Loading...
HomeMy WebLinkAboutProduct Approval - fixed Florida Building Code Online f n Page I of 4 &i SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FDC Staff BCIS Site Map Links Search di Product Approval db re 00to USER:Public User Produc!Approval fl-u>Application Detail FL# 1-15768-114 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Soft-Lite LLC Address/Phone/Email 10250 Philipp Parkway Streetsboro,01-144241 (330)528-1136 PLangan@soft (:-lite.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Fixed Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity Farabaugh Engineering and Testing,Inc Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan 3.King,P.E. -.1 Validation Checklist-Hardcopy Received Certificate of Independence 1:115768 R4 C01 (a)Certificate of Independence.pdf Referenced Standard and Year(of Standard) Standard YSK AAMA/W DMA/CSA 101/I.S.2/A440 2008 AAMA/WDMA/CSA 101/I.S.2/A440 2011 ASTM E 1886 2005 ASTM E 1996 2006 ASTM E1300 2004 ASTM E1996 2009 TAS 201,202,203 1994 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/pr_appjtl.aspx?param=wGEVXQwtDqt3c I SAInEOW... 1/3/2018 Florida Building Code Online Page 2 of 4 Product Approval Method Method 1 Option D Date Submitted 10/07/2017 Date Validated 10/10/2017 Date Pending FBC Approval 10/15/2017 Date Approved 12/12/2017 Summary of Products FL# Model,Number or Name Description 15768.1 a."CPWL"Casement Picture Extruded PVC Low Profile Fixed Casement Picture Window- Window Low Profile (0 Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15768 R4 II (a)Inst 15768.1.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15768.1 for Design Pressure Ratings,any FL15768 R4 AE (a)Eval 15768.1.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15768.2 b."CPW"Casement Picture Window Extruded PVC Fixed Casement Picture Window-(O Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15768 R4 II (a)Inst 15768.2.udf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15768.2 for Design Pressure Ratings,any FL15768 R4 AE (a)Eval 15768.2.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15768.3 c."Imperial LS PW12"Picture Extruded PVC Fixed Picture Window-(O Configuration) Window Limits of Use Installation Instructions Approved for use in HVHZ:No FL15768 R4 II (a)Inst 15768.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15768.3 for Design Pressure Ratings,any FL15768 R4 AE (a)Eval 15768.3.1)df additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15768.4 d,"54)0 PW54(G5401)"Picture Extruded PVC Fixed Picture Window- (O Configuration) Window Limits of Use Installation Instructions Approved for use in HVHZ:No FL15768 R4 II (a)Inst 15768.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15768.4 for Design Pressure Ratings,any FL15768 R4 AE (a)Eval 15768.4.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15768.5 e."5400 PW54(G5401)"Picture Extruded PVC"Impact"Fixed Picture Window-(0 Window Configuration) Limits of Use Installation Instructions Approved for use In HVHZ:No FL15768 R4 II (a)Inst 15768.5.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15768.5 for Design Pressure Ratings,any FL15768 R4 AE (a)Eva[15768.5.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15768.6 f."5300 PW53(G5301)"Picture Extruded PVC Fixed Picture Window-(0 Configuration) Window Limits of Use Installation Instructions Approved for use in HVHZ:No FL15768 R4 II (a)Inst 15768.6.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3e I SAInEOW... 1/3/2018 Florida Building Code Online Page 3 of 4 Design Pressure:N/A Evaluation Reports Other:See INST 15768.6 for Design Pressure Ratings,any FL15768 R4 AE (a)Eval 15768.6.odf additional use limitations,Installation instructions and Created by Independent Third Party:Yes product particulars. 15768.7 g."5300 PW53(G5301)"Picture Extruded PVC"Impact"Fixed Picture Window-(0 Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15768 R4 II (a)Inst 15768.7.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15768.7 for Design Pressure Ratings,any FL15768 R4 AE (a)Eval 15768.7.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15768.8 h.Series"Barcelona"Model PW30I Extruded PVC"Impact"Picture Window-Missile Level"D" Includes Wind Zone 4(O Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15768 R4 1I (a)Inst 15768.8.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15768.8 for Design Pressure Ratings,any FL15768 R4 AE (a)Eva[15768.8.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes r 15768.9 i.Series"Barcelona"Model PW30I Extruded PVC"Impact"Picture Window for use in the High Velocity Hurricane Zone(O Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15768 R4 II (a)Inst 15768.9.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P7.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15768.9 for Design Pressure Ratings,any FL15768 R4 AE (a)Eval 15768.9.odf additional use limitations,installation instructions and Created by Independent Third Party:Yes PTuc pa [cul rs. 15768.10 7j.�Series"Barcelona"Model PW30I Extruded PVC"Impact"Picture Window(Geometric Shapes) -Missile Level"D"Includes Wind Zone 4(O Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FL15768 R4 II (a)Inst 15768.10.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15768.10 for Design Pressure Ratings, FL15768 R4 AE (a)Eval 15768.10.odf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15768.11 k.Series"Barcelona"Model PW30I Extruded PVC"Impact"Picture Window(Geometric Shapes) for use in the High Velocity Hurricane Zone(0 Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15768 R4 lI (a)Inst 15768.11.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15768.11 for Design Pressure Ratings, FL15768 R4 AE (a)Eval 15768.11.odf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. _.............._........................- -- —-- 15768.12 I.Series"Barcelona"Model PW30 Extruded PVC"Non-Impact"Fixed Picture Window-(O Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:No FLI5768 R4 II (a)Inst 15768 12.odf Approved for use outside HVHZ:Yes Verified By:Lyndon F.Schmidt,P.E.43409 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See INST 15768.12 for Design Pressure Ratings, FL15768 R4 AE (a)Eval 15768 12.odf any additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. Back Next Contact us::7601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3e 1 SAInEOW... 1/3/2018 Florida Building Code Online Page 4 of 4 The State of Florida is an AN EEO employer.Coovriaht 2007-2013 State of Florida.::privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a publk-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.if you have any questions,please contact 850.487.1395.•Pursuant to Section 455.27 5(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The Malls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product tAApproval Accepts: Credit Card Safe https://www.tloi-idabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3e 1 SAInEOW... 1/3/2018 R W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 ProductReport No.: FL-15768.9 Evaluation Date: Product Sub Category Manufacturer Product Name Category Soft-Lite LLC "BARCELONA" Windows Fixed 10250 Philipp Parkway Model"PW301" Streetsboro,OH 44241 Picture Window (330)528-3400 1 'Impact" Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F. Schmidt, P.E. (System ID#1998) for Soft-Lite LLC based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval,Department of Business&Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Lnd tions: product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements uding the"High Velocity Hurricane Zone". duct anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or co. en used in the"HVHZ",this product complies with Section 1626 of the FBC and does not require an impact resistant covering. 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. conditions that deviate from the details of drawing FL-15768.9 require further engineering analysis by a licensed engineer oristered architect. s product meets the water infiltration requirements for"HVHZ".drawing FL-15768.9 for size and design ressure limitations. rting oc 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 03001816 TAS 201,202&203-94 Testing Evaluation Lab, Inc. Lyndon F.Schmidt, P.E. TEL 03001819 TAS 201,202&203-94 Testing Evaluation Lab, Inc. Lyndon F.Schmidt, P.E. TEL 03001822 TAS 201, 202&203-94 Testing Evaluation Lab, Inc. Lyndon F. Schmidt, P.E. 2. Miami Dade NOA Materials Testinq 14-0916.11 SentryGlas®Interlayer(Kuraray) 15-1201.11 Safiex®PVB Interlayer(Eastman Chemical Company) 15-0528.13 PVC Extrusions(Vision Extrusions Ltd.) 3. Drawing No. Prepared by Signed&Sealed by No. FL-15768.9 RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt, P.E. 4. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants, Inc.(CA#9813) ,,�tti�u�b1�1��tJ, Lyndon F.Schmidt, P.E. ASTM E 300 Glass Load Lyndon F. Schmidt, P.E. ,��.�`F.SCH1Lj/'DT,��' 5. Quality Assurance •� �' �•��'• �. Certificate of Participation issued by Farabaugh Engineering and No 43409 Testing,Inc,certifying that Soft-Lite LLC is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. -fl' to STATE OF •W: i0.t�'•.� Q:'�%� Lyndon F.Schmidt,P.E. �� F ••4 0 R p'� �\ FL PE No.43409 ee Sheet 1 of 1 ', &/a �;E go` 8/29/2017 oft.-Lite ............. U . SEE CHART FOR i o Bwindows --- FRAME SIZES Bringing quality to light. ... ....; rllllitt Z 6;o 10250 Philipp Parkway U N•;z Streetsboro.Ohio 44241 _.. . v o xz°4 ---— F• o V N f N n 5 t m "BARCELONA" ,�i ; 4~ maa4 Model "PW301" 8 31a PICTURE WINDOWz "IMPAcrr N Z zw 2 m Q I N wv U p Q� h v ^ a aN GENERAL NOTES n a a 1. This product has been evaluated and is in compliance with the5th Edition(2014)Florida Building m Code(FBC)structural requirements including the"High Velocity Hurricane Zone'(HVHZ). 2. Product anchors shall be as fisted and spaced as shown on details.Anchor embedment to base o material shall be beyond wall dressing or stucco. N 6 3. When used in the"HVHZ"this product complies with Section 1626 of the Florida Building Code 1 z and does not require an impact resistant covering. � I 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of this drawing require further engineering analysis _ by a licensed engineer or registered architect. MAX. MAX. DESIGN PRESSURE(PSI) FRAME D.L.O. GESS 6. This product meets water infiltration requirements for"HVHZ". DIMENSI TYPE RIVE NEGATIVE o V" a 48.0"X 63.0" 41.56"x 5656" G11 +60.0 -65.0 _ Z TABLE OF CONTENTS Dire: 4126117 i SHEET6 DESCRIPTION 48.0"X 73.0" 41.56"x 66.56" G2 +55.0 -60.0 s N.T.S. € 1 Typical elevations,design pressures and general notes Dwc BY.. JK m 2 Horizontal cross sections 56.0"X 80.0" 49.56"x 73.56" G3 +60.0 -65.0 cwc BY. LFSDRWNG ; 3 Buck and frame anchori 4 &'G of materials,components and k>ang detail r FL—15768.9 a n OsHm_L OF 4 R:\Oknts\Solt-Ute Pennanent\A-Florlda Product Approvals\FL-15768 Fixed\C- Drawings\FL 15768(2017)\FL-15768.8-9.dwg,2.2 �NpJ IN—° °0 a 0D m a'A ON \ 'O v N N T T n � o ^ W j, A N Z W 0 . ; N N = s 2 m A N f7 m O r O 7np ° aTN NO A ? a W �O xs r O N N N T W O -O z 0 N _ A0 z — W JO 1fl A P PRODUCT: Dol.,rn.at. Pnpar.d 9y:. BTAM OF IN r'12 SOFT—LITE WINDOWS P.E. No.F 43409 lot Cn � 2 N �� III111 Gw\\ $ r• ` -i O1 PART OR ASSEMBLY: GD n,,BUILDING CONSULTANTS m , INC. 7S (n JLM P.O. Box 230, Valrico, FL 33595 I� NO DATE CROSS HORIZONTAL lY� Phone No.: 813.a P.O. REVISIONS FBPE C . No. 9813 C 2017 R.W.8-DING CON8ULTAuta INC. 10.5 MAX O.C. (TP) 17'O.C.(TYP.) 6' ••��\ rz>n� z 6;6 U N Z rr ��LL � a o o205 D 2X BUCK Fi$ o m o 0 \V t J CW a m TYP. 1X BUCK G `v 4 a K 2X BUCK DIRECT TO N e c z° BUCK MASONRY XE o° FRAME�� (TYP.) g 3d z O U o MASONRY w MASONRY OPENING w OPENING � w $ o oIN of U U O m 0 a a BUCK ANCHORING FRAME ANCHORING A E z V (n CONCRETE ANCHOR NOTES: I. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. d 2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to maintain the min.edge distance to mortar joints,additional concrete anchors i may be required to ensure the MAX.ON CENTER"dimension are not exceeded. m 3. Concrete anchor table: a F ANCHOR ANCHOR MIN. MIN.CLEARANCE MIN.CLEARANCE m TYPE SIZE EMBEDMENT TO MASONRY TO ADJACENT z EDGE ANCHOR z TAPCON° 1/4" 1-1/4" 2" 4" 4 26 i7 0 _ N.T.S. LCO 4" owc.er: JK m 8 &CON"I CHK BY LFS 3 WOOD SCREWl— orurnc wa c I.Maintain a minimum 518"edge distance,1"end distance,8 1"o.c.spacing of FL-15768.9 0 b Wood screws to prevent the splitting of wood. s 4 Y O BILL OF MATERIALS 2400 SAS(DOW) REM# MATERIAL Q A 1 X BUCK SG>=0.42WOOD 7/8"THICK GLASS :_: $ �:.�= M B 2X BUCK SG>=0.42 WOOD p 1/8"ANNEALED C 1/4"MAX.SHIM SPACE D 1/4"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL '��'•., <-6 0.090"SAFLEX®PVB INTERLAYER �i •. � o ro ro E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE �— ��''i it �`�� 1O>" 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 /qI mill rill �` Z o eo ti F #8-15 X 2-1/2"TRUSS HEAD SMS(1-3/8"MIN.EMBEDMENT STEEL 1/8 ANNEALED ^ $N z 0 G 1/4"X 3-1/4"HWH ELCO OR ITW CONCRETE SCREW STEEL 111 E m i m o 0 H 1/4"X 2-3/4"HWH ELCO OR ITW CONCRETE SCREW STEEL AIR SPACE \c t\ t �: 9 p o a 1 FRAME' PVC p(� 1/8 ANNEALED OR TEMPERED GLASS y a y r m a a 3 CHANNEL COVER` PVC 0Li E cc i 9 GLAZING BEAD' PVC E v° STAINLESS STEEL SPACER Sa: 'THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY EXTRUDERS LICENSEES IN"AAMA CERTIFICATIONS PROGRAMS FOR RIGID PVC EXTRUSIONS'. GLAZING DETAIL z Gl 5/8 GLASS BRE Z 2400 SAS(DOW) to a� 7/8"THICK GLASS 4.288 oo o e 2.368 I 1/8"ANNEALEDv 3 u �j �� 0.090"SAFLEXO PVB INTERLAYER ~ N v a o 00 U N O O¢ 1/8"ANNEALED 0 J ¢ a = F 0 p0 AIRSPACE a a m 3/16"ANNEALED OR CO 322" O TEMPERED GLASS FOAM SUPER SPACER E 2.33" 0.065" G2 GLADNG DETAIL IS" SIT GLASS BITE 2400SAS(DOW) o - ❑ 7/8"THICK GLASS �i Er-i "HVHZ"GLAZING NOTES:1.GLAZING>36'WIDE RG TO FB TWO(I 2411G 3/16"ANNEALED BLOCKS CONFORMING TO FBC SECTION 2411.3.3.1 2*TEMPERED GLASS IS REQUIRED FOR EXTERIOR 3 P( d GLASS GREATER THAN 30 FEET ABOVE GROUND. n z FRAME T w z 0.090'SentryGlas Interlayer a �ro � z z b 0.97' 1.216- u z Y C p0 AIRSPACE ate: 4/26/17 i 0 '� 3/16'ANNEAUED OR SCALE: N.T.S. € TEMPERED GLASS* DWC.BY: JK m' - p v CHK.BY: LFS 3 o FOAM SUPER SPACER oanwac NO, rc N 9 GL421NG BEAD 3 CHANNEL COVER G3 GLAZING DETAIL FL-15768.9 r GsHeet 4 OF 4