Loading...
HomeMy WebLinkAbout2 NOA FL20470.10 (1) R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product Evaluation Report Report No.: FL-20470.11 / 16,2017 Product Sub Category Manufacturer Product Name Category Therma-Tru Corporation Fiber-Classic and Smooth-Star Exterior Swinging 118 Industrial Dr Composite Edge Glazed Fiberglass Single Door Doors Exterior Door Edgerton,OH 43517 w/Sidelite(s) Assemblies Phone 419-298-1740 Inswing/Outswing "Impact" Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E.(System ID# 1998)for Therma Tru Corporation based on Rule Chapter No.61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business&Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code(FBC)structural requirements including the"High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the"HVHZ"this product complies with Section 1626 of the Florida Building Code and does not require an impact resistant covering. 4. When used in areas outside of the"HVHZ"requiring wind borne debris protection this product complies with FBC Sections 1609.1.2& R301.2.1.2 and does not require an impact resistant covering. This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM El996 and FBC Sections 1609.1.2.2&R301.2.1.2.1. 5. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 6. Site conditions that deviate from the details of drawing FL-20470.11 require further engineering analysis by a licensed engineer or registered architect. 7. This product meets the water infiltration requirements for the"HVHZ". 8. Outswing configurations using Coastal Sill (Item#19)and Composite Sill (Item#16)under active doors and all sills used under sidelites meet water infiltration requirements for"HVHZ". All other configurations do not meet the water infiltration requirements for the"HVHZ" and shall be installed only in non-habitable areas or at habitable locations protected by an overhang or canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. 9. See drawing FL-20470.11 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 01461571 TAS 201,202&203(94) Testing Evaluation Lab.,lnc. William Shelton, P.E. TEL 01460105.1 TAS 201,202&203(94) Testing Evaluation Lab.,lnc. Lyndon F.Schmidt, P.E. TEL 01460144 TAS 201,202&203(94) Testing Evaluation Lab.,lnc. Lyndon F.Schmidt, P.E. 2. Miami-Dade NOA Materials 16-1117.01 Trosifol PVB® Interlayer(Kuraray America) 15-1201.11 Saflex PVB® Interlayer(Eastman Chemical Company) 3. Drawing No. Prepared by Signed&Sealed by No. FL-20470.11 RW Building Consultants, Inc. (CA#9813) baey25Dell®ds��e Lyndon F.Schmidt, P.E. 4. Calculations Prepared by �c�j, r Signed&Sealed by ! eeeo Anchoring RW Building Consultants, Inc. (CA#9813) ,Oe��F'.••...� .�,�` 000� Lyndon F.Schmidt, P.E. ASTM E1300 Glass Load Lyndon F. Schmidt, P.E. �� ",G SC o® V 5. Quality Assurance a No 43409 Certificate of Participation issued by National Accreditation and Management Institute, certifying that Therma Tru Corporation is manufacturing products within a quality assurance program that complies®�:� STATE OF with ISO/IEC 17020 and Guide 53. 0 `, m oa�,000�un 0 Ft\p. ?cv� O1405'a�)NA �G,.��o Lyndon FL PE No.43409 8/18/2017 Sheet 1 of 1