the adhesive ribbon to the edge of the insulation board shollbe not less than one-half the spediledribbowspocing.
7. Unless otherwise noted,all insulations am flat-stock ortapor board ofthe minimum thickness noted.Tapered polyisocyanurate at the following thickness limitations maybe substituted with the following Maximum
Design Pressure(MDP)limitations.in no case shall these values be used to IncreaW the MOP listings in the tables,tether if MOP listing below meets or exceeds that listed for a particular system In the cables,then
the thinner board listed below may be used as a drep-In for the equivalent thicker material listed in the table:
>Millennium one Step Faarnable Adhesive(M-OSFA): MDP -157.5 psf (Min,0.5-inch thick)
>Millennium PG-1 Pump Grade Adhesive(M-PG1): MDP -I57.5 psf (Min.0.5-inch thick)
>OMG OlyBond 500(OB500): MDF -45.0 psf (Min-05-Inch thick Mutti-Max FA-3)
>OMG OIVBond$00(011500): MDP -287.5 psf (Min.0.54nch thick ISO 95+GL)
>OMG OlyBond 500(06500): MOP -315D psf (Min,0.5-Inch thick ENRGY 3)
>OMG OlyBond 500(OB500): MDP -487.5 psf (Min.0.5-Inch thick ACFciatn 11)
>ICP Adhesives&Sealants CR-20: MDP -117.5 psf (Min.1.0-inch thick)
8. Bonded polyisocyanurate Insulation boards shall be maximum 4 x4 fL
9. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI V4131,FM Lou
Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterlsk"carry the limitations set forth in Section 2.210.1 of FIVI Loss
Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements.
10. Forfully bonded assemblies,the maximum design pressure for the selected assembly shall meetor exceed critical design pressure determined In accordance with FBC Chapter 16,and no rational analysis is permitted.
11- For mechanically attached components ever existing decks,fasteners shall be tested In the existing deck for withdrawal resistance, A qualified design professional shall review the data for comparison to the
minimum requirements for the system.Testing and analysis shall be In accordance with ANSI/SPRI FX-1 orTesting Application Standard TAS 105.
22. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing
roof system(for recover)shall be capable of resisting project design pressures on Its own marit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with
ANSIISPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 orTesting Application Standard TAS 124.
13. For RecaverApplicatiom using System Type D,the insulation Is optional;however,the existing roof system shall be suitable fare recover application.
14, Lightweight Insulating Concrete(LWC)shall be cast In accordance with FBC Section 1917 to the satisfaction of the Authority Having ludscliction.For system where spocific LWC is referenced,refer to current LWC
Product Approval for specific deck construction and limitations.For systems where specific LWC is not referenced,the minimum design mix shall be 300 psi.In all cases,the minimum top-coat thickness is2-Inrbes.
For LWC ever structural concrete,reference is mads to FBC Section 1917.4.1,Point 1.
Exterior Research and Deslgi4 LLC.d/b/a Tdattill ERD Evaluation Report P40690.06.0-118 for FIJ6429M
Certificate of Authorization 09503 EDITION(2017)FBC NON-HVHZ EVALUATION Revision&09/12/2017
Prepared by.,Robert Monition,PE-59166 XtraFfeit Mod-Wed Bitumen RoofSystem5;(570)394-IMO Appendix 1,Page 2 of 49
f i
14`5 fii 9 �`•"•?� r) :.( f?l',�_; ��1
15. Unless otherwise noted,referto the following references for banded base Ph or cap sheet applications.
f 'TAkE1 XrrwFiExRooFCovms.
Reference Layer Material Application
BP-AA Base Ply One or more plies XmaF-lex G2 Base,FBCApproved ASTM D4601.Type 11 Hot Asphalt at 2D-40
(Base and Ply sheets,Asphalt- Ply. One or more plies XtraFlex Ply W,XtraFlex Ply VI,FBCApproved ASTM D2178,Type IV or VI lbs/square
Applied) Nate: holt-oppliedsheetsorinsulation shag not be applied to pa tmsurfacedmembrooes.
SBS CA2 Base Ply .One ply XtraFlex SBS GLASS Base(sand/sand),XtreFlex SBS GLASS Interply,XtraFlexSBS POLY Base XtraFlex 35 at 15-2.0
Cap Ply XtraFlex SBS GLASS G,XtraFlex SBS POLY Base,XtraFtexSBS POLY G gal/square
Base Ply or Ply One or more plies XtraFlex SBS GLASS Base(sand/sand or poly/sand),XtraFfex SBS GLASS Interply,XtraFlex SBS POLY Base,XtraFlex
SBS-AA SBS HT 650 Base Hot Asphalt at 2D.40
(SBS,Asphalt-Applied) Cap Ply XtraFlex SBS GLASS Interply,XtraFlex SBS GLASS G,XtraFlex SBS POLY Base,XtmFlexSBS POLY G lbs/square
Note. As halt-oppliedsheets orfnsulationshall not beapplied topol"Imsurfaced membranes.
SBS-TA Base Pty or Pty One or more pliesXtmFlex SBS GLASS Base(sand/poly),XtraFlex SBS GLASS Base(poly/polyh XtraFlex SBS GLASS Interply,XtraFlex
(SBS,Torch-Applied) SBS POLY Base,XtaFlex SBS HT 650 Base _^,,.....-b,.,,. ,r�,. Torch-Applied
Cap Ply XtraF.lex SBS GLASS.Interpty XtraFlexSBS-GLASS G,XtraFtex SBS POLY Base,XtiaFlex$BS POLY G:)
Base Ply One or more.plies%traFhA SBS BASE SA,.) -
SBS-SA Cap Ply 'XtraFlex SBS-GSA-"' � -- _ Self-Adhering
(SBS,Self-Adhering) Nate: Unless otherwise noted,permissible membrane substratesforSBS-SA are limited to the SBS-SA Base Ply options herein,XtraFlex
SBS GLASS ease(Polylsand)or XtreFlex 5BS GLASS Base(pol ylpoly).
APP-TA Base Ply or Ply One or more plies XtmFlex APP GLASS Base XtraFlexAPP S Torch-Applied
(APP,Torch-Apptled) Cap Ply XtraFlex APP S,XtreFlex APP G,XtraFlex Keel APP
APP SA Cap P ,XtraFlex APP G 5A XtraFlex Kool APP G SA
(APP,Self-Adhering) Note: Unless otherwise no led,pen,Riil5tamembiane substrotesforAPP-54 orepmAed to theSBSSA Bose Ply o`pfions'heiehi Xtr6F/eir Self-Adhering
SB.SGLASSBose/pot/sand)orXtroF/e;d*GtAS5Bose lyl of), �I
16. Any of the following FBC Approved coatings maybe applied to the top roof membrane without adverse effect on the system wind load performance. Refer tocurrentRoofing Materials Directory for fire ratings
associated with mating usage.
i XtreFlex 20 Bituminous RoafCoatmg;
'r XtraFtex Bituminous Roof Coating Fibered;
> xtmFtex 80 Emulsion Roof Coating;
> XtreFlex 60Aluminum Roof Coating;
D Xtrariox 65 Aluminum Roof Coating Filtered; ,
Y XtreFlex 70 Premium Acrylic FR Roof Coating;
"r XtraFlex 700 Premium Acryk FR Roof Coating(for granule-surfaced APP or SBS only);
Xtraftex5RC 9600 Nigh Solids silicone.Roof Coating or XtraFlex SRC 8000 Silicone Roof Coating,
17. Dens Deck shall be field-primed with XtraFlex 10 prior to self-adhering membrane application.Refer to tables herein for other priming requirements.
R v IS I0 N
Utertar Research and Design,LLC,d/b/o 7rinttyl l-RD Evaluation Report P40690.06.13-R8 for FU6429M
Certifiate ofAuthorhation R9S03 fir"EDITION(2017)FBCNON-HVHZ EVALUATION Revision S:09/12/2027
Prepared by.RobertNlem(nen,PE-59166 XtraFlex Modified Bitumen Roof Systems•,(570)384.1230 Append&1,Page 3of49
411
REV
----JTR1N1TY1ERD
E NO N ISO E4),BO D
,'5YSTEKTYP S -INSULATEP;MECHA CALLYATrA�HEDEAS�E�tiEET,(U�RM&CPI�kI q EDADO]FtOVI�
system Ded(Note 1) Base Sheet I Roof Eaver(Note15) mop
No. Type Fasten Attach Base Pty Cap (Psi)
DaToRcti-AiP
�As ZZ'
XtMR.X,.GLASS.$a,
Xtramex G2 Base,
Min.ISV32- CertainTeed Glasbase, OMG Flat Bottom Plates(square)with Roolgrip#14, 12-Inch o.c.in 44ach lap and 12-inch ac in two BP-PA Sa5-AA. SRS-SAAPP-SA,58.q.
Inch plywood FirestoneIVIBBaMIM Dekfast Hex(aka,Dekfast PLT-H-2-7/8)With Dakfast 014 or -52.5
Perma4ny 28,Ta mko Glass Trufast 3*Metal Insulation Plate with Trufast HD (2),equally spaced,staggered center rows SSS-TA,APP-TA AASRS-TA.APP-TA
Base or GAFGLAS#75
W-102 Min.19/32- XtraFlex SRS GLASS Base OMG Flat Bottom Plates(square)with Roofgrip 412 12-inch o.c.In 4-inch lap and 124nch a.c.in two BP-AA SBS-AA, SBS-SA,APP-SA,SBS- -60.0
inch plywood (2h equatlyspaced,staggered center cows 58S-TA,A P t-_T& AA,SBS-TA,APP-TA
Delff-t Mex.(aka "4
Dekfast;PLT-H-2-7/8)With Dekfast 414, in4 ';'l
�A 11IRPM
—1 HP,OMG:Ffat—"14-inch Q�C.in tni;44�jp
JW515/32-10 1FXt7nvhncG2,qa�XtraFt��it0Mqr3jRm6LWe7��,I_A Joe
Inchp
1= tra hRo7ofgrijJ#14or.TAjfastr . eqV'4jIy O�ced,staggered center E%�� �-SBS�T P-TA
yt��, cj� kAP
w'
so, pla.M,
Dekfast Hex(aim,Dekfast:PLT-H-2-7/8)with Deldast#14,
W-104
Mir,15/32- XtraFlex APP GLASS Base OMG 3'Round Metal Plate with OMG HID,OMG Fiat 10-Inch o In 4-Inch lap and 104nch o.c in three APP-TA APP-TA -75,0
Inch plywood Bottom Plate(Accatrac)with floolgdp 014 orTrufast 3' (3),equally spaced,staggered center tows
Metal Insulation Plate wRhTrafaStHD.
Dekfast Hex(aka.Dekfast:PLT-H-2-7/8)with Dekfast 414,
MUL 15/32- Xtranex G2 Base,XtraFtex OMG 3*Round Metal Plate with OMG III),OMG Flat "ch o.c.In flinch lap and 9-inch o.c In four(4), BP-AA,555-AA, SB54A,APPSk SBS-
W-105
Inch plywood SBS GLASS Base Bottom Plate(Accutrac)with Roofgrip#114 or TrufastY' equally spaced,staggered center rows SBS-TA,APP-TA AA,SBS-TA,APP-TA -90.0
I Metal Insulation Plate wRhTrufavt MD.
Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with.Dekfast#14,
W206 Min.15/32- XtmFIex APP GLASS Base OMG 3Round Metal Platewith OMG RD,OMS Fiat 94nch o.c.in 44nch lap and 9-Inch o.c.In four(4), APP-TA APP-TA -90.0
Inch plywood Bottom Plite(Accutrac)with Roafgdp#14 orTmftst r equally spaced,staggered center rows
I Metal Insulation Plate with Tru"MD.
W-107 Mlo.15/32- Trufast#22 OP orTrufast#14 HDwithTrufast 34 Metal 6-inch ac.at44nch lapand 64nch o.c.Inthree(3),
inch plywood XtraFtex$85 GLASS Base insulation Plates equally spaced,staggered center rows BP-AA or SBS-AA SBS-AA -90A
SBS-
Mtn.15/32-
OMG#12St-dard Roofirrip,orOMG#14 Heavy Duty(min.
W-108 XtraFlex$BS GLASS Base 1-5/84nch long)With OMG 3"Round Metal Plates orOMG 64nch ox at 4-Inch lap and 6-inch o.c.In three(3), -AA,SOS-AA, SBS-SA,APP-SA,SBS- -90.0
Inch plywood Fiat Bottom Metal Plates equally spaced,staggered center rows SBS-TA,APP-TA AA$95--]`A,APP-TA
Min.15/32- OMG H12Standard Rootrip orOMG#114 Heavy May With "ch ox-at 44nch tap and G-inch oz.in three(3).
W-109
inch plywood XtmRexAPP GLASS Base OMG 3"Round Metal Plates orOMG Flat Bottom Motal APP-TA APP-TA -90.0
Plates
I equally spaced,staggered center rows
W-110 Min.15/32- XtraFlex5B5 GLASS Base Trufast 012 DF orTmfast#14 HD with Trufast r Metal 6-inch oc at,14nch lapimt:16-inch o.c.in five(5), BP-AAorSBS-AA SBS-AA -120.0
inch plywood— Insulation Plates equally spaced,staggered center rows
MfM 15/U- OMG#125tandard RooIBrIporOMG 014 Heavy Duty with
W-111 Inch plywood XtraFlexSBS GLASS Base later
MG 3w Round Metal Plates orOMG Fiat Bottom Metal 6-inch G'Q at 4-Inch lap and 6-Inch o.c.In five(5). SP-AA,SBS-AA, SBS-SAI APP-SA,SBS- -120.0
Plates equally spaced,staggered center rows SBS-TA,APP-TA AA,SIBS-TA,APP-TA
'W-112 I Min.15/32- OMG#12 Standard Rootripor CMG#14 Heavy Duty with 64nch o.c at 44nch lap and 6-Inch o.r.In five f5l.
inch plywood Xtraflex APP GLASS Base OMG r Round Metal Plates orOMG Flat Bottom MQt2f equally spaced,staggered center rows APP-TA APP-TA -1204
Plates I
Exterior Research and Design,LLQ d/b/o Trinity)ERD Evaluation Report P40690.06.aR8 for FL1642949
Certificate afAuthorkation#9503 bro EDITION(2017)FBCNON4iVHZ EVALUATION Revision 8-09/IWZD17
Prepareeltr1r.Robert Nieminen,PE-59166 XtraFtex Modilied Bitumen Ro*fSystemr(570)384-1230 Appendix 1,Page 18 of49
-W4"A
J TRINITY JERD
"° ' c TABLEIF2:.WOODDECKS—NEWL[1P15TRUCTIpN REROOF{TEAR-0F'{}oRRcmy�et ,' - -
SYSFEIV(iYPEE P)ON-INStAA3ED,MECt{AN)CtiU4TFACFfEO8A5g5F)EET(ptwws$aATcs};•60NDEDRDOCOVER
System Basesheet Roofcover(Note 15) MDp-
Na. DtKic{Notes)
Type Porten Attach Base Pty Cap (Psi)
' - s
XtraFlex 585 GLASS Base, _ -
XtraFlex G2 Base, OMG Flak Bottom Plates{square}with Roo(grip fr14,
W89 MIn.19/32- Certain'Glasbase, DMG Fl Het{aka,PlateDekfas((square)
with with Deldas,1114 or 12-Inch o.e in 4-Inch lap and 12-inch o.c in two Hone SBS-AA,58STA,APP.
inch
gk/woad Firestone MB Base, Trufast 3'Metal Insulation Plate with Trubst HD (2),equally spaced,staggered center tows TA
Perma•Ply 28,Tamko Glass
BasaorGAFGiAS#75
W-90 Mm"19/32 XtraFlex SBS GLASS Base OMG Flat Bottom Plates(square)with Roofgrip#12 12-Inch o.c in 44nch lap and 12-Inch 0-in two None SBS-AA,SBS-TA,APP- -6D.0
Inch plywood 1 (2),equally spaced,staggered center tows TA
Dekfast Hex(aka,Dekfast PLT-H-2-7/8)with Dekfast#14,
'
Mia 15/32- XtraflexG2 Base,XtraFlex OMG 3'Round Metal Plate with OMG HO,OMG flat SO-inch o.c.in 4-inch lap and 1D-inch o.c None in three SBS-AA,SBS-TA,APP-
WAl inch plywood SBSGLASSBase Bottom Plate(AcMy rac)with Roofgrip#14 GrTrubst 3' (3),equallspaced,staggered center rows TA -75.0
Metal insulation Plate with Trufast HD.
Dekfast Hex(aka,Dekfast PLT-W24/8)with Dekfast 014,
W-92 Min.15/32- X[raflex APP GLASS Base OMG 3'Round Metal Plate with OMG HO OMG Flat 10-inch mcc in 4-inch lap and ID-inch ac,in three None APP TA -75.0
Inch plywood Bottom Plate(Accutmc)with Roofgrip#14arTrufast r (3),equally spaced,staggered center rows
Metal Insulation Plate with Trufast HD.
Dekfast Hex(aka,Dekfast PLT-H-2-718)with Dekfast 914,
Mia 15/32- Xtraflex G2 Base,XtraFlex OMG 3'Round Metal Plate with OMG HD,OMG Flat 94nch o.c in 4-inch lap and!]-inch me in four(4), SBS•AR,SBS-TA.APP-
W93 inch plywood SBS GLASS Base Bottom Plate(Acattrac)with Roofgrip#14 or Trufast 3' None A0.0
equally spaced, TA
Metal insulation Plate with Tn&dst HD.
Dekfast Hex(aka,Dekfast PIT-11-2-7/8)with Dekfast#14,
Mia 15/32- OMG 3'Round Metal Plate with OMG HO,OMG Flat 94nch o.c in 4-inch lap and 9-inch o.c In four(4),
W-94 inch plywood XtraFlex APP GLASS Base -Bottom Plate(Accutmc)with Roofgdg 914 orTrufast r equally spaced,staggered center rows None- APP TA -90.0
Metal Insulation Plate with TmW HD.
W-95 Mm.15/32
tXvaF{exiBSGLAS58ase T"d� c
#12DPorTruFast914HDwithTrufart3'Metal 64nchoat4-inch lap and 6•Incho.clnthree(3), None SBS-AA -90.0
inch plywood Insulation Plates equally spaced,staggered center rows
Min.15/32- OMG#12Standard Roofgdp orOMG#14 Heavy Duty with 64nch 0.e atA-inch lap and 6-inch o.c.in throe(3), SBS•AA,S85-TAor
W-96 Inch plywood XtraFlex SBS GLASS Base OMG 3'Bound Metal Plates or OMG flat Bottom Metal equally spaced,staggered center rows None APP-TAA •90.0
I
k Min.15/32- OMG#12 Standard Roofgtip or OMG#14 Heavy Duty with 6•inch o.c ai4-inch tap and Ginth of in three{3),
W-97 inch plywood XtraFiexAPP GLASS Base OMG 3'Round Metal Plates orOMG Flat Bottom Metal equa#yspat44naggeredd 6-hachnter x- None APP-TA -90.0
Plates
ws
W-98 Min.15/32 XtraFlex SBS GLASS Base TmNst912 OF orTmfast 414 HD with Trufast 3'Metal 64nch o.c at 4-inch lap and 6-inch o,G in five(5), None SBS-AA -120.0
Inch plywood Insulation Plates equally spaced,staggered center rows
Min.15/32- OMG#12Standard Roofgripor OMG N14 Heavy Dutywith &Inch o.c.at4•inth lap and 6•ittch o.e in five(S), SBS-AA,SBS-TA or
W99 inch piywoed XtraFlex SBS GLASS Base CMG 3'Round Metal Plates or OMG Flat Bottom Metal equally spaced,staggered tenter tows None APP-TA -120.0
Plates
Min.15/32- OMG#12Standard Roofgrip orOMG#14 Heavy Duty with 6-Inch o,c at 4-Inch lap and 6-inch o.c In fwa(5),
W-100 inch plywood XtraFlex APP GLASS Base OMG 3'Round Metal Plates or OMG Flat Bottom Metal equally spaced,staggered center tows None APP-TA -120A
Plates
Exterior Research and Design,U.C.d/b/a Trinity)ERO Evaluation Report P40690.06.13-RB forFL16429-M
Certificate Of Authorization#9503 6 EDITION(2017)FBCNON-HVH2EVALUATION Revision 8:09/12/2017
Prepared by:Robert Nieminen,PE-59166 XtraFlex Modified Bitumen RoofSystemr(570)3841230 Appendix 1,Page 17 of49
r
l„ ,0r44
IL
ti,",,TRIN11 Y ERS
c;; ' k TABLE 3A STRU[T3IRALCONCRETEDECt{$ NEiAtCl7NStRt)CTtONORREROOy(iFltR-OcFj r f i
SYE
3
SY MTYPEAI:`BONOED(NSUWTIONBONbEOROOFCOVER ti
t
NOFE;,FapVAPORBARRIEROPIIaNSREFER7oNOTEIS
System Aedt Primer Base Insulation layer Top Insulation layer Roof Cover(Heft xs) MDP
No. (xoeex) Type Attach Type Attach Base Ply Ply Cap Ply (ice
.3ftY-{faxfRBIa BKEW[lit BItSE tx50iATbNANDOPf�W1lTOP lNStnMr1 OFMsnufTYVE:
Structural (opaonall (Optional)additional layers(s)of base (Optional)SBS-SA, SBSSA,APPSA,
G1 concrete MFIOLIO Min.2S-inch H-Shieldor Muft'rMax FA3 13.15 D-IS SBS-5A -61S
Insulation 565-TA,APP TA SBS-TX APP-TA
Structural (Optional)additional layers(s)ofbase (Optional)5&S TA
G2 concrete None Min.iS-isrch Polythemt H,H-Shield ws Insulation w5 5BSSA APP-TA SBS-TA,APP TA d-120.O
C3 Structural topuamil Min.15-inch XtraFlex Polyiso,ACFoam It or D-IS (Optional)additional layers(s)of base 6U^ 595SA (Optional)SBS-SA, SBS-SA,APP-SA,
concrete xtraFlpr to ENRGY3 Insulation SBS-TA,APPTA SBS-TA,APPTA
CA Structural None Min.154nch,min.IS pcf lnsulfoan w5 (Optional)addYiumai layers ofbase w5 SBS-SA (Optional)SBS-SA 585-SA,APP-SA
concrete insulation -
Stmclucot (Optional)additional layers of base
C-S concrete Nona M1n.1S4nch,min.20 pcf Insulfoam OB500 insulation OBSoo SBS-SA (Optional)SBS-SA SBS-SA,APP-5A
Structural (Optional)additional layers(s)ofbase (Optional)SBS-TA,
CS concrete None Min.1.54nch XtraFlex Polyiso,ACF❑am 11 oB500 insulation OB500 SBS-SA APP-TA S&S-TA,APP-TA -1225
C7 Structural None Min.lS4nch ENRGY3 OB500 (Optional)additional layers(s)ofbase OBSOO SRS-SA (Optional)SBS-SA, SBS-SA,APP-SA, _1275
concrete Insulation 5B5-TA,APP-TA SBS TA,APP-TA
C8 Structural None Min.154nch Polytherm H or H-Shleld OBSOG (Optional)additional layers(s)of base Dam 585-SA (Option al)SBS-SA, Sits-SA,APP-SA,concrete
0
concrete Insulation SBS-TA,APP-TA SBS-TA,APP-TA
Min.1.54nch XtraRex Potyao,ACFcam B,
Structural, M-0SFAor insulation
additions layers(s)of base M-0SFAor (optional}SBSTA,
FCC-:0
concrete Nona ShieFlex Polyisa G,ACFoam iii,PotythemtH,N- M-pGl insvlatian M-PGS SBS-SA APPTASBS-TA,APPTA -1725
Shield2.5
Structural Min.15-inch Xtraflex Polyiso,ACFoam ll, (Optional)additional layem(s)ofbase (Optional)S8$-SA, SBS-SA,APP-S&concrete Nona ENRGY 3,H-Shield or Mufti-Max FA3 M-0SFA insulation M-0SFA SBS-SA SBS-TA,APF-TA 565-TA,APP-TA
-�
Min.14nch XtraFlex Potyiso,ACFoam 11,
C-11 con
XtraFlex P❑lyiso G,AACFoam,ACFoam,11,EnergyGuard (Optional)additional layers(s)of base
con c ere lyis
I M-OSFA or M-0SFAor
concrete None Paa Insulation,ENRGY 3,Polytherm H,H. M PGl insulation,optionally primed with M-PGl SBS-SA None SBSCJt2 -290.0
Shield,ISO 95+GL.Mufti-Max FA3,RESISTA or WB-3000
Oltramm
Structural Min.1.54nch Xtraflex Polylso,ACFcam It, (Optional)additional layers(s)of base (Optional)SBS-TA,
C-12 concrete None Polytherm H,HShleld -20 Insulation CR-20 SBS-SA APP-TA SOS-TAX,APP-TA -1225
Gia Structural None Min.LS-Inch,min.20 ptfinsulfoam CR-20 (Optional)additional layers ofbase CR-20 SBS-SA (Optlonai)SBSSA SBS-SA,APP-SA -240.0
concrete insulation
Structural Min,24nch Xtraflex Potyiso,ACFwrn 11, 08 Classic (Optional)additional layers(s)of base OB Classk (Optional)SBS-SA, SBS-SA,APP-SA,
LC-,
concrete None Palytherm H orHShield (full. ) insulation ((full-coveSBS-SA SBS-TA,APP-TA S85-TA,APP-TA -270.0
CoverageMin.154nch XtraSex Polyiso,ACFoam II,
Structural XtraFkx XtraFlex Polylso G,ACFoam BI,ENRGY 3, Not (Optional)additional layers(s)ofbase Hot SBS-SA (Optional)SBS-SA, SBSSA,APPSA,
concrete 10 Polythene N,H-Shield,H-Shleld CG or Multi. asphalt Insulation asphalt SBS-TX APP-TA SBS-TA,APPTA -480.0
Max FA3
Exterior Research and Design,tiC.d/b/a TrnNylERO Evaluation Report P40690.06.13-118 for FL16429-R8
Cert7ate of Authorization 89503 6t”EDITION(2017)FRC NON41VHZEVALUATION Revision 8:0911212017
Prepared by:Robert Nieminen,PE-59166 XtraFtet Modified Bitumen Roof Systems;(570)384-1730 Appendix 1,Page 30 of 49