HomeMy WebLinkAboutBuilding Permit ApplicationALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date:
Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential
PERMIT APPLICATION FOR: To Select from dropbox, click arrow at the end of line
('PROPOSED IMPROVEMENT LOCATION:
Address: 8650 Pine Martin Ln. Fort Pierce, FL 34947
Legal Description: Timberlake Estates Lot 36 (0.93 AC) (OR 3000-1
Property Tax ID #: 2302-601-0040-000-0
Site Plan Name:
Project Name:
Setbacks Front Back:
Right Side: Left Side:
Lot No. 36
Block No.
DETAILED DESCRIPTION OF WORK: J
replace 23 windows size for size (FL 5419.1 - Window) (FL 15534.3 - Mullion)
CONSTRUCTION INFORMATION:
Additions wor to e e orme under tispermit—c ec a appy:
E1HVAC 11 Gas Tank Gas Piping _ Shutters ❑ Windows/Doors
11 Electric 0 Plumbing ❑Sprinklers El Generator E]Roof
Total Sq. Ft of Construction: _
Cost of Construction: $ 35494.00
5 Ft. of First Floor: _
Utilities: Sewer DSeptic
Building Height:
OWNERAESSEE
CONTRACTOR:
Name Cheryl Handy
Name: Raquel Swanner
Address:8650 Pine Martin Ln.
Company: The Home Depot
City: Fort Pierce State: FL
Zip Code: 34947 Fax:
Phone No.
Address: 6500 NW 12TH Ave. Suite 110
City: Fort Lauderdale State: FL
Zip Code: 33309 Fax:
Phone No. (754) 224 - 2010
E-Mail:
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
E-Mail: Jonathon.thomas@expeditepermit.com
State or County License: CGC1514813
If value of construction is $2500 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER:
Name:
_ Not Applicable
MORTGAGE COMPANY:
Name:
_ Not Applicable
Address:
Address:
City:
Zip: Phone:
State:
City:
Zip: Phone:
State:
FEE SIMPLE TITLE HOLDER:
Name:
Not Applicable
BONDING COMPANY:
Name:
_Not Applicable
Address:
Address:
City:
City:
Zip: Phone:
Zip: Phone:
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first inspection. If you intend to obtain financing, consult with lender or an attorney before
commeAe4i kwork or recsfdinp-vour Notice of Commencenlen.L_ X it _
Lessee
FLORIDA
OF 54 Lw_u
The forgping instrumen was acknowledged before
me this l �C day of u, 20 Eby
.A
person
of Ud€a y Public- State of Florida )
Personally Known x OR Produced Identification
Type of Identification Produced
og�y Jonathon Thomas
Commission No. ! ° (bQTIkRY PUBLIC
§ ESTATE OF FLORIDA
STATE OF FLORIDA
COUNTY OF gy- Litae_
The f rgoing instryym nt was acknowledged before me
this day of J", 20_1$by
(Name of
of ITtary Public -State
Personally Known x OR Produced Identification
Type of Identification Produced
Commission No.
A$904n Thomas
NOTARY PUBLIC
'1M1'CE len` Expires 9/18/2021 y2 Comm# GG141189
Revised 07/15/2014 s'Noeien� Expires 9/18/2021
REVIEWS
FRONT
ZONING
SUPERVISOR
PLANS
VEGETATION
SEA TURTLE
MANGROVE
COUNTER
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
REVIEW
DATE
COMPLETE
INITIALS
JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY
FILE # 4456739 OR BOOK 4155 PAGE 1767, Recorded 07/11/2018 01:38:33 PM
Prepared 9Y: The Rome Deoct
16500 NW 121h Ave Sale a 110
Fort Laauderdalo, FL 33309
Permit Nil, U ' • Eri N EM N
I'rcVerty ldcntifrcation No. 2302-601-0040-000-0
THE UNOFRSIGNED hereby gives notice that improvements will be made to certain sea roperty, and in accordance with Section
713.I; of the f�lorida Statutes, the following information is provided in the NOTICE OF �Ot�tMENCEMENT.
I . Description of property Uega! description;) jimDQrlake Estates Lot 36 (0.93 AC)OR 3000-1129)
a) Street Address: 8650 Pine Martin Ln. Fort Pierce, FL 3-47V—
2. General descriptions of itnprvvemettts _ windows
3 Owner Information
a) Name and address: Cheryl Handy 8650 Pine Martin Ln. Fort Pierce, FL 34947
b) Name and address of fee simple titleholder (if other than owner) CAMP
c) Interest in property owner '
4. Contractor Infornation '►,
a) Naine and address -THE HOME DEPOT 6500 NW 32th jive Suite # 110 Fort Lauderdale, FL 333Q9
b) Telephone: No.: 754-224 2010 Fax No. (Opt.)
S. Surety Informations.
a) Name and address: w�
b) Amount of Bond: �
c) Telephone No.: Fat No. (Opt.)
6. 'Lendet
a) Name and address: «"
7. Identity of person within the State o1'Florida designated by owner upon whom notices nr other documents may be served:
s) Name and address: wA '
b) Telephone No.: Fax No. (Opt.), _
8. In addition to himself, owner drsignatcs the following person to receive a copy of the ienor's Notice as provided in Section
713. l3(1) (b). Florida Statutes:
it) Marne and address: wA
b) Telephone No.: Fax No. (Opt.)
9. Expiration date of Notice of Commencement (the expiration date is one year from fire ate of recording unless a different date is
specified). N/A
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER TH EXPIRATION OF THE NOTICE OF
COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHA TER 713, PART 1. SECTION 733.13,
FLORIOA STATUTES AND CAN kESULT IN YOUR PAYING TWICE FOR 1PR( VENIEN rs TO YOUR PROPERTY. A
N(yf1iCE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE 13EFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR 1;.E DER OR AN ATTORNEY BEFORE
COMMENCING WORK OR RECORDING YOU NOTI E OF COMMENC
of
r..
Mr
STAVE OF b't.tin t �r
COU:�r'' or
rat l O►It} xcrllllrecttx/P
`k /Dora',
Not !Js,IJ/ V I
! hr Wtcgt►iug inaltutneltt �r.ly ul knwvkdgad lutY +e Otis Addy of !a' . 20 A, by
(type of ai thority. e.g. of leer, trust attorney is act) for
BPI E inamc of party on be.Wl'ofwlom ins tr was executed).
reiminally Known OR Pmduccd klentiil-katiun Ntxo t Sicowurr
(/ �j' f
f�•pc ��I ldclstifiattlun Prtsductd Name (print( _-
�r rr:li4ation pursvont to Section V2 S? S. Florian Statutes. Under penalties of perynry l declare that I v ad the foregoing and that tux; Puts soled
in it arc true to the befit of m) kno%vkdi a and Nlief:
• r
IgnLuSiv/�f'..ii.+�er1 y .r�M � t..r. MMt
N�ia UfV1j Pub1C Static or Ftortaw
Ftrtv+n C Walsh Sr
m
'1 Mr comas�,3G 1Z6S39
A� �� Fxpass 07119=2 t
s lam; JP
W
CIJ
Home Improvement Agreement: Page 1
Home Depot License Number(s): Visit www.homedepot.com/c/SV_HS_Contractor_License_Numbers for latest license info
FL: EC0001440, CGC1514813, CRC046858, CAC1813767, CFC1426021, CFC1427642, 22640, CAC 1818831,
CCC1331113, CCC1331130
Salesperson Name: Kevin Walsh Registration No. (if applicable):
Home Depot U.S.A., Inc. ("Home Depot") or service provider named below ("Service Provider") will
furnish, install or service the equipment listed below at the price, terms and conditions as outlined on
this form.
HANDY CHERYL
Customer Last Name Customer First Name
8650 Pine Martin Lane
Customer Address
(772) 528-5972 11
Home Phone# Work Phone# Cell Phone#
Miami I I
R@i /D1-6--?qT5
Store # / Branch Name Lead/Customer Order #
Fort Pierce FL 34947
City State Zip
handy84408@ymail.com
Customer Email Address
NOTICE OF RIGHT TO CANCEL: YOU MAY CANCEL THIS AGREEMENT WITHOUT PENALTY OR
OBLIGATION BY DELIVERING WRITTEN NOTICE TO HOME DEPOT AT HOME DEPOT USA INC.,
2455 PACES FERRY ROAD, BLDG. B-3, ATLANTA, GEORGIA 30339 or EMAIL
The Home Depot ----]@ customercancellationsouth@homedepot.com
BY MIDNIGHT ON THE THIRD BUSINESS DAY AFTER SIGNING, UNLESS THE STATE
SUPPLEMENT PROVIDES A DIFFERENT CANCELLATION PERIOD. THE STATE SUPPLEMENT
CONTAINS A FORM TO USE IF ONE IS SPECIFICALLY PRESCRIBED BY LAW IN YOUR STATE.
YOUR PAYMENTS WILL BE RETURNED WITHIN TEN (10) BUSINESS DAYS AFTER HOME
DEPOT'S RECEIPT OF YOUR NOTICE. YOU MUST MAKE AVAILABLE FOR PICKUP BY HOME
DEPOT OR SERVICE PROVIDER, AT YOUR SERVICE ADDRESS, AND IN SUBSTANTIALLY THE
SAME CONDITION AS WHEN DELIVERED, ANY MERCHANDISE OR MATERIALS DELIVERED
TO YOU. OR YOU MAY CONTACT HOME DEPOT FOR INSTRUCTIONS REGARDING RETURN
SHIPMENT AT HOME DEPOT'S EXPENSE.
THE LAW REQUIRES THAT HOME DEPOT GIVE YOU A NOTICE EXPLAINING YOUR RIGHT TO
CANCEL. PLEASE SIGN W TO A HAVE BEEN GIVEN ORAL AND
WRITTEN NOTICE � ANCEL.
Acknowledged by: 06/29/2018
emTrIs a ure Date
Contract Pric and P yment Schedule ment of the Contract Price is due upon signing unless a
different payment schedule is required by law, specified below or in a payment addendum.
Contract Price: 35494.30 1 Includes all applicable taxes. Excludes finance charges.*
Sales Tax: 10.00 (If applicable)
*Maximum deposit ONL Y applicable in MD, MA, ME (3391o), NJ, Wl (99%)
Dep. 25.0 1 % Deposit Amount 8873.58 Remaining Contract Balance 26620.72
--7
The Home Depot - 2455 Paces Ferry Road, N.W. Bldg. B-3, Atlanta, Georgia 30339 - Customer Care: 1-800-466-3337
Customer Agreement (C,E,I) (31 Jan. 18) v 50.1.2
Home Improvement Agreement: Page 2
* Finance Charges : Any interest payments or other finance charges will be determined by
Customer's separate cardholder or loan agreement, to which Home Depot is NOT a party, and will
be in addition to Customer's payment under this Agreement. Customer is subject to the terms and
conditions of the cardholder or loan agreement, as applicable. No funds should be made payable to
Service Provider; however, Service Provider may collect Customer's payments made payable to Home
Depot.
Insurance proceeds will will not be used to pay some or all of the total amount of sale.
Description of Work to be Performed : A detailed description of the work to be performed is included
in the paragraph entitled Scope of Work or Specification which is included in this Agreement.
Anticipated Delivery Date / Installation Schedule
Approximate Start Date: 08/24/2018 Approximate Finish Date: 1 09/21/2018
All dates are approximate and subject to change based on unforeseen events including inclement
weather, permitting delays, and delays in confirming insurance coverage of Your claim for any repair, if
applicable.
Electronic Records Authorization : You are entitled to a paper copy of this Agreement if you
choose. If you consent to an e-mailed copy, your consent applies to this Agreement and all subsequent
documents and written communications related to this Agreement. By contacting your Service Provider,
you may update your email address, withdraw your consent, or obtain a paper copy of the Agreement or
related documents at no charge. By providing your consent and verifying your email address above, you
confirm that you have access to a computer that can receive and open emails and PDF documents.
B initia i this paragraph, I consent to receive only electronic records related to this transaction.
'al
e tance and Authorization : By signing below, you authorize Home Depot to: (a) arrange for
Service Provider to perform any Services or (b) order and arrange for the delivery of special order
merchandise, including special order merchandise that may be custom made, as specified in this
Agreement. Do not sign if blank or incomplete. (Service Provider's or permitting information may need to
be provided to You later.) By signing, you acknowledge that: (i) You have read, understand, and accept
this Agreement in its entirety, including the General Conditions and State Supplement, if any; (ii) You
are receiving a complete copy of this Agreement; and (iii) all rights and interests under this Agreement
are solely vested in the person listed as "Customer" above.
X 06/29/2018 The Home Depot
stomer's Signature Date Service Provider Name
06/29/2018 6500 NW 12TH AVE SUITE 110
Co -Signer (if Date Service Provider Address
06 18 FT.LAUDERDALE 133309
5f of Ho Date City State Zip
2eEnMbP-?18&0tMProvider Phone # Service Provider License Number
The Home Depot - 2455 Paces Ferry Road, N.W. Bldg. B-3, Atlanta, Georgia 30339 - Customer Care: 1-800-466-3337
Customer Agreement (C,E,I) (31 Jan. 18) v 50.1.2
The Home Depot General Terms & Conditions
1. DEFINITIONS: "Agreement" means the Home Improvement Agreement between You and Home Depot, plus (a) any
Change Orders; (b) the State Supplement, if any; (c) these General Terms and Conditions ("General Conditions") and
any documents referenced in or attached to any of the foregoing. "Defect" means any Services that are found not to be as
warranted. "Home" means the real property, fixtures and any physical improvements where the Services are performed.
"Services" means (1) the delivery and furnishing of goods, equipment, materials, and hardware; and (11) any related labor and
services, including without limitation, construction, consultation, fabrication, erection, installation, inspection, maintenance,
repair, and testing. "Service Provider" means an independent contractor, authorized by Home Depot, and its employees,
agents, and subcontractors. "Work Area" means any property, buildings, or structures necessary for the staging, temporary
storing and performance of the Services. "You"/"Your" means the customer identified in the Agreement.
2. HOME DEPOT'S RESPONSIBILITIES: Home Depot or Service Provider will complete the Services in a workmanlike
manner and in accordance with applicable law without causing damage to Your Home, provided, however, that Home Depot
or Service Provider will not start or continue with any Services upon discovery of any condition at Your Home that Home
Depot or Service Provider deems in its sole discretion to be hazardous or unsafe. Unless specifically contracted to do so,
neither Home Depot nor Service Provider is obligated to repair such pre-existing hazardous or unsafe conditions.
3. ASSIGNMENT/SUBCONTRACTING: Home Depot and Service Provider may assign this Agreement, or any right herein,
or any monies due or to become due hereunder, and may delegate or subcontract any obligations or Services hereunder
without Your consent. This Agreement shall not be assigned by You without first receiving Home Depot's written consent,
which may be denied in Home Depot's sole discretion.
4. YOUR RESPONSIBILITIES: (a) Payment: You agree to pay Home Depot in full for the Services pursuant to the terms
of this Agreement. (b) Safe Access: You agree to provide Home Depot and Service Provider Safe Access to Your Home.
"Safe Access" means safe and complete access to the Work Area, including, without limitation: (1) obtaining in advance
of the Services consent, permission, or relief from any covenants, easements, restrictions, or other legal encumbrances
affecting the Work Area; (2) providing the location of utilities, whether underground, concealed, overhead or visible, to
Home Depot or Service Provider; (3) removing from the Work Area physical impediments, hazards, and building code or
zoning violations that affect directly or indirectly the Work Area; (4) removing unsafe working conditions and hazardous
materials, including environmental hazards, from the Work Area; (5) providing sanitary facilities to Home Depot or Service
Provider convenient to the Work Area (or, alternatively, paying for the rental costs of such facilities); (6) providing all
utilities, including without limitation, power, water, ventilation and climate control, in and for the Work Area; (7) removing
from and protecting against minors, pets, guests and visitors in the Work Area; (8) keeping permits, if required, visible
at all times; (9) disengaging, suspending or terminating any security systems protecting the Work Area; (10) providing
adequate temporary storage space as needed for Home Depot's or Service Provider's performance of the Services; and
(11) not interfering, impeding, impacting or otherwise disrupting the Work Area at any time during Home Depot's or Service
Provider's performance of the Services. (c) No Performance: Services are to be performed by Home Depot or Service
Provider. If You attempt to perform or assist with the Services in any way, You assume all risk for property damage and for
injury to Yourself and others.
5. MODIFICATIONS AND CHANGE ORDERS: Without invalidating this Agreement, You may authorize Home Depot or
Service Provider to perform Services beyond the scope of the Agreement ("Change Order"). A Change Order shall be issued
by Home Depot or Service Provider on behalf of Home Depot, which You may accept by signing. Upon Your signing of the
Change Order, it shall become part of this Agreement, subject to all of the terms of the Agreement. Change Order may also
result from Home Depot or Service Provider encountering conditions at the Work Area that impact, impede or otherwise
interfere with the performance of the Services, requiring an increase in cost, time, or both. Following the discovery of any
conditions that impact, impede or otherwise cause the Work Area not to have Safe Access, Home Depot may immediately
ask for a Change Order or discontinue the Services without further obligation to You. If You decline a Change Order request,
You or Home Depot may terminate this Agreement.
6. TITLE AND RISK OF LOSS: The title to and risk of loss for any materials or goods provided to You that originate from
Home Depot shall pass to You when paid in full by (1) You or (2) the Service Provider as part of the Services. Title to any
other materials or goods provided by Service Provider shall pass to You upon completion of the Services.
7. WARRANTY AND LIMITATION ON WARRANTIES: (a) Warranty: Unless otherwise stated in the Agreement, Home
Depot warrants for 1 year from the completion date that all Services shall (1) be performed with good workmanship and (ii)
conform to the requirements of the Agreement. During the warranty period and within a reasonable time after receiving
notice from You of a warranty claim, Home Depot may, at its sole option (i) correct or replace each Defect, or (ii) remove
each Defect and refund the full purchase price thereof to You; provided, however, that all warranties are voided if (1) anyone
other than Home Depot or Service Provider performs work upon or otherwise modifies any materials or Services provided
under this Agreement, or (2) You fail to pay Home Depot as provided in this Agreement.
The Home Depot - 2455 Paces Ferry Road, N.W. Bldg. B-3, Atlanta, Georgia 30339 - Customer Care: 1-800-466-3337
T&C (C E H 1OS) (15 DeC. 17) v 8.1.1
The Home Depot General Terms & Conditions
(b) Limitation on Warranties: THE WARRANTIES PROVIDED IN THIS AGREEMENT ARE STRICTLY LIMITED TO
THE FOREGOING EXPRESS WARRANTIES CONTAINED IN PARAGRAPH 7A, IN THE WARRANTY SECTION OF
THE AGREEMENT, IF ANY, OR IN THE STATE SUPPLEMENT, IF ANY. YOU ACKNOWLEDGE AND AGREE THAT
NO OTHER WARRANTIES ARE MADE OR GIVEN BY HOME DEPOT OR SERVICE PROVIDER, INCLUDING ANY
WARRANTY FOR FITNESS OF PURPOSE, WARRANTY OF MERCHANTABILITY, OR ANY OTHER ORAL, EXPRESS
OR IMPLIED WARRANTIES. HOME DEPOT'S EXPRESS WARRANTIES ARE VOIDED FOR ANY DEFECT CAUSED
BY ABUSE, MISUSE, NEGLECT, ACTS OF GOD, LACK OF PRESCRIBED OR STANDARD MAINTENANCE, OR
IMPROPER CARE/CLEANING. ANY MANUFACTURER'S WARRANTIES PROVIDED FOR GOODS, MATERIALS, OR
EQUIPMENT WILL BE PASSED THROUGH BY HOME DEPOT TO YOU, AND YOU AGREE TO LOOK SOLELY TO SUCH
MANUFACTURER FOR REMEDY OF ANY DEFECT IN SUCH GOODS, MATERIALS, AND EQUIPMENT. HOME DEPOT
MAY ASSIST YOU WITH WARRANTY CLAIMS AGAINST MANUFACTURERS.
B. TERMINATION: This Agreement may be terminated by Home Depot for its convenience, and by either party for cause
if the other party fails to correct a material breach within ten (10) days after receiving notice from the non -breaching party
identifying the breach. In the event Home Depot terminates this Agreement because You fail to provide Safe Access to
perform the Services, or if either party terminates the Agreement because You decline a Change Order request resulting
from unforeseen or hazardous conditions, then You shall pay Home Depot for Services provided through the date of
termination plus any costs or expenses incurred by Home Depot or Service Provider as a result of the termination.
9. CHOICE OF LAW: SEVERABILITY: This Agreement shall be governed by and interpreted in accordance with the laws
of the State where the Project is physically located.. The parties intend for the terms and conditions in the Agreement to be
complementary, consistent, and enforceable under applicable laws. In the event any term or condition in the Agreement
violates applicable law, such term or condition shall be severed from the Agreement, but only to the extent necessary to
avoid such violation, without invalidating any other terms and conditions of the Agreement.
10. ENTIRE AGREEMENT: This Agreement is the final, integrated, and exclusive expression of the parties' understanding,
which supersedes all prior offers, orders, understandings, representations, proposals, confirmations, and negotiations
between the parties, whether oral or written. No course of dealing, usage of trade, course of performance, course of conduct,
or any other evidence of additional or different terms shall be admissible to contradict or vary any term in the Agreement.
11. SECURITY INTERESTS: LIENS: If You make all payments as required under this Agreement, no security interest will be
placed against Your property by Horne Depot. If a security interest is placed on Your property, it creates a lien, mortgage, or
other claim against Your property to secure payment and may cause a loss of Your property if You fail to pay as requested.
After paying on any completed phase of the Services and before making any further payments, You should request from
Home Depot or Service Provider a signed, unconditional release from, or waiver of, any right to place any claim against Your
property applicable to the work then completed. You may ask an attorney about Your rights to discharge security interests.
12. RETURNS: Custom order merchandise (i.e., goods that are custom made, uniquely altered, colormatched, shaped,
sized, or otherwise uniquely designed or fitted to the requirements of a particular space) is non -returnable, and its purchase
price cannot be refunded unless Home Depot or Service Provider (1) incorrectly ordered item, or (2) damaged item beyond
repair. Special order merchandise may be returned, and a refund for all or part of the purchase price provided, in the
discretion of Home Depot. Please contact Your store for additional details concerning returns.
13. AGREEMENT/SERVICE ORDER COMMUNICATION PREFERENCES: You can visit www.homedepot.com > In -
Store Special Orders at any time to access Your account for the following: (1) Update Your Agreement/Service Order
Communication Preferences (email, text, Auto Call); (2) Contact Home Depot for order assistance; (3) View latest order
status; or (4) Take action to schedule pickup for Your Service Orders. To stop any of the following communications You
may visit www.homedepot.com > In -Store Special Orders to access Your account to update Your Agreement/Service Order
Communication Preferences, contact The Home Depot, and take action on orders. If You signed up to receive updates
about Your Agreement/Service Order(s) via: (a) Text Message Communications, You may receive multiple messages per
order (including current and future orders) via automated technology to the mobile phone number You provided. The total
number of messages received depends on the number of orders placed and order activity. Standard message and data
rates apply. Not all carriers covered. You can text STOP to 97710 to stop (You will be sent a confirmation message). Call
1-877-467-2581 or 1-800-466-3337 for help; (b) Electronic voice communications (Auto Call), You may receive multiple
pre-recorded phone calls per order (including current and future orders) via automated technology to the phone number
You provided. The total number of calls received depends on the number of orders placed and order activity. You can press
9 during a call to opt out or call 800-HOME-DEPOT for help; or (c) Email Communications, You may receive multiple
Emails per order (including current and future orders) via automated technology to the Email address You provided. The total
number of Emails received depends on the number of orders placed and order activity.
The Home Depot - 2455 Paces Ferry Road, N.W. Bldg. B-3, Atlanta, Georgia 30339 - Customer Care: 1-800-466-3337
v
T&C (C E H 10 S) (15 Dec. 17)
Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved.
Site Address:
Parcel ID:
Account 4:
Map ID:
Use Type:
Zoning:
City/County:
Ownership
Christopher Handy
Cheryl Handy
8650 Pine Martin Ln
Fort Pierce, FL 34947
Legal Description
TIMBERLAKE ESTATES LOT 36 (0.93 AC) (OR 3000-1129)
Current Values
Just/Market Value: $193,700
Assessed Value: $139,378
Exemptions: $50.000
Taxable Value: $89,378
Taxes for this parcel: SLC Tax Collector's Office 12
Download TRIM for this parcel: Download PDF
Property Identification
8650 PINE MARTIN LN
2302-601-0040-000-0
12829
23/02N
0100
RS-2
Saint Lucie County
Total Areas
Finished/Under Au (SF):
2,500
Gross Area (SF):
4,756
Land Size (acres):
0.93
Land Size (SF):
40,510.8
This information is believed to be correct at this time but it is subject to change and is not warranted.
0 Copyright 2018 Saint Lucie County Property Appraiser. All rights reserved.
HOME
c=uvtrcc
CtN4`%R MEASURE SHEET
lJob W: /- /r/0 6 ZIRRIn :3
Customer:
Instait: Seamless Aluminum 5" or 6" Guttef with Standard or Cbmmerchd Downspouts
• ` ( KETCH ENTIRE Roo
fi �►:%
x :r
•�' t
Key C
Install Gutter No Gutter _�.._ _ O Story Down Spouts 2 Shy Down Spouts
MEASUREMENTS AND SPECIFICATIONS
1. Remove Existing Gutter
Yes ❑ No ❑ L,ead Protection Panel Yea ❑ No ❑
2. Gutters - (Linear Feet)
3, Leaf Protection - (Unear Feet)
4. Total Feet of
Section A
Seetlan A
Total Feet DiS
S W x 13 a
Section B
Section B
D/S 13`)
Section C
Section C
Section D
Section D
Total Feet of 2 Story D1S
D1S x 23 Q
(Each DIS 23-)
Total Lin Ft.
Total Lin Ft.
Gutter Color
w 1.P or
DM Color
5. Roof Type:
Toe
go!nPo%Wpn ❑
s. other
Fascia Board ❑
Open Rafter Talcs ❑
Maul ❑
CO E.NTS
7.32-V VC.C.
Scanned with CamScanner
_
ga>"
`yam
o�
m
ca rn
3 c
O 5 ir
m Q
N 0 m
g' a
CDE�
000`ui
�Em
v—��,o
li
m �j O
o n.
LL X
N
tll
ON
O
O
!A
N
. IA
N
In
N
IA
N
to
J N
1n
N
10
J N
. IA
N
o
y U
J
ON
J
ON
J
ON
J
ON
ON
J
ON
ON
J
ON
Oa
0,
Oa
OG
Oa
Oa
Oa
0,
cc J
rU
~IchU
r-L)
r-lcnL)
-0
rU
rU
rU
—n
m H
a
C
a
C
o
C
a
c
a
C
a
C
a
C
v
C
Q
10 C—
2 m O
m
N
22
CA
(A
R
to
2
y
.. c
y
y
m
N
(A
�Y
YU
ado`
x
Z3V
L�V
0.
t�U
0.
:E�
0.L
3�Ya
3�Y
a0.
:E�Y
3a
!E�
3a
W
I!1
N
N
N
y
O V
D0
N
D �^
IElUOZIJOH
n
0
i0�!UOA
U011E00.1
o
IEIUOZIJOH
C
O
0
IEOIUOA
v
�
a
c
m
u1011ed
Z
JOIO0
{J8J 'S
j) 0dA.L
y
In
N
4i
C
E
C
0
N
O
C
146i8H
o
0
0
0
0
0
0
0
O
m
O
Ln
Ln
M
l(I
Ln
N
m
h
Ln
4lPIM
o
W
0
W
m
0
cc
m
0
(c
m
0
cc
m
0
co
m
0
rc
0
�c
toueix3
0
U
JOIJBIUI
d
N
N
O
c
O
O
cc
O
w
O
cc
O
I co
O
cc
O
00
78
U
m
x
O
x
D
x
D
A
=
O
=
D
x
x
O
C
3 }
z
z
z
z
z
z
z
z
T'8
N
c
3
U
o
x
x
x
o
o
A
=
H
x
W
c
O
LL
E
U
N
N
N
$
D
D
Q:
D
w
D
w
D
w
O
w
O
w
in
r
Q
LU
m
m
# W311
N
IA
a
C
W
f0 C1
c m
O '3
66
Z
U _O
O
O
m
H
a
a 5
y
w
O
c o
.� C
O
U)
Z
OU
— «
R G
= U
•3
J
a
a
U
W
m m
C H
CL
(A
l6
_CD
E
t6 ~
m
0
0.
'
°7 C.
m
R
c
c
c
>
ca
w
U
m
i
d
J
0
O
abed 6u!mollol a4l uo suoplpuo0 pue swJal leloadS I
a4l pue anoge suo!leo!lpeds qol o4l lie 411M OaJBe pue P9MGIA0J ane4 I
IIWJad Pue 6ulJaau!Bu3 : LDSIIN Ianal
:SNOI1Vd301SNOO 1V103dS
(480 J0 43J!g 'alluold al!4M-Aluo lAuln) IeualeW pJeoglea
:Mopu!M uap,e0
. (ON Jo saA) looa lonJlsuo
lelJalew llllos 10 Joloo '1!1los of Pop 1
(sa4ou!)1!llos of mopu!m to do
0uw60 JO 'HS 'HO) adA.L JaJlueld de
(Sh 10 Od aIBuV )oaloJd Ae
(wo Jo 4oJ!B-Aluo {J(uln) {elJalew pJeoglea
:MOpu!m MOB Jo Aug
adA_L BulseO Joualu
Jo{o0 deJ
9Z'Z dOl
PJepuelS :VedSSeI0
L
Z
dOl
L
Z
d0
I'l
090' d
L
00,99
00,9E
I
1
0008
HO
N
HO
Isl
3NIC
9
'1001
'8114M 'Ol
SZ'Z dO
PJepuelS :40edssel
vv
00'9Z
00'81
1
0008
H❑
N
HQ
IS[
HIV13
S
'1001
01!4M '01
SZ'Z d0l
PJepuelS :43udsse{
L
00'6
00'81
1
1
0008
110
N
IIO
Isl
H011
V
'1001.
'0114M 'Ol
SZ'Z d01
PJePueIS :Jlaedssel
L9
00'6C
00,9z
1
0008
HO
N
HO
isl
H311
£
'1001
'0114M 'Ol
SZ'Z dol
PJepuelS :pedssel
L9
00'6£
00'8Z
1
1
0008
HO
N
HC1
Isl
HDIIN
Z
1001
'all4M '01
SZ'Z d3l
PJepuelS :>Ioedssel
66
oo*c9
00,9E
I
1
0008
HO
N
HO
Isl
v4vd
l
I lools
almm 'Ol
SZ'Z d3l
PJepuelS :Jloedssel
66
00,E9
00'91
1
1
0008
HC1
N
HO
Isl
WV
0
'1001
01!4M 'Ol
SZ'Z dDl
PJepuelS :40edssel
L
00'ss
00,9E
I
1
0009
H
N
HO
lsl
038VN
'1001
al!4M 'Ol
x
x
C
0
cn —1
c
x
g
apo salia
O S
a o a J(
P O I IS
(NIA)
a s
P O
100 Id
woo a
=I
o
sdeJM
a{JS1g
6ulleJado = »X«
c
o-
o
m
cam
c
Jo keuollels = »S»
IInW
w
asn siOOP Jod
sueeias
ap
swelll oslW
MmRWH
sselO
S Jo a 'l asn
.lud L 'sluws0
sJeq to #
sJeq 10 #
Buluado 4Bnoa
JoloO
ualeool
smog 'SAUS
146ia of Ilal
'ap!slno woJd
suo!ldO Jogel
suo1ldo IonpoJd
sppO
sluauJeJnseeW
MopulM 6ullslx3
suolleaol 96u!H
Mopu!M MON
9loz/6z/90 :a)efl 4sleM u!naH :Iuullnsuoo E988199-L '# 4or AONVH 1AdBH0 'jawo)s! o
E 10 z :)aa4s £989199-L :# jaays *oadS - 133HS NOI1d013103dS MOONIM
o6ed 6ulmollo; eql uo suolllpuo0 pue sw,al le!oadS
041 pue aAOge suo!leol;loads qol e4l Ile 41!m oej6e pue pomolAO, ene4 I
I!w,ad pue BuPaau16u3 ; LOSIW lanai qo
:SN0IIVb341SN001V103dS
(IieO 10 43ng 'alluOld e114M•Aluo IAuIA) leljoleW pjeoglea
:mopu,M uapjeg
(ON jo saA);OOd Ionjlsuo
lepalew l!;;os 10 J0103 -111;os Ol pall I
(saLl-!)1910s 01 mOpu!m 10 do
4uws0 jo 'HS '1i(]) adAl janueld Ae
(9V j0 OC) a16uV loalad Ae
(jeo jo 4ojlg-Aluo IAuIA) Iepa;ew pje0glea
:mopulm moe jo Aea
adAl 6ulse0 jouelu
jolo0 dvjAA
SZ Z d3l
Pjepue)S :n3edssel
I
Z
dOl
L
Z
dOl
01'
J8J ' j
66
OO E9
00*9E
000e
HG
tic)
Isl
AdI.N
£Z
,100IS
al!4M 'Ul
SCZ d3i
pjepuelS ;10edsselD
l
Z
dOl
l
Z
dU
I'l
080
66
OO C9
009E
0008
1W
N
HU
Isl
A211N3
Z
,100IS
al!4M (J1
SZ-Z dO
Pjepue)S :)IOedssel
dU
1,
dO
1'
080
66
00 C9
00,9E
000
tiu
N
HO
IsL
AL11N
L
,1001E
all4M '01
SZ'Z dO
pjepuelS :10edssulD
t
1,
d01
I
t
d01
3
1'l
080 'J
LU
00E
00*t1z
0008
lic
NH
Isl
3NIC
OZ
1001E
04M 'Ol
SZ-Z d3l
pjepuelS ;joedsselo
I
Z
d01
i
I
Z
d01
I
I'l
080 ' j
6
00 E
00,9E
000
H
N
H
I
lsl
3NIC
I
6
1001
'0114M 'GIS
—
9Z'Z d3l
pjepuelS ;joedssel
l
Z
dol.
l
Z
d01
I%
gag,
6
1
00,E9
00'9
1
1
000
H
N
HC
i
ISI
3NI
8
1001
'8414M 'CIIS
SZ'Z d3l
'1001
PjepuelS :43edsselO
'al!4M 'GIs
I
l
d01
I
I
d01
0
1'1
J8J' 3
L
00,E
00'VZ
1
000
HO
N
HO
J
1st
3NI
L
6ullejedo = X.
x
c
<
W
r-
3:0
o
7
<
r-
�Q§
p
U
0
n
c
Cl)
T
e_
:
?
n
7
T
a,
0
5
�
apo0 saljas
apo0 elAIS
(WA)
sdejM
OPOO
aIAIS
JOOld
wood
m
#
j0 Ajeuollels = .S«
IInW
to
�
o�
3
asn sjoop 10j
ep00
swag oslW
suaajos
ajempjeH
sse10
S jo H '1 osn
'lud I 'sluwsO
sjeq to r
sjeq 10 x
6ulued0 46noU
jolo0
U01Ie0O1
smog 'sAeg
1461H 01 1181
'aplsino wojd
suolld0 joge-I
suoµd0 lonPajd
spu0
sluawajnseey4
MOPu!M Bullslx3
suolleool o6u1H
mopulM maN
SLOZI6Z190 'oleo
4sleM u!Aa)l :luellnSU00
£989199-L :# qor
AONVH 1A83HO:jaul0lsno
E 10 E :084S C988199- L :# lea4S 'oadS - 133HS NOI1d013103dS MOONIM
Florida Building Code Online
Page 1 of 3
NEW
Business & Professional Regulation
BCIS Home p Log In I User Registration i Hot Topics P Submit Surcharge ` Slats & Facts Publications FBC Staff BCIS Site Map Links Search
ba
I
Product Approval
pr
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL5419-R15
Application Type
Revision
Code Version
2017
Application Status
Approved
Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
❑
Product Manufacturer
Simonton Windows
Address/Phone/Email
3948 Townsfair Way
Columbus, OH 43219
(614) 532-3596
luanne.harris@simonton.com
Authorized Signature
Luanne Harris
luanne.harris@simonton.com
Technical Representative
Luanne Harris
Address/Phone/Email
3948 Townsfair Way
Suite 200
Columbus, OH 43219
(614) 532-3596
luanne.harris@simonton.com
Quality Assurance Representative
AAMA
Address/Phone/Email
1827 Walden Office Square
Suite 550
Schaumburg, IL60173
(847) 303-5664
webmaster@aamanet.org
Category
Windows
Subcategory
Double Hung
Compliance Method
Certification Mark or Listing
Certification Agency
American Architectural Manufacturers Association
Validated By
American Architectural Manufacturers Association
Referenced Standard and Year (of Standard) Standard
Year
AAMA 450
2010
AAMA 506
2011
AAMA/WDMA/CSA 101/I.S.2/A440
2008
ASTM E 1886
2005
ASTM E 1996
2005
ASTM E 1996
2009
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL5419 R15 Equiv FL5419 Eguivalencv.odf
https://floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgtHJPwMo6eHrjCHN... 1 / 12/2018
Florida Building Code Online
Page 2 of 3
Product Approval Method Method 1 Option A
Date Submitted 11/07/2017
Date Validated 11/17/2017
Date Pending FBC Approval
Date Approved 11/26/2017
Summary of Products
FL #
Model, Number or Name
Description
5419.1
07-09 / 07-10 / 07-20 (Retrofit
Storm Breaker Plus 300VL, 8000, PerfeXion Impact, Impact
Installation)
Vinyl Double Hung
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL5419 R15 C CAC 07-09 07-20 DH 53 x 76 R PG50
Impact.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
FL5419 R15 C CAC 07-09 07-20 DH Impact 37x76 R
PG65.pdf
Design Pressure: N/A
Other: 53 x 76 (+/-55 PSF), 53 x 76 (+/-50 PSF), 37 x 84
FL5419 R15 C CAC 07-09 07-20 DH Impact 37x84 R
PG60.1)df
(+/-60 PSF), 37 x 76 (+/-65 PSF) - Missile Impact Rating: D
FL5419 R15 C CAC 07-09 07-20 DH Impact 53x76 R
PG55.pdf
FL5419 R15 C CAC 07-09 DH TemvGI Impact 37x76 R
PG65.pdf
FL5419 R15 C CAC 07-09-10-20 and 08-09-10-20
Waiver.pdf
Quality Assurance Contract Expiration Date
07/28/2019
Installation Instructions
FL5419 R15 II IN0364-R10 07-09 07-10 07-20 Impact
DH.pdf
Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
FL5419 R15 AE EvalReport-IN0364-R10.odf
Created by Independent Third Party: Yes
5419.2
07-20 (Nailing Fin Installation)
Storm Breaker Plus 300VL, 8000, PerfeXion Impact Vinyl
Double Hung Twin
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL5419 R15 C CAC FL5419 C CAC 07-20 DH Twin Impact
73 x 74 R50 .pdf
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Quality Assurance Contract Expiration Date
Design Pressure: +50/-50
03/24/2020
Other: 73 x 74 - Missile Impact Rating: D
Installation Instructions
FL5419 R15 11 1 N0523 SP 07-20 DH Twin 2X.odf
Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
5419.3
07-20 (Nailing Fin Installation)
Storm Breaker Plus 300VL, 8000, PerfeXion Impact Vinyl
Double Hung
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL5419 R15 C CAC 07-20 DH Impact R PG50 53x76.pdf
Quality Assurance Contract Expiration Date
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
07/28/2019
Design Pressure: +50/-50
Installation Instructions
Other: 53 x 76 - Missile Impact Rating: D
FL5419 R15 II IN0589 SP 07-20 DH 2X.pdf
Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
5419.4
42-19
ProFinish Brickmould 600 with Safe Point Storm Vinyl Double
Hung
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL5419 R15 C CAC 42-19 DH Impact Annealed 36x63 R50
(ext.).odf
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
FL5419 R15 C CAC 42-19 DH Impact Annealed 36x74 R50
(ext.).pdf
Design Pressure: +50/-50
https:Hfloridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgtHJPwMo6eHrjCHN... 1 / 12/2018
MODEL DESIGNATION: Simonton Double Hung Series 07-09 / 07-10 / 07-20 Vinyl Impact Window
MAXIMUM OVERALL NOMINAL SIZE: See Size Chart
DESIGN PRESSURE RATING: See Size Chart
USABLE CONFIGURATIONS: X
X
GENERAL DESCRIPTION: The head, sill, and side jambs are extruded PVC. The wall thickness
through which the anchor screw penetrates is a minimum of 0.070".
�� "W" MAX. OVERALL FRAME WIDTH
,2� 11-7—'
11/3/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
TURNER ENGINEERING &
CONSULTING, INC.
(COA # 29779)
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
REV.
REVISIONS:
REVISED BY:
DATE:
6
UDPATED SIZES PER NEW TESTING.
T.D.D.
12/17/13
7
UDPATED FOR MULTIPLE SUBSTRATE TYPES
L.A.T.
9/15/14
8
ADDED 53X76 SIZE DP50
L.A.T.
6/30/15
9
ADDED TEST REPORT NUMBER TO NOTE 15.
LMH
4/18/17
10
REMOVED PRE —DRILLED HOLES.
LMH
10/27/17
MIN. EMBED.,
SUBSTRATE
SEE TBL 1,
MIN. EDGE DIST.,
INSTALLATION
_�
BY OTHERS
SHT 2
6" - SEE TBL 1, SHT 2
C°
FASTENER.
o J N
Z m
SEE TABLE 1,
m
� =
INSTALLATION
SILICONE CAULK
SHEET 2
w w cn
FASTENER
1/4" MAX. SHIM
I
SEE TABLE 1,
SUBSTRATE
SHEET 2
INTERIOR
BY OTHERS
w - - N
�o
woLnm=
a
o
}
SILICONE CAULK
SILICONE CAULK
V,)
/
o
0
1/4" MAX. SHIM
El
INTERIOR
SILICONE CAULK
SIZE CHART
OVERALL SIZE
DP RATING
WIDTH
"W„
HEIGHT
„Id„
53"
76"
±50 PSF
53"
76"
±55 PSF
37"
1 84"
±60 PSF
37"
1 76"
±65 PSF
SILICONE CAULK
SUBSTRATE
BY OTHER
HEAD
1
SILL
1
DISCLOSURE STATEMENT
This document is the property of Simonton Windows, which
retains all proprietary and other rights to its subject matter.
This document is provided to the recipient on the expressed
:ondition that it is not to be disclosed, reproduced in whole o
part, nor used in conjunction with the design, manufacture or
repair of goods for anyone other than Simonton Windows
without its consent. This restriction does not limit the
recipient's rights to utilize information contained in this
document which is properly obtained from another source.
N.
MAX. SHIM
;ONE CAULK
�3� JAMB
1
T --t
0
.500"
GLASS BITE
O
° 0 Q
Q
GLAZING COMPOUND
(PECORA 896—HIS)
1/8" ANNEALED
0.105 PVB (EASTMAN/
SOLUTIA)
1/8" ANNEALED
___— AIR SPACE
1/8" ANNEALED
SPACER
1" INSULATED ANNEALED IMPACT GLASS
WITH 0.105" PVB INTERLAYER
Dimensional Tolerances SIMON TON
DRAWN BY: DATE:
kS NOTE Unless Otherwise Specified0 w i N D a w s
P T.D.D. 11 /13
1 Cochrane Avenue CHECKED BY: DATE:
Pennsbom, VW 26415
VOLUME: Decimals Angles SCALE: SHEET: APPRV'D BY: DATE:
PERIMETER: A t .03 FIT 1 of 2
XX t .01 0' 30 min. SERIES:
r. XXX t .005 07-09 / 07-10 / 07-20 IMPACT DOUBLE HUNG
ELEVATION, INSTALLATION DETAILS, STND. GLAZING DETAIL
NOTES:
1. This installation has been evaluated for use in locations adhering to the Texas & Florida Building Codes and where pressure requirements
as determined by ASCE 7 Minimum Design Loads for Buildings and Other Structures do not exceed the design pressure ratings herein, for
use outside the H.V.H.Z.
2. All interior and exterior perimeter surfaces of the window must be caulked.
3. Anchor type, size, spacing, and embedment shall be as specified in these drawings.
4. Anchor embedment to substrate shall be beyond wall dressing or stucco. For concrete/CMU openings embedment shall be beyond wood
bucks, if used, and into substrate. Installations to solid concrete or grout -filled CMU may include but do not require 1x wood bucks between
product and substrate. Installations to hollow CMU require the use of 1x bucks between product and substrate.
5. Wood or masonry openings, bucks, and buck fasteners, by others, shall be properly designed and installed to transfer wind loads to the
structure. Substrates shall meet the minimum strength requirements as shown in Table 1, this sheet. Concrete or masonry substrates
shall not be cracked.
6. The responsibility for selection of Simonton products to meet any applicable local laws, building codes, ordinances, or other safety
requirements rests solely with the architect, building owner, or contractor.
7. Shims are required where gaps of greater than 1/16" exist between opening and frame. Max. shim stack is 1/4". Shims shall be
load -bearing and capable of transferring loads to the substrate.
8. When used in areas requiring impact protection, this product DOES NOT REQUIRE the use of approved impact resistant shutters or other
external protection.
9. Sealing and flashing by others should be applied using the ASTM E 2112 methodology appropriate for the opening into which the door is
being installed. Overall water penetration resistance of the installed product is the responsibility of others.
10. Glazing shall comply with ASTM E 1300
11. For installation to metal substrates, anchors shall be long enough to be fully threaded through the metal thickness with an additional 3/16"
min. of threads beyond.
12. A minimum center -to -center spacing of 1-1/4" shall be maintained between all Elco Ultracons in any direction.
13. All fasteners penetrating into pressure treated wood shall be capable of preventing corrosion due to reaction with pressure treatment
chemicals. Any dissimilar materials that come into contact shall be protected to prevent reactions in accordance with code requirements.
14. A wind load duration factor Cd = 1.6 was used for the analysis of wood screws only.
15. Windows shall be constructed as specified in test reports A8088.01-501-47-r0, A9235.01-501-47-r0, A9261.01-501-47-r1,
C7745.01-109-47-r0, D0296.01-501-47-r0, D0962.01-501-47-r0, D0963.01-501-47-r0, D0964.01-501-47-r0, D8119.01-109-47-r0,
D0295.01-501-47-r0, D8118.01-109-47-r0, D8120.01-109-47 and D0965.01-501-47-r0 by Architectural Testing, Inc and T259-10 by
Farabaugh Engineering & Testing Inc.
16. Use 100% pure silicone caulk compliant with AAMA 808 Section 5 - Sealant Specifications for use with Architectural Fenestration
Products. Make sure surfaces are completely free from all old caulk, damaged wood, wood fibers, grease, oil dirt, rust, mold or similar
contaminants. Vacuum and clean opening surfaces completely. A fully primed surface is recommended, but not required. Cleaning of all
surfaces should be done the same day of which the silicone caulk is to applied. For more details visit Simonton.com.
17.Caulk application: recommended air and surface temperatures at the time of application are to be between 40 and 90 degrees F. Insure all
contact surfaces are clean and dry including the new window(s). Use a backer rod on all joints >3/4" deep and/or wider than 1/4".
Finished caulk joint should be a minimum of 3/8" deep and make full contact with both the new window and structural opening surfaces.
Silicone caulk should be forced into joint or compressed to assure full contact on both surfaces and to expel any air pockets.
TABLE 1: INSTALLATION FASTENERS TABLE
ID
SUBSTRATE TYPE
ANCHOR TYPE
MIN. EMBED
MIN. EDGE DIST.
A
CONCRETE (2.85 KSI MIN.)
3/16" ELCO ULTRACON
1 "
1 "
B
HOLLOW OR GROUT -FILLED CMU
3/16" ELCO ULTRACON
1 -1 /4"
2 1 /2"
ASTM C90
C
2X MIN. SOUTHERN PINE WOOD
3/16" ELCO ULTRACON
1 -3/8"
3/4"
G=0.55
D
2X MIN. SOUTHERN PINE WOOD
#10 WOOD SCREW
1-3/8"
3/4"
G=0.55
E
16 GAUGE (0.060") MIN. STEEL
10-16 ITW TEKS
SEE NOTE 11
1 /2"
STUD 33KS1 YIELD MIN.
SELF -DRILLING SCREW
F
1/8" ALUM. 6063-T5 MIN. OR
#10 GRADE 5 SELF -TAPPING/
SEE NOTE 11
1 /2"
1/8" STEEL 36 KSI MIN.
DRILLING SCREW
DISCLOSURE STATEMENT
This document is the property of Simonton Windows, which
retains all proprietary and other rights to its subject matter.
This document is provided to the recipient on the expressed
:ondition that it is not to be disclosed, reproduced in whole o
part, nor used in conjunction with the design, manufacture or
repair of goods for anyone other than Simonton Windows
without its consent. This restriction does not limit the
recipient's rights to utilize information contained in this
document which is properly obtained from another source.
,lz;;_",
11/3/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
TURNER ENGINEERING &
CONSULTING, INC.
(COA # 29779)
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
0
500"
GLASS BITE
O
REV.
REVISIONS:
REVISED BY-
DATE:
6
UDPATED SIZES PER NEW TESTING.
T.D.D.
12/17/13
7
UDPATED FOR MULTIPLE SUBSTRATE TYPES
L.A.T.
9/15/14
8
ADDED 53X76 SIZE DP50
L.A.T.
6/30/15
9
1 ADDED TEST REPORT NUMBER TO NOTE 15.
LMH
4/18/17
10
REMOVED PRE —DRILLED HOLES. ADDED NOTE
1A J4 17 — AAAAA Ann
LMH
102717
/ /
SPACER
GLAZING COMPOUND
(PECORA 896—HIS)
1/8" ANNEALED
0.105 PVB (EASTMAN/SOLUTIA)
1/8" ANNEALED
_— AIR SPACE
1/8" TEMPERED
1" INSULATED TEMPERED/ ANNEALED IMPACT GLASS
WITH 0.105" PVB INTERLAYER
37" X 76" AND 53" X 76" DOUBLE HUNG (OPTIONAL)
0
500"
GLASS BITE
O
IDD Q
Q
GLAZING COMPOUND
(PECORA 896—HIS)
1/8" ANNEALED
0.090 PVB (EASTMAN/SOLUTIA)
1/8" ANNEALED
AIR SPACE
1/8" TEMPERED
SPACER
1" INSULATED TEMPERED ANNEALED IMPACT GLASS
WITH 0.090" PVB INTERLAYER
37" X 84" DOUBLE HUNG (OPTIONAL;
Dimensional Tolerances
Unless Otherwise Specified
Decimals Angles
.Xt.03
.XX t .01 0' 30 min.
XXX t .005
0 SIMONTON° �,8�. INo3s4
W i N D o W s DRAWN BY: JDATE
1 Cochrane Avenue T.D.D. 1 11,
Pennsboro, WV 26415 CHECKED BY: DATE
FIT 1 2 of 2
07-09 / 07-10 / 07-20 IMPACT DOUBLE HUNG
ANCHOR TABLE, & OPTIONAL GLAZING DETAILS
Florida Building Code Online
Page 1 of 2
NEW
Business & Professional Regulation
BCIS Home p Log In I User Registration i Hot Topics P Submit Surcharge ` Slats & Facts Publications FBC Staff BCIS Site Map Links Search
ba
I
Product Approval
pr
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL15534-R4
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived ❑
Product Manufacturer Simonton Windows
Address/Phone/Email 3948 Townsfair Way
Columbus, OH 43219
(614) 532-3596
luanne.harris@simonton.com
Authorized Signature Luanne Harris
luanne.harris@simonton.com
Technical Representative Luanne Harris
Address/Phone/Email 3948 Townsfair Way
Suite 200
Columbus, OH 43219
(614) 532-3596
luanne.harris@simonton.com
Quality Assurance Representative AAMA
Address/Phone/Email 1827 Walden Office Square
Suite 550
Schaumburg, IL60173
(847) 303-5664
webmaster@aamanet.org
Category Windows
Subcategory Mullions
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Lucas A. Turner
the Evaluation Report
Florida License PE-58201
Quality Assurance Entity Architectural Testing, Inc.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Scott Wolters, PE
,,/ Validation Checklist - Hardcopy Received
Certificate of Independence FL15534 R4 COI EvalReport-RM0051r7.1)df
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Standard
TAS 201 / 202 / 203
Florida Licensed Professional Engineer or Architect
FL15534 R4 Eauiv SimEx-PVC- Equivalency.odf
Year
1994
https : //floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgvKmQdIOUtQtoIOP 1... 1 /3 0/2018
Florida Building Code Online
Page 2 of 2
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
of Products
Method 1 Option D
10/12/2017
10/19/2017
10/22/2017
12/12/2017
FL # Model, Number or Name Description
15534.1 20634 Aluminum with VPI-436 Storm breaker Plus 300VL Vinyl Mullions with Medium
Vinyl Mullion Cover Aluminum Reinforcement (HVHZ)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL15534 R4 11 RM0052HVHZr4.Ddf
Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner PE # 58201
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: +50/-50 Evaluation Reports
Other: Missile Impact Rating: Large FL15534 R4 AE EvalReport-RM0052HVHZr4.Ddf
Created by Independent Third Party: Yes
15534.2
716991MAluminum with VPI-354
ullion Cover
Storm breaker Plus 300VL Vinyl Mullions with Large
Aluminum Reinforcement (HVHZ)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL15534 R4 11 RM0051r7.Ddf
Approved for use outside HVHZ: Yes
Verified By: Lucas A. Turner PE # 58201
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Design pressure ratings vary by unit and mullion
FL15534 R4 AE EvalReport-RM0051r7.Ddf
size. Missile Impact Rating: Large
Created by Independent Third Party: Yes
15534.3
20634 Aluminum with VPI-436
Vinyl Mullion Cover
Stormbreaker Plus 300VL Vinyl Mullions with Medium
Aluminum Reinforcement (Non-HVHZ)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL15534 R4 11 RM0052r5.Ddf
Approved for use outside HVHZ: Yes
Verified By: Lucas A. Turner PE # 58201
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Design pressure ratings vary by unit and mullion
FL15534 R4 AE EvalReoort-RM0052r5.pdf
size. Missile Impact Rating: Large
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. ' Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The smalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
Credit Card
Safe
https : //floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgvKmQdIOUtQtoIOP 1... 1 /3 0/2018
SIMONTON'
W I N D O W S
1 COCHRANE AVE. PENNSBORO, WV 26415 PH.
800-426-2249
STORMBREAKER PLUS 300VL SERIES
MULLIONS WITH MEDIUM ALUMINUM
REINFORCEMENT - NON-HVHZ
FOR IMPACT RESISTANT ASSEMBLIES
GENERAL NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED
TO COMPLY WITH THE 6TH EDITION (2017) FLORIDA BUILDING CODE
REQUIREMENTS EXCLUDING HVHZ.
2. THIS MULLION IS ONLY VALID WHEN USED IN CONJUNCTION WITH
APPLICABLE SIMONTON WINDOW SYSTEMS.
3. ALL WINDOWS USED WITH THIS MULLION SHALL BE QUALIFIED
UNDER SEPARATE APPROVAL. ALL GLAZING PRODUCTS USED WITH
THESE MULLIONS MUST MEET THE APPLICABLE FLORIDA BUILDING
CODE REQUIREMENTS.
4. ADEQUACY OF EXISTING STRUCTURAL CONCRETE/MASONRY, 2X
AND STEEL STUD FRAMING AS A MAIN WIND FORCE RESISTING
SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED
PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF
THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT
INSTALLATION.
5. 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO
PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK
DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE
ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT
INSTALLATION.
6. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC
AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE.
IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE
REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR
ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE
WITH THIS DOCUMENT.
7. THIS MULLION SYSTEM IS SUITABLE FOR ASSEMBLY OF IMPACT
RESISTANT PRODUCTS AND DOES NOT REQUIRE AN EXTERNAL
IMPACT PROTECTIVE DEVICE IN WINDBORNE DEBRIS REGIONS.
PARTS LIST
NUMBER
DESCRIPTION
PART NO
MATERIAL
1
MEDIUM MULLION COVER
VPI-436
PVC
2
MEDIUM MULLION REINFORCEMENT
20634
6063-T6
3
BASE PLATE
STEEL
4
MULLION L-BRACKET
ISTAINLESS STEEL
TABLE OF CONTENTS
PAGE NO
DESCRIPTION
1
GENERAL NOTES, PARTS LIST AND CROSS SECTIONS
2
ELEVATION AND DESIGN PRESSURE CHARTS
3
MULLION DETAILS & SILL CROSS SECTIONS
00
M
3.439" 0D
0 2.863"
� M
N 1.658" tO
o 0
o J
d M
O
I
0.529" — 0.446" — 0.289"
1.293"
0.235
RETROFIT FRAME MULLION
(1� MEDIUM VINYL MULLION COVER #VPI - 436 Q MEDIUM MULLION REINFORCEMENT #20634
EXTRUDED VINYL .070" MIN. ALUMINUM 6063-T6
#10 X 1 1 /8" SELI
TAPPING SCREWS SPACE[
PER APPLICABLE WINDOV
PRODUCT APPROVAI
AVER
#10 X 1 1 /8" SELF
TAPPING SCREWS SPACED
PER APPLICABLE WINDOW
PRODUCT APPROVAL
#10 X 1 1 /8" SELF
TAPPING SCREWS SPACED
v PER APPLICABLE WINDOW
REINFORCEMENT PRODUCT APPROVAL
DOUBLE HUNG HORIZONTAL CROSS SECTION
COVER
#10 X 1 1 /8" SELF
TAPPING SCREWS SPACED
PER APPLICABLE WINDOW
PRODUCT APPROVAL
MULLION REINFORCEMENT
PICTURE (FIXED) HORIZONTAL CROSS SECTION
SIMONTON'
W I N D O W S
COCHRANE AVE. PENNSBORO, WV 26415 PH.
800-426-2249
STORMBREAKER PLUS 300VL SERIES
MULLIONS WITH MEDIUM ALUMINUM
REINFORCEMENT — NON—HVHZ
FOR IMPACT RESISTANT ASSEMBLIES
105" MAX. OVERALL WIDTH
SEE CHART FOR SEE CHART FOR
SINGLE UNIT WIDTH SINGLE UNIT WIDTH
z
0
J
D
M
x
co
r-
NOTE:
The pressure chart shows the design pressures for
the selected mullion span and panel width for
achieving bending capacity, deflection and
concentrated load limits specified in the Florida
Building Code, 6th Edition (2017).
Adhere to fastening instructions provided in this
document to achieve the tabulated design
pressures.
Multiple mulled conditions are acceptable as long
as load width is not exceeded.
DESIGN PRESSURE CHART FOR MULLING
UNITS IN PSF, MULLION #20634
Individual Unit Width
24
28
30
32
34
36
37
40
42
45
48
50
53
26
50
50
50
50
50
50
50
50
50
50
50
50
50
36
50
50
50
50
50
50
50
50
50
50
50
50
50
42
50
50
50
50
50
50
50
50
50
50
50
50
50
52
50
50
50
50
50
50
50
50
50
50
50
50
50
56
50
50
50
50
50
50
50
50
50
50
50
50
50
58
50
50
50
50
50
50
50
50
50
50
50
50
50
19
60
50
50
50
50
50
50
50
50
50
45
45
45
45
y
62
50
50
50
50
50
50
45
45
45
40
40
40
40
a
63
50
50
50
50
50
45
45
40
40
40
40
35
35
65
50
50
50
45
45
40
40
40
35
35
35
35
30
67
50
45
45
40
40
35
35
35
35
30
30
30
30
68
50
45
40
40
35
35
35
30
30
30
30
30
25
70
45
40
35
35
35
30
30
30
30
25
25
25
25
71
45
40
35
35
30
30
30
30
25
25
25
25
25
72
40
35
35
30
30
30
30
25
25
25
25
20
20
74
40
35
30
30
25
25
25
25
25
20
20
20
20
76
35
30
30
25
25
25
25
20
20
20
20
20
20
SIIv ONT®AT
W I N D O W S
COCHRANE AVE. PENNSBORO, WV 26415 PH.
800-426-2249
STORMBREAKER PLUS 300VL SERIES
MULLIONS WITH MEDIUM ALUMINUM
REINFORCEMENT - NON-HVHZ
FOR IMPACT RESISTANT ASSEMBLIES
6.02"
0.63" -
0.63"
0
N
0 0
0.75"
FOUR (4) 0.2500
HOLES 075"
M REINFORCEMENT BASE PLATE DETAIL
.060" MIN. STEEL
TWO (2) 0.2590 HOLES
150"
0
A) MULLION L—BRACKET
.076" MIN. STAINLESS STEEL
ALUMINUM P
REINFORCEMEI`
) BASE PL
11) LARGE
MULLION COVER
10 LARGE
MULLION COVER
ANCHOR NOTES:
1) To achieve the required design pressures,
adhere to the fastener requirements below.
2) INSTALLATION TO WOOD (G=0.42 MIN):
Four (4) #10 wood screws for each base plate
with min. 1-1/2" embedment and min. 7/8" wood
edge distance.
3) INSTALLATION TO CONCRETE/MASONRY:
Two (2) screws for each base plate in outermost
holes. In grout —filled CMU block (ASTM C-90
Compliant) use 1/4" Elco Ultracons with 1 3/8"
min. embed. to block and 1" min. edge dist.
with min. 1-1/4" embedment. In solid concrete
(2.85 ksi min.) use 3/16" ITW Tapcons or 1/4"
Elco Ultracons with 1 3/4" min. embed to
concrete, and 1 1/8" min. edge dist.
® MULLION
L—BRACKET
® MULLION
L—BRACKET
DETAIL A
x
d d
n
•
'
VERTICAL SECTION @ SILL
MASONRY APPLICATION
;SUBSTRATES BY OTHERS)
x
VERTICAL SECTION @ SILL
WOOD APPLICATION
(SUBSTRATES BY OTHERS)
EXTRUDED VINYL
ULLION COVER
D L—BRACKET 11) ALUMINUM
MULL
REINFORCEM
SEE NOTES BELOW AND
MANUFACTURER'S
ATTACHMENT INSTRUCTIONS
FOR ATTACHING REINFORCE[
MULLIONS TO WINDOW UNITE
BASE PLATE
TWO CONC/MASONRY ANCHORS,
SEE ANCHOR NOTE 3
BASE PLATE
EMBEDMENT,
SEE NOTE 3
FOUR #10 SCREWS
1.5" MIN.
EMBEDMENT
(3BASE PLATE
SEE NOTES BELOW M
MANUFACTURER'S ATI11. .—, ,
INSTRUCTIONS FOR ATTACHING
REINFORCED MULLIONS TO
WINDOW UNITS
TABLE 1 (MULLION ATTACHING HARDWARE)
RIVET
.25 DIA. STEEL RIVET WITH A GRIP LENGTH OF .50 MAX.
BARREL NUT
1 #10-24 OR 10-32 STAINLESS STEEL BARREL NUT,
.250 O.D. .25" LG WITH .125 MIN ENGAGEMENT
1T EXTRUDED VINYL
ION COVER
L—BRACKET
—BRACKET IS ATTACHED
0 VINYL MULL COVER &
ULL REINFORCEMENT
SING TWO (2) RIVETS
R BARREL NUTS (305
B MAX SHEAR) 2 ON
ACH L—BRACKET REFER
0 TABLE 1
AK—WIK SPACER 1" X
/2" X 1/4" TH K. MAX.
4) REQ. (2) AT TOP
,ND (2) AT BOTTOM
ASSEMBLED MULL AND ATTACHMENT VIEW
4+.u"� �a5•arrr
a
6 4t
STA"E OF t