HomeMy WebLinkAboutWind Load Calculation R R W Building Consultants, Inc.
WB Consulting and Engineering Services for the Building Industry
C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197
Florida Board of Professional Engineers Certificate ofAuthorization No.9813
/ / 'port I / i
i
Product
Category Sub Category Manufacturer Product Name
Plastpro Inc. Glazed Fiberglass Doors
Exterior Swinging
Exterior Door 5200 W.Century Blvd. Doubles.
Doors Assemblies 9 Los Angeles,CA w/or w/out Sidelites
Phone 440.969.9773 Inswing/Outswing-"Impact"
Scope: Product Evaluation report issued by R W Building Consultants, Inc.&Lyndon F.Schmidt, P.E. (System ID#1998)for
Plastpro Inc.,based on Rule Chapter No.61G20-3,Method 1 D of the State of Florida Product Approval,Department of
Business&Professional Regulation.
RW Building Consultants and Lyndon F.Schmidt, P.E.do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named
herein.
Limitations:
1. This product has been evaluated and is in compliance with the 6th Edition(2017) Florida Building Code structural requirements
excluding the"High Velocity Hurricane Zone".
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2&R301.2.1.2 and does
not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM El 996
and FBC Sections 1609.1.2.2&R301.2.1.2.1.
4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction.
5. Site conditions that deviate from the details of drawing FL-17347.8 require further engineering analysis by a licensed engineer or
registered architect.
6. See drawing FL-17347.8 for size and design pressure limitations.
Supporting Documents:
1. Test Report No. Test Standard Testing Laboratory Signed by
TEL 01390410 ASTM E330-02, E331-00 Testing Evaluation Lab.,lnc. V. K.Wright
TEL 01390454 ASTM E330-02, E331-00 Testing Evaluation Lab.,lnc. V.K.Wright
TEL 01391140 ASTM E330-02, E331-00 Testing Evaluation Lab.,lnc. V.K.Wright
TEL 01391120 TAS 201,202&203-94 Testing Evaluation Lab.,lnc. William B.Shelton,P.E.
2. Miami-Dade NOA Materials Testing
17-0712.05 Saflex°PVB Interlayer(Eastman Chemical Company)
3. Drawing No. Prepared by Signed&Sealed by
No, FL-17347.8 RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt,P.E.
4. Calculations Prepared by Signed&Sealed by
Anchoring RW Building Consultants, Inc. (CA 49813) Lyndon F.Schmidt,P.E.
5. Quality Assurance
@S"uf�p�
Certificate of Participation issued by National Accreditation and !Sc r ®oo
Management Institute,certifying that Plastpro Inc.is manufacturing products •y. Ao
within a quality assurance program that complies with ISO/IEC 17020 and 4,wA' ,9�; 1Q $ 4-1
Guide
Guide 53. 43409
C)RI .-- y4 Ob
®fid®"ON
Lyndon F.Schmidt,P.E.
FL PE No.43409
9/25/2017
Sheet 1 of 1