Property In formation Building Information
Owner: SPENCER&DANIEL&ANNE VANLIESHOU Wind Zone: 170 MPH.
Address: 7901 WINTER GARDEN PKWY Exposure Category: C
FORT PIERCE,FL 34951 1Minimum Building Dimension: 30 ft.
Mean Roof Height: 12 ft.
Risk Category: II
Design Pressure Calculations
opcuina Location iDC\ice Device Device Max Positive Max Negative
Number Zone �� Width(in) Height(in) Elevation(ft) J Pressure(psf) Pressure(psf) J
I lilt73 37 7 36.3 39 S
2 _ End 73 _— 37 7 _ 36.3 -47.5
3 Int 73 37 7 36.3 -39.5
4 Int 73 36 7 36.3 -39.5
5 Int 34 49 7 37.4 -40.6
6 Int 42 49 7 36.9 40.1__.
7 Int 34 49 7 37.4 -40.6
Prepared in accordance with:ASCE 7-10,Chapter 30.!find Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page I of 1
WINDOW & DOOR OPENING INFORMATION
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone -100/6 of least horizontal dimension or 40°x6 of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING MULLION SHUTTERS
NUMBER or Interior OR DOOR NUMBER (+) PSF (-)PSF (+)PSF (-)PSF DIMENSIONS REQ Y/N
SIZE
REQ Y/N/NA
1 Int Window FL15781.11 55 60 36.3 -39.5 73 x 63 7307 No No
2 End Window °'"''° FL15781 11 55 60 36.3 -47.5 73 x 63 7307 No No
3 Int Window FLI5781.11 55 60 36.3 -39.5 73 x 63 7307 No No
4 Int WindowG FL 15781.11 55 60 36.3 -39.5 73 x 03 7306 No No
5 Int Window 7s L FL15780.8 55 65 37.4 -40.6 54 34x49 YES No
6 Int Window ,�'`°""`° FL 15768.9 60 65 36.9 -40.1 48 x 63 42x49 YES No
7 Int `4'i"d°� '" ''°" FL 15780.8 55 65 37.4 -40.6 '�x"' 34x49 YES No