HomeMy WebLinkAboutRevisions OFF CE USE ONLY:
DATE FILED: nERMIT# 1806-0587
REVISION FEE: ISoo RECEIPT#
PLANNING &DEVELOPM NT SERVICES
BUILDING&CODE REGULA HON DIVISION
2300 VIRGINII AVENUE
FORT PIERCE,F 34982-5652
(772)462 1553
APPLICATION FOR BUILDI G PERMIT REVISIONS
PROJECT INFORM TION
LOCATION/SITE
ADDRESS:
6290 N US HIGHWAY 1,Fort Pierce FL
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Change of Product approval from peel n stick to 30#Felt
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CCC1327208 ST. LUCIE CO CERT. #:
BUSINESS NAME: Sunrise city CHDo Inc.
QUALIFIERS NAME. Roderick Waller
ADDRESS: 130 S Indian River Drive
CITY: Fort Pierce STATE: FL ZIP: 34947
PHONE(DAYTIME): 772-201-2850 FAX: 772-907-0420
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME): FAX:
SLCCC: 9/23/09
Revised 06/30/17
6/3/2018 Florida Building Cod Online
0 0• � x` � O � g I hV
SCIS Home j Log In User Registration Hot Topics Submit Surcharge Stat&Facts Publications FBC Staff BCIS Site Maps; Links Search
dr "
b
d _ -
y z 1 Product Approval
►(ha, M " USER:Public User
;ranstr� Y
Product Approval Menu>Product or Application Search>Application List>Application Detail
•' FL# FL2346-R7
Application Type Revision
Code Version 2017
i Application Status Approved vi 310A1
Comments
Archived C
Product Manufacturer Warrior Roofing Manufacturing
Address/Phone/Email 3050 Warrioi Road
Tuscaloosa,AL 35404
(205)553-1734 Ext 115
Steven@Wa lorRoofing.net
Authorized Signature Steven Crew
Steven@Wa riorRoofing.net
Technical Representative Steven Cre
Address/Phone/Email 3050 Warrio Road
Tuscaloosa, L 35404 :.; ti
(205)553-1734 Ext 1024
Steven@Wa riorRoofing.net
Quality Assurance Representative Steven Cre 444
Address/Phone/Email 3050 Warrio Road b U 6_ 0�0 7
Tuscaloosa, L 35404
(205)553-1 34 Ext 1024 ST.LUCIE COUNTY
Steven@Wa riorRoofing.net BUILDING DIVISION
REVIEWED
Category Roofing REVIEWED BY
FOR CO NCE
Subcategory Underlayme is DATE
PLANS AND PE IT
Compliance Method Test Report MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
Testing Lab PRI Construction Materials Technologies,LLC
Quality Assurance Entity Keystone C rtifications,Inc.
Quality Assurance Contract Expiration Date 10/05/2021
Validated By Jesus Gonzz lez,P.E.
(di Validati n Checklist-Hardcopy Received
Certificate of Independence FL2346 R7 COI PRI CMT Cert f In ependence.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D22E 2009
" ASTM D48E9 2016
Equivalence of Product Standards
Certified By Approved T sting Lab
FL2346 R7 E uiv FBC 2017 Standards Eauivalency_pdf
https://www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtOc8bnSknRps9x/o2fSloLpOST46ODBB%2baF4%3d 1/2
s
6/3/2018 Florida Building Code Online \�
r
f�
Product Approval Method Method 1 Opt on B
Date Submitted 01/17/2018
Date Validated 01/17/2018
Date Pending FBC Approval 01/17/2018
Date Approved 04/10/2018
Summary of Products
FL# Model,Number or Name D scription
2346.1 #15 and#30 roofing felt ATM D 226 Tested
Limits of Use I stallation Instructions
Approved for use in HVHZ:Yes FL2346 R7 II Instal ationInstructions.pdf
Approved for use outside HVHZ:Yes Verified By: PRI Construction Materials Technologies,LLC
Impact Resistant: N/A Test Reports
Design Pressure: N/A F L2346 R7 TR 15A Test Report.pdf
Other:Primary roof covering should be installed immediately f L2346 R7 TR 30A Test Report.pdf
after felt.Roofing felt is not intended to be an unprotected
weathering surface.
2346.2 15w and 30w roofing felt ATM D 4869 Tested
Limits of Use Installation Instructions
Approved for use in HVHZ: No I L2346 R7 II Installs i nIns ructions.pdf
Approved for use outside HVHZ:Yes Verified By: PRI Construction Materials Technologies,LLC
Impact Resistant:N/A Test Reports
Design Pressure: N/A I L2346 R7 TR 15w Test Re ojrt.pdf
Other: Primary roof covering should be installed immediately 1 L2346 R7 TR 30w Test Repo r.pdf
after felt.Roofing felt is not intended to be an unprotected
weathering surface.
Back 111ext
Contact Us::2601 Blair Stone Road,Tallah issee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Qpy_rig 2007-2013 t of Floi Ida,:: r'vacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If ou have any questions,please contact 850.487.1395."Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chi ipter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.Hc wever email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made a ailable to the public.To determine if you are a licensee under Chapter 455,F.S.,
please click here.
Product Approval Accepts:
eCFieik
Credit and
Sa e r
N of l: f,�••� (' %��r'�
iy l I
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtOc8bnSknRps9x/o 2fSIoLpOST46ODBB%2baF4%3d 2/2
- 7 �
J `
I
WARRIOR® ROOF
IN MANUFACTURING
f P.O.BOX 40185+TUSCALOOSA,AL 35404+PHO E(205)553-1734+FAX(205)553-1755
193 LEROY ANDERSON ROAD+MONROE,GA 30655 PHONE(710)207.0695•FAX(770)207-0775
® 323 DEVELOPMENT AVENUE+CHAMBERSBURG,PA 17 01 PHONE(717)709-0323+FAX(717)709-0027
Roofing Felt Installation Recommendations
• , �"�,�J X11 �t
1
Be aware that roofing felt should not be walked upon prior to fastening into position.
Proper safety equipment is recommended for all instal ations. Also,the roof decking
should be clear of debris and moisture prior to installation of the roofing felt.
Roofing felt should be installed from the bottom of the roof in horizontal layers to
increase the water shedding ability of the felt. The initial layer of felt should be installed
to cover the bottom edge of the decking,from edge to edge. Overhang is not required.
Anchor the top corner of the felt after it has been properly positioned and roll the felt out
across the roof. Pay careful attention to roll the felt o t smoothly, avoiding wrinkles as
you move across the roof. The top edge of the felt should be fastened no less than every
eight inches. The middle and bottom edge should also be fastened no less than every
eight inches. Fasteners should be applied no less than every eight inches along the eaves.
The next-course of felt should also be aligned with the roof edge and should overlap the
previous course two inches(sometimes referred to as ead lap). In the event you get to
the end of a roll prior to getting to the opposite edge o the roof,begin a new roll with a
four inch overlap over the end of the prior roll (sometii nes referred to as end lap). The
same fastening pattern used on the middle and bottom *f the initial course should be used
for each subsequent course. For the top of each subsequent course,fasten intermittently
to hold the top edge in place until the next course is ap lied. The fasteners in the bottom
of the next course will hold the top of the previous cou rse securely.
Continue up the roof in this manner. Be sure to firmly fasten the top of the final course if
it terminates at the top edge of the roof. Otherwise,ov erlap the felt over the ridge and
secure then begin at the bottom of the other side of the ridge and repeat the process.
In valleys,lay a vertical section of roofing felt the length of the valley prior to the
installation of the horizontal runs of roofing felt. If you use more than one section of
roofing felt in a valley,be certain to start at the bottom and.overlap.each.Subsequent
length a minimum of two inches as you move up the v Ile y to ensue prQpevutex
shedding.
1
5' r
I
Via•
A'
In the event some wrinkles are created while fastenin down a course of felt, slice the
i wrinkles and fasten them flat to the deck. Then seal t e cuts with waterproofing cement.
Installation of the primary roof covering(ex. Shingles is recommended immediately
after felt installation.
;NOTE: LOCAL BUILDING CODES MAY REQUIRE A DIFFERENT FASTENING
PATTERN AND/OR SPECIFIC FASTENER TYPEE THAN RECOMMENDED BY
THESE INSTRUCTIONS. PLEASE CONTACT YC UR LOCAL BUILDING CODE
ADMINISTRATOR FOR THE EXISTENCE OF REGIONALLY SPECIFIC
FASTENING REQUIREMENTS.
1
ISi
•-
•
,� RY ct x'd � ��'1P' �{81• �c' bb H t .<i.
t ktt����.nF•�•``5 _�.�frt,.lP i� �ry...'lrf mfr �y
"771, R,� v,r ✓>/rNa N:.
,�^ ..