Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3 NOA FL20470.10 (1)
R W Building Consultants, Inc. Consulting and Engineering Services for the Building Industry P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 I2017 Manufacturer Plastic Materials Testing Therma-Tru Corporation Polyurethane Foam Core 118 Industrial Drive Fiberglass Door Skin(SMC) Edgerton,OH 43517 Lite Frames(SMC,BTS,PVC) Phone 419.298.1740 Scope: Plastics testing performed for Therma-Tru Corporation: Material Test Report No. Test Standard Testing Laboratory Signed by Polyurethane Foam Core ATI 67508.01-106-18 ASTM D 1929-96 Architectural Testing Lab. Joseph A.Reed,P.E. Polyurethane Foam Core 15427-107362 ASTM E 84-00a Omega Point Lab. John W.Dougherty,P.E. Fiberglass Door Skin(SMC) TEL 01460336-A ASTM D 635-03 Testing Evaluation Lab. Lyndon F.Schmidt,P.E. TEL 01460336-8 ASTM D 1929-96 Testing Evaluation Lab. Lyndon F.Schmidt,P.E. TEL 01460336-C ASTM D 2843-99 Testing Evaluation Lab. Lyndon F.Schmidt,P.E. BTS Lite Frame TEL 01460337-A ASTM D 635-03 Testing Evaluation Lab. Lyndon F.Schmidt,P.E. TEL 01460337-B ASTM D 1929-96 Testing Evaluation Lab. Lyndon F.Schmidt,P.E. TEL 01460337-C ASTM D 2843-99 Testing Evaluation Lab. Lyndon F.Schmidt,P.E. SMC Lite Frame TEL 01460338-A ASTM D 635-03 Testing Evaluation Lab. Lyndon F.Schmidt,P.E. TEL 01460338-B ASTM D 1929-96 Testing Evaluation Lab. Lyndon F.Schmidt,P.E. TEL 01460338-C ASTM D 2843-99 Testing Evaluation Lab. Lyndon F.Schmidt,P.E. PVC Lite Frame TEL 01460339-A ASTM D 635-03 Testing Evaluation Lab. Lyndon F.Schmidt,P.E. TEL 01460339-B ASTM D 1929-96 Testing Evaluation Lab. Lyndon F.Schmidt,P.E. TEL 01460339-C ASTM D 2843-99 Testing Evaluation Lab. Lyndon F.Schmidt,P.E. Exposed Plastics ETC-01-741-1 1 075.0 ASTM D 638-96 ETC Laboratories,Inc. Joseph L.Doldon,P.E. (BTS,SMC,PVC) ETC-01-741-1 1 076.2 ASTM D 638-96 ETC Laboratories,Inc. Joseph L.Doldon,P.E. ETC-01-741-10921.0 ASTM D 638-96 ETC Laboratories,Inc. Joseph L_Doldon,P.E. STTS00001 ASTM G 26-95 Sub-Tropical Testing Lon Hicks,V.P. STTS 99-0513.01 ASTM G 7-97(5 yr.exposure) Sub-Tropical Testing Lon Hicks,V.P. Equivalency of Standards Test Standards Used 6th Edition(2017)FBC Referenced Standards ASTM D 635-03 ASTM D 635-10 ASTM D 638-96 ASTM D 638-03 ASTM D 1929-96 ASTM D 1929-12 ASTM D 2843-99 ASTM D 2843-10 ASTM E 84-00a ASTM E 84-13a ASTM G 26-95 ASTM G 155-05a The products referenced above have been tested to the standards listed. It has been determined by Lyndon F.Schmidt,P.E. and RW Building Consultants,Inc.that the tested standards are equivalent to the referenced test standards as adopted by the 6th Edition(2017)Florida Building Code. J 0 o c �tl0 U SUTE OFY �q L ndon F.Schmidt,P.E. �o�(�'•,T y`o�'O% FL PE No.43409 8/16/2017 Sheet 1 of 1 i�'9 O ©•`�0®® *414- �➢i 19 low-